INSTRUMENT AIR RECEIVER SIZING

Vessel Item Number:


Service:
Calculation Case:

Flowrate for sizing Select Unit of Flow

REFERENCE
Design Flowrate ( C ) = kg / hr
0.00 Nm³ / hr

Design Basis

Supply time ( t ) = minutes


Air Supply Temperature = o
C
Initial Receiver Pressure ( P1) = bar g
Final Receiver Pressure ( P2) = bar g
Pressure at Normal Conditions ( p ) = 1.01325 bar a

NOTE: Formula for sizing taken from FW Italiana Offsites Manual for Instrument and Plant Air

Receiver Volume Required( V ) = t x C x p m³ Based on air temp = 0 oC


60 x (P1 - P2)
= #DIV/0! m³

Corrected Receiver Volume Required = #DIV/0! m³ Based on air supply temperature = .0 °C

Number of Receivers =

Volume of each Receiver = m³

Calculated Dimensions of each Receiver (based on L/D ratio of ) User Input Size if required

Receiver Length/Diameter Ratio Diameter mm


(Note: L/D typically between 3 & 5)
tan - tan mm
Diameter #VALUE! mm
Actual Volume (cylinder) 0.0 m³
tan - tan #VALUE! mm
Actual Volume (incl. ends) 0.0 m³
Volume of Receiver (cylindrical section only) #VALUE! m³
Actual L / D #DIV/0!
Volume of Receiver (incl. 2:1 elliptical ends) #VALUE! m³
Actual Supply Time (Cylinder) #VALUE! mins

Actual Supply Time (Incl. Ends)) #VALUE! mins

Note (1) :

Note (2) :

Note (3) :

Version 1 2 Rev Date: Nov-03 Printed on: 1/27/2020 19:10


Filename & path: 'file:///conversion/tmp/scratch/457162134.xls'#$Calculation
FOSTER WHEELER ENERGY LIMITED VESSEL PROCESS SPECIFICATION

CUSTOMERS NAME: PROJECT No:


LOCATION: 0 UNIT No:
SERVICE: 0 ITEM No: No. REQD:
DOCUMENT CAT.-CLASS 1
REV DOCUMENT No
DATE SHEET 1 OF
ORIG. BY DOCUMENT SEQUENCE No.
APP. BY

N2

N4 Wet Air N5

N2

Dry Air

M1

N6

N1 N7A

N7
B

N3

?????? mm

Instructions: (Note that these will not appear on your print-out).


1. Select air out nozzle N2 as required. Delete unwanted nozzle N2.
2. Delete text "Dry air" and text "Wet air".
3. Delete any other nozzles not required.
4. Renumber nozzles as necessary.
5. Enter vessel dimensions in mm.

Note that the sketch can be copied into Zyqad.

NOTE 1. LLL TO BE AT LEAST 200mm ABOVE BTM TAN LINE.

NOTE 2. SEE SEPARATE DATA SHEET FOR NOZZLE CHART, DESIGN DATA ETC.

ITEM No. 0 SHEET 1 OF


FWEL.2068/1 Rev.6 BASE : Vessel Datasheet.xls
FOSTER WHEELER ENERGY LIMITED VESSEL PROCESS SPECIFICATION

CUSTOMERS NAME: PROJECT No:


LOCATION: 0 UNIT No:
SERVICE: 0 ITEM No: No. REQD:
DOCUMENT CAT.-CLASS 1
REV DOCUMENT No
DATE SHEET 1 OF
ORIG. BY DOCUMENT SEQUENCE No.
APP. BY

N2

N4 Wet Air N5

N2

Dry Air

M1

N6

N1 N7A

N7
B

N3

?????? mm

Instructions: (Note that these will not appear on your print-out).


1. Select air out nozzle N2 as required. Delete unwanted nozzle N2.
2. Delete text "Dry air" and text "Wet air".
3. Delete any other nozzles not required.
4. Renumber nozzles as necessary.
5. Enter vessel dimensions in mm.

Note that the sketch can be copied into Zyqad.

NOTE 1. LLL TO BE AT LEAST 200mm ABOVE BTM TAN LINE.

NOTE 2. SEE SEPARATE DATA SHEET FOR NOZZLE CHART, DESIGN DATA ETC.

