Sunteți pe pagina 1din 22

SCHEDULE - B

NAME OF WORK: -
Construction Gym Center Building from Idariya Shila Udhyan Near At Idar Nagarpalika Idar

RECAPITULATION SHEET
Sr.No
Name Of Work Amount
.
Construction Gym Center Building from Idariya Shila Udhyan Near At Idar
1 Nagarpalika Idar 6308602.83

2 Electrical Work 630842.75

3 Plumbing Work 630277.57

Total 7569723.15
Say 7569724.00

I/ WE AGREE TO CARRY OUT THE ABOVE WORK AT……….%

(_______________________________________________) ABOVE / BELOW


THE ABOVE MENTIONED COST.

DATE :-
PLACE :- ……………………………………..

Contractor Signature Chief Officer


Idar Nagarpalika
Idar Dist – SK
IDAR NAGARPALIKA
Name Of Work :
Construction Gym Center Building from Idariya Shila Udhyan Near At Idar Nagarpalika
Idar

ABSTRACT SHEET
2015 -16 R & B
Sr. Total
Qty. Item Units Amount
No Rate
Excavation for foundation upto 1.5 m depth including sorting out
1 178.00 and stacking of useful materials and disposing off the excavated 148.08 Cu.Mt 26358.24
stuff upto 50 Meter lead.(C) Hard Murrum
Excavation for foundation upto 1.5 m depth including sorting out
2 39.00 and stacking of useful materials and disposing off the excavated 152.98 Cu.Mt 5966.22
stuff upto 50 Meter lead.(D) Soft rock not requiring Blasting
Filling available excavated earth (excluding rock) in trenches, plinth,
3 158.00 sides of foundations etc. in layers not exceeding 20 cm. in depth 77.23 Cu.Mt 12202.34
consolidation each deposited layer by ramming and watering.
Filling in foundation and plinth with murrum or selected brout for out
4 183.00 side soil in layers of 20 cm. thickness including watering, ramming and 250.34 Cu.Mt 45812.22
consolidating etc. Complete.
Carrying out plinth treatment to post constrution/existing structrue by
spraying chemical solution for termite control treatment including
labour and material consistent with I.S.I specification.using
chordeneand chiorpuffiles 20 EC as per 6131_paret - II consentration
5 540.00 75.65 Sq.Mt 40851.00
Weight One percent is recommended i.e one liter 20EC chemical
emulsion with 19liter give 1% concrentration inclusive of one liter
chemical emulsion appication at the rate of 5 liter chemical /Sqm of
Sarface is recommended as per I.S.
Filling in plinth with sand under floors including watering ramming,
6 81.00 385.78 Cu.Mt 31248.18
consolidating and dressing etc. complete
Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6
Crushed stone aggregates 40 mm nominal size) for Foundation and
plinth, and excluding cost of reinforcement in reinforced concret for
following grades, machined batched & machine vibrated design mix
7 12.00 concrete using graded hard (black trap) stone aggregate of 40mm 2507.28 Cu.Mt 30087.36
nominal size obtained from quarry including mechanical mixing,
mechanical vibrating, compaction, finishing, curing Completed as
approved by the Architect and Engineer-in-charge, (A) Foundation and
plinth.
Providing & laying in position controlled reinforced cement concrete M-
250 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
8 19.00 5885.62 Cu.Mt 111826.78
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, (A) Foundations footing base of columns and mass concrete
(PRC/10/2017/CEMENT CONSUMPTION/16/C(70X4.76)=333.20(-
6160.55 -333.20)=5827.35
Providing & laying in position controlled reinforced cement concrete M-
250 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
9 4.00 3932.70 Cu.Mt 15730.80
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge,., (D) Coulmns, Pillars, posts and strut upto floor two level
(Pedestal) (PRC/10/2017/CEMENT
CONSUMPTION/16/C(70X4.76)=333.20(-4226.96 -333.20)=3893.76
Providing & laying in position controlled reinforced cement concrete M-
250 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
10 25.00 4807.45 Cu.Mt 120186.25
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, (C) Ground beam / Plinth Beam
(PRC/10/2017/CEMENT
CONSUMPTION/16/C(70X4.76)=333.20(5093.05 -333.20)=4759.85
Brick work using common burnt clay building brick having crushing
11 26.00 strength not less than 35 kg/sq. cm. in foundation and plinth in cement 2852.32 Cu.Mt 74160.32
mortar 1:6 (1 Cement : 6 fine sand) (b) Conventional
Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand :
4 Crushed stone aggregates 20 mm nomial size) and curing complete
excluding cost of form work for following grades, machined batched &
machine vibrated design mix concrete using graded hard (black trap)
12 16.00 stone aggregate of 20mm nominal size obtained from quarry including 4644.46 Cu.Mt 74311.36
mechanical mixing, mechanical vibrating, compaction, finishing, curing
etc Completed as approved by the Architect and Engineer-in-charge,
(A) Wall caps / coppings. (PRC/10/2017/CEMENT
CONSUMPTION/16/C(30X4.76)=142.80(4741.28 -142.80)=4598.48
Providing & laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 8
Crushed stone aggregates 40 mm nominal size) and excluding cost of
reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 40mm nominal size obtained from
13 64.00 quarry including mechanical mixing, mechanical vibrating, compaction, 2253.30 Cu.Mt 144211.20
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, in cement mortar in proportion recommended by the
manufacturer.., (A) Foundation and plinth.

