APPROVAL OF ELECTRICAL APPARATUS & CABLES UNDER REGULATION
75(2) OF THE OIL MINES REGULATIONS, 1984
The list of approved flameproof electrical motor is not exhaustive and subject to verification of the approval documents.
Sl. Description of motors Name of Approval Valid
No. Manufacturer no. upto (M/S) C1 Flameproof fan cooled squirrel cage M/S Crompton 122 of 1976 30.09.2009 induction motor rated at 18.5 Greaves Limited KW(25 HP), 381/440 V, 3 phase, 50 A-6/2, MIDC Hz in frame size-E 180L in cast iron Ahmednagar-414 construction with detachable 111 (Maharashtra). terminal box fitted with cable sealing box conforming to IS:2148- 2004 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C2 Flameproof squirrel cage induction M/S Crompton 78 of 1974 29.03.2010 motor rated at 37 KW(50 HP), Greaves Limited 381/440 V, 3 phase, 1500 RPM, 50 A-6/2, MIDC Hz in frame size-E 225S conforming Ahmednagar-414 to IS:2148-2004 and IS:13346-2004 111 (Maharashtra). for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C3 Flameproof squirrel cage induction M/S Crompton 79 of 1974 07.01.2010 motor rated at 55 KW(75 HP), Greaves Limited 381/440 V, 50 Hz, 3000 RPM in A-6/2, MIDC frame size E 250 M for use in Zone Ahmednagar-414 1 & Zone 2 hazardous areas of Oil 111 (Maharashtra). Mines. C4 Flameproof squirrel cage induction M/S Crompton 80 of 1974 07.01.2010 motor rated at 45 KW(60 HP), Greaves Limited 381/440 V, 3 phase, 3000 RPM, 50 A-6/2, MIDC Hz in frame size-E 225 M Ahmednagar-414 conforming to IS:2148-2004 and 111 (Maharashtra). IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C5 Flameproof squirrel cage induction M/S Crompton 103 of 1975 07.05.2010 motor rated at 5.5 KW (7.5 HP), Greaves Limited 381/440 V, 3 phase, 50 Hz, 3000 A-6/2, MIDC RPM synchronous continuous duty Ahmednagar-414 with class ‘F’ insulation in frame 111 (Maharashtra). size-E 132 M conforming to IS:2148-2004 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C6 FLP squirrel cage induction motor M/S Crompton 104 of 1975 06.05.2010 rated at 1.5 KW(2 HP), 381/440 V, Greaves Limited 3 phase, 50 Hz, 2830 RPM in frame A-6/2, MIDC size-E90L conforming to IS:2148- Ahmednagar-414 2004 and IS:13346-2004 for use in 111 (Maharashtra). Zone 1 & Zone 2 hazardous areas of Oil Mines. C7 Flameproof squirrel cage induction M/S Crompton 127 of 1976 07.01.2010 motor rated at 90 KW(120 HP), Greaves Limited 381/440 V, 3 phase, 1500 RPM, 50 A-6/2, MIDC Hz in frame size-E 280 M Ahmednagar-414 conforming to IS:2148-2004 and 111 (Maharashtra). IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C8 Flameproof fan cooled squirrel cage M/S Crompton 119 of 1976 30.09.2009 induction motor rated at 18.5 Greaves Limited KW(25 HP), 381/440 V, 3 phase, 50 A-6/2, MIDC Hz in frame size : E 160L in cast Ahmednagar-414 iron construction with detachable 111 (Maharashtra). terminal box fitted with cable sealing box conforming to IS:2148- 2004 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C9 Flameproof fan cooled squirrel cage M/S Crompton 45 of 1970 30.09.2009 induction motor rated at 30 KW(40 Greaves Limited HP), 381/440 V, 3 phase, 50 Hz in A-6/2, MIDC frame size : E 200L in cast iron Ahmednagar-414 construction with detachable 111 (Maharashtra). terminal box fitted with cable sealing box conforming to IS:2148- 2004 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C10 Flameproof squirrel cage induction M/S Crompton 137 of 1977 07.05.2011 motor rated at 3.7 KW(5 HP), Greaves Limited 381/440 V, 3 phase, 50 Hz, 2920 A-6/2, MIDC RPM in frame size-E 112M Ahmednagar-414 conforming to IS:2148-2004 and 111 (Maharashtra). IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C11 