Sunteți pe pagina 1din 1

FRP Strengthening: VER 1.0 - Engr.

Juan
Validated by FYFE ASIA PTE LTD

Flexural Strengthening of Slabs and Rectangular Beams with


TYFO® Fibrwrap™ System
Date: February 04, 2020 Company: EC STRUCTURAL COMPOSITES INC.
Project Name: Retrofitting of UST Hospital Designed By: Heherson B. Juan, a.ASEP, ME-I
Project Location: UST Reference: Beam G-2

Code: American Concrete Institute, ACI 440.2R-08

FRP Manufacturer: FYFE ASIA PTE LTD


FRP Product: SCH-41
Laminate
carbon

Design Assumptions
Beam/Slab Width, b 500.0 mm
Depth to FRP ,df 750.0 mm
Effective depth, d 696.0 mm
Area of Tension Steel, As 4926.0 mm2
Modulus of Elasticity of Steel, Es 200000.0 Mpa Loadings and Corresponding Moments Calculations
Steel Strength, fy 414.0 Mpa Depth of neutral axis, c 212.394 mm
Required Moment, Mu -
Concrete Strength f'c 41.4 Mpa Environmental reduction factor,CE 0.95
Modulus of Elasticity of Concrete, Ec 30241.1 Mpa Modular ratio of elasticity, ns 6.61
Exposure Condition Interior β1 0.75
Tyfo FRP System Properties
Ultimate Tensile Strength, ffu 986.00 Mpa Parameters Check
Modulus of Elasticity of FRP laminate, Ef 95800 Mpa Results Design flexural Strength OK
FRP Width,Wf 450.0 mm
Existing Strength, ФMn 1171.09 Kn-m
Rupture strain, ε*fu 0.0100 Reinforcing steel stress check OK
FRP Thickness, tf 1.000 mm
No. of Layers, nf 2 Creep rupture limit of the FRP check OK
Strength with Tyfo FRP, ФMn 1529.88 Kn-m
FRP Area, Af 1350.0 mm2 at the service load level

Page 1 of 1