Prüfbericht - Nr.: Seite 1 von 20


ULR-TC568819400000573P
Test Report No.: Page 1 of 20
Auftraggeber: TMEIC INDUSTRIAL SYSTEMS INDIA PRIVATE LIMITED,
Client: POWER ELECTRONICS SYSTEMS DIVISION

Gegenstand der Prüfung: Utility Interactive Photovoltaic Inverter


Test item:
Bezeichnung: PVU-L0800ER Serien-Nr.: TM1951UPCSEU0022
Identification: PVU-L0840ER Serial No.: TM1951UPCSEU0021
PVU-L0880ER TM1951UPCSEU0020
PVU-L0920ER TM1951UPCSEU0019
Wareneingangs-Nr.: 166210200 Eingangsdatum: N/A
Receipt No.: Date of receipt:
Prüfort: Plot No 316, 2nd Phase Vasanthnarasapura
Testing location: KIADB Industrial Area, Yalladadlu Village, Kora Hobli,
Tumkur Taluk & District, Karnataka-572128, India.
Prüfgrundlage: Rated Output Efficiency measurement with Grid load as per customer
Test specification: requirement in accordance with table 1 of IEC 61683:1999.
Prüfergebnis: Refer section “ Summary of testing”
Test Result:
Prüflaboratorium: TÜV Rheinland (India) Pvt. Ltd.
Testing Laboratory: 27/B, 2nd Cross Road, Electronic City Phase I,
Bangalore - 560 100, Karnataka, India.
erstellt/compiled by: kontrolliert/reviewed by:

2019.12.23 Keerthi Prasad H / Engineer 2019.12.23 Manjunath K / Asst. Manager


Datum Name/Stellung Unterschrift Datum Name/Stellung Unterschrift
Date Name/Position Signature Date Name/Position Signature

Sonstiges/Other Aspects:

According to the customer’s requirement, the rated output efficiency measurement test (All 4 units) conducted
with grid load at client place as mentioned above and witnessed by us.

This report consists of 20 pages including the following attachments:


Attachment 1: Photo Document

Abkürzungen: P(ass) = entspricht Prüfgrundlage Abbreviations: P(ass) = passed


F(ail) = entspricht nicht Prüfgrundlage F(ail) = failed
N/A = nicht anwendbar N/A = not applicable
N/T = nicht getestet N/T = not tested
EUT = Equipment under test

Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht
auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.
This test report relates to the a. m. test sample. Without permission of the test centre, this test report is not permitted to
be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.
TUV Rheinland (India) Pvt.Ltd, Plot No.27/B, 2nd Cross, Electronic city, Industrial Area Phase I, Hosur Road Bangalore-560 100,India,
Tel: +91 80 4649811,Fax:+91 80 46498042 Mail: info@ind.tuv.com  Web: www.ind.tuv.com

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 2 of 20
Efficiency Testing

TEST REPORT
EFFICIENCY TESTING
Discipline……………………………...: Electronics
Group………………………………….: Miscellaneous

“The test results presented in this report relate only to the object tested and the statement of conformity is
based on measurement of uncertainty of 95% confidence level”
Report reference No ....................... : ULR-TC568819400000573P
Tested by
(printed name and signature) ........... : (see cover page) ……………………………………...
Approved by
(printed name and signature) ........... : (see cover page) ……………………………………...
Date of issue. ................................... : (see cover page)
Testing Laboratory Name .............. : TÜV Rheinland (India) Pvt. Ltd.
Address ............................................ : 27/B, 2nd Cross Road, Electronic City Phase I,
Bangalore - 560 100, Karnataka, India.
Applicant's Name ........................... : TMEIC INDUSTRIAL SYSTEMS INDIA PRIVATE LIMITED,
Address ............................................ : POWER ELECTRONICS SYSTEMS DIVISION
Plot No 316, 2nd Phase Vasanthnarasapura
KIADB Industrial Area, Yalladadlu Village, Kora Hobli,
Tumkur Taluk & District, Karnataka-572128, India.
Test specification ........................... :

Standard ........................................... : As per customer requirement in accordance with table 1 of


IEC 61683:1999
Test procedure ................................. : MS-0026235
Non-standard test method ................ : N/A
Test Report Form No...................... : TUVR_EFF
TRF originator .................................. : TUVR
Master TRF ...................................... : 2009.08.20
Copyright  2008 TUVR PSQ for Conformity Testing and Certification of Electrical Equipment. All rights
reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the TUVR is acknowledged as copyright
owner and source of the material. TUVR takes no responsibility for and will not assume liability for damages resulting from the reader’s
interpretation of the reproduced material due to its placement and context.

