Sunteți pe pagina 1din 10

Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.

com/white-paper/13663/en/

Introduction to Digital and Analog Co-simulation Between NI LabVIEW and NI Multisim


Publish Date: фев 21, 2013

Overview
The following document illustrates how to cosimulate analog and digital data between LabVIEW and Multisim software. Learn
how to use LabVIEW to vary the voltage level of a DC power supply in series with an RLC circuit in Multisim and then pass the
output voltage back to LabVIEW to be displayed on a graph.

Table of Contents
1. Introduction
2. Required Software
3. Create an Analog Circuit in Multisim
4. Create a Digital Controller in LabVIEW
5. Performing Co-simulation Between LabVIEW and Multisim
6. Conclusion
7. Related Links

1. Introduction
For the design and analysis of complete systems, including those in power and mechatronics applications, you need to
effectively design across both the analog and digital domains. Traditional platforms are unable to accurately simulate both
analog and digital together, so design errors cascade to the physical prototype and lead to an ineffective and lengthy design
approach.
With the new co-simulation capabilities between Multisim (http://ni.com/multisim/) and LabVIEW (http://ni.com/labview/), you
can design with accurate, closed-loop point-by-point simulation an entire analog and digital system. You can use LabVIEW
and Multisim to take advantage of two distinct simulation engines: Multisim simulation for the accuracy of analog and mixed-
signal circuitry and LabVIEW for the effective design and implementation of control logic. This is made possible by a unique
time-step negotiation between both simulators using the External Model Interface in LabVIEW.
2. Required Software
Before beginning co-simulation between LabVIEW and Multisim, you must install the following software in the specified order:
1. Install LabVIEW Full or Professional version 2011 or later.

2. Install the LabVIEW Control Design and Simulation Module version 2011 or later.

3. Install Multisim 12.0 or later. Select Install NI LabVIEW-Multisim Co-Simulation Plug-In for LabVIEW during the installation
of Multisim.

Стр. 1 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

4. You have now successfully installed the required development environments for LabVIEW and Multisim co-simulation.
3. Create an Analog Circuit in Multisim
1. Place a voltage-controlled power supply to allow LabVIEW to vary the DC voltage level during simulation. Right-click and
select Place component from the shortcut menu. Choose the following parameters:

Database: Master Database


Group: Sources
Family: Controlled_Voltage_Sources
Component: Voltage_Controlled_Voltage_Source

Select OK to place the component onto the schematic. You can modify the ratio of voltage output per voltage input by double-
clicking the component. For a ratio of 1 V/V, the voltage controlled voltage source in Multisim outputs 1 V for every Volt that is
passed in from LabVIEW.

2. Place the resistor, capacitor, and inductor for the circuit. Use the following parameters for ideal components:
Database: Master Database
Group: Basic
Family: CAPACITOR, INDUCTOR, RESISTOR
Component: C=50 µF, I=20 mH, R=10 Ω

With the release of Multisim 12.0, you can use nonideal resistors, capacitors, and inductors to add parasitic parameters to the
components. For nonideal components, use the following parameters:
Database: Master Database
Group: Basic
Family: NON_IDEAL_RLC
Component: NON_IDEAL_CAPACITOR, NON_IDEAL_INDUCTOR, NON_IDEAL_RESISTOR

Стр. 2 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

After placing the components, you must double-click each one to change the value of a nonideal component. At that time, you
can also modify the optional parasitics.

3. Finally, place the circuit ground. In the Select a Component dialog box, choose the following parameters:
Database: Master Database
Group: Sources
Family: Power Sources
Component: Ground

4. You are now ready to place the terminals that send and receive data to and from the LabVIEW simulation engine. These
terminals in Multisim are Hierarchical Block or Sub-Circuit (HB/SC) terminals. Right-click and select Place on
schematic»HB/SC connector from the shortcut menu or simply type <Ctrl-I>. Place one HB/SC connector above and to the
left of the schematic and another connector above and to the right of the schematic. Rotate the second connector 180 degrees
by holding Ctrl and tapping R twice. Connect the HB connectors to the circuit as seen in the image below.

Стр. 3 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

5. To configure the HB/SC connector as an input or output to LabVIEW, you must open the LabVIEW Co-simulation
Terminals window. Navigate to View»LabVIEW Co-simulation Terminals.

