Sunteți pe pagina 1din 13

]

KLAUS Multiparking GmbH PRODUCT DATA


]

Hermann-Krum-Straße 2
]

D-88319 Aitrach
]

Fon +49 (0 ) 75 65 5 08-0


]

2000 kg [4400 lbs]


Fax +49 (0 ) 75 65 5 08-88
1
info@multiparking.com
www.multiparking.com 2600 kg [5730 lbs] 2

Page 1 Loadable up to Single parking spaces can


also be upgraded to handle
2600 kg [5730 lbs] heavier loads at a later date!
25 145
Section
Free space Detail free space
[10‘‘] [4‘-9‘‘] see page 2
Car data

Dimensions
[1‘-6‘‘]

Tolerances for space


45

Page 2
requirements + 03 [+ 1’’
UF (upper floor)
3
Height 0 ]
dimensions

Dimensions: cm [ft] (1 cm = 0,393 in)


Weights: kg [lbs] (1 kg = 2.2 lbs)
Page 3 Forces: kN [lbf] (1 kN = 224.8 lbf)
Temperature: °C [°F] (0° C = 32° F)
Sliding door
width

see page 2 and 3


dimensions
GF (ground floor)
Suitable for

Detail doors
Standard passenger cars:
Page 4 Limousine, Station Sagon, SUV, Van
Sliding door
width
according to clearance and maximum
dimensions surface load.
Standard Special 2
4 190 cm [6‘-3‘‘] 4
Page 5 LF (lower floor) Width 190 cm [6‘-3‘‘]
Sliding door Grounding 5
width Weight max. 2000 kg max. 2600 kg
dimensions [max. 4400 lbs] [max. 5730 lbs]
Wheel load
max. 500 kg max. 650 kg
[max. 1100 lbs] [max. 1430 lbs]
Page 6 9
Roll door Clearance profile
width
dimensions 2% 2% 30
40 7 6 25 7
160 [5‘-3‘‘] [12‘‘]
Water drainage

[1‘-10‘‘]
[1‘-6‘‘]
[1‘-4‘‘] [10‘‘]

45

55
Page 7 550 +50 [18‘-1‘‘ +2‘‘
see table
0 ] for vehicle up to 5.00 m [16‘-5‘‘] long
Approach (570 +50 [18‘-8‘‘ +2‘‘ 8
0 ] for vehicle up to 5.20 m [17‘-1‘‘] long)
Free spaces 15° 13°
Function

100 125
[3‘-3‘‘] [4‘-1‘‘]
500 (520)

Page 8
[16‘-5‘‘ (17‘-1‘‘)]

Load plan

Height dimensions
See page 2 for all pit and height dimensions.
Page 9
Load plan

Page 10
[14‘-11‘‘]

Technical
455

data
[10‘-8‘‘]
325

Page 11
Electrical
To be perfor-
[7‘-10‘‘]

med by the
240
[5‘-9‘‘]

customer
175

Page 12
Description
Smallest type Biggest type
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018

Page 13
Description
1 Standard type 8 For convenient use of your parking space and due to the fact
2 Special system: maximum load for extra charge. that the cars keep becoming longer we recommend
a pit length of 570 cm [18’-8’’].
3 To follow the minimum finished dimensions, make sure
to consider the tolerances according to VOB, part C 9 At the transition section between pit floor and walls no hollow
(DIN 18330 and 18331) and the DIN 18202. mouldings/coves are possible. If hollow mouldings/coves are
required, the systems must be designed smaller or the pits
Car width for platform width 230 cm [7’-7’’]. If wider platforms accordingly wider.
4
are used it is also possible to park wider cars.
5 Potential equalization from foundation grounding connection If sprinklers are required make sure to provide the
to system (provided by the customer).
necessary free spaces during the planning stage.
6 Slope with drainage channel and sump.
7 These floor areas need to be horizontal and on equal level
across the full width of the pit
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 2 of 13
Page 1
Height dimensions
Section
Car data
4300-175 [5’-9’’] 4300-200 [6’-7’’]

Page 2
Height
dimensions

Height
Height
Page 3
Sliding door
width
dimensions

[5‘-9‘‘]

[6‘-7‘‘]
175

200
Page 4
Sliding door
width
dimensions

Car height Car height


Height UF GF LF Height UF GF LF
Page 5
Sliding door
325 [10‘-8‘‘] 150 [4‘-11‘‘] 150 [4‘-11‘‘] 150 [4‘-11‘‘] 350 [11‘-6‘‘] 150 [4‘-11‘‘] 175 [5‘-9‘‘ ] 175 [5‘-9‘‘ ]
width 345 [11‘-4‘‘] 150 [4‘-11‘‘]] 170 [5‘-7‘‘ ] 150 [4‘-11‘‘] 365 [12‘-0‘‘] 150 [4‘-11‘‘] 190 [6‘-3‘‘ ] 175 [5‘-9‘‘ ]
dimensions 365 [12‘-0‘‘] 150 [4‘-11‘‘] 190 [6‘-3‘‘ ] 150 [4‘-11‘‘] 375 [12‘-4‘‘] 175 [5‘-9‘‘ ] 175 [5‘-9‘‘ ] 175 [5‘-9‘‘ ]
365 [12‘-0‘‘] 170 [4‘-7‘‘ ] 170 [5‘-7‘‘ ] 150 [4‘-11‘‘] 380 [12‘-6‘‘] 150 [4‘-11‘‘] 205 [6‘-9‘‘ ] 175 [5‘-9‘‘ ]

