LST UCELLCAC:CELLID=30063,LSTFORMAT=VERTICAL;

141182.RNC_01.HW.KEZIRATEL.Dire.ER
+++ RNC_01_DD 2019-12-19 16:04:11
O&M #2100171
%%/*1891246*/LST UCELLCAC: CELLID=30063,LSTFORMAT=VERTICAL;%%
RETCODE = 0 Execution succeeded.

List Cell Oriented CAC Algorithm Parameters


-------------------------------------------
Logical RNC ID = 107
Cell ID = 30063
Cell Name =
SWAP_141006_H2_AC_DG_WL_GDU_BSC02RNC.DIRLEGHAR.Diredawa.ER_U13
Cell environment type = TU
UL threshold of Conv AMR service = 75
UL threshold of Conv non_AMR service = 75
UL threshold of other services = 60
DL threshold of Conv AMR service = 85
DL threshold of Conv non_AMR service = 85
DL threshold of other services = 83
UL handover access threshold = 80
DL handover access threshold = 87
UL total power threshold = 95
DL total power threshold = 90
UL common channel load reserved coefficient = 0
DL common channel load reserved coefficient = 0
DL neighbour interference factor = 60
UL total equivalent user number = 200
DL total equivalent user number = 80
HSUPA Non-Server cell interfere factor = 0
Low priority HSUPA user PBR threshold = 100
Equal priority HSUPA user PBR threshold = 100
High priority HSUPA user PBR threshold = 100
UL HS-DPCCH reserve factor = 0
Hsdpa streaming PBR threshold = 70
HSDPA best effort PBR threshold = 30
Maximum HSDPA user number = 64
Max UL TX power of conversational service = 24
Max UL TX power of streaming service = 24
Max UL TX power of interactive service = 24
Max UL TX power of background service = 24
Background noise = 61
RRC Proc SRB delay = 0
RRC Proc DPCCH PC preamble length = 7
HHO Proc SRB delay = 7
HHO Proc DPCCH PC preamble length = 7
Default PCPICH Ec/No = -13
Auto-adaptive background noise update switch = ON
Background noise filter coefficient = 5
Background noise update continuance Time = 120
Equivalent user number threshold for background noise = 0
Initial power offset for SHO = 15
Maximum HSUPA user number = 20
Dl HSUPA reserved factor = 0
DL MBMS reserved factor = 0
MTCH reserve power = 20
MTCH reserve SF = 16
MTCH maximal power = 60
MTCH maximal SF = 40
UL handover credit reserved SF = SF16
DL handover credit and code reserved SF = SF32
Background noise update start time = 01:00:00
Background noise update end time = 06:00:00
Background noise update trigger threshold = 5
Background noise abnormal threshold = 100
Maximum EFACH user number = 300
PTT User Srb Delay = 0
PTT User DPCCH PC preamble length = 4
Cell Uplink Capacity of Equal User Number = 40
Called AMR Successful Rate Threshold Using HO Resources = 95
Maximum ERACH user number = 300
Power Resource Reserved for Free Users = 20
Threshold of Maximum Guaranteed Bit Rates for HSDPA = 100
Threshold of Maximum Guaranteed Bit Rates for HSUPA = 100
Non-HSPA Power Threshold for GBP-based Preemption = 30
RT Service RRC CAC Power Thd Offset = 5
Non-RT Service RRC Power CAC Thd Offset = 5
Other Service RRC Power CAC Thd Offset = 0
UL IC LDC Optimized Switch = OFF
DL Credit and Code Reserved SF for RRC = SF128
UL Credit Reserved SF for RRC = SF64
Optimal Background Noise Update Switch = OFF
Background Noise Update UL Load Thres = <NULL>
Carrier Load Balancing Ratio = 100
Target RoT for UL Total ENU Adjustment = 200
Dynamic Adjustment Factor for Max. HSUPA User = 100
UL NRT RRC CE Reserved SF = SF32
DL NRT RRC CE and Code Reserved SF = SF64
UL Other RRC CE Reserved SF = SF64
DL Other RRC CE and Code Reserved SF = SF128
Background Noise Persistence Switch = ON
Initial PO of the RL in the Non-Best Target Cell = 10
Admission Threshold of Non-Best Cell = 70
UL CE Resources Reserved by Non-Best Cell = SF8
DL CE/Code Resources Reserved by Non-Best Cell = SF16
DL Load Threshold for Other Services = 70
(Number of results = 1)