Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor - Abnormal Rate of Change
Fault Code: 4769 Aftertreatment 1 Diesel Exhaust Possible reduced engine performance.
PID(P), SID(S): Fluid Tank Level Sensor -
SPN: 1761 Abnormal Rate of Change. A
FMI: 10/10 valid diesel exhaust fluid tank
Lamp: Amber level reading has NOT been
SRT: received.
Circuit Description:
The aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level
inside the aftertreatment diesel exhaust fluid tank.
Component Location:
The aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank.
Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 21-Aug-2017
File: 176-fc4769 Page 2 of 3
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Shop Talk:
Possible causes of this fault code include:
A malfunctioning aftertreatment diesel exhaust fluid tank level sensor
Tampering of the aftertreatment diesel exhaust fluid tank level sensor