Providing & laying in position controlled reinforced cement concrete M-


250 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
14 37.00 5885.62 Cu.Mt 217767.94
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, , (D) Coulmns, Pillars, posts and strut upto floor two level
(PRC/10/2017/CEMENT CONSUMPTION/16/C(70X4.76)=333.20(-
6160.55 -333.20)=5827.35
Providing & laying in position controlled reinforced cement concrete M-
200 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
15 110.00 5463.30 Cu.Mt 600963.00
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, Slab Beam. Up to All Floor (PRC/10/2017/CEMENT
CONSUMPTION/16/C(40X4.76)=190.40(5599.61 -190.40)=5409.21

Providing & laying in position controlled reinforced cement concrete M-


200 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
16 8.00 5060.37 Cu.Mt 40482.96
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge,. Lintal Up to All Floor(PRC/10/2017/CEMENT
CONSUMPTION/16/C(40X4.76)=190.40(5200.67 -190.40)=5010.27
Providing & laying in position controlled reinforced cement concrete M-
200 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
17 2.00 quarry including mechanical mixing, mechanical vibrating, compaction, 5804.38 Cu.Mt 11608.76
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, CHHAJJAS Up to All Floor(PRC/10/2017/CEMENT
CONSUMPTION/16/C(40X4.76)=190.40(5937.31 -190.40)=5746.91

Providing & laying in position controlled reinforced cement concrete M-


200 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
18 129.00 4735.48 Cu.Mt 610876.92
in-charge, SLABS Up to All Floor(PRC/10/2017/CEMENT
CONSUMPTION/16/C(40X4.76)=190.40(4878.99 -190.40)=4688.59

Providing & laying in position controlled reinforced cement concrete M-


200 and curing complete including cost of form work and excluding cost
of reinforcement in reinforced concret for following grades, machined
batched & machine vibrated design mix concrete using graded hard
(black trap) stone aggregate of 20mm nominal size obtained from
19 11.00 5386.02 Cu.Mt 59246.22
quarry including mechanical mixing, mechanical vibrating, compaction,
finishing, curing Completed as approved by the Architect and Engineer-
in-charge, STAIRCASES Up to All Floor(PRC/10/2017/CEMENT
CONSUMPTION/16/C(40X4.76)=190.40(5523.09 -190.40)=5332.69

Providing and Laying & placing in position TMT reinforcement bars


confirming to IS-1786 reinforcement for RCC structures / items as per
design including bending ,Cutting,binding,Placing ,& transporting steel
20 35753.00 to the A) High yield deformed steel bars Fe-500, yield stress not less 45.48 Kg 1626046.44
than 500 N/mm2 in Position as per Structure Deties drawing
Completed as approved by the Architect and Engineer-in-charge,
Providing and fixing M.S. grills required pattern of window etc. with
M.S. flats at required spacing & frame alround square or round bars
21 4158.00 with round headed bolts & nuts and welding or by screws and including 64.28 Kg 267276.24
one coat of primer and two coats of oil paintng etc. complete as
approved by the Architect and Engineer-in-charge, (A) Plain grill
Providing and fixing alluminium ventilation of section with frame of
63mm x 38.10mm x 1.2mm ( jindal section: 2434 @ wt. 0.643 kp per
22 2.00 mt.) with colour anodized alluminum frame for ventilation with 5mm 1399.45 Sq.Mt 2798.90
thick frosted glass as details etc Completed as approved by the
Architect and Engineer-in-charge, for ventilation.
Providing and fixing window having extruded aluminum colour
anodized section frame main outer size 63.50X38.10X1.95mm (of Jindal
section no. 2459@ Wt. 1.094 Kg/mt), horizontal three track member
size 92mm x 31.75mm x 1.30mm (of Jindal section no. 8688, @ Wt.
1.07 Kg/mt), vertical member of size 92mm 31.75mm x 1.50mm (of
Jindal section no. 8933 @ Wt. 1.06 Kg/mt) with sliding shutters of
23 27.00 horizontal member size 40mm x 18mm x 1.29mm (of Jindal Section No. 2041.93 Sq.Mt 55132.11
8947 @ Wt. of 0.456 Kg/mt), vertical member of size 40mm x 18mm x
1.29 mm (of Jindal section no: 8949 @ Wt. of 0.456 kg / mt) with 5 mm
th transparent bronze colour tinted float glass with powder coated
aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc.Completed as approved by the
Architect and Engineer-in-charge,

Provoding and fixing flush door shutters, solid core construction with
frame of first class hardwood with cross board and face veneer or
plywood face panels, including anodised alluminium butt hinges with
necessary screws. (B) Non-decorative type and block board core
24 24.00 2326.34 Sq.Mt 55832.16
anodised alluminium butt hinges in flush door shutters (2) 35 mm
thick. Providing for using bright finished M.S. piano hinges of (A) Nickel
plated piano hinges. providing vision panel not exceeding 0.1 Sq.M. in
all types of flush doors. (A) Rectangular or Square.

