Today, the MI cable is the design standard for • The cable has a qualified life of 40 years, which can
typically be easily extended to 60 years.
in-containment Class 1E cable applications for
the System 80+ and AP1000 reactor designs, • It is a cost-effective solution compared to the
and is installed in over 60 pressurized water periodic procurement of custom-designed organic
reactors (PWRs) and boiling water reactors cables.
(BWRs) worldwide. • The cable's all-metal exterior leaves little doubt as to
Environmental Qualification (EQ) integrity.
Description
• The CET cable and connector upgrade reduces the
MI cable and connector assemblies are post-accident number of electrical disconnects by a factor of
qualified Class 1E hardware. The cable assemblies are 6 or 7.
hermetically sealed through an all-welded construction
technique that, in combination with the metallic sheath • Cable assemblies with maintenance-free interfacial
and inorganic materials, provide a high tolerance for seals are available with Grafoil interfacial connector
seals in place of traditional organic seals, thereby • Has demonstrated through independent laboratory
eliminating the need for periodic change-out due to testing that the thermally induced current (TIC) is
radiation or thermal effects. less than 0.0002 nano-amps per meter during typical
400°F LOCA transient.
• Provides immunity to electrical noise due to
insulation that provides superior dielectric strength Experience
properties at both ambient and elevated
temperatures. Superior noise and thermally MI cable and connector upgrades have been installed in
induced current resistance is supplied all along the the post-TMI era in over 60 PWRs and BWRs worldwide.
installed cable runs. Specific Class 1E applications include:
• Resists damage during and after a fire while • CET
maintaining low-signal error.
• In Core Instruments
• Eliminates mechanical damage of the electrical
connectors by using a large three-start ACME thread • Heated Junction Thermocouples (Level Indication)
on the coupling nut connection, glass-bonded
contacts, and an integral key and keyway system to • High Range Radiation Monitors
mechanically align the connector bodies well before
• NRC 10 CFR 50, Appendix R
the engagement of the pin and socket contacts.
• Achieves loss-of-coolant-accident/main-steamline-
break (LOCA/MSLB) conditions of 420°F and
60 psig.