Page 6
380 [12‘-6‘‘] 150 [4‘-11‘‘]] 205 [6‘-9‘‘ ] 150 [4‘-11‘‘] 405 [13‘-3‘‘] 175 [5‘-9‘‘ ] 205 [6‘-9‘‘ ] 175 [5‘-9‘‘ ]
Roll door
405 [13‘-3‘‘] 190 [6‘-3‘‘ ] 190 [6‘-3‘‘ ] 150 [4‘-11‘‘] 435 [14‘-3‘‘] 205 [6‘-9‘‘ ] 205 [6‘-9‘‘ ] 175 [5‘-9‘‘ ]
width 435 [14‘-3‘‘] 205 [6‘-9‘‘ ] 205 [6‘-9‘‘ ] 150 [4‘-11‘‘]
dimensions

Page 7
Approach
4300-230 [7’-7’’] 4300-240 [7’-10’’]
Free spaces
Function

Page 8
Load plan

Height
Height

Page 9
Load plan

Page 10
[7‘-10‘‘]
[7‘-7‘‘]
230

240
Technical
data

Page 11
Car height Car height
Electrical Height UF GF LF Height UF GF LF
To be perfor- 390 [12‘-10‘‘] 150 215 [7‘-1‘‘] 215
med by the
380 [12‘-6‘‘] 150 [4‘-11‘‘] 205 [6‘-9‘‘] 205 [6‘-9‘‘] [4‘-11‘‘] [7‘-1‘‘]
customer 405 [13‘-3‘‘] 175 [5‘-9‘‘ ] 205 [6‘-9‘‘] 205 [6‘-9‘‘] 405 [13‘-3‘‘ ] 165 [5‘-5‘‘ ] 215 [7‘-1‘‘] 215 [7‘-1‘‘]
420 [19‘-9‘‘] 190 [6‘-3‘‘ ] 205 [6‘-9‘‘] 205 [6‘-9‘‘] 415 [13‘-7‘‘ ] 175 [5‘-9‘‘ ] 215 [7‘-1‘‘] 215 [7‘-1‘‘]
Page 12 435 [14‘-3‘‘] 205 [6‘-9‘‘ ] 205 [6‘-9‘‘] 205 [6‘-9‘‘] 435 [14‘-3‘‘ ] 195 [6‘-5‘‘ ] 215 [7‘-1‘‘] 215 [7‘-1‘‘]
Description 445 [14‘-7‘‘ ] 205 [6‘-9‘‘ ] 215 [7‘-1‘‘] 215 [7‘-1‘‘]
455 [14‘-11‘‘] 215 [7‘-1‘‘ ] 215 [7‘-1‘‘] 215 [7‘-1‘‘]
]
]
Page 13
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 3 of 13
Page 1
Garages with sliding doors (standard) | Widths dimensions
Section
Car data Sliding door behind columns

30 45
Page 2 [12‘‘] [1‘6‘‘]
Height Type GT Height H1
dimensions 4300 175 325/345/365/405 210
Free

[1‘-10‘‘]
55
[5‘-9‘‘] [10‘-8‘‘/11‘-4‘‘/12‘-0‘‘/13‘-3‘‘] [6‘-11‘‘]
space
25 11
4300 175 380/435 220
[5‘-9‘‘] [12‘-6‘‘/14‘-3‘‘] [7‘-3‘‘]
Page 3 [10‘‘] 4300 200 350/365/375 210
Sliding door [6‘-7‘‘] [11‘-6‘‘/12‘-0‘‘/12‘-4‘‘] [6‘-11‘‘]
width

Height
dimensions
4300 200 380/405/435 220
[6‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/14‘-3‘‘] [7‘-3‘‘]
4300 230 380/405/420/435 220

H1
[7‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/13‘-9‘‘/14‘-3‘‘] [7‘-3‘‘]
Page 4 4300 240 390/405/415/435/445/455 230
Sliding door

[12‘‘]
width
[7‘-10‘‘] [12‘-10‘‘/13‘-3‘‘/13‘-7‘‘/14‘-3‘‘/14‘-7‘‘/14‘-11‘‘] [7‘-7‘‘]

30
dimensions

Page 5

GT
Sliding door
width
dimensions

550 (570)
Page 6 [18‘-1‘‘ (18‘8‘‘)]
Roll door ] ] ] ]
width
dimensions
2 2 ] 2 ] 2
Columns per each grid unit
2 2

Page 7
RB 10
Approach
Usable platform width B1 B2
Free spaces
230 [7‘-7‘‘ ]] 250 [8‘-2‘‘ ]] 250 [8‘-2‘‘ ]] 230 [7‘-7‘‘ ]]
240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ]] 260 [8‘-6‘‘ ]] 240 [7‘-10‘‘ ]
Function
RB RB RB 2 2 2 2
250 [8‘-2‘‘ ] 270
2 [8‘-10‘‘] 270
2 [8‘-10‘‘] 250 [8‘-2‘‘ ]]
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ] 280 [9‘-2‘‘ ] 260 [8‘-6‘‘ ]]
Page 8
10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ] 290 [9‘-6‘‘ ] 270 [8‘-10‘‘]
Load plan [4‘‘]

20
Page 9
(B2) Carriageway in
[8‘‘]
Load plan
accordance with
B1 B2 local regulations
No. of grids x RB + 20 [8‘‘]

Page 10
Technical Columns every second grid unit
data

Usable platform width RB 10 B3 B4


230 [7‘-7‘‘ ] 250 [8‘-2‘‘ ] 500 [16‘-5‘‘ ] 480 [15‘-9‘‘ ]
Page 11 RB RB RB RB 240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ] 520 [17‘-1‘‘ ] 500 [16‘-5‘‘ ]
Electrical 250 [8‘-2‘‘ ] 270 [8‘-10‘‘] 540 [17‘-9‘‘] 520 [17‘-1‘‘]
To be perfor-
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ] 560 [18‘-4‘‘] 540 [17‘-9‘‘]
med by the 10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ] 580 [19‘-0‘‘] 560 [18‘-4‘‘]
customer [4‘‘]
]] ]]
Page 12 2 2 ]]
2 2
Description 2
2
20 Carriageway in
(B4) accordance with
[8‘‘] local regulations
B3 B4
Page 13 No. of grids x RB + 20 [8‘‘]
Description

According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm [8’-10’’].
Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).