FLP squirrel cage induction motor M/S Crompton 145 of 1977 07.05.2010 rated at 2.2 KW(3 HP), 381/440 V, Greaves Limited 3 phase, 50 Hz, 3000 synchronous A-6/2, MIDC RPM, continuous duty with class ‘F’ Ahmednagar-414 insulation in frame size-E 100L 111 (Maharashtra). conforming to IS:2148-2004 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C12 FLP squirrel cage induction motor M/S Crompton 160 of 1978 07.05.2009 rated at 187 KW(250 HP), 381/440 Greaves Limited V, 3 phase, 50 Hz, 1480 RPM in A-6/2, MIDC frame size-E 315L conforming to Ahmednagar-414 IS:2148-2004 and IS:13346-2004 111 (Maharashtra). for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. C13 Flameproof squirrel cage induction M/S Crompton 125 of 1976 29.03.2010 motor rated at 110 KW (150 HP), Greaves Limited 381/440 V, 3 phase, 50 Hz, 1475 A-6/2, MIDC RPM in frame size-E 315 M Ahmednagar-414 conforming to IS:2148-2004 and 111 (Maharashtra). IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. B1 Flameproof foot mounted fan cooled M/S Bharat Bijlee 333 of 1994 23.11.2009 squirrel cage induction motor rated Ltd., No. 2, MIDC at 2.2 KW, 415 V, 1430 RPM, 50 Thane : Belapur Hz in frame size MJ100(IEC frame Road, Opp. Airoli size-100) conforming to IS:2148- Railway Station 2004, IS:325-1996 and IS:13346- Navi Mumbai–400 2004 for use in Zone 1 & Zone 2 708 (Maharashtra). hazardous areas of Oil Mines. B2 Flameproof squirrel cage induction M/S Bharat Bijlee 11 of 1987 14.01.2010 motor in frame size MJ180 (IEC Ltd., No. 2, MIDC frame size-180) rated at 22 KW, 4 Thane : Belapur pole, 415 V, 3 phase, 1500 RPM, 50 Road, Opp. Airoli Hz AC conforming to IS:2148-2004, Railway Station IS:325-1996 and IS:13346-2004 for Navi Mumbai–400 use in Zone 1 & Zone 2 hazardous 708 (Maharashtra). areas of Oil Mines. B3 Flameproof fan cooled foot mounted M/S Bharat Bijlee 12 Group- 30.09.2010 squirrel cage induction motor in cast Ltd., No. 2, MIDC IIA & IIB of iron construction in frame Thane : Belapur 1987 size:MJ130(IEC frame size-132M) Road, Opp. Airoli rated at 7.5 KW, 415 V, 3 phase, 50 Railway Station Hz, 750 RPM, 14 A, 8 pole Navi Mumbai–400 conforming to IS:2148-2004, 708 (Maharashtra). IS:325-1996 and IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. B4 Flameproof squirrel cage induction M/S Bharat Bijlee 152 of 2006 06.04.2010 motor in cast iron body in frame size Ltd., No. 2, MIDC MJ112 (IEC frame size-112M) rated Thane : Belapur at 3.7 KW(5 HP), 4 pole, 415 V, 3 Road, Opp. Airoli phase, 1500 RPM, 50 Hz AC Railway Station conforming to IS:2148-2004, Navi Mumbai–400 IS:325-1996 and IS:13346-2004 for 708 (Maharashtra). use in Zone 1 & Zone 2 hazardous areas of Oil Mines. B5 Flameproof squirrel cage induction M/S Bharat Bijlee 161 of 2007 21.03.2010 motor rated at 55 KW, 415 V, 3 Ltd., No. 2, MIDC phase, 3000 RPM, 50 Hz in frame Thane : Belapur size MJ250 (IEC frame size-250M) Road, Opp. Airoli in cast iron construction conforming Railway Station to IS:2148-2004, IS:325-1996 and Navi Mumbai–400 IS:13346-2004 for use in Zone 1 & 708 (Maharashtra). Zone 2 hazardous areas of Oil Mines. B6 Flameproof squirrel cage induction M/S Bharat Bijlee 162 of 2007 21.03.2010 motor, type-INJ0 164-4 in frame Ltd., No. 2, MIDC size-16 LFP rated at 15 KW, upto Thane : Belapur and including 650 V, 3 phase, 50 Road, Opp. Airoli Hz, 1500 RPM (syn.) Railway Station Navi Mumbai–400 708 (Maharashtra). B7 Flameproof squirrel cage induction M/S Bharat Bijlee 163 of 2007 21.03.2010 motor rated at 30 KW, 550 V, 3 Ltd., No. 2, MIDC phase, 50 Hz, 1465 RPM in frame Thane : Belapur size-MJ200 (IEC frame size 200L) Road, Opp. Airoli conforming to