Documente Academic
Documente Profesional
Documente Cultură
Process Calibration
Tools CATALOGUE
Electrical, Multifunction,
and mA Loop Calibration
Pressure Calibration
Temperature Calibration
Data Acquisition
Process Calibration
Precision, performance, confidence.™
Why Calibrate?
The need to achieve consistent results is one of the most
important reasons why we calibrate.
Accuracy is an important feature of a calibrator. You may
need a particular level of accuracy to comply with standards
that specify a test accuracy ratio (TAR) or test uncertainty
ratio (TUR). For example, many standards require a 4:1 ratio
between the specified tolerance of the device under test (DUT)
and the accuracy or uncertainty of the calibration equipment.
However, accuracy is also important because when accurate
standards are used most of the time, downtime only needs
to be long enough to verify that the instruments are still in
tolerance. However, with inaccurate calibration standards,
more borderline and out-of-tolerance indications are found.
This means that a routine verification turns into an additional
adjustment procedure and a final verification at each of the test
points to prove the “as left” condition is in tolerance. This more
than doubles the downtime and the technician time involved
in completing the calibration. This is because inaccurate
standards tend to not be consistent with each other causing us
to make more adjustments to correct phantom errors.
What issues do you face? What issues do you face? What issues do you face? What issues do you face?
• Ensuring continuous uptime • Complying with quality • Making accurate measurements • Monitor and maintain sensors
regulations • Documenting procedures and transmissions
• Maintaining good ROI for
equipment • Maintaining documentation of • Increasing throughput • Accurate measurements
processes
• Compliance
• Process improvement
• Increase efficiency
mA Loop Precision
Process Calibrators
Calibrator Multimeter
Process Calibration
Solutions Tes
t Too
ls C 20
og ue
atal14/2015
Learn more
Fluke Process Calibration
Solutions at
http://au.fluke.com/PCT
2014
-20
P ro 15
Based on you. Built by Fluke T oolc e s s C a
s CATALO li br
a
G t ion
Electr
and ica
mA l, Multifu
Loo
p Ca nction
libratio ,
Pressu n
re Ca
libratio
Tem n
peratu
re Ca
libratio
n
Data
Acq
uisitio
24 Process Calibration
Process ToolsTools
Calibration
n
SOLUTIONS
* Diagram is not intended to be an exact representation. Diagram components are not to scale and are for illustration purposes only.
46 Process Calibration
Process ToolsTools
Calibration
Process Calibration Tools
From Fluke and Fluke Calibration
Working in a process environment such as pharmaceutical,
refining or other industrial areas can be challenging.
Whether you’re working at a bench, out in the plant, or in
the field, you need accurate tools that you can count on.
Finding the right tools for the specific challenges you face every
day is important so we’ve provided an “at-a-glance” guide to the
wide range of multifunction, mA loop, pressure and temperature
calibrators that we carry. For complete information on our
field and bench solutions to all your calibration needs visit
http://au.fluke.com/PCT or one of the product pages listed in
this catalogue.
mA Loop Calibration
Loop calibrators are essential tools for working with 4-20
mA current loops. Fluke loop calibrators provide mA sourcing,
simulation and measurement, readouts in both mA and % of
span, 24 V loop supply, simple operation and accuracy you
can count on.
Pressure Calibration
Instrumentation is found in virtually every process plant.
Periodic calibration of these instruments is required to keep
plants operating efficiently and safely. Fluke provides a wide
selection of field and bench calibration tools to help you
quickly and reliably calibrate your pressure instrumentation.
Temperature Calibration
Temperature calibration refers to the calibration of
any device used in a system that measures temperature—
from sensors to transmitters to displays. Fluke offers bench
and field solutions to ensure process temperature accuracy
of not only the system’s electronic temperature signals, but
also the very temperature sensors that initiate those signals.
Process Calibration
Process ToolsTools
Calibration 5
6
Process Calibration Tools
27 29 Thermistors................................... 26
Secondary Reference Thermistor
Probes........................................................ 26
Data Acquisition System.................28 Software.........................................30
Hydra Series III DAS/Digital 750 SW DPC/TRACK2 Software™ ............30
Multimeter..................................................28 700G/Track Logging Software................30
Super-DAQ Precision Temperature LogWare.......................................................30
Scanner.......................................................28
Extra Universal Input Module.................28
• Measure volts, mA, RTDs, thermocouples, • Measure volts, mA, RTDs, thermocouples,
frequency and ohms to test sensors, frequency and ohms to test sensors,
transmitters and other instruments transmitters and other instruments
• Source/simulate volts, mA, thermocouples, • Source/simulate volts, mA, thermocouples,
RTDs, frequency, ohms and pressure to RTDs, frequency, ohms and pressure to
calibrate transmitters calibrate transmitters
• Supports popular models of HART • Power transmitters during test using loop
transmitters, with more device-specific supply with simultaneous mA measurement
command support than any other HART • Download procedures and upload
field calibrator calibration results from field calibrations
• Download procedures and upload • NIST traceable calibration
calibration results from field calibrations www.fluke.com/au/753
• NIST traceable calibration
www.fluke.com/au/754
Complete Solution
Fluke 754 with 914X Series Field Metrology Well
Field checking a
loop-powered isolator
Fluke loop calibrators have a unique
current simulation feature that, when
connected to an external power
source, allows you to precisely control
current between 0 mA and 24 mA.
When field checking a loop-powered Testing valve positioners
isolator, the two-wire loop transmitter
supplying signal current to the isolator Electronic valve positioners should receive
for the loop may be removed and the periodic in-field calibrations as part of
calibrator connected in simulate mode preventive maintenance programs. Fluke
to control loop current. loop calibrators are the ideal test tools
for these checks. Valve positioners vary
in design and valve type and should
be calibrated using specific instructions
from the individual manufacturer. Quick
operational checks can be performed
using a field calibrator as a signal source
while observing the valve stem position,
mechanical position indicators or flow
indicators as input changes are made.