Providing and fixing FRP FRAME size 100 x 50mm and 28mm thick FRP
depress pannel shutter having extra reinforcement on sides and edges
and in gel coat finish. The core of the shutter is to be filled up with
injected fire retardent grade polyurethane foam done in situ along with
embedded wooden places for stiffening and also for tacking hinges and
25 5.00 3315.45 Sq.Mt 16577.25
fixture. The hole FRP frame and shutter is to be water proof, water
proof, termite proof and resistance to mild acid/Alkali. Rates are to be
inclusive of S.S hinges with necessary screws and Alluminium fixture
and fastening.Product should have 3 years prefomance guarantee and
company have ISO 9001-2000 certificate.
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
26 140.00 3014.89 Cu.Mt 422084.60
Mortar 1:6 (1- Cement : 6 -fine sand) for brick work in superstructure
above plinth level upto floor two level (B) Conventional
(i) Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
27 113.00 409.61 Sq.Mt 46285.93
Cement : 4 -coarse sand ) in foundation and plinth for brick work in
superstructure above floor two level (B) Coventional (upto 10 ton)
Providing 10mm thick cement plaster in single coat on brick/concrete
wall for interior polastering up to floor two level and finished even and
28 820.00 smooth with (II) cement mortar 1:3 (1 cement : 3 sand) curing etc. 83.87 Sq.Mt 68773.40
Completed as approved by the Architect and Engineer-in-charge, For all
floor
Providing 15mm thick cement plaster in single coat on brick/concrete
wall for interior polastering up to floor two level and finished even and
29 944.00 99.96 Sq.Mt 94362.24
smooth with (II) cement mortar 1:4 (1 cement : 4 sand) curing etc.
Completed as approved by the Architect and Engineer-in-charge,
20 mm. Thick sand faced cement plaster {GUTKA} on walls upto All
height above ground level consisting of 12 mm. Thick backing coat of
c.m. 1:3 (1 cement : 3 sand) and 8 mm. Thick finishing coat of c.m. 1:1
30 639.00 194.16 Sq.Mt 124068.24
(1 cement : 1 sand) etc. Completed as approved by the Architect and
Engineer-in-charge,

Providing and laying Mirror polished Green Marble stone slab 18 mm


(Average) thick for stair steps and riser as per design incl. full moulded
round front edge laid on 10 mm thick cement mortar 1:3 (1 -cement :
31 53.00 6 coarse sand ) jointed with grey cement slurry including rubbing and 1558.60 Sq.Mt 82605.80
polishing etc. complete
For Door/Windows sill & Jams

Providing and laying mirror polished black granite stone slab flooring
over 18 mm (average) thick base of cement mortar 1:6 (1 cement : 6
32 31.00 course sand) or L.M. 1:1.5 laid over and jointed with grey cement slurry 3722.86 Sq.Mt 115408.66
including rubbing and polishing etc. Completed as approved by the
Architect and Engineer-in-charge,. (A) 18 mm thick
Providing and laying polished kota stone slab flooring & dedo over 20
mm (average) thick base of cement mortar 1:6 (1 cement : 6 course
33 505.00 sand) or L.M. 1:1.5 laid over and jointed with grey cement slurry 645.17 Sq.Mt 325810.85
including rubbing and polishing etc. Completed as approved by the
Architect and Engineer-in-charge,. (A) 20 mm thick
Providing & Laying Marbo granite flooring tiles 8 mm thick in skirting
risers of steps and dedo on 10 mm thick cement plaster 1:3 (1 Cement :
34 41.00 783.22 Sq.Mt 32112.02
3 coarse sand) and jointed with white cement slurry.Completed as
approved by the Architect and Engineer-in-charge,
Distempering (Two coats) with oil bound washable distemper of
approved brand and manufacture and of required shade on wall /
ceiling surface to give an even shade over and including a primer coat
with with alkali resistance primer of approved brand and after
thoroughly brushing the surfaceto give an even shade after thoroughly
brushing the surface free from mortar droppings and other foreign
35 1764.00 matter and also including preparing the surface even and smooth for 93.49 Sq.Mt 164916.36
Applying two coats of Birla or Asian acrylic lappy (putty) and two coats
of primer of approved brand and manufacture on new wall surface to
give an even shade including thoroughly brushing the surface free from
mortar dropping and other foreign matter and sand papered
smooth.Completed as approved by the Architect and Engineer-in-
charge,
Wall painting two coats with weather proof acralic emulsion APEX
paint of approved brand & manufacture and of required shade on
exterior wall surface to give an even shade over and including a
36 639.00 primery coat with alkaly resistance primer of approved brand after 44.59 Sq.Mt 28493.01
throughly brushing surface to remove all dirt and remains of loose
powdered materials etc comp. for all height as approved by the
Architect and Engineer-in-charge,
Providing and laying water proofing treatment on terrace including
applying neat cement slurry 2.75 Kg./Sqmt on cement admixed with
waterproofing component after cleaning the surface, laying cement
concrete with I.P.S 50mm thick with 50% of C.M. 1:5 admixed with
waterproofing component over 20 mm thick layer of C.M.1:5 to
37 427.00 required slope including ramming at junction of wall and slab,after two 499.95 Sq.Mt 213478.65
days of proper curing applying a second coat of cement sluury,finished
the surface with 20 mm thick C.M. 1:4 china mosaic flooring and finally
finished surface with terrace shall be finished with water for a period of
two week. with 5 year no leakage geranty. Completed as approved by
the Architect and Engineer-in-charge,
Providing erecting and fixing double coated Syntex or eqivent PVC. (ISI)
mark water tank of required capicity each with all necessary &
38 1000.00 connection etc complete on terrace and testing.Completed as approved 4.66 Liter 4660.00
by the Architect and Engineer-in-charge,

