Sunteți pe pagina 1din 6

fischer FireStop

Solutions for Rainscreen


Cladding Systems
Design for use in the external
building envelope

Rainscreen claddings can be a high risk for fire spread

Rainscreen cladding systems are commonly used to give a A drained and ventilated facade (rainscreen) is designed to drain
greater degree of aesthetics and design abilities to a building or any moisture within the façade construction efficiently whilst
structure, allowing the designers more freedom and flexibility maintaining a positive airflow, protected from direct weather
with there design concepts. exposure and sunlight the façade allows the building to achieve
the highest possible efficiency.
Whilst rainscreen cladding systems exhibit numerous advantages
with regards to building physics, the underlining problem with an As a positive airflow is a necessary requirement for a rainscreen
‘Open state’ cavity system is achieving good compartmentation. system the ventilation gap poses a potential problem which will
allow the fire to spread rapidly across the building envelope.

Complete system from one source


fischer SystemTec offers a complete system approach, designed anchors, and a unique fire barrier system all meeting the highest
supporting anchors, a light weight framing system which consist safety requirements.
of support brackets, vertical and horizontal profiles, cladding support
Achieving compartmentation
in a building envelope

‘Open state‘ horizontal cavity barriers


fischer FFB VS VentiStop
Can provide up to a 50 mm ventilation gap behind the façade panel.
In the event of a fire, the gap will be closed by a powerful and spe-
cially formulated intumescent strip expanding.

Horizontal Cavity Barrier Vertical Cavity Barrier


External Corner
To all compartment floors At max. 600 mm centres
300 mm max.
(NB: max. 300 mm from corners)

Internal Corner
300 mm max.

Vertical Cavity Barrier Barrier


At edge of cavity To surround all openings

‘Closed state‘ verticle cavity barrier


fischer FCFcl Cavity Clad
Compartmentalizes vertically. It assists by helping ventilated facades to function by
maintaining air-pressurization and compartmentation.
The above is an example of barrier placement. Local or national building codes
should be consulted in design.

Note: Stated positions are examples and subject to actual design and building codes
Technical details

Fire performance

fischer FFB VS VentiStop ‘Open state’ horizontal cavity fischer FCFcl Cavity Clad has been designed for
barriers consist of a non-combustible stonewool core, which rainscreen cladding to full fill the void between the external
is encased in a reinforced aluminium foil scrim. A continuous envelope and the fabric of the building. By fully sealing
powerful intumescent graphite strip is bonded to the exposed the void, they assist ventilated facades to function by
face and pre-wrapped with a durable polythene adhesive sheet to maintaining air-pressurisation and compartmentation.
prevent water ingress. A unique one piece closed dimension stone wool core
Under fire condition, the powerful intumescent graphite strip provides a resilient lateral compression and commodate
rapidly expands horizontally to fully close the ventilation gap the serviceability movement normally associated with
designed and formed at time of installation. rainscreen facades.
This unique component offers excellent resistance to both fire and Encased with an aluminium foil face scrim to provide
smoke. class ‘O’ reaction to fire rating and provides excellent
resistance to smoke and weathering.

fischer FFB VS VentiStop ´Open state´ horizontal cavity fischer FCFcl Cavity Clad ´Closed state´ horizontal
barriers have been successfully tested up to 60 minutes & Vertical cavity barriers have been successfully tested
integrity and 60 minutes Insulation, utilising the general up to 120 minutes integrity and 120 minutes Insulation,
principles of BS 476: Part 20: 1987, and 90 minutes integrity utilising the general principles of BS 476: Part 20: 1987,
and 30 minutes insulation utilising the heating and pressure and 120 minutes integrity and 120 minutes insulation
conditions of EN 1363-1: 2012 and ASFP TDG 19: 2014 – utilising the heating and pressure conditions of EN1366-4:
Open state Cavity Barriers used in External Envelope or Fabric 2012 and ASFP TDG19: 2014 – Open State Cavity Barriers
of Buildings. used in External Envelope or Fabric of Buildings.

British Standard BS EN 1366-4: 2006


BS 476-20: 1987 ETA-17/0448
0843-CPR-0361 BS EN ISO 10140-3: 1995
BS EN 1363-1-TG19
British Standard BS EN 1026
BS 476-20
Product specifications

SPECIFICATIONS FFB-VS
To suit cavity void width Colour Fire rating (Min.) Sales unit
Item Art.-No. [mm] [pcs]
FFB-VS/25-50 521520 25 - 50 Red/silver/black 90 48
FFB-VS/51-100 521521 51 - 100 Red/silver/black 90 24
FFB-VS/101-150 521522 101 - 150 Red/silver/black 90 48
FFB-VS/151-200 521523 151 - 200 Red/silver/black 90 14
FFB-VS/201-250 521524 201 - 250 Red/silver/black 60 11
FFB-VS/251-300 521525 251 - 300 Red/silver/black 60 11
FFB-VS/301-350 521526 301 - 350 Red/silver/black 60 TBA
FFB-VS/351-400 521527 351 - 400 Red/silver/black 60 9
FFB-VS/401-450 521528 401 - 450 Red/silver/black 60 6
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be.

