GSM/UMTS/LTE
Version 4.3.2
APM30
1400
1400
RFC
200
PLINTH
200
FAN
Outdoor Macro Outdoor Macro SLPU
BTS3900A Ver.A BTS3900A Ver.D EPU (power)
(no Reuse*) (No Reuse for sub rack
4x4 MIMO)
BBU
PLINTH
Outdoor Macro
BTS3900A Ver.E
Outdoor Macro
(New)
BTS3900A Ver.B
(no Reuse*)
Note:
Usage of TMC for BBU is not recommended. Only if on site no space for further APM30 cabinet.
*Notes:
• Since July 2017 only the BBU3910 can be ordered.
• BBU3900 will be equipped with 2 UPEUc Cards
• BBU3910 will be equipped with 1 UPEUd card and 1 UEIU card.
• All other combinations (e.g. UPEUd in BBU3900 or a UPEUc+UPEUd mix) are not allowed.
• Also the combination BBU3910 and LBBPd1/WBBPf4 is not allowed.
• BBU5900 Only available for L700 configurations until sRAN15.1.
• BBU5900 will be equipped with 1 UPEUe card and 1 UEIU card.
Policies:
• Only BBU3900 shall be used. If no BBU3900 available also in Re-use an BBU3910 can be ordered.
• UBBPd5 and UBBPe3 are identical and can be used based on availability.
• 3G: For each 5MHz carrier one UBBPd2/WBBPf4 or each 10MHz carrier one UBBPe4 processing
board to be used.
• LTE: For each LTE frequency layer one BB processing board to be used except 2x2 MIMO UL2100.
• LTE: Additional or different BB processing board (marked in grey) in case of 4 sector config.
• LTE: L800 only sites one LBBPd1 has to be used. For all other Config’s LBBPd1 is forbidden.
Notes:
“2G+LTE” in one BBU chassis and “3G only” in one BBU chassis are the only approved BB configurations for consolidation.
* These Units have to be used until EOM which will be Q4-2019.
Notes:
- Based on capacity different Board types for some frequencies are possible.
- In case of UL2100, max 2 U2100 carriers can handle by one UBBPe4
R-Reuse Only
5S- 5000er Series
Freq: 900 or 1800M Dim: Freq: 900 or 1800M Dim: Freq: 900 or 1800M Dim: Freq: 900 or 1800M Dim:
400x300x100mm 400x300x100mm
TX Ch (1800M): 2x40W 9Ux14HPx308.5m 9Ux14HPx308.5m
TX Channel: 2x80W m (with panel) TX Channel: 2x60W TX Channel: 2x80W
m (with panel) Weight: ≤14kg Weight: ≤15kg
TX Ch (900M): 2x45W Carrier Capacity: 8 Weight: ≤12kg Carrier Capacity: 8 Carrier Capacity: 8
Weight: ≤12kg
Carrier Capacity: 2
R-Reuse Only
Notes:
• In case of UL2100 only WRFUe is approved.
R-Reuse Only
5S- 5000er Series
EOM: 2018Q4
* 9U = 9*44.45 = 400.05mm; “U” is used to indicate the industry 19’’ rack’s high
14HP =14*5.08=71.12mm; ”HP” is used to indicate the industry 19’’ rack’s width
** LRFU is already EoM (End of Marketing) therefore LRFUe has to be orderd.
*** High-power RFU: Only applicable to Ver. D and Ver. E cabinets.
Notes:
• In case of 4x4 MIMO 2xMRFUd (1800MHz) and 2xRR3959 (1800MHz) is approved.
• 2xLRFUe (2600MHz) only usable in case of no GSM MFUs are installed. Otherwise for L2600 RRU5304 needed.