Providing & Filling Sinder in Toilet Block including Cosolidation in layer


with all including material,laber,tools, tackles and equipment and
39 2.00 252.50 Cu.Mt 505.00
transpotetion work. Completed as approved by the Architect and
Engineer-in-charge,
Providing and fixing 110 cm high Stainless steel railing made from
anticorrocive 304 grade S S pipe of 50 mm dia (16Gauge) as hand rail
with S S 304 grade Baluster as a vertical support fixed in RCC slab at
1.66 m c/c including Five horizontal S S pipes of 20 mm dia (16Gauge)
40 30.00 2110.32 Rmt 63309.60
at eqal distance including accessories as per detailed drawing as
directed etc. Completed as approved by the Architect and Engineer-in-
charge,
Providing and fixing , testing, and laying and jointing of CPVC pipes
Supreme make or equivalent for cold and hot water supply as per ASTM-
D-2846, SCH-40 & Sch-80 complete with Solvent weld Sch-40-80 fitting
41 50.00 130.87 R.Mt 6543.50
such at tees, crosses,plugs, sockets, elbows, reducers, clamps,sleeve
pieces suspenders, unions, check nuts,bends etc. for External water
supply Exposed on wall pipe work.SCH-80 15 mm
42 50.00 25mm 218.61 R.Mt 10930.50
43 100.00 32 mm 305.81 R.Mt 30581.00
44 35.00 40 mm 411.18 R.Mt 14391.30
45 80.00 50 mm ( Riser,Supply pipe work) 638.16 R.Mt 51052.80
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working
pressure poluthene pipes of the following outside Dia. Low densidy,
46 30.00 105.20 R.Mt 3156.00
complete with special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and floor.(E) 50mm
47 30.00 75 mm 272.91 R.Mt 8187.30
48 30.00 110 mm 322.61 R.Mt 9678.30
Constructing Manhole with R.C.C top slab in 1:2:4 mix (1 cement ;2
coarse sand :4 graded stpme aggregate 20 mm nominal size, foundation
concrete 1:3:6 mix (1 cement :3 coarse sand :6 Brick bats 40 + 50 mm
size) inside plastering 15mm thick with cement mortar 1:5 (1 cement :5
coarses and finished with a floating coat of neat cement and making
channels :2 coatse sand :4 stone aggregate 20mm. nominal size)
50 1.00 finished smooth complete including curing and testing. (i) Inside size 9942.54 Nos 9942.54
900mm x 1200 mm and 1.5 m. deep including C.I cover with frame size
560 mm. total weight of cover and frame to be not less than 128 kgs.
(Wt. of cover 64 kgs. and thick walls of brick masonary using bricks
having crusing strenght not less then 35 kg/sq. cm in cement motar 1:5
(1 cement ;5 coarse sand)A type depth 0.9 meter for 150 mm diameter
sewer
51 1.00 B type depth 1.50 meter for 150 mm diameter sewer 17906.98 Nos 17906.98
(i) Extra rate for construction B.B masonary for every additional depth
52 1.00 of 0.1 mt or part there of over item 24.27 (ii) for depth from 0.9m to 453.05 Nos 453.05
1.5m.
(ii) Extra rate for constructing B.B masonary for every additional depth
53 1.00 of 0.1m or part there of over item 24.27 (ii) for depth from 1.50to 346.15 Nos 346.15
2.25m
Constructing brick masonray road gully chamer 500 mm x 450 mm x
54 2.00 600 mm including 500mm x 450mm C.I. horizontal grating with frame 1599.23 Nos 3198.46
complete.
Constructing brick masonry road gully chamber 450 mm x 450 mm x
55 2.00 2010.71 Nos 4021.42
775 mm with vertical grating complete.
Construction Septic tank inside dimention of 3.00 m in length &1.50 m
in width & 2.00 m depth including excavating any type of soil as shown
and mentioned in the drawing,providing and laying 0.10 m thick plain
cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone agg.)
40 mm thick IPS flooring at bottom with brick masonary 0.23 m thick
walls CM 1:5 ( 1 cement : 5 coarse sand ) and intermediate partition CM
56 1.00 27705.31 Nos 27705.31
1:4 & RCC Top slabs12 cms thick in 1:2:4 (1 cement : 2 coarse sand : 4
graded stone agg) including reinforcement as per design and 15 mm
thick cement plaster in CM 1:4 with floating coat of neat cement slurry.
Also provide Two nos CI Manhole frame and cover of size 60 cm x 45
cm & 75 mm dia. PVC 6 kgf / Sq cm pressure air vent pipe in 3.00
length with cowl etc complete as per direction of Engineer in charge.
(B) Providing sock pit of 5.00 Cu.M. Volume including excavating and
filling brickbats with dry masonry work at top for 45cm. height
57 1.00 2834.99 Nos 2834.99
including covering the top with stone including providing vatas in C.M.
1:3 with finishing curing etc. complete as directed. (upto 10 ton)
Supplying and fixing reinforced concrete heavy duty non-pressure pipes
with collars for culverts including setting and joining. The pipes in C.M.
58 30.00 1 : 2 watering and laying (to level or slope of I. S. class NP - 2 of 774.59 R.Mt 23237.70
following internal diameter.. Completed as approved by the Architect
and Engineer-in-charge, (ii) 450 mm Dia
6308602.83
Name of Work:-
::ABSTRACT OF COST::
S.O.R. 2012-13
Sr No Description of Item Qty. Rate Unit Amount
1.A Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch / bell
push & accessories and earth continuity of following type, 39 400.00 PT 15600.00
erected on PVC / Metallic box, single mounting base frame
covered with textured/metallic front plate modules erected
on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.(e) in
existing pipe CAT III

