– GS 1207:2018
QUALIFICATION
PART 30: PLUMBING SYSTEMS
● 30.4–WATER SUPPLY
– 70-100L PER HEAD FOR RESIDENCES
– FOR PLANNING PURPOSES: 150-200LPHD
– ASSUME 45LPHD IS FOR FLUSHING
– TABLE AVAILABLE FOR NON DOMESTIC
REQUIREMENTS
– NON-DRINKING WATER MUST STILL BE FREE FROM
BACTERIA (STILL POTABLE)
– RECLAIMED WATER MUST BE USED FOR ONLY NON-
DOMESTIC PURPOSES
PART 30: PLUMBING SYSTEMS
● 30.4–WATER SUPPLY
– TANK REQUIREMENTS (30.4.3)
● TANK SIZING, USE POPULATION DENSITY.
FIXTURES
PART 30: PLUMBING SYSTEMS
● 30.4–WATER SUPPLY – DESIGN
– NO CONNECTION TO MAINS WITHOUT APPROVAL
OF GWCL
– PROVIDE SUITABLE COVER FOR UNDERGROUND
PIPES
– PROVIDE STOP VALVES ON EACH BRANCH TO
DIFFERENT ZONES IN OCCUPIED SPACE.
– IN-LINE PUMPS ON SERVICE LINES NOT ALLOWED.
– SUPPORT, NOISE CONTROL, AND CORROSION
CONTROL.
PART 30: PLUMBING SYSTEMS
● 30.4–WATER SUPPLY – DESIGN
– NO SERVICE PIPE SHOULD BE CONNECTED TO
DISTRIBUTION PIPE.
– USE BACKFLOW PREVENTERS WHEN NECESSARY
– PIPE SHOULD NOT BE LAYED THROUGH LAND FILL,
REFUSE, ASHPIT, SEWER, DRAIN, CESSPOOL, REFUSE
CHUTE OR MANHOLE.
– NO PIPE SHOULD BE EXPOSED TO AGENTS THAT
CAUSE IT TO DETERIORATE
SOME CODES ON DESIGN INCONSISTENT WITH CURRENT
INTERNATIONAL PRACTICES.
PART 30: PLUMBING SYSTEMS
● 30.5–DRAINAGE PRELIMINARY DESIGN
REQUIREMENTS
– SITE PLAN. DRAINAGE PLAN. USE. NATURE OF
WASTE.
– SEWERS.
– COVER.
– SUB SOIL CONDITIONS.
– LOCATION OF OTHER SERVICES.
PART 30: PLUMBING SYSTEMS
● 30.5–DRAINAGE PRELIMINARY DESIGN
REQUIREMENTS
– AVOID POSSIBILITY OF CROSS CONTAMINATION
WHENEVER POSSIBLE.
– VENT! VENT! VENT!
– DO NOT MIX RAIN WATER AND SOIL PIPES
– GREASE TRAPS MUST BE INSTALLED WHEN
NECESSARY