10 RB = Grid unit width must strictly conform to dimensions quoted!


11 Only applies to manually operated doors. The electrically driven doors must have 35 cm [1’-2’’].
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 4 of 13
Page 1
Garages with sliding doors (standard) | Widths dimensions
Section
Car data Sliding door between columns

30 20
Page 2 [12‘‘] [8‘‘]
Height Type GT Height H1
dimensions 4300 175 325/345/365/405 220
Free

[1‘-10‘‘]
55
[5‘-9‘‘] [10‘-8‘‘/11‘-4‘‘/12‘-0‘‘/13‘-3‘‘] [7‘-3‘‘]
space
25 11
4300 175 380/435 230
[5‘-9‘‘] [12‘-6‘‘/14‘-3‘‘] [7‘-7‘‘]
Page 3 [10‘‘] 4300 200 350/365/375 220
Sliding door [6‘-7‘‘] [11‘-6‘‘/12‘-0‘‘/12‘-4‘‘] [7‘-3‘‘]
width

Height
dimensions
4300 200 380/405/435 230
[6‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/14‘-3‘‘] [7‘-7‘‘]
4300 230 380/405/420/435 230

H1
[7‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/13‘-9‘‘/14‘-3‘‘] [7‘-7‘‘]
Page 4 4300 240 390/405/415/435/445/455 240
Sliding door
width
[7‘-10‘‘] [12‘-10‘‘/13‘-3‘‘/13‘-7‘‘/14‘-3‘‘/14‘-7‘‘/14‘-11‘‘] [7‘-10‘‘]
dimensions

Page 5

GT
Sliding door
width
dimensions

550 (570)
Page 6 [18‘-1‘‘ (18‘8‘‘)]
Roll door
width
dimensions
Columns per each grid unit

Page 7 Not available!


Approach
Free spaces
Function
Columns every second grid unit

Page 8
RB 10
Load plan
Usable platform width B3 B4
230 [7‘-7‘‘ ] 250 [8‘-2‘‘ ] 500 [16‘-5‘‘ ] 480 [15‘-9‘‘ ]
RB RB RB RB 240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ] 520 [17‘-1‘‘ ] 500 [16‘-5‘‘ ]
250 [8‘-2‘‘ ] 270 [8‘-10‘‘] 540 [17‘-9‘‘] 520 [17‘-1‘‘]
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ] 560 [18‘-4‘‘] 540 [17‘-9‘‘]
Page 9 10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ] 580 [19‘-0‘‘] 560 [18‘-4‘‘]
Load plan [4‘‘]

20 Carriageway in
(B4) accordance with
[8‘‘] local regulations
B3 B4
Page 10
Technical No. of grids x RB + 20 [8‘‘]
data

Page 11
Electrical According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
To be perfor- and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
med by the to be carried out independent of any maintenance work.
customer
For parking boxes on the edges and boxes with intermediate walls we recommend ]]our maximum platform width of 270 cm [8’-10’’].
Please consider adjoining grids. Problems may occur if smaller platform 2widths are used (depending]]on car type, access and
]]
Page 12
individual driving behaviour and capability).
2 22
Description ] 22
For larger limousines and SUV wider driveways are necessary (in particular on the ]boxes on the sides due to the missing
manoeuvring radius).

RB = Grid unit width must strictly conform to dimensions quoted!


Page 13
10
Description
11 Only applies to manually operated doors. The electrically driven doors must have 35 cm [1’-2’’].
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 5 of 13
Page 1
Garages with sliding doors (standard) | Widths dimensions
Section
Car data Sliding door in front of columns

30 20 Free
Page 2 [12‘‘] [8‘‘] space
Height Type GT Height H1
dimensions 4300 175 325/345/365/405 220

[1‘-10‘‘]
55
[5‘-9‘‘] [10‘-8‘‘/11‘-4‘‘/12‘-0‘‘/13‘-3‘‘] [7‘-3‘‘]
2511
4300 175 380/435 230

[4‘‘]
10
[5‘-9‘‘] [12‘-6‘‘/14‘-3‘‘] [7‘-7‘‘]
Page 3 [10‘‘] 4300 200 350/365/375 220
Sliding door [6‘-7‘‘] [11‘-6‘‘/12‘-0‘‘/12‘-4‘‘] [7‘-3‘‘]
width
dimensions
4300 200 380/405/435 230

Height
[6‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/14‘-3‘‘] [7‘-7‘‘]
4300 230 380/405/420/435 230

H1
[7‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/13‘-9‘‘/14‘-3‘‘] [7‘-7‘‘]
Page 4 4300 240 390/405/415/435/445/455 240
Sliding door
width
[7‘-10‘‘] [12‘-10‘‘/13‘-3‘‘/13‘-7‘‘/14‘-3‘‘/14‘-7‘‘/14‘-11‘‘] [7‘-10‘‘]
dimensions

Page 5

GT
Sliding door
width
dimensions

Page 6
550 (570)
Roll door [18‘-1‘‘ (18‘8‘‘)] ] ] ] ]
width
dimensions
2 2 ] 2 ] 2
Columns per each grid unit
2 2
]
]
Page 7
RB 10
Approach
Usable platform width B1 B2
Free spaces
230 [7‘-7‘‘ ]] 250 [8‘-2‘‘ ]] 250 [8‘-2‘‘ ]] 230 [7‘-7‘‘ ]]
240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ]] 260 [8‘-6‘‘ ]] 240 [7‘-10‘‘ ]
Function
RB RB RB 2 2 2 2
250 [8‘-2‘‘ ] 270
2 [8‘-10‘‘] 270
2 [8‘-10‘‘] 250 [8‘-2‘‘ ]]
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ]] 280 [9‘-2‘‘ ] 260 [8‘-6‘‘ ]]
Page 8
10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ]] 290 [9‘-6‘‘ ] 270 [8‘-10‘‘]
(25) 11