Test item description ........................ : Utility Interactive Photovoltaic Inverter

Trade Mark ………………………….. :

Manufacturer .................................... : TMEIC INDUSTRIAL SYSTEMS INDIA PRIVATE LIMITED,


POWER ELECTRONICS SYSTEMS DIVISION

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 3 of 20
Efficiency Testing

Model and/or type reference ............ : PVU-L0800ER


PVU-L0840ER
PVU-L0880ER
PVU-L0920ER
Serial number ................................... : TM1951UPCSEU0022
TM1951UPCSEU0021
TM1951UPCSEU0020
TM1951UPCSEU0019
Rating(s) ........................................... : Refer below Rating labels for more details

Copy of marking plate:

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 4 of 20
Efficiency Testing

General product information:

EUT is a Utility Interactive Photovoltaic Inverter.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 5 of 20
Efficiency Testing

Summary of testing:

This report covers Efficiency Tests (All 4 units) undertaken as per customer’s specifications with reference to
the listed standards.

Efficiency measurements performed with three input Voltages for all models.
1. Minimum rated input voltage.
2. Inverter's Nominal Voltage.
3. 90% of the inverter's maximum I/p voltage.

Test results:
Model: PVU-L0800ER (Refer table 1/1, 1/2 & 1/3 of this report.)
Model: PVU-L0840ER (Refer table 2/1, 2/2 & 2/3 of this report.)
Model: PVU-L0880ER (Refer table 3/1, 3/2 & 3/3 of this report.)
Model: PVU-L0920ER (Refer table 4/1, 4/2 & 4/3 of this report.)

All the EUT’s continues to work after test and no physical damages were observed.

Particulars: test item vs. test requirements


Operating condition ...................................... : Input : DC Power Source 1.67MW.
(Ref. Block diagram of 1.67MW Test bench on Page 20)
Output : Grid load with rated output voltage
Condition of the equipment at the time of
receipt ........................................................... : NA
Test case verdicts
Test case does not apply to the test object . : N/A
Test item does meet the requirement .......... : P(Pass)
Test item does not meet the requirement .... : F(Fail)
Testing
Date of receipt of test item ........................... : NA
Date(s) of performance of test ..................... : 2019.12.12
Attachments:
Attachment 1: Photo Document

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 6 of 20
Efficiency Testing

Test Results:

Table 1/1 (Minimum rated Input Voltage)


Model/Type PVU-L0800ER
Sl. No.: TM1951UPCSEU0022
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.55 9.66 19.76 24.85 29.90 50.15 75.38 100.38 _
DC Input Voltage (V) 877.40 877.30 877.00 876.90 876.80 876.30 875.70 875.10 _
DC Input Current (A) 44.45 91.53 183.58 230.36 276.23 463.31 696.47 929.72 _
DC Input Power (kW) 39.00 80.30 161.00 202.00 242.20 406.00 609.90 813.60 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.01 _
Voltage (V) Urms-E1 608.60 608.85 609.49 609.57 609.86 610.61 611.34 611.82 _
Voltage (V)Urms-E2 605.96 606.01 606.01 606.10 606.11 606.35 606.33 606.35 _
Voltage (V) Urms-E3 604.60 604.81 605.01 605.27 605.39 605.83 606.61 607.21 _
Current (A) Irms-E1 37.60 76.90 152.80 191.50 230.70 384.60 575.70 767.70 _
Current (A)Irms-E2 34.50 73.10 149.60 188.10 226.00 379.60 570.20 761.40 _
Current (A) Irms-E3 36.20 74.00 150.60 189.00 226.80 380.00 572.90 763.80 _
Output

Power Factor 0.960 0.986 0.996 0.998 0.999 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.45 1.56 1.32 1.30 1.25 1.23 1.30 1.35 _
THD (V in %)Uthd-E2 1.23 1.50 1.12 1.10 1.01 0.99 1.15 1.27 _
THD (V in %)Uthd-E3 1.46 1.36 1.46 1.40 1.38 1.42 1.40 1.50 _
THD (I in %)Ithd-E1 17.89 10.34 8.90 6.84 5.32 2.98 2.31 1.96 _
THD (I in %)Ithd-E2 17.56 10.34 6.29 4.89 3.18 2.45 2.02 1.77 _
THD (I in %)Ithd-E3 17.78 10.45 8.20 5.85 4.62 2.59 2.04 1.79 _
Power (kW) 36.40 77.30 158.10 198.80 239.20 401.20 603.00 803.00 _
Power (kVA) 37.90 78.40 158.70 199.30 239.60 401.40 603.50 805.50 _

Rated Output Efficiency


93.33 96.26 98.20 98.42 98.76 98.82 98.87 98.70 _
(%)

European Efficiency (%) _


98.39
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 7 of 20
Efficiency Testing

Test Results:

Table 1/2 (Inverter's Nominal Voltage)


