esists Fraying When Expansion Range
Nominal Part Bulk Shop Available Lbs/
Cut With Scissors Size # Spool Spool Colors 100’
Min Max
I ncreased Braid Density 1/8” CCP0.13 1/8” 1/4” 1,000’ 100’ 2 0.40
For Fuller Coverage 1/4” CCP0.25 5/32” 7/16” 1,000’ 100’ 2 0.46
3/8” CCP0.38 3/16” 5/8” 500’ 100’ 2 0.74
H
igh Abrasion 1/2” CCP0.50 1/4” 3/4” 500’ 100’ 2 0.82
Resistance 3/4” CCP0.75 5/8” 1” 250’ 75’ 2 1.11
1” CCP1.00 3/4” 1 3/16” 250’ 50’ 2 1.24
C
ut And Abrasion 1 1/4” CCP1.25 1” 1 1/2” 250’ 50’ 2 1.56
Resistant 1 1/2” CCP1.50 1 1/4” 2” 250’ 50’ 2 1.85
1 3/4” CCP1.75BK 1 1/2” 2 1/8” 200’ 50’ 2 2.30
H
alogen Free 2” CCP2.00BK 1 3/4” 2 1/2” 200’ 50’ 2 2.80
Drawing Number
TF001CCPT-WD
Black (BK) and Gray (GY).
www.techflex.com
800.323.5140 • 973.300.9242 • fax: 973.300.9409
104 Demarest Road • Sparta, NJ 07871
ADVANCED
GENERAL ENGINEERING
PURPOSE
Technical Data Sheet
Technical Data Sheet
Melt Point
ASTM D-2117
www.techflex.com
Medium
Abrasion Test Machine
Taber 5150 Minimum Continuous
-94°F (-70°C)
Abrasion Test Wheel
Calibrase H-18 CHEMICAL
Abrasion Test Load RESISTANCE
500g 1=No Effect 4=More Affected
Room Temperature
2=Little Effect 5=Severely Affected PHYSICAL
77°F 3=Affected
PROPERTIES
Humidity
Aromatic Solvents_________________ 2 Monofilament Diameter________ .008”
72% Avv 204
Aliphatic Solvents__________________ 1
A Few Strands Beginning Chlorinated Solvents_______________ 3 Flammability Rating____________ UL94
To Pull Out Of Sample Weak Bases_______________________ 1 Recommended Cutting____ Scissor/HK
550 Test Cycles Salts_____________________________ 1 Colors__________________________ 2
Strong Bases______________________ 2 Wall Thickness_________________ .024”
Small Hole In Material
Tensile Strength (Yarn)_____________ 6
650 Test Cycles Salt Water 0-S-1926_________________ 1
ASTM____________________________
Hydraulic Fluid MIL-H-5606__________ 1 D-2256 Lbs
Material Destroyed
800 Test Cycles Lube Oil MIL-L-7808________________ 1 Specific Gravity ASTM D-792______ 1.38
De-Icing Fluid MIL-A-8243___________ 1 Moisture Absorption %__________ .1-.2
Pre-Test Weight ASTM D-570
Strong Acids______________________ 3
3,168.1 mg Hard Vacuum Data_________________
Strong Oxidants___________________ 2
ASTM E-595 at 10-5 torr
Post-Test Weight Esters/Ketones____________________ 1
2,771.9 mg TML___________________________ .19
UV Light_________________________ 1
CVCM_________________________ .00
Test End Loss Of Mass Petroleum________________________ 1
Point Of Destruction WVR___________________________ .16
Fungus ASTM G-21_________________ 1
396.2 mg Smoke D-Max___________________ 56
Halogen Free____________________ Yes ASTM E-662
RoHS___________________________ Yes Outgassing___________________ Med
SVHC_________________________ None Oxygen Index___________________ 21
ASTM D-2863
© 2020 Techflex® - Any unauthorized reproduction, in whole or part, in any medium whatsoever, without the express written permission of Techflex® is strictly forbidden.
Techflex® product names and logos are registered trademarks of Techflex®, unless otherwise attributed. The contents and illustrations contained herein are believed to be reliable.
Techflex® makes no warranties as to their accuracy or completeness and disclaims any liability in connection with their use. Techflex’s® only obligations are those in standard terms of
sale for these products and Techflex® will not be liable for any consequential or other damages arising due to misuse of these products or typographical errors or omissions.
Users should make their own evaluation to determine the suitability of these products for their unique and specific applications. 01-02