2 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in / flushed on wall/ceiling
complete with 6A Modular type switch and hum free EME
four or more step type electronic fan regulator with
separately mounted and accessories with earth continuity 10 500.00 PT 5000.00
of following type erected on PVC / Metallic box, single
mounting base frame covered with textured/metallic front
plate modules erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose / H.D.Connector as
directed.(e) in existing pipe CAT III
3 Point wiring for Looped Plug with 6A Modular type switch &
5 pin socket erected on PVC / Metallic box, single mounting
base frame covered with textured / metallic front plate 25 250.00 PT 6250.00
modules erected on / in wall / ceiling with following type
accessories CAT III
4 Point wiring for Individual Plug with & earthwire of 1.5
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type of
to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on 10 370 PT 3700.00
PVC / Metallic box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.[I] For 6A Plug with 2-1.5
sq.mm Cu. Wire.(e) in existing pipe CAT III

5 Providing following type of Modular Type Accessories


mounted with pvc / metallic box, single mounting base
frame covered with textured / metallic front plate ,
modules erected with necessary connection. As desired by
Engineer In charge
5.A (1)One No. SP 6 Amp. CAT III 20 160.00 No 3200.00
5.B (2) One No 5 pin plug CAT III 20 160.00 No 3200.00
5.C (7) Blank Plate Single CAT III 10 30.00 No 300.00
5.D (4) TV Co-axial Socket outlet CAT III 2 165.00 No 330.00
5.E (9) 16 Amp. SP one way switch CAT III 8 190 No 1520.00
5.F (10) 6/16Amp. Universal socket CAT III 8 205.00 No 1640.00
5.G (8) Angle Holder 14 22.00 No 308.00
6 Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction boxes
2000 35 Mtr 70000.00
fixed with adhesive solution & Clamps with following dia of
pipes, in approved manner as directed. (b) 25 mm

7 Providing & erecting PVC Corrugated Flexible Conduit with


required nos. of coupling, PVC bushes,check-nuts etc. 100 35.00 Mtr 3500.00
complete of following sizes.(2) 25 mm
8 Supplying & erecting UPVC Mini trunking (PVC Casing-n-
Capping) having double-locking arrangement with grooves,
trunking of size not below 12.5 mm in height as per IS with
50 45.00 Mtr 2250.00
accessories of PVC/Resin polypropylene not below 1.8 mm
thick duly sealed in joint & erected on wall / ceiling of
following size .(2) 25 mm
9 Providing & Erecting 3mm thick Polycarbonate(PC) Sheet
1670 1.51 Sq inch 2521.70
with grooving as directed
10 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected concealed in /flushed on wall/ceiling, with 1.5
sq. mm copper conductor FRLS PVC insulated stranded wire 870 100.00 Mtr 87000.00
of green colour for earth continuity of following size.(e) in
existing pipe.(b) 2 wire 2.5 sq. mm

11 Mains with 1.1 KV grade FRLS PVC insulated ISI marked


stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper 400 130 Mtr 52000.00
conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size.(e) in existing pipe.(a) 2
wire 4 sq. mm
12 Providing & Erecting approved make following size of TV Co-
axial flexible cable comprising inner conductor of solid bare
copper insulated with Foam PE & Secondary conductor
80 50.00 Mtr 4000.00
made of poly - Aluminium film bonded Al. Braids @ suitable
coverage overall sheathed with black PVC insulation.b).RG-
6
13 Providing & Erecting surface Mounting 120 cms long 18
watt LED Tubelight fitting with diffuser & electronic control
50 1200.00 No 60000.00
gear complete as per EON Company catlog No Eco LED or
equivalent
14 Providing & Erecting 320mm dia 12 Watt Surface Mounted
LED fitting with diffuser & Electronic control gear complete
15 1300.00 No 19500.00
as per EON Company Catlog No Deco LED 1006 or
Equivalent
15 providing & Erecting 180mm dia 6 watt surface Mounted
LED fitting with diffuser & electronic control gear complete
30 750.00 No 22500.00
as per EON company catlog No Deco LED 1011 or Equivalent
16 providing & Erecting 20 W LED Flood Light 6500k 180 mm x
140 mm complete Eqivalant to Syska Model No SSKBLS20W 6 3500.00 No 21000.00

