Documente Academic
Documente Profesional
Documente Cultură
5i-M-R
EasyRET Dual-Beam Antenna with 2 Integrated RCUs - 1.4m
Model: AMB4520R0
Antenna Specifications
Electrical Properties
1710 - 2690
Frequency range (MHz)
1710 - 1990 1920 - 2200 2200 - 2490 2490 - 2690
Polarization +45° , -45°
Electrical downtilt (°) 0 - 10, continuously adjustable
at mid Tilt 19.2 19.7 20.0 20.2
Gain (dBi)
over all Tilts 19.0 ±0.6 19.5 ±0.6 19.8 ±0.5 20.0 ±0.8
Side lobe suppression for first side lobe
> 17 > 17 > 17 > 17
above main beam (dB)
Horizontal 3dB beam width (°) 34 ±2.1 31 ±2.3 29 ±0.5 27 ±1.0
Vertical 3dB beam width (°) 6.4 ±0.5 5.9 ±0.4 5.1 ±0.2 4.7 ±0.3
VSWR < 1.5
Horizontal beam centers (°) ± 30 ± 27 ± 25 ± 23
Cross polar isolation (dB) Same beam: ≥ 28
Front to back ratio, ±30° (dB) > 32 > 32 > 32 > 32
Cross polar ratio (dB) 0° > 20 > 20 > 22 > 22
Max. power per input (W) 250 (at 50℃ ambient temperature)
Intermodulation IM3 (dBc) ≤ -153 (2 x 43 dBm carrier)
Impedance (Ω) 50
Grounding DC Ground
Accessories
Item Model Description Weight Units per antenna
Downtilt 1 (Separate
ASMDT0C01 Mechanical downtilt: 0 - 16 ° 2.1 kg
kit packing)
ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7 (495) 109-02-08 sales@bbrc.ru www.bbrc.ru
232
2MX-1710-2690-33-20.5i-M-R
EasyRET Dual-Beam Antenna with 2 Integrated RCUs - 1.4m
Model: AMB4520R0
Properties
RET type Integrated RET
RET protocols* AISG 2.0 / 3GPP
Input voltage range (V) 10 - 30 DC
< 5 (motor activated, 12V)
Power consumption (W)
< 0.5 (stand by, 12V)
Adjustment time (full range) (s) < 65 (typically, depending on antenna type)
2 x 8 pin connector according to IEC 60130-9
RET connector
Daisy chain in: Male / Daisy chain out: Female
1 2 3 4 5 6 7 8
Pin assignment according AISG
DC n/c RS-485B n/c RS-485A DC DC return n/c
3 (10/350 μs)
Lightning protection (kA)
10 (8/20 μs)
* Please confirm the AISG protocol of primary station is compatible with RET antenna protocol interface. The protocol of RET antenna
software interface is switchable between AISG 2.0/3GPP and AISG 1.1 with a vendor defined command. For more details about protocol
switching function, contact Huawei before system installation.
Standards: UL 60950-1 (Safety), UL 60950-22 (Safety – Equipment installed outdoor), EN 55022 (Emission),
EN 55024 (Immunity), ETSI EN 301 489, FCC Part15, ICES-003
Certification: CE, FCC, IC, RCM
Multi-beam
HWMxxx…...y
HWMxxx….yy
y - Yellow