Notice that the HB/SC connectors placed earlier appear in this window. To configure each connector as an input or output,
select the desired choice from the Mode settings. You can then configure each connector as a voltage or current input/output
by selecting the Type. Finally, if you have placed two input or output terminals that you want to function as a differential pair,
you can select a Negative Connection. Configure IO1 as an Input and IO2 as an Output. You can immediately see the
shape of the connector changing on the schematic based on whether it's an input or an output connector.

6. Notice that the Multisim design VI preview updates with the selections that you made. This is a preview of the virtual
instrument (VI) that you later place in LabVIEW to interface with this Multisim circuit. If you want to change the input and output
terminal names of this Multisim VI, modify the text of the LabVIEW Terminal setting. For this example, enter Voltage_In and
Voltage_Out for the input and output terminals, respectively.

Стр. 4 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

7. The completed circuit consists of a voltage-controlled voltage source that is in series with an inductor, capacitor, and
resistor. The input voltage to the voltage-controlled voltage source comes from a control in LabVIEW, and the output of the
RLC filter circuit is passed back to LabVIEW to be visualized on a graph with the original input voltage for comparison. The
image below is a Multisim Design Snippet that you can drag and drop into your Multisim environment and it automatically
recreates the code. Read more information on Multisim Snippets (http://www.ni.com/white-paper/13668/en).

8. Save the Multisim design to a known location so you can retrieve it while you program in LabVIEW. You are now ready to
program the LabVIEW VI that communicates with this circuit in Multisim.
4. Create a Digital Controller in LabVIEW
1. To pass data back and forth between LabVIEW and Multisim, you must use a Control & Simulation Loop in LabVIEW.
Navigate to the block diagram in LabVIEW (white window), right-click to open the Functions Palette, and navigate to Control
Design & Simulation»Simulation»Control & Simulation Loop. Left-click and drag the loop onto the block diagram.

2. To modify the Solver and Timing settings of the Control & Simulation Loop, double-click the input terminal to the loop to
make the Configure Simulation Parameters window appear. Enter the parameters as seen in the figure below; these
settings provide effective results for plotting the data on a waveform chart in LabVIEW with the settings used later in the
tutorial. Tune these parameters to meet your needs.

Стр. 5 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

3. Now add the Halt Simulation function to your VI to stop the Control & Simulation Loop. Right-click the block diagram and
navigate to Control Design & Simulation»Simulation»Utilities»Halt Simulation. Left-click to place the Halt Simulation
function on the block diagram and then right-click the Boolean input of the Halt Simulation VI and select Create»Control. This
creates a Boolean control on the front panel that you can use to halt, or stop, the simulation while it is running.

4. Next, place the Multisim Design VI that facilitates the communication between the LabVIEW and Multisim simulation
engines. Right-click the block diagram and navigate to Control Design & Simulation»Simulation»External
Models»Multisim»Multisim Design and left-click to place the VI within the Control & Simulation Loop; it must be placed
within the loop.

The Select a Multisim Design dialog box appears after you place the Multisim Design VI. You now need to either specify the
file path or browse to the location by clicking the Browse button and locating the file on your hard disk.

The Multisim Design VI now populates the terminals, identically to the Multisim Design VI Preview within the Multisim
environment, with the proper inputs and outputs. Left-click on the double down-arrow and expand the terminals if they are not
visible.

5. To pass data to the Multisim design, you must first create a numeric control on the front panel. To easily accomplish this,

Стр. 6 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

right-click on the input, Voltage_In, and select Create»Control. This places a numeric control terminal on the block diagram
that is already wired to the input of the Multisim VI. The block diagram terminal for the control has a corresponding control on
the front panel, which is the user interface in LabVIEW. To quickly navigate between the block diagram and front panel, simply
press <Ctrl-E>.

If you want to change the appearance of the numeric control on the front panel, you can resize and move the control as you
wish. Also, you can replace the control with a dial, knob, slider, and so on by right-clicking on the control, selecting
Replace»Silver»Numeric, and then selecting the numeric control that you want. Double-click the maximum and minimum
values to change the range of the control. Use -25 and 25 for the minimum and maximum values, respectively.

6. To move data from Multisim to LabVIEW, you need to create an indicator to display the data. Because you are displaying
both the input voltage and the resulting output voltage from the Multisim circuit, a chart indicator works best. While on the front
panel, right-click on empty space and navigate to Silver»Graph»Waveform Chart (Silver). Resize accordingly.