R-Reuse Only
Freq: 800M Dim: Freq: 1800M Dim: Freq: 2600M Dim: Freq: 2600M Dim:
400x240x160mm 400x300x100mm 400x285x170mm 400x300x100mm
TX Channel: 2x40W TX Channel: 2x60W TX Channel: 2x40W TX Channel: 2x40W
Weight: ≤15kg Weight: ≤14kg Weight: ≤19kg Weight: ≤14kg
Carrier Capacity: 2 Carrier Capacity: 2 Carrier Capacity: 2 Carrier Capacity: 2
EOM: 2019Q4
Freq: 800M / 2600M Dim: Freq: 800M Dim: Freq: 700M / 2100M Dim: Freq: 1800M Dim:
400x300x100mm 400x300x100mm 400x300x100mm 400x300x100mm
TX Channel: 2x40W TX Channel: 2x40W TX Channel: 2x60W TX Channel: 2x80W
Weight: ≤14kg Weight: ≤15kg Weight: ≤14kg Weight: ≤15kg
Carrier Capacity: 2 Carrier Capacity: 3 Carrier Capacity: 2 Carrier Capacity: 2
RRU5508:
UMTS2100 LTE2100 LTE1800
S222 with 40W 2x40W 2X40W
S444 with 20W 2x40W 2X40W
S444 with 40W - 2X40W
S444 with 40W 2x40W -
RRU5502:
UMTS2100 LTE2100 LTE1800
Notes:
S444 with 40W 4x40W - • Dual-Band RRU (RRU55xx): Only applicable to Ver. E
S222 with 40W 2x40W 2X40W cabinets.
S444 with 40W 4x20W 4X20W
- 4x40W 4x40W
• For all new Radio site planning activities (NetSite status value </=30 or NetSite status value >30
to <53 [draft planning status]) or re-planning site by site after co-ordination between regional
Radio Planer Telefonica and GU-Partner only radio modules of RRU 5000 series marked with
(5s) in privies slides are approved. All other existing Radio modules marked with (R) in privies
slides can be only be used as Re-Use installation.
• In case of Macro Installation this means that these RRU 5000 series units can be realized close
to the BS cabinet (APM30) as a called Makro solution (w/o RFC Cabinet and total cable Loss <2
dB) or close to antenna as a called “main-remote” (RRU and total cable Loss <1 dB) solution.
Makro Site Solution with Makro HW Makro Site Solution with new RRU 5s HW
RRU 4G
RRU 4G
RRU 4G
RRU 2G
RRU 2G
RRU 2G
RFC6 RFC6 RFC6 RFC6 APM30
3G 2G/4G 2G/4G 3G 2G/4G
Note: The guidelines from the Telefonica Planning Handbook must be considered for both Site Solution (Makro and RRU HW)
Notes:
* See slide 46 regarding Items to be swapped out during consoldiation
Notes:
*GSM 4 Sector sites will be only supported by the MRFUd Radio Units and with maximal 4 TRX per Sector.
** Exception for SUR Project Phase1&2, which allows only to install 3xWRFU modules with reduced output power.
Until Q1-2019 only Remote (RRU) 5series units shall be planed, because all Macro Module will run out of marketing.
Notes:
* Exception for SUR Project phase 1&2, which allows only to install 3xWRFU modules with reduced output power.
** UMTS 6 carrier sites will not be approved by Re-use Radio Units (WRFU/RRU3804).
Until Q1-2019 only Remote (RRU) 5series units shall be planed, because all Macro Module will run out of marketing.