Fluke loop calibrators provide a convenient
source for simulating the controller output
to a valve positioner.
12
Pressure
Calibration
ProcessCalibration
Process Calibration Tools
Tools 13
14
14
Digital Pressure Calibrators
Built-in features like mA measure, loop power, switch test and transmitter error
calculation make these pressure calibrators powerful tools that are easy to use.
14 Pressure Calibration
Pressure Accessories
Get an outstanding value with our most popular accessories.
www.fluke.com/au/process_acc
Pressure Calibration 15
Master Gauges and Reference
Pressure Calibrators
Portable, high-quality pressure calibrators and precision pressure gauges.
17
16 Pressure Calibration
Pressure Comparators
Precise pressure generation for comparing a device under test
to a master gauge.
18 Pressure Calibration 17
Bench Deadweight Testers
Deadweight testers are highly accurate, robust and flexible pressure
measurement standards capable of calibrating a wide range of instruments.
18 Pressure Calibration
Bench Pressure
Controllers and Electronic
Deadweight Testers
High performance, with powerful features for a wide range of pneumatic
pressure calibrations.
Pressure Calibration 19
A pressure calibration system
needs to accurately measure
pressure and may also need to
measure pressure transmitters.
20 Pressure Calibration
Temperature
Calibration
21
Handheld Temperature
Calibrators
Suitable for calibrating temperature transmitters, panel meters and other
devices that connect to temperature sensors.
Field metrology wells are light weight, small and quick to reach
temperature set points yet also stable, uniform and precise. This
industrial product line is perfect for transmitter loop, comparison
calibration, or a simple check of a thermocouple sensor. There is
no need to carry additional tools into the field as the “process”
option offers a built-in readout for resistance, voltage and mA
measurement, 24V loop power and on-board documentation.
9142 Field Metrology Well 9143 Field Metrology Well 9144 Field Metrology Well
Maximising portability, speed, Maximising portability, speed, and Precision calibration with fast
and functionality for the industrial functionality for the industrial temperature ramp-up rates for the
process environment. process environment. industrial process environment.
• –25°C to 150°C temperature • 33°C to 350°C temperature range • 50°C to 660°C temperature range
range • Display accuracy of ± 0.2°C over • Heat to 660°C in 15 minutes
• Display accuracy of ± 0.2°C over full range • Display accuracy from
full range • Built-in two-channel readout ± 0.35°C at 420°C to
• Built-in two-channel readout for PRT, RTD, thermocouple, ± 0.5°C at ± 660°C
for PRT, RTD, thermocouple, 4-20 mA current • Optional built-in reference
4-20 mA current • Optional built-in reference thermometer readout
• Optional built-in reference thermometer readout • Accredited calibration
thermometer readout • Accredited calibration au.flukecal.com/9144
• Accredited calibration au.flukecal.com/9143
au.flukecal.com/9142
Temperature Calibration 23
Infrared Temperature Sources
Bench and field precision infrared calibrators for accurate and reliable
calibrations of infrared thermometers.
24 Temperature Calibration
Thermometer Standards
Delivering exceptional accuracy, wide measurement range and
designed to go where you work.
Temperature Calibration 25
Precision PRTs and Thermistors
High accuracy reference temperature measurements in temperature sources
on the bench or in the field. Thermistors provide accurate and rugged
temperature measurements from 0°C to 100°C.
26 Temperature Calibration
Data
Acquisition
27
Data Acquisition System
Fluke Calibration data acquisition systems providing best-in-class
accuracy and performance.
29
Software
Designed by measurement experts, Fluke software collects and analyses
data maximising the automation of your calibration and testing processes.
LogWare
Turn a Fluke Calibration single-channel handheld or
1502A/1504 readout into a real-time data logger.
• Collects realtime data
• Calculates statistics and displays customisable graphs
• Allows user-selected start times, stop times and sample
intervals
30 Software
Fluke Seminars and
Workshops
Fluke offers a variety of tools including hands-on and online training, videos and demos to help increase
your skills. Fluke seminars and workshops cover a range of topics to help you learn the latest troubleshooting
techniques and best practices. Most of Fluke’s seminars and workshops combine instructor lead training with the
opportunity to use the tools and try the techniques presented.
PREDICTIVE MAINTENANCE
The Fluke Predictive Maintenance Workshop provides thermal imaging,
vibration testing and general analysation hands-on training that will help
learners to troubleshoot faster and avoid downtime using the latest infrared
technology and vibration technology.
ENERGY MEASUREMENT
Discover how to reduce energy consumption and increase savings by
learning where and how to quantify energy consumption, and identify
energy waste.
ProcessCalibration
Process Calibration Tools
Tools 32
31
32
Notes
32 Notes
New PCT products from Fluke
Fluke 712B and 714B Temperature
Calibrators
For the temperature calibration professional that wants a
highly accurate, easy-to-use, single function temperature
calibrator the 712B and 714B are ideal test tools. The
712B can measure and simulate (13) different RTD types
and resistance and the 714B can measure and simulate
(17) different thermocouple types and millivolts.
www.facebook.com/flukeaustralia
www.twitter.com/flukeaustralia
www.youtube.com/flukecorporation
Contact Us:
General product and sales information:
( +61 2 8850-3333
* auinfo@fluke.com
7 http://www.fluke.com.au
7 http://www.au.flukecal.com
Fluke. The Most Trusted Tools in the World.