Model/Type PVU-L0800ER
Sl. No.: TM1951UPCSEU0022
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.08 9.16 19.28 24.31 29.36 49.58 74.86 100.10 _
DC Input Voltage (V) 962.60 962.40 962.20 962.10 962.00 961.50 960.90 960.40 _
DC Input Current (A) 36.36 78.97 163.06 205.59 247.40 417.78 631.60 845.48 _
DC Input Power (kW) 35.00 76.00 156.90 197.80 238.00 401.70 606.90 812.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.01 _
Voltage (V) Urms-E1 608.88 609.20 609.36 609.52 609.81 610.58 611.21 611.80 _
Voltage (V)Urms-E2 605.76 605.88 606.24 606.10 606.20 606.27 606.41 606.35 _
Voltage (V) Urms-E3 604.45 604.55 604.84 605.24 605.30 605.87 606.69 607.24 _
Current (A) Irms-E1 33.40 72.60 149.20 187.20 225.80 379.70 571.60 763.60 _
Current (A)Irms-E2 31.30 69.40 145.70 183.80 222.20 375.30 566.50 757.20 _
Current (A) Irms-E3 32.10 70.30 146.50 184.90 222.80 375.90 568.30 759.30 _
Output

Power Factor 0.961 0.986 0.997 0.999 0.999 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 0.70 0.96 1.26 1.14 1.07 1.05 1.11 1.23 _
THD (V in %)Uthd-E2 1.35 1.25 0.98 0.93 0.84 0.81 0.88 1.00 _
THD (V in %)Uthd-E3 0.87 1.12 1.27 1.12 1.01 0.98 1.14 1.37 _
THD (I in %)Ithd-E1 14.44 10.74 7.13 4.58 3.39 1.89 1.71 1.57 _
THD (I in %)Ithd-E2 18.82 11.45 5.51 3.05 3.10 1.54 1.14 1.13 _
THD (I in %)Ithd-E3 18.52 10.96 7.56 4.38 3.01 1.63 1.37 1.35 _
Power (kW) 32.60 73.30 154.20 194.50 234.90 396.60 598.90 800.80 _
Power (kVA) 33.90 74.30 154.70 194.80 235.10 396.70 599.10 801.00 _

Rated Output Efficiency


93.15 96.45 98.28 98.33 98.70 98.73 98.68 98.62 _
(%)

European Efficiency (%) _


98.34
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 8 of 20
Efficiency Testing

Test Results:

Table 1/3 (90% of the Inverter's maximum Input voltage)


Model/Type PVU-L0800ER
Sl. No.: TM1951UPCSEU0022
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 5.71 10.94 21.11 26.24 31.25 51.30 76.44 100.36 _
DC Input Voltage (V) 1201.70 1201.60 1201.40 1201.30 1201.20 1200.80 1200.40 1200.00 _
DC Input Current (A) 40.94 75.57 143.75 177.89 211.62 346.02 516.16 679.17 _
DC Input Power (kW) 49.20 90.80 172.70 213.70 254.20 415.50 619.60 815.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.01 _
Voltage (V) Urms-E1 608.74 609.12 609.43 609.63 609.63 610.68 611.26 611.75 _
Voltage (V)Urms-E2 605.77 605.74 605.88 606.00 606.30 606.40 606.27 606.19 _
Voltage (V) Urms-E3 604.85 605.03 605.31 605.41 605.49 605.66 606.59 607.28 _
Current (A) Irms-E1 45.70 84.70 162.40 201.10 239.60 392.80 583.90 775.10 _
Current (A)Irms-E2 43.90 82.90 159.20 197.40 235.90 388.50 578.10 768.50 _
Current (A) Irms-E3 44.80 83.20 160.40 198.30 236.40 389.20 580.50 771.30 _
Output

Power Factor 0.972 0.996 0.998 0.999 0.999 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.07 1.22 1.35 1.27 1.23 1.07 1.27 1.39 _
THD (V in %)Uthd-E2 1.86 1.84 1.13 1.07 1.06 0.90 1.02 1.17 _
THD (V in %)Uthd-E3 1.12 1.33 1.37 1.27 1.18 1.04 1.31 1.54 _
THD (I in %)Ithd-E1 23.94 16.16 4.76 3.60 2.82 1.47 1.68 1.54 _
THD (I in %)Ithd-E2 19.56 17.12 3.46 3.03 2.60 1.46 1.09 1.07 _
THD (I in %)Ithd-E3 23.27 16.09 3.82 3.00 2.07 1.14 1.31 1.24 _
Power (kW) 45.70 87.50 168.89 209.90 250.00 410.40 611.50 802.90 _
Power (kVA) 47.00 87.90 168.90 209.10 249.50 410.60 611.70 803.10 _

Rated Output Efficiency


92.89 96.37 97.79 98.22 98.35 98.77 98.69 98.52 _
(%)

European Efficiency (%) _


98.23
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 9 of 20
Efficiency Testing

Test Results:

Table 2/1 (Minimum rated Input Voltage)