Example Target
Usable modules with Usable modules with
Technology Configuration
Cabinet Versions A/B/D/E Cabinet Version D/E
(S111, 2x2 MIMO/4x4 MIMO)
10 MHz, 2x40W, Macro - 3 x LRFUe 800MHz
LTE800 10 MHz, 2x40W, Remote 3 x RRU3268 800MHz 3 x RRU3268 800MHz
10 MHz, 2x60W, Remote - 3 x RRU5309 800MHz
10/15 MHz, 2x80W, Macro - 3 x MRFUd 1800MHz
10/15 MHz, 2x40W, Remote - 3 x RRU5508 1800+2100MHz
LTE1800 10/15 MHz, 2x60W, Remote - 3 x RRU3959 1800MHz
10/15 MHz, 2x80W, Remote - 3 x RRU5905 1800MHz
10/15 MHz, 4x40W, Remote - 6 x RRU3959 1800MHz
10/15 MHz, 4x40W, Remote - 3 x RRU5901 1800MHz
20 MHz, 2x40W, Macro 3 x LRFU 2600MHz 3 x LRFU 2600MHz
20 MHz, 2x60W, Macro - 3 x LRFUe 2600MHz
LTE2600
20 MHz, 2x40W, Remote 3 x RRU3268 2600MHz 3 x RRU3268 2600MHz
20/30 MHz, 4x40W, Remote 6 x RRU3268 2600MHz 6 x RRU3268 2600MHz
20/30 MHz, 4x40W, Remote - 3 x RRU5304 2600MHz
10 MHz, 2x40W, Macro
- 3 x WRFUe 2600MHz
10 MHz, 4x20W, Macro
10 MHz, 2x40W, Remote 6 x RRU3826 2100MHz
LTE2100 -
10 MHz, 4x20W, Remote 3x RRU 5909 2100MHz
3x RRU 5909 2100MHz
10 MHz, 2x40W, Remote -
3 x RRU5508 1800+2100MHz
RF Module Comment Working BW [MHz] Instantaneous BW [MHz] Number of Transmit Usage Approved
and Receive Mode
Channels
LRRU3220 (2x40W; for LTE800) 2 sub-band models: A: 15 MHz 2T2R Existing today LO
A: Lower 15 MHz B: 20 MHz
B: Upper 20 MHz
LRRU3201 (2x40W; for LTE2600) 5 sub-band models: 30 MHz 2T2R Existing today LO
A: 2620 to 2665 MHz (DL): 45 MHz
B: 2645 to 2690 MHz (DL) : 45 MHz
C: 2620 to 2640 MHz (DL) : 20 MHz
D: 2630 to 2680 MHz (DL) : 50 MHz
E: 2670 to 2690 MHz (DL) : 20 MHz
Blade RRU3268 (2x40W; for LTE800) Full Band (30 MHz) 20 MHz 2T2R Consolidation LO
Installation
Blade RRU3268 (2x40W; for LTE2600) Full Band (70 MHz) 50 MHz 2T2R Consolidation LO
Installation
Blade RRU3959 (2x60W; for L1800) Full Band (75 MHz) 45 MHz 2T2R Consolidation LO, GL
(2x60W; for GL1800) Installation
Blade RRU3959 (2x60W; for G900) Full Band (E-GSM: 35 MHz) 35 MHz 2T2R Installation Starting GO
August 2016
LRFUe (2x60W; for LTE800) Full Band (30 MHz) 20 MHz 2T2R Consolidation LO
Installation
Blade RRU5309 (2x60W; for LTE800) Full Band (30 MHz) 20 MHz 2T2R Installation Starting LO
Q1-2019
MRFUd (2x80W; for LTE1800) Full Band (75 MHz) LTE: 40 MHz 2T2R Consolidation LO, GL
GSM/GSM+LTE: 35 MHz Installation
Blade RRU5905 (2x80W; for G900) Full Band (E-GSM: 35 MHz) LTE: 45 MHz 2T2R Installation Starting GO, LO, GL
(2x80W; for G1800) Full Band (75 MHz) GSM/GSM+LTE: 35 MHz Q1-2019
(2x80W; for L1800) Full Band (75 MHz)
(2x80W; for GL1800) Full Band (75 MHz)
LRFUe (2x60W; for LTE2600) Full Band (70 MHz) 60 MHz 2T2R Installation Starting LO