17 Supplying & erecting fan hook box of 10 mm M.S. round


bar bounded to the RCC bars up to 50mm length each side
and pierced through a 16 Gauge M.S. box / Heavy Duty PVC 12 150 No 1800.00
box complete erected concealed in Ceiling with necessary
finishing.
18 Providing & erecting Approved make Power Saving 50 Watt
Ceiling Fan with double ball bearing ISI mark with
Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with , canopy & 30 12 2090.70 No 25088.40
cms. down rod erected with 24/ 0.2, 3 core flexible wire
with earthing.(Make shall be approved by Engineer in
charge))
19 Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
22 126.25 Mtr 2777.50
complete with necessary 24/ O.20, 3 core flexible wire with
earthing.
20 Providing 2.5mm.thick laminated acrylic sheet to cover the
42 20.20 No 848.40
fan hook or Fan box.
21 Providing & erecting fresh air fan 250 mm dia with square
1 1838.20 No 1838.20
frame make of ABS body with louvers
22 Providing 18/19mm thick ply wood for erection of Exhaust
fan complete covering the remaing portion of window/wall
1 250.00 No 250.00
complete with color washing to match the color of the wall

23 Providing & erecting weather proof, dust & vermin proof,


floor mounted front operated indoor type cubical panel
board having IP-64 protection made from 14 SWG thick CRC
M.S. sheet for outer body & doors, 16 SWG thick CRC
M.S.sheet for internal partitions with necessary supporting
angles, flats including cutting, bending, drilling, welding,
riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, with suitable
size of inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite control
fuses for measuring instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and rubber
gasket complete. The Panel shall be painted with epoxy
powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The dimension shall be
measured
exc���������������������������������������������
�����������������������������������������������
�������������
(A) The standard companies switch gear shall be used and only
manufacturers at CPRI approved factory and shall be certified by
that company whose switch gears are used after fabrication for
beneficial use
(i) with 350mm depth 0.5 17584.10 Sq.Mtr 8792.05
24 Providing Approved make Triple Pole Metal Clad Switch Fuse
Unit 415/500 V. with HRC fuse of suitable load and neutral link
confirming to IS
(a)200 A CAT III 1 9453.60 No 9453.60
25 Erection & connection Charges for 200A/ 250A/ 300 A /325 A HRC
TPN as following
(b)Erection on New angle iron frame duly painted with red oxide .
1 232.30 No 232.30
26 Approved make ELCBs / RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand
capacity of 6 KA and suitable for operation on 3 phase and
neutral 415V. having characteristic of quick action & 1 5090.40 No 5090.40
tripping with all advance feature & do not incorporate any
electronic component for following Max. rating erected as
directed.(iv) 100 Amps. FP (100 mA Sensitivity) CAT III

27 Supplying & fixing box for housing ELCB / ELCB + MCB


combination made of 18 SWG sheet steel duly powder
coated with gasket, dust & vermin proof bakelite shield two
earthing terminals for following type of RCCB, ELCB, ELCB +
MCB
[b] For 4 Pole 1 525.20 No 525.20
28 Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415 V. having
Normal current rating up to 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with 1 16665.00 No 16665.00
all internal connections & complete erected in existing 16
M.S.housing. ICS=100% of ICU only Cat III

29 Supplying and erecting triple pole & neutral 440V / 500V panel
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with
necessary connections.

(B) Suitable for 200 Amp. capacity 1 3030.00 Mtr 3030.00


30 Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 25 KA. at 415 V,having
normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply 2 6352.90 No 12705.80
50 c/s. with all internal connections & complete erected in
existing 16 G.M.S. housing.ICS=100% of ICU only Cat III
31 Mains with ISI marked , 1.5 KV grade electrolyte multi
stranded,annealed copper conductor with heat resistance PVC
insulated conforms to IS 694,IEC-227 erected in existing pipe of
following size(specifically for control panel,relays,power
switchgeras,motor starters & control wiring) with required size of
copper lugs,nuts and bolts if Required

one wire 1.00 Sq.mm 20 10.10 Mtr 202.00


one wire 16.00 Sq.mm 20 141.40 Mtr 2828.00
one wire 25.00 Sq.mm 20 237.35 Mtr 4747.00
32 S & E approved make panel mounting type Digital voltmeter
having 3 digit LED display. 0 to 750 Ac Volts range erected on
existing panel board with all connection,wirring etc. with 1 1504.90 No 1504.90
manufactures calibration certificate

33 S & E approved make panel mounting type Digital Ammeter


having 3 digit LED display. External CT operated, calibration
for 0 to 1000 Amps suitable to operate on 500 Volts 1 1838.20 No 1838.20
AC,erected on existing panel board with all
connection,wirring etc. with manufactures calibration
certificate
34 S & E Ammeter/Voltmeter selector Switch for 3 Phase AC Supply
500 V on existing panel board with necessary coonection 1 373.70 No 373.70

35 S & E approved make set of indicator lamps of LED type


lam,lens cover,bakelite holder complete erected with 1 126.25 No 126.25
necessary connection
36.A Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following
size of cables
(e) 4 core 25 Sq. mm 67 242.40 Mtr 16240.80
36.B Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench / 50 353.50 Mtr 17675.00
pipe of following size of cables.(B) 3 1/2 core 50 Sq. mm (
16 Sq. mm 1/2 core)
37 Providing and Erecting Annealed bare Copper wire 8 to 16
16.00 717.10 Kg 11473.60
SWG
38 Making a cable end termination in a proper way with
20 200.00 No 4000.00
tighness complete with insulating tap
39 Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-
Pipe Technology as per IS 3043-1987 made of corrosion free
G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive 2 9059.70 No 18119.40
compound with high charge dissipation suitable for
following type of applications.(b)For Electrical installation
up to 11 KV in normal soil.Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of 25 Kg.