7. To properly display the voltage input and the voltage output together, you need to build the signals into an array. Right-click
the block diagram and navigate to Programming»Array»Build Array and left-click to place the function on the block diagram.
Place your mouse pointer over the bottom middle of the Build Array function to reveal the resize anchors and then left-click
and drag to the function to resize the Build Array to receive two inputs. Wire the output from the voltage control into the top
input and wire the output from the Voltage_Out terminal of the Multisim Design VI to the bottom input. This creates a
one-dimensional array of two elements.

Стр. 7 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

8. Finally, you need to place the function to create a simulated time waveform within the loop to properly display the two
waveforms. Right-click the block diagram Control Design & Simulation»Simulation»Graph Utilities»Simulation Time
Waveform. This VI automatically places a waveform chart. Simply delete the newly created chart and rewire the output from
the Simulation Time Waveform VI to the input of the existing waveform chart. Wire the output from the Build Array function to
the input of the Simulation Time Waveform.

9. To produce a more readable waveform chart, navigate to the front panel, right-click Waveform Chart, and select Properties.
Navigate to the Display Format tab and select Automatic formatting for the Type input and 4 for the Digits input.

Then navigate to the Scales tab and deselect Autoscale for the Time (X-Axis). Finally, toggle from Time (X-Axis) to
Amplitude (Y-Axis) and deselect Autoscale. This holds the chart ranges to a constant range. Select OK to apply your
changes.

Стр. 8 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

10. Next, double-click the maximum and minimum inputs of the Amplitude scale and adjust to 40 and -40, respectively. This
allows for overshoot values to be displayed properly. Double-click the maximum of the Time axis and set this to 0.25, or 250
milliseconds.

11. Save the LabVIEW VI to a known location, preferably the same location as your Multisim design because they are paired
together. The image below is a LabVIEW VI Snippet that you can drag and drop into a blank LabVIEW VI, and it recreates the
code automatically. Click here for more information about LabVIEW VI Snippets (http://zone.ni.com/reference/en-XX
/help/371361G-01/lvhowto/create_visnippet/). You are now ready to perform a co-simulation between LabVIEW and Multisim.

Note: Some browsers do not support drag-and-drop LabVIEW VI Snippet functionality. An alternative method is to right-click
the image and choose Save image as… to save the image. You can then drag and drop the image file into a LabVIEW block
diagram to paste the code.

5. Performing Co-simulation Between LabVIEW and Multisim


Now that you have created the analog circuit and digital controller in Multisim and LabVIEW and you have established the
communication paths, you are ready to co-simulate between the two simulation environments and visualize the results on the
waveform chart on your LabVIEW front panel.
1. To begin the co-simulation, click the Run button on the LabVIEW toolbar. Multisim does not need to be open because an
instance of Multisim is opened and runs silently in the background. It takes between 5 and 30 seconds to launch the Multisim
instance and begin the co-simulation between the LabVIEW and Multisim simulation engines.

Стр. 9 из 10 15.05.2017 10:58


Introduction to Digital and Analog Co-simulation Between NI LabVI... http://www.ni.com/white-paper/13663/en/

2. Modify the input voltage in LabVIEW and observe the output voltage that is returned from the Multisim simulation engine.
Example results are shown below.

3. Modify the RLC circuit parameters in Multisim to alter how the circuit responds to a change in input voltage. To change the
parameters of the capacitance, resistance, and inductance during transient co-simulation, use a voltage-controlled capacitor,
resistor, and inductor in Multisim and pass control voltages to Multisim from LabVIEW controls.
6. Conclusion
As shown in the resulting waveform chart on the LabVIEW front panel, LabVIEW and Multisim can effectively and accurately
simulate the RLC response to multiple changes in the input voltage. In this example, LabVIEW acts as the digital controller,
setting the DC voltage level of the analog circuit that is simulated in Multisim. This is a simple yet fundamental circuit to show
the co-simulation behavior. More complex examples of LabVIEW and Multisim co-simulation are available.
7. Related Links
Download NI Multisim (http://www.ni.com/multisim/try)
How to Design and Simulate a Brushed DC Motor H-Bridge Circuit Using Multisim and LabVIEW (http://zone.ni.com/devzone
/cda/tut/p/id/13721)

Стр. 10 из 10 15.05.2017 10:58