Model/Type PVU-L0840ER
Sl. No.: TM1951UPCSEU0021
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.49 9.58 19.69 24.75 29.81 50.00 75.29 100.01 _
DC Input Voltage (V) 915.80 915.70 915.30 915.20 915.10 915.60 915.90 915.30 _
DC Input Current (A) 43.90 90.86 184.53 231.21 278.00 464.61 698.32 929.74 _
DC Input Power (kW) 40.20 83.20 168.90 211.60 254.40 425.40 639.59 850.99 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 631.75 632.31 633.21 633.67 634.11 635.55 637.13 638.18 _
Voltage (V)Urms-E2 632.36 632.75 633.84 634.31 634.65 636.19 637.74 638.88 _
Voltage (V) Urms-E3 631.25 631.66 632.53 632.88 633.32 634.63 635.62 636.22 _
Current (A) Irms-E1 36.80 74.40 151.70 191.20 229.40 382.60 574.80 760.00 _
Current (A)Irms-E2 33.90 72.30 149.90 188.10 226.50 380.70 571.90 757.40 _
Current (A) Irms-E3 35.20 74.50 151.20 189.30 228.50 382.50 573.90 759.00 _
Output

Power Factor 0.976 0.997 0.999 0.999 1.000 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.45 0.56 0.57 0.60 0.58 0.34 0.32 0.63 _
THD (V in %)Uthd-E2 1.23 0.42 0.62 0.59 0.55 0.33 0.45 0.74 _
THD (V in %)Uthd-E3 1.46 0.35 0.69 0.73 0.66 0.33 0.24 0.59 _
THD (I in %)Ithd-E1 17.89 5.95 3.14 2.75 2.27 1.21 1.11 1.34 _
THD (I in %)Ithd-E2 17.56 6.02 2.88 2.36 1.97 1.31 1.19 1.46 _
THD (I in %)Ithd-E3 17.78 5.40 3.05 2.42 1.89 1.34 1.44 1.38 _
Power (kW) 37.70 80.47 165.42 207.88 250.40 420.01 632.47 840.10 _
Power (kVA) 38.62 80.73 165.57 208.00 250.55 420.39 632.62 840.22 _

Rated Output Efficiency


93.78 96.72 97.94 98.24 98.43 98.73 98.89 98.72 __
(%)

European Efficiency (%) _


98.33
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 10 of 20
Efficiency Testing

Test Results:

Table 2/2 (Inverter's Nominal Voltage)


Model/Type PVU-L0840ER
Sl. No.: TM1951UPCSEU0021
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.17 9.26 19.39 24.47 29.51 49.69 74.94 99.97 _
DC Input Voltage (V) 960.90 960.70 960.40 960.30 960.20 959.60 959.00 958.40 _
DC Input Current (A) 38.82 83.79 172.74 217.85 262.13 441.12 664.34 886.89 _
DC Input Power (kW) 37.30 80.50 165.90 209.20 251.70 423.30 637.10 850.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 631.61 632.27 633.16 633.62 633.98 635.57 637.10 638.03 _
Voltage (V)Urms-E2 632.40 632.82 633.83 634.29 634.69 636.17 637.82 638.94 _
Voltage (V) Urms-E3 631.25 631.57 632.56 632.83 633.33 634.60 635.62 636.28 _
Current (A) Irms-E1 33.10 72.50 149.00 188.30 226.20 380.20 571.70 758.40 _
Current (A)Irms-E2 32.30 69.70 147.60 186.10 224.50 378.00 570.00 756.70 _
Current (A) Irms-E3 32.70 71.40 149.10 187.40 226.50 379.90 570.60 757.50 _
Output

Power Factor 0.977 0.996 1.000 1.000 1.000 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 0.70 0.78 0.43 0.36 0.35 0.49 0.40 0.43 _
THD (V in %)Uthd-E2 1.35 0.62 0.45 0.44 0.37 0.37 0.30 0.40 _
THD (V in %)Uthd-E3 0.87 0.56 0.50 0.47 0.39 0.34 0.40 0.22 _
THD (I in %)Ithd-E1 14.44 7.38 2.53 1.88 1.51 1.44 1.11 0.78 _
THD (I in %)Ithd-E2 18.82 8.60 2.58 2.13 1.42 1.53 0.91 0.87 _
THD (I in %)Ithd-E3 18.52 7.07 3.01 2.45 1.55 1.32 1.04 0.42 _
Power (kW) 34.99 77.79 162.89 205.54 247.87 417.43 629.50 839.75 _
Power (kVA) 35.80 77.98 162.96 205.50 247.88 417.51 629.57 839.79 _

Rated Output Efficiency


93.81 96.63 98.19 98.25 98.48 98.61 98.81 98.79 _
(%)

European Efficiency (%) _


98.32
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 11 of 20
Efficiency Testing

