Have a Yellow colored round lead free cable jacket available in both OFNR and
OFNP constructions.
Shall contain a Rip Cord applied under the cable jacket for easy cable jacket
removal
Shall contain a lightweight Central Strength member located in the middle of the
fiber bundles.
Shall contain both color-coded buffered fibers as well as color-coded buffer
tubes.
Cables shall have length markings in 2 ft. increments
Fiber will be available in strand counts of 2, 4, 6, 8, 12, 16, 24, 36, 48, 72, 96 and
144.
Shall meet these minimum performance parameters:
Minimum Performance Parameters for Qualified Cables
Maximum Attenuation
Zero dispersion Index of Refraction
Fiber Cable Type (dB/km)
1310 nm 1550 nm Wavelength (nm) Slope (nm²-km) 1310 nm 1550 nm
Singlemode Indoor 0.50 0.50 1300-1324 <0.093 1.467 1.468
Physical Characteristics
Cladding Coating
Mode and Fiber Core Size Buffer Size
Size Size
Type (Microns) (Microns)
(Microns) (Microns)
Singlemode 8.3 ± 1 125 ± 1.0 245 ± 10 900 ± 50