Load plan [4‘‘]


[10‘‘]

20
Page 9
(B2) Carriageway in
[8‘‘]
Load plan
accordance with
B1 B2 local regulations
No. of grids x RB + 20 [8‘‘]

Page 10
Technical Columns every second grid unit
data

Usable platform width RB 10 B3 B4


230 [7‘-7‘‘ ] 250 [8‘-2‘‘ ] 500 [16‘-5‘‘ ] 480 [15‘-9‘‘ ]
Page 11 RB RB RB RB 240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ] 520 [17‘-1‘‘ ] 500 [16‘-5‘‘ ]
Electrical 250 [8‘-2‘‘ ] 270 [8‘-10‘‘] 540 [17‘-9‘‘] 520 [17‘-1‘‘]
To be perfor-
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ] 560 [18‘-4‘‘] 540 [17‘-9‘‘]
med by the 10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ] 580 [19‘-0‘‘] 560 [18‘-4‘‘]
customer
(25) 11

[4‘‘]
[10‘‘]

]] ]]
Page 12 22 22 ]]
Description 22
Carriageway in ]
(B4) 20
accordance with ]
[8‘‘] local regulations
B3 B4
Page 13
No. of grids x RB + 20 [8‘‘]
Description

According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm [8’-10’’].
Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).

10 RB = Grid unit width must strictly conform to dimensions quoted!


11 Only applies to manually operated doors. The electrically driven doors must have 35 cm [1’-2’’].
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 6 of 13
Page 1
Garages with roll doors | Widths dimensions
Section
Car data Roll door behind columns

30 35
Page 2 [12‘‘] [1‘-2‘‘]
Height Type GT Height H1
dimensions 4300 175 325/345/365/405 210

H2 13
[5‘-9‘‘] [10‘-8‘‘/11‘-4‘‘/12‘-0‘‘/13‘-3‘‘] [6‘-11‘‘]
4300 175 380/435 220
[5‘-9‘‘] [12‘-6‘‘/14‘-3‘‘] [7‘-3‘‘]
Page 3 4300 200 350/365/375 210
Sliding door [6‘-7‘‘] [11‘-6‘‘/12‘-0‘‘/12‘-4‘‘] [6‘-11‘‘]
width

Height
dimensions
4300 200 380/405/435 220

[9‘-10‘‘]
[6‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/14‘-3‘‘] [7‘-3‘‘]

300
4300 230 380/405/420/435 220

H1
[7‘-7‘‘] [12‘-6‘‘/13‘-3‘‘/13‘-9‘‘/14‘-3‘‘] [7‘-3‘‘]
Page 4 4300 240 390/405/415/435/445/455 230
Sliding door

[12‘‘]
width
[7‘-10‘‘] [12‘-10‘‘/13‘-3‘‘/13‘-7‘‘/14‘-3‘‘/14‘-7‘‘/14‘-11‘‘] [7‘-7‘‘]

30
dimensions

15
Page 5 [6‘‘]

GT
Sliding door
width
dimensions

550 (570)
Page 6 [18‘-1‘‘ (18‘8‘‘)]
Roll door
width
dimensions
Columns per each grid unit

Page 7
RB 12
Approach
Usable platform width B5 B6
Free spaces
230 [7‘-7‘‘ ]] 250 [8‘-2‘‘ ]] 250 [8‘-2‘‘ ]] 230 [7‘-7‘‘ ]]
240 [7‘-10‘‘ ] 260 [8‘-6‘‘ ]] 260 [8‘-6‘‘ ]] 240 [7‘-10‘‘ ]
Function
RB RB RB 2 2 2 2
250 [8‘-2‘‘ ] 270
2 [8‘-10‘‘] 270
2 [8‘-10‘‘] 250 [8‘-2‘‘ ]
260 [8‘-6‘‘ ] 280 [9‘-2‘‘ ] 280 [9‘-2‘‘ ]] 260 [8‘-6‘‘ ]
Page 8
10 270 [8‘-10‘‘] 290 [9‘-6‘‘ ] 290 [9‘-6‘‘ ]] 270 [8‘-10‘‘]
Load plan [4‘‘]

Page 9 20 20 20 Carriageway in
Load plan [8‘‘] [8‘‘] [8‘‘] accordance with
B5 B6 local regulations

No. of grids x RB + 20 [8‘‘]


Page 10
Technical
data According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
Page 11 For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm [8’-10’’].
Electrical Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
To be perfor- individual driving behaviour and capability).
med by the
customer For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).
Page 12
Description 12 RB = Grid unit width must strictly conform to dimensions quoted!
13 H2 for heigth >360 cm [>11’-10’’] = 20 [8’’] / H2 for heigth ≥380 [>12’-6’’] = 75 [2’-6’’]

Page 13
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 7 of 13
Page 1
Approach
Section
Car data

Page 2
Height
dimensions

Page 3 Maximum Maximum


Sliding door descending ascending
width slope 3 % slope 5 %
dimensions

The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious
Page 4 maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking
Sliding door accepts no responsibility.
width
dimensions

Longitudinal free space


Page 5
Sliding door
width
dimensions
10 RB 14 RB RB RB
[4‘‘] Longitudinal
Page 6 free space
Roll door
width
dimensions
20
[1‘-6‘‘]
45

[8‘‘]