August 2016
RRU3804 (1x60W; for U2100) Full Band (60 MHz) 20 MHz 1T2R Existing today UO
WRFU (1x80W; for U2100) Full Band (60 MHz) 20 MHz 1T2R Existing today UO
Consolidation
WRFUe (2x80W; for U2100) Full Band (60 MHz) 60 MHz 2T2R UO
Installation
Consolidation
Blade RRU3826 (1x80W; for U2100) Full Band (60 MHz) 40 MHz 1T2R UO
Installation
Consolidation
MRFUd (2x80W; for 900) Full Band (E-GSM: 35 MHz) 35 MHz 2T2R GO
Installation
Installation Starting
Blade RRU5909 (2x60W; for U2100) Full Band (60 MHz) 60 MHz 2T2R UO
Q1-2019
Installation Starting
Blade RRU5901 (4x40W; for L1800) Full Band (75 MHz) 45 MHz 4T4R LO
Q1-2019
Installation Starting
Blade RRU5304 (4x40W; for L2600) Full Band (60 MHz) 60 MHz 4T4R LO
Q1-2019
UL2100 adaptations:
- 1x sync cable
- 4x CPRI cables
- 4x RRU5909
Note: UL2100 for 2 UMTS Carrier with max. 2x30W and 4 Carrier with max 4x15W
/e3
BBPd5/e3 in Slot3
Note: RRU3826 is approved only for re-use and 4 UMTS Carrier sites with max. 4x20W
1 1
RRU Macro Broadband Monoband Other
Nr Config L800 (10) L1800 (20) L2100 (20) L2600 (20) L2600 (+10) Baseband FOA
Extension Sites Extension Sites Option Option Possibility
4x4 4x4 2xRRU3959 2xMRFUd RRU5502 RRU5901 2xMRFUd
1 N417 4x4 YES
(26W/40W) (13W/20W) 2xRRU3268 RRU5304 RRU5304 RRU5304 2xLRFUe
RRU3268 LRFUe RRU5509 RRU5309 RRU3268
4x4 4x4
2 N418 2x2 4x4 4x4MIMO ; L2600 30MHz: *till Q42019 2xRRU3959 2xMRFUd RRU5502 RRU5901 RRU5901 YES
(26W/40W) (13W/20W)
2xRRU3268 RRU5304 RRU5304 RRU5304 RRU5304
2xRRU3959 2xMRFUd RRU5901 2xRRU3959
3 N411 4x4 2x2 RRU5502 NO
RRU5909 WRFUe RRU5909 2xRRU3826
RRU3268 LRFUe RRU5309
RRU5509 RRU3268
4 N407 2x2 4x4 2x2 2xRRU3959 2xMRFUd RRU5901 YES
RRU5502 RRU5502
RRU5909 WRFUe RRU5909
2xRRU3959 2xMRFUd RRU5901 2xMRFUd
4x4 4x4 RRU5502
5 N412 4x4 2x2 RRU5909 WRFUe RRU5909 WRFUe NO
(26W/40W) (13W/20W) RRU5304
2xRRU3268 RRU5304 RRU5304 2xLRFUe
RRU3268 LRFUe RRU5309
RRU5509 RRU3268
4x4 4x4 2xRRU3959 2xMRFUd RRU5901
6 N409 2x2 4x4 2x2 RRU5502 RRU5502 YES
(26W/40W) (13W/20W) RRU5909 WRFUe RRU5909
RRU5304 RRU5304
2xRRU3268 RRU5304 RRU5304
7 4x4 2xRRU3959 2xMRFUd RRU5502 RRU5901 - No
RRU3268 LRFUe RRU5509 RRU5309 RRU3268
8 2x2 4x4 No
2xRRU3959 2xMRFUd RRU5502 RRU5901 RRU5502
4x4 4x4
9 2xRRU3268 2xLRFUe RRU5304 RRU5304 - NO
(26W/40W) (13W/20W)
4x4 4x4 RRU3268 LRFUe RRU5509 RRU5309 RRU3268
10 2x2 NO
(26W/40W) (13W/20W) 2xRRU3268 2xLRFUe RRU5304 RRU5304 RRU5304
1
Rollout with legacy MFU/RRU is recommanded, if possible (see EOM Date)
2
In case of 2xRRU more than 6+3 CPRI Ports are needed
1) 4x4MIMO Macro solutions, the L2600 Radio Units have to be planed as Remote Installation (RRU),
because of no free slots in RFC-6 cabinet.