SPECIFICATIONS FFB-VS / 50
To suit cavity void width Colour Fire rating Sales unit
Item Art.-No. [mm] [pcs]
FFB-VS/50 - 51-100 545628 51 - 100 Red/silver/black 60 24
FFB-VS/50 - 101-150 545629 101 - 150 Red/silver/black 60 48
FFB-VS/50 - 151-200 545630 151 - 200 Red/silver/black 60 14
FFB-VS/50 - 201-250 545631 201 - 250 Red/silver/black 30 11
FFB-VS/50 - 251-300 545632 251 - 300 Red/silver/black 30 11
FFB-VS/50 - 301-350 545633 301 - 350 Red/silver/black 30 TBA
FFB-VS/50 - 351-400 545634 315 - 400 Red/silver/black 30 9
FFB-VS/50 - 401-450 545635 401 - 450 Red/silver/black 30 6
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be.

SPECIFICATIONS FCFCL AND ACCESSORIES


To suit cavity void width Colour Fire rating Sales unit
Item Art.-No. [mm] [pcs]
FCFcl 75 546210 1200 x 600 x 75 silver Up to 2* 1
FCFcl 100 053046 1200 x 600 x 100 silver Up to 2* 1
FCFcl 1200 546209 1200 x 1200 x 100 silver Up to 2* 1
Multi Purpose Bracket 505248 390 x 25 x 2 1
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be.
FCFcl Cavity Clad shall be cut 10 mm (3/8 in.) over size.
* Depending on design & configuration of the FCFcl Cavity Clad.

SPECIFICATIONS DHM ANCHOR


Hot-dip Stainless Drill hole diameter Min. drill hole Effect. anchorage Anchor length Usable length Sales unit
Approval

galvanised steel depth depth


steel A2
d0 h1 hef l tfix
Art.-No. Art.-No. DIBt [mm] [mm] [mm] [mm] [mm] [pcs]
Item hdg A2
DHM 40 536253 536262 ▯ 8 50 40 80 10 - 40 250
DHM 70 536254 536264 ▯ 8 50 40 110 40 - 70 250
DHM 100 536256 536265 ▯ 8 50 40 140 70 - 100 250
DHM 130 536257 536266 ▯ 8 50 40 170 100 - 130 250
DHM 160 536258 536267 ▯ 8 50 40 200 130 - 160 250
DHM 210 536259 536268 ▯ 8 50 40 250 170 - 210 125
DHM 260 536260 536269 ▯ 8 50 40 300 220 - 260 125
DTM 80 536261 536271 ▯ — — — — — 250
fischer FIXPERIENCE
The design and information software suite
 The modular design program includes engineering software and
application modules.
 The software is based on international design standards (ETAG 001,
EC1, EC2, EC3 and EC5), including the national application documents.
All common force and measurement units are available.
 Incorrect input will be recognized and the software gives tips to get a
correct result. This ensures a safe and reliable design every time.
 The graphical display can easily be rotated through 360°, panned, tilted
or zoomed as required.
 The 3D display gives a detailed and realistic image.
 The “live update” feature helps to keep the program up to date ensuring
you are always working with the latest version.
 Free download and updates at www.fischer.de/fixperience-en

Our service to you


We are available to you at any time as a reliable partner to offer technical
support and advice:
 Our products range from chemical resin systems to steel anchors through
to nylon anchors.
 Competence and innovation through own research, development and
production.
 Global presence and active sales service in over 100 countries.

XXXXXX (1)· 04/2019 · V-MKS/ST · Printed in Germany · We reserve the right to make technical modifications.
 Qualified technical consulting for economical and compliant fastening
solutions. Also on-site at the construction site if requested.
 Training sessions, some with accreditation, at your premises or at the
fischer academy.
 Design and construction software for demanding applications.

This is what fischer stands for

FIXING SYSTEMS AUTOMOTIVE SYSTEMS FISCHERTECHNIK CONSULTING LNT AUTOMATION

See the extensive main catalogue or visit our website at www.fischer-international.com


for information about the complete fischer range

fischerwerke GmbH & Co. KG


Klaus-Fischer-Straße 1 · 72178 Waldachtal
Germany
Tel. +49 7443 12-0 · Fax +49 7443 12-4220
www.fischer.de · info@fischer.de

S-ar putea să vă placă și