Page 7
Approach
Empty Entrance level
space
Free spaces
Function

Page 8
Load plan

14 RB = Grid unit width must strictly conform to dimensions quoted!

Page 9
Load plan

Function with standard numbering and identification of parking levels


Page 10 e.g. for parking space No. 8:
Technical Check first that all doors are closed, then select No. 8 on operating panel.
data

Entrance level
UF 1 3 6 1 3 6 1 3 6
Page 11
Electrical
To be perfor-
GF 4 7 4 7 4 7 8
med by the
customer
2 5 8 2 5 8 2 5
Page 12
LF

Description

For driving the vehicle off platform The empty space is now below the vehicle The vehicle on platform No. 8
Page 13
No. 8 the ground floor parking which shall be driven off the platform. The can now be driven off the platform.
platforms are shifted to the left. platform No. 8 will be lifted.
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 8 of 13
Page 1
Load plan
Section
Car data 4300-175 [5’-9’’] 4300-200 [6’-7’’]

Page 2 F1
Height
dimensions F6
F1

H3
F6

Height
H3
Page 3
F1

Height
Sliding door
F1

H4
width

[6‘-1‘‘]
185
dimensions

H4
[6‘-1‘‘]
185

F1 F2
Page 4 F1 F2 F7
Sliding door F7
width

[6‘-5‘‘]
195

[6‘-7‘‘]
[5‘-7‘‘]

[5‘-9‘‘]
dimensions

[5‘-2‘‘]

200
170

175

160
[4‘-5‘‘]
135

F3 F4 F5 F8 F9 F3 F4 F5 F8 F9

Page 5
Sliding door 6 6
width
6 6
dimensions [2‘‘] 550 (570) [2‘‘] [2‘‘] 550 (570) [2‘‘]
[18‘-1‘‘ (18‘8‘‘)] [18‘-1‘‘ (18‘8‘‘)]
Page 6
Roll door
Type 4300-175 [5‘-9‘‘] Type 4300-200 [6‘-7‘‘]
width
Car height Car height
dimensions Height GF H3 H4 Height GF H3 H4
325 [10‘-8‘‘] 150 [4‘-11‘‘] 130 [4‘-3‘‘] 245 [8‘-0‘‘] 350 [11‘-6‘‘] 175 [5‘-9‘‘] 155 [5‘-1‘‘] 270 [8‘-10‘‘]
345 [11‘-4‘‘] 170 [5‘-7‘‘] 150 [4‘-11‘‘] 265 [8‘-8‘‘] 365 [12‘-0‘‘] 190 [6‘-3‘‘] 155 [5‘-1‘‘] 270 [8‘-10‘‘]
Page 7
365 [12‘-0‘‘] 190 [6‘-3‘‘] 170 [5‘-7‘‘] 285 [9‘-4‘‘] 375 [12‘-4‘‘] 175 [5‘-9‘‘] 155 [5‘-1‘‘] 270 [8‘-10‘‘]
Approach
365 [12‘-0‘‘] 170 [5‘-7‘‘] 150 [4‘-11‘‘] 265 [8‘-8‘‘] 380 [12‘-6‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘]
Free spaces
380 [12‘-6‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘] 405 [13‘-3‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘]
Function
405 [13‘-3‘‘] 190 [6‘-3‘‘] 170 [5‘-7‘‘] 285 [9‘-4‘‘] 435 [14‘-3‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘]
435 [14‘-3‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘]

Page 8
Load plan 4300-230 [7’-7’’] 4300-240 [7’-10’’]

F1
Page 9 F6
Load plan
F1
F6
H3
H3

Height
Height

Page 10 F1
Technical
H4

F1
data
H4

[6‘-1‘‘]
185
[6‘-1‘‘]
185

F1 F2
Page 11 F1 F2
Electrical
F7
F7
To be perfor-
[7‘-10‘‘]

med by the
[7‘-9‘‘]
[7‘-5‘‘]

[7‘-7‘‘]

240

customer
235

[6‘-7‘‘]
225

230

200
[6‘-3‘‘]
190

Page 12
F3 F4 F5 F3 F4 F5 F8 F9
Description
F8 F9

6 6 6 6
[2‘‘] 550 (570) [2‘‘] [2‘‘] 550 (570) [2‘‘]
Page 13
[18‘-1‘‘ (18‘8‘‘)]
Description
[18‘-1‘‘ (18‘8‘‘)]

Type 4300-230 [7‘-7‘‘] Type 4300-240 [7‘-10‘‘]


Car height Car height
Height GF H3 H4 Height GF H3 H4
380 [12‘-6‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘] 390 [12‘-11‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
405 [13‘-3‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘] 405 [13‘-3‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
420 [13‘-9‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘] 415 [13‘-7‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
435 [14‘-3‘‘] 205 [6‘-9‘‘] 185 [6‘-1‘‘] 300 [9‘-10‘‘] 435 [14‘-3‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
445 [14‘-7‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
455 [14‘-11‘‘] 215 [7‘-1‘‘] 195 [6‘-5‘‘] 310 [10‘-2‘‘]
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 9 of 13
Page 1
Load plan
Section
Car data Load plan – top view
RB2 RB RB RB RB
Page 2
Height F3 F4 F5 F4 F5 F4 F5 F4 F5 F4 F3
dimensions

F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2

Page 3
Sliding door
width
dimensions

Page 4 F6 F7 F6 F7 F6 F7 F6 F7 F6 F7 F6 F7
Sliding door
width
dimensions F8 F9 F9 F9 F9 F8