2) No Mix of 2x2MIMO and 4x4MIMO for 1800MHZ and 2600MHz approved.
3) 4x4MIMO 4 Sector solutions only approved with new series 5000 RRUs.
4) 4x4MIMO no Mix of old (3900 series) and new (5900 series) RRUs are allowed.
5) 4x4MIMO no Mix of RRU and RFU modules. Only exception see point 4.
6) UL2100 + 4x4 MIMO, no 2xRRU Installation for UL2100 allowed. Only RRU5909 supported in this case,
because of to less CIPRI Ports on dedicated UBBPd5/e3.
L1800 15/20MHz: recommend to have 6.144Gbps SFP on all ports (RRU and BBP).
Note: Only possible for Configuration N417 ! All other L2600 4x4MIMO Confi-
guration have been build with RRUs (mainly RRU5304 or 2xRRU3268 if needed).
L2600 30MHz: Parallel Mode recommend to have 4.25Gbps SFP with turn Normal
CPRI compression on all ports (RRU and BBP).
36 Restricted – Beschränkter Zugriff
DISCOVER, DISRUPT, DELIVER
Huawei 4x4 MIMO – 2x2T2R RRU Distributed Solution
HF and CPRI Cabling Overview for RRU3959
For L1800 distributed sites, the CPRI connectivity is done with optical cables in
cascade mode only.
L1800 15/20MHz: recommend to have 6.144Gbps SFP on all ports (RRU and BBP).
For L2600 distributed sites, the CPRI connectivity is done with optical cables in
parallel mode only.
L2600 30MHz: Parallel Mode recommend to have 4.25Gbps SFP with turn Normal
CPRI compression on all ports (RRU and BBP).
L1800 15/20MHz (RRU5901): RRU Package includes 6.144Gbps SFP for RRU and BBP.
L2600 30MHz (RRU5304): RRU Package includes 9.8Gbps SFP for RRU and BBP.
Notes:
* “Modernization” shall only be done for indoor BTS3900(A) cabinets (if required)
** 4x4MIMO and RRU5508 Configuration approved for BTS3900(A) Ver. E only.
1BBU
APM30H Ver.B * (Max 300 W)
6RFU ( in 1xRFC ) 6RRU 6RFU + 3RRU
APM30H Ver.D ** 1BBU 12RFU( in 2xRFC ) 12-15RRU *** 6RFU + 9RRU ****
2 (1+1)
PSU Number 3 (2+1)
(default)
Note:
One APM30H Ver.D supports maximum 12RFU or 15RRU or 6RFU+9RRU
2 (1+1)
PSU Number 3 (2+1) 3 (2+1)
(default)
Note:
One APM30H Ver.E supports maximum 12RFU or 21RRU or 12RFU+9RRU
The following rules shall apply for the required number and type of UPEU
boards in the BBU chassis:
BBU3900 BBU3910
BBU UPEUa * UPEUc ** UPEUd
BBP Board Configuration related (300 W) (360 W for 1 UPEUc, (640 W for 1
Mode 650 W for 2 UPEUc) UPEUd)
GO 1 1 1
WBBPf4 ≤ 2 1 1 N/A
UO, GU
WBBPf4 > 2 - *** 2 N/A
UBBPd5/e3/e4 ≤ 2 1 1 1
LO, GL
UBBPd5/e3/e4 > 2 - *** 2 1
Notes:
WBBPf4 and LBBPd1 board will not supported by BBU3910
* Reuse only
** If UPEUc is used in BBU where the BTS3900A Ver.A/B is re-used, the FMU software must be updated
*** UPEUa is not applicable, and must be replaced by UPEUc
Notes:
1) For Macro sites only APM30 Cabinets will be supported.
2) RRU RRU5309/RRU3268/RRU3220 and RRU3959/5905 cause to the same H/W Template.
3) UBBPd3 or UBBPd5 can be 1:1 replaced by UBBPe3. Means also for NetSite Capacity fields.
4) In case of alternative Cabinets like SSC only LTE Remote solutions are supported within the
given Templates.
