TOP BARS // TO RIB

BEAM
TOP BARS L TO RIB CENTERLINE
BOTTOM BARS L TO RIB

SLAB THICKNESS
(SEE SLAB SCHEDULE)
BOTTOM BARS // TO RIB

RC BEAM RC BEAM
(SEE BEAM SCHEDULE) (SEE BEAM SCHEDULE)

ARRANGEMENT OF
ADDITIONAL REINFORCEMENT ORIENTATION OF HOOKED BAR
RELATIVE TO BEAM CENTERLINE

RIB MEAN WIDTH


wr ≥ 50 mm ≥ 40 MM

SLAB THICKNESS ≥ 50 MM
(SEE SLAB SCHEDULE) Hs
RIB HEIGHT hr ≤ 75 MM

Hs 2 ROWS OF 12 MM F
HOOKED BAR @ 0.30 M O.C.

RC BEAM
(SEE BEAM SCHEDULE)

TYPICAL DETAIL OF HOOKED BAR


USED AS SHEAR CONNECTOR

STEEL DECK TYPICAL DETAILS


(NOT OT SCALE)