Test Results:

Table 2/3 (90% of the Inverter's maximum Input voltage)


Model/Type PVU-L0840ER
Sl. No.: TM1951UPCSEU0021
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 5.39 10.45 20.58 25.67 30.79 50.89 75.92 101.07 _
DC Input Voltage (V) 1201.70 1201.50 1201.30 1201.20 1201.10 1200.80 1200.30 1199.80 _
DC Input Current (A) 40.44 75.82 146.59 182.32 218.30 360.51 538.87 717.95 _
DC Input Power (kW) 48.60 91.10 176.10 219.00 262.20 432.90 646.80 861.40 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 642.44 642.58 642.97 643.13 643.23 643.98 644.82 645.55 _
Voltage (V)Urms-E2 637.33 637.26 637.41 637.46 637.48 637.78 637.61 637.44 _
Voltage (V) Urms-E3 633.64 634.13 634.25 634.39 634.64 634.88 635.69 636.41 _
Current (A) Irms-E1 45.00 82.60 161.20 199.40 237.50 390.70 581.50 773.00 _
Current (A)Irms-E2 41.00 80.00 154.80 193.00 231.20 383.30 573.40 763.70 _
Current (A) Irms-E3 42.70 79.90 155.80 193.70 231.80 384.20 575.00 765.40 _
Output

Power Factor 0.957 0.982 0.991 0.994 0.996 0.998 0.999 0.999 _
THD (V in %)Uthd-E1 1.07 1.22 1.35 1.27 1.23 1.07 1.27 1.39 _
THD (V in %)Uthd-E2 1.86 1.84 1.13 1.07 1.06 0.90 1.02 1.17 _
THD (V in %)Uthd-E3 1.12 1.33 1.37 1.27 1.18 1.04 1.31 1.54 _
THD (I in %)Ithd-E1 23.94 16.16 4.76 3.60 2.82 1.47 1.68 1.54 _
THD (I in %)Ithd-E2 19.56 17.12 3.46 3.03 2.60 1.46 1.09 1.07 _
THD (I in %)Ithd-E3 23.27 16.09 3.82 3.00 2.07 1.14 1.31 1.24 _
Power (kW) 45.30 87.79 172.90 215.59 258.60 427.50 637.70 849.00 _
Power (kVA) 47.40 89.30 173.90 216.00 258.20 427.20 638.60 850.30 _

Rated Output Efficiency


93.21 96.37 98.18 98.44 98.63 98.75 98.59 98.56 _
(%)

European Efficiency (%) _


98.32
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 12 of 20
Efficiency Testing

Test Results:

Table 3/1 (Minimum rated Input Voltage)


Model/Type PVU-L0880ER
Sl. No.: TM1951UPCSEU0020
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.52 9.61 19.85 24.88 29.95 50.08 75.23 100.00 _
DC Input Voltage (V) 961.60 961.50 961.20 961.10 961.00 960.50 959.80 959.20 _
DC Input Current (A) 44.30 91.11 184.46 231.09 277.73 464.34 698.58 929.94 _
DC Input Power (kW) 42.60 87.60 177.30 222.10 266.90 446.00 670.50 892.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 663.10 663.50 663.80 664.00 664.30 665.00 665.80 666.50 _
Voltage (V)Urms-E2 662.30 662.30 662.70 662.80 662.90 663.00 662.90 663.00 _
Voltage (V) Urms-E3 662.30 662.50 662.90 663.00 663.10 663.80 664.70 665.10 _
Current (A) Irms-E1 35.80 74.70 152.40 190.90 230.00 384.60 577.10 766.20 _
Current (A)Irms-E2 34.60 72.80 150.60 189.10 227.50 381.90 574.70 763.70 _
Current (A) Irms-E3 36.20 74.10 151.40 189.80 228.50 383.30 576.60 766.30 _
Output

Power Factor 0.971 0.995 0.998 0.999 0.999 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.45 1.56 0.33 0.35 0.34 0.35 0.52 0.74 _
THD (V in %)Uthd-E2 1.23 1.50 0.47 0.49 0.50 0.48 0.58 0.74 _
THD (V in %)Uthd-E3 1.46 1.36 0.32 0.43 0.39 0.40 0.57 0.75 _
THD (I in %)Ithd-E1 17.89 10.34 4.64 3.02 2.70 1.40 1.24 1.40 _
THD (I in %)Ithd-E2 17.56 10.34 4.78 3.31 2.74 1.30 1.26 1.39 _
THD (I in %)Ithd-E3 17.78 10.45 4.50 3.10 2.73 1.48 1.27 1.28 _
Power (kW) 39.80 84.60 174.70 218.90 263.60 440.70 662.00 880.00 _
Power (kVA) 40.80 84.80 174.00 218.20 262.80 440.80 663.10 881.40 _