40 Making trench in soft soil of suitable width of 90 cms deep


for laying cable or locating the fault all over the run and
35 40.40 Mtr 1414.00
backfilling the same and making the surface as normal
ground.
41 Covering of cable with second class bricks or cement tiles
laid cover the cable crosswise & also on both sides with
35 131.30 Mtr 4595.50
covering of 7. 5 Cms. layer of sand above & below cable (16
bricks per meter)
42 Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
making up to following size of holes at both ends complete.

(B) Up to 150 mm bore dia 7 505.00 Mtr 3535.00


43 Providing & laying ISI marked Rigid PVC pipe having 6Kg /
cm2 (Class-3) to be erected at road crossing on or floor as
directed for laying of cable. The pipes as following size of
dia & weight per 6 mtr.
43.A (A) 40 mm Dia. (1.68 Kg / 6 RMT) 9 60.60 Mtr 545.40
43.B (F) 110 mm Dia. (11.63 Kg/6 RMT) 27 277.75 Mtr 7499.25
44 making the Zari in wall by using cutter for erecting 40/50
mm dia PVC Pipe with wire mash jali before plastering 9 200.00 Mtr 1800.00
andmaking the surface as per orignal
45 Making the Brick Masonary chamber with plaster for size of
45x45x45 cms for cable entry complete filled with fine sand 1 505.00 No 505.00
&cover as per orignal floor tiles
46 Solderless crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.

(A) 1.5/ 2.5/4/6 Sq.mm 48 5.05 No 242.40


(D) 25 Sq mm 16 15.15 No 242.40
(E) 35/50 Sq.mm. 4 20.20 No 80.80
47 Miniature circuit breaker single pole 6A to 32A suitable to
operate on 240V A.C system and having breaking 10 KA to
be erected in existing box.confirming to IS 8828/1996 with 2 116.15 No 232.30
ISI Mark CAT III
48 Approved make ELCBs/RCCBs Conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand
capacity of 6KA and Suitable for operation on single phase
240V having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component for following Max. rating erected as directed

(ii) 40 Amps. DP CAT III 6 2636.10 No 15816.60


49 Supplying and erecting Sheet Steel Powder coated vertical
SS Double door per phase isolation (PPI) recess mounting
Distribution Board With Bus bar, neutral Din rain Complete.

(2) 3 phase 8 way 2 5000.00 No 10000.00


50 Supplying and erecting Sheet Steel Powder coated cable
end termination Box to be mounted on top or bottom of
MCB Distribution Box for Housing/Covering extra wire &
Cables,suitable for following size of MCB DB Box

(G) Three phase 8 Way 2 656.50 No 1313.00


51 Providing & erecting open well horizontal mono block pump
set with cast iron body, complete for three phase
submersible motor having[C] For 3 HP 3 phase open well 1 14099.60 No 14099.60
horizontal mono block pump set suitable for 85 LPM to 270
LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia
delivery pipe CAT III
52 Supplying and erecting Direct - On - Line Starter with 18 A.
rating contactor and with 3.5 Amp. 18A range directly
operated in totally insulated elegant enclosure for single 1 1868.50 No 1868.50
phase operation up to 3 HP as per IS 13947 complete
erected on P.W. Block with necessary connection. CAT
III
53 Providing & Erecting ISI marked PVC insulated PVC Sheated
flat Flexible submersible copper cable approved make of
following size
(b) 3 core x 2.5 Sq.mm 70 110.00 Mtr 7700.00
54 S & E 1.5 Inch/2 Inch G.I Nippul, Reducer, Flexible hose pipe
with necessary clamp as per requirment for making
1 1000.00 Set 1000.00
connection between pump outlet and existing outgoing PVC
water supply Line.
55 Providing , erecting , fabricating the M.S. structure as per
requirement on site incorporating proper size of M.S.
angles, flats, bars, channels, sections complete with cutting,
welding, grinding & finishing duly painted with one coat of 68 70.70 Kg 4807.60
red oxide with erection on site as per direction of engineer
in charge with necessary grouting, cementing, plastering &
finishing complete.

Total Rs 630842.75
IDER NAGARPALIKA IDER
Construction Gym Center Building from Idariya Shila Udhyan Near At Idar
Nagarpalika Idar

SHEDULED - B
2015 -16 R & B

I.No Quantity Description Total rate Unit Amount in Rs.

Providing and laying (to level or slopes) and jointing with


stiff mixture of Cement Mortar in proportion 1:1 Selt glazed
1 100.00 207.01 Rmt 20701.00
stoneware pipes including testing of pipes and joints
complete.(B) 150mm dia. (upto 10 ton)
Providing and fixing wall mounted wash down European
Water Closet-P of approved shade, conforming to Pattern 2
of IS: 2556 (Part -II), with SWR Self fit Soil PVC pipe and
plug bend as per specifications; glazed vitreous / Cloured
European Water Closet with Cistern (IS-2326), with
grouting the CI chair inside the floor/wall, rubber gaskets,
connecting PVC 110mm dia soil pipe with PVC coupling,
nuts, mounting cistern on WC., and solid varity heavy duty
plastic seat cover as per IS-2548, of approved make;
including all costs for cutting wall and floor and making
2 5.00 good the damages etc. and fixing with necessary fittings etc. 7878.00 Each 39390.00
complete. ( Cera/ Hindware Make)EWC-P : CERA CLAIR
WHITE WALLHUNG EXTENDED 'P' NO.2033CISTERN : HIGH
LEVEL COMMANDER PNEUMATIC FLUSH TANK WHITE
10ltr. FlushSEAT COVER : CERA CLAIR WHITE SOFT CLOSE
TYPE NO.2315OULET GASKET:- CERA 2433INLET GASKET:-
CERA 2533CHAIR BRACKET:- 2432ANGULAR COCK-
JAQUAR-SUMTHING SPECIAL-SS526

