Documente Academic
Documente Profesional
Documente Cultură
Rainscreen cladding systems are commonly used to give a A drained and ventilated facade (rainscreen) is designed to drain
greater degree of aesthetics and design abilities to a building or any moisture within the façade construction efficiently whilst
structure, allowing the designers more freedom and flexibility maintaining a positive airflow, protected from direct weather
with there design concepts. exposure and sunlight the façade allows the building to achieve
the highest possible efficiency.
Whilst rainscreen cladding systems exhibit numerous advantages
with regards to building physics, the underlining problem with an As a positive airflow is a necessary requirement for a rainscreen
‘Open state’ cavity system is achieving good compartmentation. system the ventilation gap poses a potential problem which will
allow the fire to spread rapidly across the building envelope.
Internal Corner
300 mm max.
Note: Stated positions are examples and subject to actual design and building codes
Technical details
Fire performance
fischer FFB VS VentiStop ‘Open state’ horizontal cavity fischer FCFcl Cavity Clad has been designed for
barriers consist of a non-combustible stonewool core, which rainscreen cladding to full fill the void between the external
is encased in a reinforced aluminium foil scrim. A continuous envelope and the fabric of the building. By fully sealing
powerful intumescent graphite strip is bonded to the exposed the void, they assist ventilated facades to function by
face and pre-wrapped with a durable polythene adhesive sheet to maintaining air-pressurisation and compartmentation.
prevent water ingress. A unique one piece closed dimension stone wool core
Under fire condition, the powerful intumescent graphite strip provides a resilient lateral compression and commodate
rapidly expands horizontally to fully close the ventilation gap the serviceability movement normally associated with
designed and formed at time of installation. rainscreen facades.
This unique component offers excellent resistance to both fire and Encased with an aluminium foil face scrim to provide
smoke. class ‘O’ reaction to fire rating and provides excellent
resistance to smoke and weathering.
fischer FFB VS VentiStop ´Open state´ horizontal cavity fischer FCFcl Cavity Clad ´Closed state´ horizontal
barriers have been successfully tested up to 60 minutes & Vertical cavity barriers have been successfully tested
integrity and 60 minutes Insulation, utilising the general up to 120 minutes integrity and 120 minutes Insulation,
principles of BS 476: Part 20: 1987, and 90 minutes integrity utilising the general principles of BS 476: Part 20: 1987,
and 30 minutes insulation utilising the heating and pressure and 120 minutes integrity and 120 minutes insulation
conditions of EN 1363-1: 2012 and ASFP TDG 19: 2014 – utilising the heating and pressure conditions of EN1366-4:
Open state Cavity Barriers used in External Envelope or Fabric 2012 and ASFP TDG19: 2014 – Open State Cavity Barriers
of Buildings. used in External Envelope or Fabric of Buildings.
SPECIFICATIONS FFB-VS
To suit cavity void width Colour Fire rating (Min.) Sales unit
Item Art.-No. [mm] [pcs]
FFB-VS/25-50 521520 25 - 50 Red/silver/black 90 48
FFB-VS/51-100 521521 51 - 100 Red/silver/black 90 24
FFB-VS/101-150 521522 101 - 150 Red/silver/black 90 48
FFB-VS/151-200 521523 151 - 200 Red/silver/black 90 14
FFB-VS/201-250 521524 201 - 250 Red/silver/black 60 11
FFB-VS/251-300 521525 251 - 300 Red/silver/black 60 11
FFB-VS/301-350 521526 301 - 350 Red/silver/black 60 TBA
FFB-VS/351-400 521527 351 - 400 Red/silver/black 60 9
FFB-VS/401-450 521528 401 - 450 Red/silver/black 60 6
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be.
SPECIFICATIONS FFB-VS / 50
To suit cavity void width Colour Fire rating Sales unit
Item Art.-No. [mm] [pcs]
FFB-VS/50 - 51-100 545628 51 - 100 Red/silver/black 60 24
FFB-VS/50 - 101-150 545629 101 - 150 Red/silver/black 60 48
FFB-VS/50 - 151-200 545630 151 - 200 Red/silver/black 60 14
FFB-VS/50 - 201-250 545631 201 - 250 Red/silver/black 30 11
FFB-VS/50 - 251-300 545632 251 - 300 Red/silver/black 30 11
FFB-VS/50 - 301-350 545633 301 - 350 Red/silver/black 30 TBA
FFB-VS/50 - 351-400 545634 315 - 400 Red/silver/black 30 9
FFB-VS/50 - 401-450 545635 401 - 450 Red/silver/black 30 6
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be.
XXXXXX (1)· 04/2019 · V-MKS/ST · Printed in Germany · We reserve the right to make technical modifications.
Qualified technical consulting for economical and compliant fastening
solutions. Also on-site at the construction site if requested.
Training sessions, some with accreditation, at your premises or at the
fischer academy.
Design and construction software for demanding applications.