RB1 RB RB RB RB1
Page 5
Sliding door
width
dimensions
Usable platform width RB 15 RB1 RB2
230 [7‘-7‘‘] 250 [8‘-2‘‘] 260 [8‘-6‘‘] 135 [4‘-5‘‘]
240 [7‘-10‘‘] 260 [8‘-6‘‘] 270 [8‘-10‘‘] 140 [4‘-7‘‘]
Page 6
250 [8‘-2‘‘] 270 [8‘-10‘‘] 280 [9‘-2‘‘] 145 [4‘-9‘‘]
Roll door
260 [8‘-6‘‘] 280 [9‘-2‘‘] 290 [9‘-6‘‘] 150 [4‘-11‘‘]
width
270 [8‘-10‘‘] 290 [9‘-6‘‘] 300 [9‘-10‘‘] 155 [5‘-1‘‘]
dimensions

Platform load in kg
Page 7 Platform load F1 F2 F3 F4 F5 F6 F7 F8 F9 16
Approach 2000 kg +70 +25 +50
Free spaces
±5 ±2,5 ±14,5 ±29 ±0,2 ±2,5
2600 kg ±5 ±2,5 ±14,5 +80 ±29 ±0,2 ±2,5 +35 +70
Function

Platform load in lbs


Page 8
Load plan Platform load F1 F2 F3 F4 F5 F6 F7 F8 F9 17
4400 lbs ±1,124 ±562 ±3,259 +15,736 ±6,519 ±45 ±562 +5,620 +11,240
5730 lbs ±1,124 ±562 ±3,259 +17,984 ±6,519 ±45 ±562 +7,868 +15,736

Page 9
Load plan The system is dowelled to floor and walls. The drilling depth in the floor is approx. 15 cm [6’’].
The drilling depth in the walls is approx. 12 cm [5’’].
Floor and walls are to be made of concrete (grade of concrete min. C20/25)!
The dimensions for the points of support are rounded values. If the exact position is required, please contact
Page 10 KLAUS Multiparking.
Technical
data
15 RB = Grid unit width must strictly conform to dimensions quoted!
16 All forces in kN
Page 11 17 All forces in lbf
Electrical
To be perfor-
med by the
customer

Page 12
Description

Page 13
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 10 of 13
Page 1
Technical data
Section
Car data Field of application Environmental conditions
By default, the system can only be used for a fixed number of Environmental conditions for the area of multiparking systems:
users. Temperature range -10 to +40° C [+14 to +104° F].
Page 2 If different users use the system (e.g. short-time parkers in office Relative humidity 50% at a maximum outside temperature
Height
dimensions
buildings or hotels) the Multiparking system needs to be adjusted. of +40° C [+104° F].
If required, would you please contact us. If lifting or lowering times are specified, they refer to an
environmental temperature of +10° C [+50° F] and with the
Available documents system set up directly next to the hydraulic unit. At lower
Page 3 – wall recess plans temperatures or with longer hydraulic lines, these times
Sliding door – maintenance offer/contract increase.
– declaration of conformity
width
Electrically driven doors
dimensions
– test sheet on airborne and slid-borne sound
In accordance with BGR 232 commercially used power-driven
Page 4 Numbering doors must be subjected to annual inspections. We urgently
Sliding door Standard numbering of the parking spaces: recommend concluding a maintenance agreement that includes
width this service for the entire system.
dimensions

Building application documents


1 3 6 9 6

Page 5 According to LBO and GaVo (garage regulations) the Multiparking


systems are subject to approval. We will provide the required
Empty Entrance level
Sliding door
4 7 10 7

building application documents.


space
width
dimensions

Care
2 5 8 11 8

Page 6 Initial position: lower floor platform No. 2 at entrance level To avoid damages resulting from corrosion, make sure to follow
Roll door (covering of pit; safety regulation). our cleaning and care instructions and to provide good ventilation
width of your garage.
dimensions Different numbering is only possible at extra cost
Please take note of the following specifications: Corrosion protection
Page 7 – In general, the empty space must be arranged to the left. See separate sheet regarding corrosion protection.
Approach – The numbers must be provided 8 – 10 weeks before the
Free spaces delivery date. CE Certification
Function The systems on offer comply with DIN EN 14010 and
Sound insulation EC Machine Directive 2006/42/EC. Furthermore, this system
Page 8 As per DIN 4109-1 (sound insulation in building construction), underwent voluntary conformity testing by TÜV SÜD.
Load plan Section 9, KLAUS Multiparker are in the range of technical
domestic installations (garage systems).

Normal sound insulation:


Page 9 DIN 4109-1, Section 9, maximum permissible A-rated sound
Load plan levels in rooms requiring external protection, generated by
technical domestic installations and commercial businesses
affiliated with the building.
Table 9 shows the values for the maximum permissible A-rated
Page 10 sound levels in rooms requiring external protection, generated
Technical by technical domestic installations and business affiliated with
the building. As per line 2, the maximum sound level in living
data

rooms and bedrooms must not exceed 30 dB (A). User noises


are not subject to the requirements (DIN 4109-1, Section 9).
Page 11 The following measures are required to comply with this value:
Electrical
– Sound protection package according to offer/order
To be perfor-
med by the
(KLAUS Multiparking GmbH)
customer – Minimum sound insulation of the building of min. R’w = 57 dB
(service/item to be provided by the customer)
Page 12
Description Increased sound insulation (special agreement):
VDI 4100 (sound insulation in building construction)
Assessment and proposals for enhanced sound insulation.
Page 13 Agreement: Maximum sound level in living rooms and
Description bedrooms 25 dB (A). User noises are not subject to the
requirements (see VDI 4100, Paragraph 1, Scope of
application – Notes).
The following measures are required to comply with this value:
– Sound protection package according to offer/order
(KLAUS Multiparking GmbH)
– Minimum sound insulation of the building of min. R’w = 62 dB
(service/item to be provided by the customer)