ITEM No. 0 SHEET 1 OF


FWEL.2068/1 Rev.6 BASE : Vessel Datasheet.xls
FOSTER WHEELER ENERGY LIMITED VESSEL PROCESS SPECIFICATION

CUSTOMERS NAME: 0 PROJECT No: Err:504


LOCATION: 0 UNIT No: Err:504
SERVICE: 0 ITEM No: Err:504 No. REQD: Err:504
DOCUMENT CAT.-CLASS 1
REV Err:504 Err:504 Err:504 Err:504 DOCUMENT No. Err:504
DATE Err:504 Err:504 Err:504 Err:504 SHEET 2 OF Err:504
ORIG. BY Err:504 Err:504 Err:504 Err:504 DOCUMENT SEQUENCE No. Err:504
APP. BY Err:504 Err:504 Err:504 Err:504
NOZZLE CHART
CONN SIZE SERVICE REMARKS No. Design Pressure(1Top/Bottom: / barg
No. mm REQD. Design Temp. Top/Bottom: / °C
Operating PressurTop/Bottom: / barg
Operating Temp. Top/Bottom: / °C
Vac. design condition barg @ °C
Steamout Conditions:(2) °C @ barg
Short term maximum temperature °C for
hrs Coincident pressure barg

Minimum temperatur °C @ barg

Pressure/Temperature Cycling
Stress Relieved: (Process Reaso
Insulation: (4)
Fireproofing:

PED Fluid Type/ State: /

MATERIALS
Shell Corr. Allowance mm
Shell Lining/Cladding Thickness mm
Boot: Corr. Allowance mm
Boot Lining: Thickness mm
Internals: Corr. Allowance mm

Others:

GENERAL NOTES: OPERATING TEMPERATURE PROFILE (columns only)


(1) Design pressure excludes static head of liquid- Vessel Group to Tray No. °C
calculate. Maximum operating liquid m
Operating liquid SG
(2) Steam out details by Vessel Group.
(3) Number & size of instrument connections to be confirmed by InstrumentTANK VENTING DATA
(4) Personnel protection & winterisation (if required) by Engineering. Blanketing (tanks only):
(5) Special relief requiremen Max. inbreathing ra m³/h
Max. outbreathing m³/h MW kg/kmol
Emergency relief
flow kg/h
MW kg/kmol
Relieving temperature: °C
Max. relieving pressure barg
Fluid:

ITEM No. Err:504 SHEET 2 OF ###


FWEL.2068/2 Rev.6 BASE : Vessel Datasheet.xls
This sheet should never be visible to the user.
The next expiry date is calculated
It is the definitive statement of program name, version here. It onlt becomes "alive"
number, version date, expiry date and user password. when it is transferred to the
range "ExpiryDate" by using the
These details are reference by various cell formulae and by Administration facility.
VBA code.
The expiry date is set to 15th
September.

Note that after June 15th, the


Expiry Date: 15/09/2007
expiry date is set to 15th
Revision Date: Nov-03 September Next Year.

Revision: 2.00
Name: AirReceiver

Change the Expiry Date, Revision, (and


name?) as required.

Password:
Sheet Password: wardlaw
'file:///conversion/tmp/scratch/457162134.xls'#$Formula
Expiry
Dates
ate is calculated 15-Sep-01 27-Jan-20
omes "alive" 15-Sep-02 26-Apr-20
rred to the
15-Sep-03 20
e" by using the
cility. 15-Sep-04 15-Sep-20
15-Sep-05
s set to 15th 15-Sep-06
15-Sep-07
15-Sep-08 These fields are used to generate an appropriate
ne 15th, the
15-Sep-09 expiry date for the application.
to 15th
Year. 15-Sep-10 This expiry date is copied to the rangename
15-Sep-11 "ExpiryDate" when an authorised administrator
15-Sep-12 requests it via the frmAdministration form and
VBA code.
15-Sep-13
It is not anticipated that any changes will be
15-Sep-14 needed here until 2022 !!!
15-Sep-15
15-Sep-16
15-Sep-17
15-Sep-18
15-Sep-19
15-Sep-20
15-Sep-21
15-Sep-22
15-Sep-23
ppropriate

name
nistrator
rm and

will be

S-ar putea să vă placă și