Rated Output Efficiency


93.43 96.58 98.53 98.56 98.76 98.81 98.73 98.65 _
(%)

European Efficiency (%) _


98.44
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 13 of 20
Efficiency Testing

Test Results:

Table 3/2 (Inverter's Nominal Voltage)


Model/Type PVU-L0880ER
Sl. No.: TM1951UPCSEU0020
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.16 9.27 19.43 24.41 29.53 49.76 74.92 99.82 _
DC Input Voltage (V) 1022.60 1022.40 1022.20 1022.10 1022.00 1021.50 1020.90 1020.40 _
DC Input Current (A) 38.43 82.36 170.32 214.07 257.93 433.77 653.93 872.11 _
DC Input Power (kW) 39.30 84.20 174.10 218.80 263.60 443.10 667.60 889.90 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 663.10 663.50 663.80 664.00 664.30 664.90 665.70 666.50 _
Voltage (V)Urms-E2 662.30 662.30 662.70 662.70 662.80 663.10 663.10 663.00 _
Voltage (V) Urms-E3 662.30 662.50 662.80 663.00 663.10 663.80 664.70 665.10 _
Current (A) Irms-E1 32.30 71.60 148.80 187.40 226.20 381.20 573.90 764.20 _
Current (A)Irms-E2 31.20 70.00 147.30 185.90 224.50 378.70 571.30 761.20 _
Current (A) Irms-E3 32.00 71.10 148.20 186.90 225.50 380.00 573.50 763.60 _
Output

Power Factor 0.989 0.994 0.999 1.000 1.000 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 0.70 0.96 0.48 0.46 0.43 0.27 0.40 0.47 _
THD (V in %)Uthd-E2 1.35 1.25 0.55 0.54 0.48 0.38 0.44 0.43 _
THD (V in %)Uthd-E3 0.87 1.12 0.42 0.41 0.40 0.28 0.44 0.51 _
THD (I in %)Ithd-E1 14.44 10.74 3.39 2.15 1.36 0.64 0.63 0.98 _
THD (I in %)Ithd-E2 18.82 11.45 3.35 2.36 1.64 0.68 0.64 0.82 _
THD (I in %)Ithd-E3 18.52 10.96 3.38 2.10 1.35 0.62 0.76 0.87 _
Power (kW) 36.60 81.59 170.99 214.80 259.90 437.90 659.30 878.40 _
Power (kVA) 36.50 81.40 170.10 214.50 259.00 437.00 659.40 878.70 _

Rated Output Efficiency


93.13 96.90 98.21 98.17 98.60 98.83 98.76 98.71 _
(%)

European Efficiency (%) _


98.41
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 14 of 20
Efficiency Testing

Test Results:

Table 3/3 (90% of the Inverter's maximum Input voltage)


Model/Type PVU-L0880ER
Sl. No.: TM1951UPCSEU0020
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.99 10.09 20.22 25.22 30.27 50.33 75.57 100.26 _
DC Input Voltage (V) 1201.80 1201.70 1201.40 1201.30 1201.20 1200.80 1200.30 1199.80 _
DC Input Current (A) 39.19 76.81 150.99 188.21 225.36 374.42 560.86 745.37 _
DC Input Power (kW) 47.10 92.30 181.40 226.10 270.70 449.60 673.20 894.30 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 663.00 663.40 663.80 664.00 664.20 664.80 665.70 666.40 _
Voltage (V)Urms-E2 662.50 662.40 662.60 662.60 662.70 663.00 663.20 662.70 _
Voltage (V) Urms-E3 662.30 662.60 662.90 663.10 663.20 663.90 664.40 665.10 _
Current (A) Irms-E1 39.20 77.90 154.80 193.40 232.00 385.70 577.80 767.60 _
Current (A)Irms-E2 38.10 76.70 153.10 191.70 229.90 383.90 575.70 764.50 _
Current (A) Irms-E3 38.60 77.30 154.30 192.50 231.30 385.20 577.60 767.10 _
Output

Power Factor 0.991 0.996 0.999 1.000 1.000 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.07 1.22 0.59 0.49 0.42 0.54 0.70 0.79 _
THD (V in %)Uthd-E2 1.86 1.84 0.61 0.53 0.46 0.54 0.72 0.76 _
THD (V in %)Uthd-E3 1.12 1.33 0.58 0.46 0.41 0.54 0.67 0.79 _
THD (I in %)Ithd-E1 23.94 16.16 2.55 1.71 1.48 0.70 0.92 1.11 _
THD (I in %)Ithd-E2 19.56 17.12 2.77 2.04 1.95 0.78 0.90 0.97 _
THD (I in %)Ithd-E3 23.27 16.09 2.57 1.64 1.42 0.77 0.93 1.03 _
Power (kW) 43.90 88.80 177.90 221.90 266.40 442.90 665.00 882.30 _
Power (kVA) 44.30 88.70 177.00 221.20 265.50 442.60 664.10 882.40 _