Providing and fixing washbasin with single hole for pillar


tap with C.I. or M.S. brackets painted white including sutting
holes and making good the same but excluding fittings.(A)
Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm
size. (i) In white colour. CERA COUPE WHITE NO.1045A
3 5.00 918.82 Nos 4594.10
(Cera/Parryware Makes)BOTTEL TRAP : (With Internal
Partition)JAQUAR/ WASTE COUPLING : (HALF
THREAD)JAQUAR MAKESPRASS MATIC WALL MOUNTING
TAP:- JAQUAR MAKE
Constructing sock well of 3.00 M. outside diameter & 5.00 M.
deep B.B.C.C. 1:5:10 at botttom in 0.15 m thickness having
23 Cms. Thick solid B.B. Masonary walls in C.M. 1:6 in 0.50
M. hight at top & bottom 4.00 M. hight honey combing
4 1.00 masonary in C.M. 1:6 and making top cover of jodhpuri patti 37581.48 Each 37581.48
incl. filling joints & 15 Cms thick cement plaster outer face
upto 0.60 M. depth and filling the well with brick bats 40
mm nominal size upto 5.00 M. depth etc as directed.

Providing & fixing white vitreous china flat back urinal of


size 590x375x390mm as per IS-2556 (Part-2 ) with C.I.
hangers and 15mm dia. C.P. spreader,32mm dia CP bottle
trap and pipe to wall with C.P. flange complete including
cutting and making good the walls and floors wherever
5 8.00 required.(Cera/ Hindware Make) FLAT BACK LARGE 2525.00 Each 20200.00
URINAL : 5004 CERA WHITE (MENS) BOTTEL TRAP : (With
Internal Partition)JAQUAR/ WASTE COUPLING : (HALF
THREAD)JAQUAR MAKES CONCEALED STOP COCK: JAQUAR
SUMTHING SPECIAL)SS514E

Providing & fixing of health faucet, with 8mm Dia,1.2 Rmt


Long pvc Tube and accessories with necessary fittings etc.
6 5.00 complete. HEALTH FAUCET : KOHLAR MAKE. 12927 606.00 Nos 3030.00
no.ANGULAR COCK-JAQUAR-SUMTHING SPECIAL-SS526

Providing & fixing in position 15 mm C.P. brass bib cocks of


7 15.00 best quality with necessary fittings etc. complete. BIB COCK : 454.50 Nos 6817.50
JAQUAR SUMTHING SPECIAL SS511
Providing & fixing towel rail of approved make including,
providing & fixing C.P. brass screws, making holes in walls
8 2.00 573.68 Nos 1147.36
& making good. Size 600 mm x 20 mm dia (JAQUAR/
KHOLAR MAKES CONTI - 1111 - CP)
Providing and fixing grab bar fabricated from 32mm dia
seamless stainless steel tube 2mm thick in bath room with
9 3.00 non slip gripping surface, polished wall flange at end of bars 606.00 Nos 1818.00
with heavy duty anchor fasteners & accessories.GRAB BAR :
JAQUAR - HOTELIER ACC - 1501 - CP
Providing & fixing of Double coat hook , with all accessories
10 5.00 to complete the item.ROBE HOOK : JAQUAR MAKES - 353.50 Nos 1767.50
CONTINENTAL - ACC - 1191 - CP
Providing and fixing S.S. 304 full bore ball valve of approved
11 2.00 quality(screwed end ) ( Audco Make)INTERNAL TOILET 156.80 Nos 313.60
WATER CONTROL VALVE:-25 mm
Providing & fixing in position best Indian make toilet
recessed type paper holder complete in all respects
12 2.00 1863.45 Nos 3726.90
including cutting and making good the walls etc. TOILET
PAPER : JAQUAR MAKES - ACC - 1553 - CP
Providing & fixing C.P. brass liquid soap container of best
13 2.00 858.50 Nos 1717.00
quality.JAQUAR/ CERA/ HINDWARE MAKES
Providing and fixing chromium plated brass half trun flush
14 2.00 cock of approved quality including fixing in pipe line etc. 311.25 Nos 622.50
complete.(ii) 25mm dia.
Providing and fixing C.P. brass shower rose with 15mm or
15 6.00 324.94 Nos 1949.62
20mm inlet.(A) 100mm dia. Each
Providing and fixing 13mm thk. EPDM Sheet for Gymnasium
16 167.00 2323.00 Nos 387941.00
room flooring as directed by Engineer-In-Charge
godrej lockers
Armour Mechanical Safe Wardro Series High Precision
Dimple Key Lock - Material: Metal - Colour: Ivory(Powder
17 16.00 Coated) - 3 Months Warrant Pry Resistant with concealed 6060.00 Nos 96960.00
hinges - Twin Bolt Locking Approx. wt. 18 kg - One
Removable Shelve. - Holes at Bottom and Back for Fitting

Total Amount 630277.57

S-ar putea să vă placă și