Sunteți pe pagina 1din 5

Open Ended Lab

Objective:
Using Aspen Hysys, determine the percentage of naphtha cut of any commercial crude and vapor
fraction that will be obtained at 100°C.

Description:
The petroleum characterization method in HYSYS converts laboratory analysis of condensates,
crude oil, petroleum cuts and coal-tar liquids into a series of discrete hypothetical components.
These petroleum hypo components provide the basis for the property package to predict the
remaining thermodynamic and transport properties necessary for fluid modeling.

HYSYS produces a complete set of physical and critical properties for the petroleum hypo
components with a minimal amount of information. However, the more information you supply
about the field, the more accurate these properties will be, and better HYSYS will predict the
fluid’s actual behavior.

Procedure:
 First step in simulating this problem is to select components and fluid package. For
this, we first click on properties tab and then select required variables similarly select the
suitable fluid package.
 Then for assay we tap oil manager and select input assay and add an assay, then change
the bulk properties to used. After this, select our assay data type , selecting the
dependent and independent properties that are given in the data and put these given
values accordingly. Also, the light end is changed to input composition.
 Next step is calculating the assay, by simply tapping calculate.
 Then we add our blend to output blend and set the number of cuts.
 Before tapping output blend, we tap install oil and give stream name so that we can
simulate this.
 Then we can determine the percentage of naphtha cut by tapping on distribution plot.
SIMULATION DATA
1
Company Name Not Case Name:open ended lab.hsc
2
Available
3 Unit Set: UserField3b
Bedford, MA
4 USA Date/Time:Mon Jan 20 00:45:28 2020
5
6
7 Assay: Assay-1
8
9 INPUT DATA
10
11 Data Type: TBP
12
13 Assay Basis: Liquid Volume TBP Distillation Conditions: Atmospheric
14 Light Ends Status : Input Composition
15
16 Percentage of Light Ends in Assay: 6 * Light Ends Basis: Liquid Volume %
17 Light Ends Composition Table
18
19 Light Ends Composition
20 Methane 6.500e-003 *
21 Ethane 2.250e-002 *
22 Propane 0.3200 *
23 i-Butane 0.2400 *
24 n-Butane 1.750 *
25 i-Pentane 1.650 *
26 n-Pentane 2.250 *
27 H2O 0.0000 *
28 Bulk Properties: Used
29
30 Molecular Weight --- Viscosity1 Temperature (F) 100.0 *
31 Mass Density (lb/ft3) --- Viscosity1 (cP) ---
32 Watson Uopk --- Viscosity2 Temperature (F) 210.0 *
33 Viscosity2 (cP) ---
34 Distillation Table
35
36 Assay Percent Temperature (F)
37 0* 10.40 *
38 4* 89.60 *
39 9* 165.2 *
40 14 * 240.8 *
41 20 * 309.2 *
42 30 * 435.2 *
43 40 * 523.4 *
44 50 * 620.6 *
45 60 * 739.4 *
46 70 * 842.0 *
47 76 * 914.0 *
48 80 * 960.8 *
49 Input Data Status
50
51 Molecular Weight : Not Used Density : Not Used Viscosity : Not Used
52 CALCULATION DEFAULTS
53
54 Conversion Methods
55
56 D86-TBP Interconversion: API 1994 D2887-TBP Conversion: API 1994 Direct
57 Corrections for Raw Lab Data
58
59 Apply ASTM D86 API Cracking Apply Lab Barometric Pressure Lab Barometric Pressure: 14.70 psia
Correction: No Correction: No
60 Extrapolation Methods
61
62 Distillation: Probability Molecular Weight: Least Squares

63 Density: Least Squares Viscosity 1: Least Squares Viscosity 2: Least Squares


64 USER CURVES
65
66 User Property Table Type Bulk Value Extrap Method Apply To
67

68

69 Aspen Technology Inc. Aspen HYSYS Version 10 Page 1 of 2


Result and discussion