Rated Output Efficiency


93.21 96.21 98.07 98.14 98.41 98.51 98.78 98.66 _
(%)

European Efficiency (%) _


98.18
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 15 of 20
Efficiency Testing

Test Results:

Table 4/1 (Minimum rated Input Voltage)


Model/Type PVU-L0920ER
Sl. No.: TM1951UPCSEU0019
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.55 9.56 19.71 24.77 29.86 50.40 75.59 99.96 _
DC Input Voltage (V) 1006.50 1006.40 1006.10 1006.00 1005.90 1005.40 1004.80 1004.20 _

DC Input Current (A) 44.01 90.72 183.68 230.32 276.77 466.58 699.54 927.11 _
DC Input Power (kW) 44.30 91.30 184.80 231.70 278.40 469.10 702.90 931.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _

Voltage (V) Urms-E1 693.80 693.90 694.70 694.80 694.90 695.80 696.70 697.30 _
Voltage (V)Urms-E2 692.50 692.60 692.90 693.00 692.90 693.20 693.10 693.10 _
Voltage (V) Urms-E3 692.20 692.50 692.40 692.60 693.00 693.70 694.50 695.10 _
Current (A) Irms-E1 36.00 74.80 152.90 190.90 229.90 387.20 579.40 764.70 _
Current (A)Irms-E2 33.90 72.90 149.80 188.70 227.00 384.10 576.50 761.70 _
Current (A) Irms-E3 35.50 74.00 150.50 189.70 228.60 385.40 578.40 764.60 _
_
Output

Power Factor 0.973 0.991 0.999 0.999 0.999 1.000 1.000 1.000
THD (V in %)Uthd-E1 1.45 1.56 0.38 0.34 0.38 0.49 0.64 0.80 _

THD (V in %)Uthd-E2 1.23 1.50 0.52 0.54 0.55 0.52 0.66 0.86 _

THD (V in %)Uthd-E3 1.46 1.36 0.45 0.42 0.41 0.56 0.69 0.86 _
THD (I in %)Ithd-E1 17.89 10.34 5.82 4.15 3.18 1.75 1.39 1.40 _
THD (I in %)Ithd-E2 17.56 10.34 4.60 3.35 3.00 1.35 1.37 1.49 _

THD (I in %)Ithd-E3 17.78 10.45 5.36 3.97 3.10 1.47 1.22 1.31 _
Power (kW) 41.90 87.99 181.30 227.90 274.70 463.70 695.40 919.60 _
Power (kVA) 42.20 88.70 181.40 227.90 274.50 463.60 695.70 919.50 _

Rated Output Efficiency


94.58 96.38 98.11 98.36 98.67 98.85 98.93 98.78 _
(%)

European Efficiency (%) _


98.44
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 16 of 20
Efficiency Testing

Test Results:

Table 4/2 (Inverter's Nominal Voltage)


Model/Type PVU-L0920ER
Sl. No.: TM1951UPCSEU0019
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.13 9.19 19.33 24.45 29.53 49.65 74.93 99.58 _

DC Input Voltage (V) 1062.60 1062.50 1062.30 1062.10 1062.10 1061.60 1061.00 1060.50 _

DC Input Current (A) 38.58 82.73 171.14 215.05 259.11 436.13 657.59 874.40 _

DC Input Power (kW) 41.00 87.90 181.80 228.40 275.20 463.00 697.70 927.30 _

Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _

Voltage (V) Urms-E1 693.80 694.00 694.60 694.80 695.00 695.70 696.80 697.30 _

Voltage (V)Urms-E2 692.30 692.50 692.80 692.90 693.00 693.30 693.20 693.00 _

Voltage (V) Urms-E3 692.30 692.50 692.50 692.70 692.90 693.60 694.40 695.20 _

Current (A) Irms-E1 32.80 72.20 149.40 187.70 226.50 381.40 574.80 762.80 _

Current (A)Irms-E2 31.20 69.80 147.00 185.70 224.50 378.70 571.00 758.90 _

Current (A) Irms-E3 32.40 71.10 148.10 186.80 225.30 379.80 573.10 761.90 _
_
Output

Power Factor 0.980 0.991 0.999 0.999 0.999 1.000 1.000 1.000
THD (V in %)Uthd-E1 0.70 0.96 0.48 0.42 0.43 0.41 0.55 0.62 _