5) All Virtual Marco solutions for GSM are not approved !
6) 4x4MIMO Macro solutions, the L2600 Radio Units have to be planed as Remote Installation
(RRU), because of no free slots in RFC-6 cabinet.
7) 4x4MIMO 4 Sector solutions only approved with new 5000 series RRUs.
8) 4x4MIMO no Mix of old (3900 series) and new (5900 series) RRUs are allowed.
9) 4x4MIMO no Mix of RRU and RFU modules. Only exception see point 6.
10) UL2100 + 4x4 MIMO, no 2xRRU Installation for UL2100 allowed. Only RRU5909 supported
in this case, because of to less CIPRI Ports on dedicated UBBPd5/e3.
11) UL2100 Mixed Configuration no 2xRRU Installation allowed. Only RRU5909.
12) 4 Sector Configurations N209, N308, N309, N212 only possible if G900 will configured with
Remote Radio Modules (RRU3959 or RRU5905)
Each Combination of Macro and RRU installation within one site needs an own Template.
The left table shows the supported variations.
However it is recommended to plan only pure RRU and Macro sites.
For GL (RF-Sharing) solution only such pure RRU and Macro sites are approved !
From the currently installed Huawei modules, during consolidation the following
modules shall not be re-used:
GSM:
- GTMUa
UMTS:
- WBBPb2
- WBBPb4
- WMPT
- UMPTa1 only at UL2100 sites
- UPEUa
LTE:
- LBBPc
- LMPT
- LBBPd1 at all sites which are not L800 only sites and no BBU3910 is installed
Policies:
• Only BBU5900. If no BBU3900 available also in Re-use an BBU3910 can be ordered.
• 2G BBP only UBBPd2 or UBBPd3 allowed. Need to be reused from on site existing UMTS
or L800 Configuration. If both available UBBPd3 shall be taken.
• GL1800 shall be configured on in case 2G and LTE MPT is located in the same BBU.
• Solution with 2xBBUs will only be used in case:
• 4 Sector sites
• Tx IP solution for GSM not available.
• If UBBPd2 or UBBPd3 can not be re-used (potentially in OESTE, SUR area’s)
Radio Access:
http://teamsite.de.pri.o2.com/teams/Mobile_Access/Freigegebene%20Dokumente/02%20D
esign%20Guidelines/01%20Hardware%20Design/Huawei%20HW%20Overview%20for%20Planne
rs_2019-07-04_V4.3.2.pptx
Region West:
http://teamsite.de.pri.o2.com/teams/RAN_Region_West/Freigegebene%20Dokumente/Dok
umentation/Huawei%20HW%20Overview%20for%20Planners_2019-07-04_V4.3.2.pptx
Region South:
http://share-ex.de.o2.com/projects/RAN_S-
1015/Shared%20Documents/Funknetzplanung/02_Konsolidierung/Unterlagen%20f%C3%BCr%
20Planung%20DKP/Huawei%20HW%20Overview%20for%20Planners_2019-07-04_V4.3.2.pptx
DAX:
https://dax.portal.telefonica.de/wiki/GUIDELINES-for-INSTALLATION-%26-COMMISSIONING
APM30H Advanced Power Module Huawei SSC cabinet with Heat Exchanger (versions B and D)
TMC11H TransMission Cabinet with Heat exchanger TransMission Cabinet (outdoor capable) with 11 Height units
RFC-6 Radio Frequency Cabinet Radio Cabinet (outdoor cable) for up to 6 Radio Frequency units
BBU BaseBand processing unit Baseband Processing unit – chassis for BB modules
MPT Main Processing and Transmission unit Main Processing and Transmission unit installed in BBU chassis
GTMU GSM Main Processing and Transmission unit GSM Main Processing and Transmission unit installed in BBU chassis
UMPT Universal Main Processing and Transmission unit Universal (for 3G and LTE) Main Processing and Transmission unit installed in BBU chassis
