MasterLife® CI 222

Organic corrosion inhibiting admixture

DESCRIPTION PLASTIC PROPERTIES


MasterLife CI 222 is a state-of-the-art organic The plastic properties of concrete are not
migratory corrosion inhibiting admixture significantly affected by the use of
formulated to inhibit the corrosion of steel MasterLife CI 222
reinforcement in concrete. MasterLife CI 222
provides two levels of corrosion protection, SLUMP AND TEMPERATURE
inhibiting and waterproofing making it the most DEVELOPMENT
effective corrosion inhibiting admixture available. MasterLife CI 222 has no effect on slump or the
temperature development profile of concrete.
ADVANTAGES
MasterLife CI 222 extends the service life of CONCRETE-STEEL BOND STRENGTH
reinforced concrete by slowing the ingress of Concrete to steel bond strength is not affected by
chlorides and moisture into the concrete and by MasterLife CI 222.
forming a strong, durable protective film on the
reinforcing steel for a second level of corrosion
protection. This dual mechanism system makes CORROSION INHIBITING SYSTEMS
MasterLife CI 222 effective with all cement In order to control corrosion in steel reinforced
factors, as well as in cracked concrete where the concrete, the ACI Building Code (ACl 318)
elements that cause corrosion have direct requires certain design considerations, such as
access to the reinforcing steel. limiting the water-cementitious materials ratio;
providing adequate concrete cover over
PACKAGING reinforcing steel; and limiting the initial chloride
ion content of the concrete. Additionally,
MasterLife CI 222 is available in 208 litre drums construction practices should be such that a
and bulk if required. dense, void-free concrete is obtained.

STANDARDS In addition to the elements of good concrete


ASTM G109, ASTM C494, BS 6920 (confirms practice required by the ACI Building Code,
concrete containing MasterLife CI 222 is BASF recommends a corrosion inhibiting system
suitable for contact with water). that inhibits corrosion at multiple levels for
maximum protection.
HOW IT WORKS
The basis for this system can be established
MasterLife CI 222 functions by inhibiting
through the use of MasterLife CI 222 which
corrosion at its most critical points.
restricts the ingress of chlorides and moisture
MasterLife CI 222 lines the pores of the
and slows the rate of corrosion by forming a
concrete matrix thus waterproofing and slowing
protective film on the reinforcing steel. Additional
the rate at which chlorides and moisture enter
protection can be attained through the use of
the concrete and denying the corrosion process
high-range water-reducing admixtures to provide
of its two most important components.
adequate placeability and consolidation at low
MasterLife CI 222 provides additional protection
water-cement ratios and/or the use of silica fume
by migrating and adsorbing onto the reinforcing admixtures to reduce concrete permeability.
steel to form a corrosion resistant protective film.
This protective film dramatically slows the
corrosion process by preventing chlorides from
reacting with the reinforcing steel, and by
depriving the corrosion process of moisture and
oxygen, thus slowing the rate of corrosion once it
begins.
MasterLife® CI 222
DOSAGE NON-CHLORIDE
MasterLife CI 222 is recommended for use at a MasterLife CI 222 will not initiate or promote
dosage rate of 5 litre / m³ of concrete for all corrosion of reinforcing steel embedded in
applications and corrosion environments. concrete, prestressed concrete or concrete
MasterLife CI 222 dosed at 5 litre / m³ is placed on galvanised steel floor and roof
formulated to provide optimum corrosion systems. Neither calcium chloride nor any
protection of reinforced concrete structures in chloride-based ingredients are used in the
severe corrosive environments, and therefore manufacture of MasterLife CI 222 corrosion
provides excellent corrosive protection in less inhibiting admixture.
severe corrosion environments as well.
MasterLife CI 222 is formulated for use at a SAFETY PRECAUTIONS
single dosage in order to eliminate the confusion MasterLife CI 222 is not a fire or health hazard.
and uncertainties related to determining the
Spillages should be washed down immediately
severity of the corrosive environment and
with cold water. For further information refer to
predicting the chloride exposure of the structure.
the material safety data sheet.

DIRECTIONS FOR USE NOTE


MasterLife CI 222 may be added with concrete Field service, where provided, does not
batch water. It should not be mixed with any constitute supervisory responsibility. For
other admixtures prior to being introduced into additional information contact your local BASF
the concrete mixer. The use of this admixture representative.
does not require changes in normal batching BASF reserves the right to have the true cause
procedures. of any difficulty determined by accepted test
methods.
WATCHPOINTS
Trials must be carried out to ensure mix design QUALITY AND CARE
meets specified performance criteria. All products originating from BASF’s Dubai, UAE
facility are manufactured under a management
STORAGE system independently certified to conform to the
Store at ambient temperatures above 2°C but requirements of the quality, environmental and
not exceeding 52°C. Ensure that undiluted occupational health & safety standards
product does not reach ground water, water ISO 9001, ISO 14001 and ISO 45001.
course or sewage system.
® = Registered trademark of the BASF-Group in many countries.

BASF_CC-UAE/Life_CI222_01_96/v4/02_16/v5/04_19
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
not to the product mentioned on this
Tel: +971 4 8090800, Fax: +971 4 8851002
datasheet
www.master-builders-solutions.basf.ae