Note: User noises are basically noises that can be individually


influenced by the user of our Multiparking systems. These
include, for example, driving on the platform, slamming vehicle
doors, engine and brake noises.
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 11 of 13
Page 1
Electrical data
Section
Car data Control box Electrical supply to the control box / Foundation earth connector
The control box must be accessible at all times from outside! Hydraulic unit 3 kW, 230/400 V / 50 Hz:
Dimensions approx. 100 x 100 x 30 cm [3’-3’’ x 3’-3’’ x 12’’]. Suitable electrical supply min. 5 x 2,5 mm2 (3 PH+N+PE)
Page 2 to control box with main fuse 3 x 16 A slow or over-current
Height Cutting through of wall from control box to parking system cut-out 3 x 16 A.
dimensions (contact the local agency of KLAUS Multiparking for clarification). Trigger characteristic K or C. DIN/VDE and local regulations
must be taken into consideration.
Hydraulic unit 4 kW, 120/208 V / 60 Hz:
Page 3 Suitable electrical supply min. 5 x AWG 12 to control box with
Sliding door main fuse 3 x 25 A slow or over-current cut-out 3 x 25 A.
Cutting through
width
dimensions Trigger characteristic K or C. DIN/VDE and local regulations
must be taken into consideration.
Suitable electrical supply to the control box must be provided by the
Page 4 customer during installation. The functionality can be monitored on
Sliding door site by our fitters together with the electrician. If this cannot be done
width
dimensions during installation for some reason for which the customer is
responsible, the customer must commission an electrician at their
own expense and risk.
Parking system fully visible
from control box
Page 5 In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Sliding door
Operating device Equipment), grounding of the steel structure is necessary, provided
width
by the customer (distance between grounding max. 10 m [32’-10’’]).
dimensions
Easy-to-survey positioning (e.g. on column).
Protection against unauthorized use.
Page 6 May also be recessed in wall if required.
Roll door
width
dimensions

To be performed by the customer


Page 7
Approach Safety fences Strip footings
Free spaces Any constraints that may be necessary according to DIN EN ISO If due to structural conditions strip footings must be effected, the
Function 13857 in order to provide protection for the park pits for pathways customer shall provide an accessible platform reaching to the top
directly in front, next to or behind the unit. This is also valid during of the said strip footings to enable and facilitate themounting work.
Page 8 construction.
Load plan Electrical supply to the control box / Foundation earth connector
Numbering of parking spaces Suitable electrical supply to the control box must be provided by
Consecutive numbering of parking spaces. the customer during installation. The functionality can be monitored
on site by our fitters together with the electrician. If this cannot be
Page 9 Building services done during installation for some reason for which the customer is
Load plan Any required lighting, ventilation, fire extinguishing and fire alarm responsible, the customer must commission an electrician at their
systems as well as clarification and compliance with the relevant own expense and risk.
regulatory requirements. In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Equipment), grounding of the steel structure is necessary, provided
Page 10
Drainage by the customer (distance between grounding max. 10 m [32’-10’’]).
Technical For the middle area of the pit we recommend a drainage channel,
data which you connect to a floor drain system or sump (50 x 50 x 20 cm) Door suspension
[1’-8’’ x 1’-8’’ x 8’’]. The drainage channel may be inclined to the side, The lintel height H2 (see page 2) is absolutely necessary. With
however not the pit floor itself (longitudinal incline is available). In the differing heights, additional fixings are required for extra charge.
Page 11
interests of environmental protection we recommend painting the pit
floor. Oil and petrol separators must be provided according to the sta- Door shields
Electrical
tutory provisions when connecting to the public sewage system! Door shields that may be necessary. If desired, they can be ordered
To be perfor-
med by the from KLAUS Multiparking for an additional charge.
customer Wall cuttings
Page 12
Any necessary wall cuttings. If the following are not included in the quotation, they will also
Description
have to be provided / paid for by the customer:
– Costs for final technical approval by an authorized body

Page 13
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 12 of 13
Page 1
Description
Section
Car data General description: Hydraulic unit consisting of:
Multiparking system providing independent parking spaces for cars, – Hydraulic power unit (low-noise, installed onto a console with a
one on top of the other and side by side. rubber-bonded-to-metal mounting)
Page 2
Dimensions are in accordance with the underlying dimensions of – Hydraulic oil reservoir
Height
dimensions parking pit, height and width. – Oil filling
The parking bays are accessed horizontally (installation – Internal geared wheel pump
deviation ± 1%). – Pump holder
– Clutch
Page 3
Along the complete width of the parking automat an approach lane – AC-motor (3 kW, 230/400 V, 50 Hz,
Sliding door
(driving lane in accordance with local regulations) must be available. alternative 4 kW, 120/208 V / 60 Hz)
width Parking spaces are arranged on three different levels, one level on – Motor circuit breaker
dimensions top of the other. – Test manometer
The platforms of both the lower floor (LF) and upper floor (UF) are – Pressure relief valve
moved vertically, the platforms of the ground floor (GF) horizontally. – Hydraulic hoses (which reduce noise transmission onto the
At approach level (GF) there is always one parking space less
Page 4
Sliding door hydraulic pipe
width available. This vacant space is used for shifting the ground floor (GF)
dimensions parking spaces sideways, thus enabling an upper floor (UF) parking Control system:
space or lower floor (LF) parking space to be lowered or lifted to ap- – Central control panel (operating device) used to select the desired
proach level. Consequently, a unit of five parking spaces (2 on the parking space
Page 5 upper floor, 1 on the ground floor, 2 on the lower floor) is the smallest – With series installation, the doors are opened manually
Sliding door unit available for this parking system. If desired, this can also be done using electric motors
width
dimensions The TrendVario 4300 allows parking of passenger cars and station – Electric wiring is made from the electric cabinet by the manufacturer
wagons.
For safety reasons the platforms can only be moved behind Roller doors:
Page 6 locked doors. Size
All necessary safety devices are installed. This consists mainly of
Roll door
width Dimensions modified based on width and height measurements.
dimensions a chain monitoring system, locking lever for the upper and lower
platforms and locked doors. The doors can only be opened if the Shutter box
selected parking space has reached the park position and all
– multipart extruded aluminium box 20°
Page 7 openings are secured.
Approach
– lacquered type
A steel framework mounted inside the pit, consisting of:
Guide rails
Free spaces
Function
– Seriated supports – extruded aluminium guide rails with brush insert
– Steel pillars with sliding platform supports – lacquered type
Page 8 – Cross and longitudinal members
Load plan – running rails for the transversely movable ground floor Gate type
(GF) platforms
– aluminium gate type, extruded
– end rod with electronic safety strip
Platforms consisting of:
– lacquered type
Page 9 – Side members
Load plan – Cross members Colour options
– Platform base sections Shutter box, guide rails and gate type are avialabel with
– 1 wheel stop (on the right per parking space) the following colour options:
– Screws, small parts, etc. – RAL 9016 (traffic white)
– RAL 9006 (white aluminium)
Page 10
Lifting device for upper floor (UF) and lower floor (LF) platforms: – RAL 7016 (anthracite grey)
Technical
data – Hydraulic cylinder with solenoid valve
– Chain wheels Door actuation
– Chains Powered electrically by means of tube motor in the shaft.
– Limit switches For safety reasons the movement of the platforms is always
Page 11
– The platforms are suspended on four points and guided along made behind locked doors. Position sensing, i.e. “door open”
Electrical
the supports using plastic sliding bearings. and “door closed” is effected by electric signalers.
To be perfor-
med by the
customer Drive unit of transversely movable platforms on the ground floor (GF):
– Gear motor with chain wheel
Page 12
– Chains
Description
– Running and guide rollers (low-noise)
– Power supply via cable chain

