CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M N1 A2 B1 2 L SINGLE DETAILS, SEE DOCUMENT
1 3 N
PHASE
SUPPLY RWS100
A1 B2
MOTOR E
CS CR SWITCHING TRANSFORMER TAPPING OPTIONS
MODULE
FS1
Tap Nominal 50/60Hz

SK16
LIVE

B+
A+
FUSE FS1

A-

B-
VOLTAGE 50HZ/60HZ
CR2
SEE NOTE LOW 115 500mA

SK17
NEATRAL

HIGH 230 250mA


CS2
SEE NOTE Z X W U FUSE FS1 TO BE ANTI SURGE
CAPACITOR START/RUN (CS/CS2 AND
CR/CR2) COMBINATIONS & VALUES
SK2
0VAC 1 VARY WITH SUPPLY VOLTAGE &
PS1 ACTUATOR SIZE.
120VAC 4
REFER TO SHEET 2 FOR NOTES
0VDC
3 4 & OPTION PCB'S IF FITTED
24VDC
24VDC 6
CSN1
_ 5 NOMINAL SUPPLY

+
CS1 CRN2 1 2 3 4 (OUTPUT)

SK 25 SK14
0VDC 1
START INTERNAL SUPPLY
MODULE 24VDC FOR CPT PCB
2
SK13

26 WAY

SK3 SK13 SK14


6 1 42
MONITOR RELAY
5 3 43
TORQUE 4 2 44
3
2
SK7
SENSOR 1 1 6
SK8 MAKE AT FULLY SHUT S1 8 7
POSITION 10 WAY 2 8
SENSOR MAKE AT FULLY OPEN S2 7 9
SK9 BREAK AT FULLY SHUT
3 10
BATTERY - 4
S3 6 11
4 12
+
1 BREAK AT FULLY OPEN S4 5 13
FS2 (IF FITTED) 100mA SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY
STOP
ESD 12 25
CLOSE

OPEN
LOCAL
OPEN INTERLOCK 13 37
REMOTE

CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B

Iss Date Chkd Revision Details IQ SINGLE PHASE + CTT + CPT


1 270813 PJW FIRST ISSUE www. .com
2 041113 PMJ Fuse requirements for low and high
voltage included. Fuse comment ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: JC1 Circuit Diagram Number Issue Sheet
updated.
BATH, BA1 3JQ ROCHESTER Date : 270813 No
3 180614 MR Note 1 added to sheet 2 ENGLAND NY 14624, USA
Base WD: 122B0000
Job No : - -
122B0000 3
1
of 2
Tel:01225-733200 Tel:585-247-2304 MI No : - - B1 C1 B2 C2
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A SK3
-VE +VE
1 23 A
2 22
3
4
5
CPT

NOT USED 4 FOR DETAILS OF CPT FUNCTIONS


REFER TO ROTORK PUBLICATION PUB002-041
6
7
8

SK6
1 0V
2 24V SUPPLY FROM SK14 ON POWER PCB
SK8
1
2

SLOT B
SK2
SLOT B SK3
-VE +VE
1 29 A
2 28
3
4
5
CTT

NOT USED 4 FOR DETAILS OF CTT FUNCTIONS


REFER TO ROTORK PUBLICATION PUB002-041
6
7
8

SK6
1 0V
2 24V SUPPLY FROM SK8 ON CPT PCB
SK8
1
2

NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -“S” contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. “unavailable”). It can be configured to exclude local/remote selection.
-For DC and AC control, connect –ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: “on” ≥16Vdc / “off” ≤8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: “on” ≥60Vac / “off” ≤40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote “S” contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
122B0000 3 2
See Sheet 1 for all Revision details/information of 2