THD (V in %)Uthd-E2 1.35 1.25 0.63 0.58 0.54 0.40 0.51 0.61 _

THD (V in %)Uthd-E3 0.87 1.12 0.43 0.40 0.36 0.42 0.59 0.74 _

THD (I in %)Ithd-E1 14.44 10.74 4.31 2.57 2.03 0.86 0.95 1.12 _

THD (I in %)Ithd-E2 18.82 11.45 3.89 2.58 1.95 0.82 0.75 0.86 _

THD (I in %)Ithd-E3 18.52 10.96 4.40 2.83 2.05 0.75 0.79 1.00 _

Power (kW) 38.00 84.59 177.79 224.90 271.70 456.80 689.40 916.10 _

Power (kVA) 38.60 85.20 177.90 224.30 270.90 456.90 689.50 916.50 _

Rated Output Efficiency


92.68 96.23 97.79 98.47 98.73 98.66 98.81 98.79 _
(%)

European Efficiency (%) _


98.26
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 17 of 20
Efficiency Testing

Test Results:

Table 4/3 (90% of the Inverter's maximum Input voltage)


Model/Type PVU-L0920ER
Sl. No.: TM1951UPCSEU0019
Load type: Grid load
Load (%) 5 10 20 25 30 50 75 100 120*
Actual load (%) 4.55 9.51 19.55 24.66 29.66 49.74 74.89 99.57 _
DC Input Voltage (V) 1201.80 1201.60 1201.30 1201.30 1201.20 1200.80 1200.20 1199.70 _
DC Input Current (A) 37.11 76.07 153.50 192.29 231.02 386.58 582.65 775.19 _
DC Input Power (kW) 44.60 91.40 184.40 231.00 277.50 464.20 699.30 930.00 _
Frequency(Hz) - E1 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 _
Voltage (V) Urms-E1 693.90 694.10 694.60 694.70 695.00 695.60 696.70 697.30 _
Voltage (V)Urms-E2 692.30 692.60 692.70 692.80 693.10 693.50 693.00 692.90 _
Voltage (V) Urms-E3 692.20 692.30 692.70 692.90 692.80 693.30 694.40 695.00 _
Current (A) Irms-E1 35.50 74.20 150.70 189.30 227.90 382.40 575.10 763.30 _
Current (A)Irms-E2 33.20 72.50 148.60 186.90 225.50 379.20 571.50 759.30 _
Current (A) Irms-E3 35.20 73.30 150.10 188.20 226.40 380.30 573.90 761.90 _
Output

Power Factor 0.987 0.993 0.999 1.000 1.000 1.000 1.000 1.000 _
THD (V in %)Uthd-E1 1.07 1.22 0.63 0.56 0.47 0.51 0.73 0.81 _
THD (V in %)Uthd-E2 1.86 1.84 0.74 0.63 0.52 0.54 0.67 0.79 _
THD (V in %)Uthd-E3 1.12 1.33 0.68 0.51 0.51 0.51 0.80 0.91 _
THD (I in %)Ithd-E1 23.94 16.16 3.95 2.19 1.55 0.79 1.19 1.28 _
THD (I in %)Ithd-E2 19.56 17.12 3.75 2.38 1.91 0.90 0.92 1.03 _
THD (I in %)Ithd-E3 23.27 16.09 3.96 2.27 1.58 0.82 1.08 1.15 _
Power (kW) 41.90 87.49 179.90 226.90 272.90 457.60 689.00 916.00 _
Power (kVA) 41.50 88.00 179.80 226.00 272.30 457.70 690.00 916.80 _

Rated Output Efficiency


93.95 95.72 97.56 98.23 98.34 98.58 98.53 98.49 _
(%)

European Efficiency (%) _


98.10
Note:
The above readings are taken at an ambient temperature of 25.0°C +/- 2°C
*120 % load was not performed due to over load protection provided in EUT.

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 18 of 20
Efficiency Testing

Attachment-1: Photo Document

Overall View

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 19 of 20
Efficiency Testing

Front View
Rear View

Doc. No.: MS-0026235.


Annex 2 TRF originator: TÜV Rheinland Group
Report No.:ULR-TC568819400000573P Page 20 of 20
Efficiency Testing

Block diagram of 1.67MW Test bench

EQUIPMENT’S LIST:

Equipment Calibration Calibration


SL.No Model SL. NO
Description on due
Power Analyzer -
1 WT1806E C3TD18064E 05/12/2019 04/12/2020
YOKOGAWA
Oscilloscope -
2 DL850E 91T506402 05/12/2019 04/12/2020
YOKOGAWA
DC Power Supply -
3 1.67MW - NA NA
TMEIC
Current Transducer –
4 ITZ- 5000-140 1171970001 05/12/2019 04/12/2020
1 LEM
Current Transducer –
5 ITZ-5000-140 1171370003 05/12/2019 04/12/2020
2 LEM
Current Transducer -
6 ITZ- 5000-140 1170470005 05/12/2019 04/12/2020
3 LEM
AC/DC Clamp Meter -
8 CM4374 180532169 10/01/2019 09/01/2020
Hioki
Digital Hygrometer –
9 608H1 DTH-01 07/03/2019 06/03/2020
Testo
Supplementary Information:

* End of Report *