Page 13
Description
TrendVario 4300 | Code number 585.29.210-014 | Version 07.2018 Page 13 of 13
Page 1
Description
Section
Car data Sliding doors:
Size Running rails
Page 2 Sliding door, dimensions: approx. 2500 mm x 2000 mm [8’-2’’ x 6’-7’’]) – The running gear of each doors consists of 2 twin-pair rolling
Height (width x height). gadgets, adjustable in height
dimensions Frame – The running rails of the doors are fixed to brackets or the
concrete lintel, or on a building-specific door suspension
– Frame construction with vertical centre stay bar made from using ceiling fittings
extruded aluminium profiles (anodized, layer thickness – The guide consists of 2 plastic rollers mounted to a base
Page 3 approx 20 μm [0.0008’’]). plate, which is dowelled to the floor
Sliding door – To open the doors a recessed grip is integrated in the aluminium – Running rails, ceiling fittings and guide roller base plate
width profile. are hot-dip galvanized
dimensions – A rubber lip is used for the finishing of the closing edge to the
building. Door actuation
Standard door panel Standard:
Page 4 – Manually, i.e. the door is opened and closed by hand
Perforated steel plate
Sliding door
width – Thickness 1 mm [0.04’’], RV 5/8, galvanized, layer thickness: Alternatively:
dimensions approx. 20 μm [0.0008’’] – Electric drive via electric motor mounted to the rail system
– Ventilation cross-section of the panel approx. 40% at the turning point of the sliding doors. The drive pinion
– Not suitable for outdoor garages engages into the chain mounted to the door.
Page 5
Alternative door panel For safety reasons the movement of the platforms is always made
Sliding door behind locked doors. Position sensing, i.e. “door open” and
width Perforated aluminium plate “door closed” is effected by electric signalers.
dimensions – Thickness 2 mm [0.08’’], RV 5/8 E6/EV1, anodized, layer thickness:
approx. 20 μm [0.0008’’] Separation (if necessary):
– Ventilation cross-section of the panel approx. 40% – Upon request
Page 6
Beaded steel plate Please note:
Roll door
width – Thickness 1mm, galvanized, layer thickness: approx. 20 μm Door panels (on the side, cover for running rails, etc.) and door
dimensions [0.0008’’]. suspensions are not included in the standard version but can be
– additional power coating, layer thickness: approx. 25 μm [0.001’’] delivered against surcharge as special equipment.
on the outside and approx. 12 μm [0.0005’’] on the inside
Page 7 – Colour options for the outside (building view):
Approach RAL 1015 (light ivory), RAL 3003 (ruby),
Free spaces RAL 5014 (pigeon blue), RAL 6005 (moss green),
Function RAL 7016 (anthracite grey), RAL 7035 (light grey),
RAL 7040 (window grey), RAL 8014 (sepia),
RAL 9006 (white aluminium), RAL 9016 (traffic white)
Page 8 – Inside of the gates in light grey
Plain aluminium sheet
Load plan

– Thickness 2 mm [0.08’’], E6/EV1, anodized, layer thickness:


approx. 20 μm [0.0008’’]
Wooden panelling
Page 9 – Nordic spruce in grade A
Load plan – vertical tongue and groove boards
– preimpregnated colourless
Laminated safety glass
– Laminated safety glass made from single pane safety glass 8/4 mm
Page 10 [0.3’’/0.15’’]
Technical Wire grating
data
– Mesh size 12 x 12 mm [0.5’’ x 0.5’’]
– Mesh size 40 x 40 mm [1.6’’ x 1.6’’] (for manual sliding gates only)

Page 11

We reserve the right to change this specification without further notice


Electrical
To be perfor-
med by the
customer KLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes,
procedures or standards in the fulfillment of their obligations other than those originally offered provided the customer derives no
Page 12
disadvantage from their so doing.
Description

Page 13
Description

S-ar putea să vă placă și