WBBPx WCDMA BaseBand Processing unit BaseBand processing for WCDMA
LBBPx LTE BaseBand Processing unit BaseBand processing for LTE
UBBPx Universal BaseBand Processing unit BaseBand processing for WCDMA and LTE
BBU BBU3900
The following table summarises the power consumption of the different BBU
submodules:
UFANA 20
UFANC 30
GTMU 30
UMPTa1 /b1 55
WMPT 25
WBBPb4 30
WBBPf4 85
LBBPd1 85
LBBPc 82
UMPTb1 40
UMPTe2 55
UBBPd2/d3/d5 85
UBBPe3/e4/e5 85
Sector (Azimuth) 1 2 3 4 5 6
L800 1 2 3 4 5 6
L2600 7 8 9 10 11 12
L1800 13 14 15 16 17 18
L700 19 20 21 22 23 24
L2100 25 26 27 28 29 30
Example:
L800 IDs: 1 2 3 - - -
L2600 IDs: 7 8 9 - - -
L1800 IDs: 13 14 15 - - -
L700 IDs 19 20 21 - - -
L700 L2100 L2100 IDs 25 26 27 - - -
(K) (Y)
15 kg (without housing)
Weight(kg) 14 kg
17 kg (with housing)
480 mm x 270 mm x 140 mm (without the housing)
Dimensions (H x W x D) 400 mm x 300 mm x 100 mm
485 mm x 285 mm x 170 mm (with the housing)
Weight(kg) 16.5 kg 19 kg 23 kg 14 kg
2G Comissioning rules
1) All the RFU boards are configured from left to right. Starting for G900 in slot 0 and G1800 in slot3 and going from there on. If two RFC cabinets are needed, the second cabinet also starts in the same slot positions.
2) All the RRU's are configured starting on slot 60 and advancing one slot per RRU. Example: RRU1 is -0-60-0, RRU2 is 0-61-0, etc. Exception if GL1800 starting on slot 72.
3) The GTMU CPRI port connection follows the left to right rule. The comissioning order is - port 0, port 1, port 2 and port 3 and so on.
3G Comissioning rules
1) All the RFU boards are configured from left to right. Starting in slot 0 and going from there on. If two RFC cabinets are needed, the second cabinet also starts from slot 0. This rule has an exception for sites with 3 or less sectors.
2) All the RRU's are configured starting on slot 80 and advancing one slot per RRU. Example: RRU1 is -0-80-0, RRU2 is 0-81-0, etc.
3) The WBBP/UBBP slot order for comissiong is - Slot 3, Slot 2, Slot 1, Slot 0, Slot 4 and Slot 5. Examples present in the following sheet.
4) CPRI port connection follows the left to right rule. The comissioning order is - port 0, port 1, port 2 and port 3 and so on.
4G Comissioning rules
1) All LTE RFU boards are configured from left to right. Starting in slot 3 and going from there on to slot 5. For 4 sector sites the 4th RFU is lacated in slot 2. If two RFC cabinets are needed, the second cabinet also starts from slot 3. Examples on LTE
2) All the RRU's are configured starting on slot 60 and advancing one slot per RRU. LTE800 RRU's from 60 to 65, LTE1800 RRU's 72 to 77 and LTE2600 RRU's 66 to 71.
3) The LBBP/UBBP comissioning slot for LTE800 is slot 3, for LTE1800 slot 2 and for LTE2600 slot 1. If more than 3 cells are needed for LTE800, an UBBP board on slot 4 is added as an extension for the rest of the cells.
4) CPRI port connection on UBBP/LBBP boards on slot 3 and 1 follows the left to right rule. The comissioning order is - port 0, port 1 and port 2. If more then 3 cells are needed on LTE800, the CPRI port connection on the BB board on slot 4 follows
the left to right rule. Example - Cell 4 LTE 800 -> CPRI port 0 and UBBP/LBBP slot 4; Cell 4 LTE 18000 -> CPRI port 1 and UBBP/LBBP slot 4; Cell 4 LTE 26000 -> CPRI port 2 and UBBP/LBBP slot 4.