IS:2148-2004, Railway Station IS:325-1996 and IS:13346-2004 for Navi Mumbai–400 use in Zone 1 & Zone 2 hazardous 708 (Maharashtra). areas of Oil Mines. B8 FLP fan cooled foot mounted M/S Bharat Bijlee 455 of 1998 08.07.2010 squirrel cage A.C. induction motor Ltd., No. 2, MIDC rated at 45 KW, 415 V, 3 phase, 50 Thane : Belapur Hz, 1000 RPM (syn.) in frame size- Road, Opp. Airoli MJ225 (IEC frame size-225 S/M) Railway Station conforming to IS:2148-2004, Navi Mumbai–400 IS:325-1996 and IS:13346-2004 for 708 (Maharashtra). use in Zone 1 & Zone 2 hazardous areas of Oil Mines. B9 Flameproof foot mounted fan cooled M/S Bharat Bijlee 19 Group- 24.11.2010 squirrel cage induction motor in Ltd., No. 2, MIDC IIA & IIB of frame size-MJ90 (IEC frame size- Thane : Belapur 1987 90) rated at 0.75 KW, 415 V, 3 Road, Opp. Airoli phase, 50 Hz, 1500 RPM Railway Station conforming to IS:2148-2004, Navi Mumbai–400 IS:325-1996 and IS:13346-2004 for 708 (Maharashtra). use in Zone 1 & Zone 2 hazardous areas of Oil Mines. B10 FLP AC squirrel cage induction M/S Bharat Bijlee 141 of 2004 10.08.2010 motor in frame size MJ80 (IEC Ltd., No. 2, MIDC frame size-80) rated at 0.75 KW, Thane : Belapur 415 V, 50 Hz, 1405 RPM in cast Road, Opp. Airoli iron construction conforming to Railway Station IS:2148-2004, IS:325-1996 and Navi Mumbai–400 IS:13346-2004 for use in Zone 1 & 708 (Maharashtra). Zone 2 hazardous areas of Oil Mines. K1 Explosionproof vibrator motor in KEM TRON 147 of 2005 16.11.2009 steel construction model & frame TECHNOLOGIES, size-ULBK-40-35/4, 1800 watts, INC 380 V, 3.8 A, 3 phase, 50 Hz, 1440 10404-B Cash Road, rpm, conn-Y, continuous duty Class- Stafford, TEXAS- F insulation manufactured by M/s 77477 INVICTA VIBRATIORS, USA ENGLAND conforming to IS:2148- 1981 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India K2 Flameproof/weatherproof shaker KEM TRON 148 of 2005 16.11.2009 starter control panel in sand copper TECHNOLOGIES, free aluminium construction model INC no. KTL-EALS-SB upto 460 V, 5 A, 10404-B Cash Road, 50 Hz conforming to IS:2148-2004 Stafford, TEXAS- (IEC 60079-1/2001) & IP-56 of 77477 IS:12063-1987 (IEC 60529/1989) USA manufactured by M/s KEM TRON TECHNOLOGIES, INC, USA for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India K3 Explosionproof vibrator motor in KEM TRON 133 of 2003 02.12.2010 steel construction, model & frame TECHNOLOGIES, size-ULBK-30-25/4, 1150 W, 415 INC V, 2.5 A, 1440 RPM, 3 phase, 50 10404-B Cash Road, Hz, Conn.-Y, duty-Cont., Ins. Class- Stafford, TEXAS- F manufactured by M/s Invicta 77477 Vibrators, England conforming to USA IS:2148-1981 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India LHP1 Flameproof induction motor in cast Laxmi Hydraulics 167 of 2007 11.12.2009 iron construction rated at 30 KW, Pvt. Ltd. 550 V, 3 phase, 50 Hz, insulation B-11, MIDC : class ‘F’ in frame size-LF-200 M/L Chincholi conforming to IS:2148-2004 and Solapur-413 IS:13346-2004 for use in Zone 1 & 255(Maharashtra) Zone 2 hazardous areas of Oil Mines. LHP2 Flameproof foot mounted induction Laxmi Hydraulics 168 of 2007 11.12.2009 motor in cast iron construction rated Pvt. Ltd. at 75 KW, 550 V, 3 phase, 50 Hz, B-11, MIDC : 1480 RPM insulation class ‘F’ in Chincholi frame size-280 S conforming to Solapur-413 IS:2148-2004 and IS:13346-2004 255(Maharashtra) for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. LHP3 Flameproof squirrel cage induction Laxmi Hydraulics 169 of 2008 11.01.2010 motor in frame size-LF-160 M/L Pvt. Ltd. rated at 15 KW, 550 V, 3 phase, 50 B-11, MIDC : Hz conforming to IS:2148-2004 and Chincholi IS:13346-2004 for use in Zone 1 & Solapur-413 Zone 2 hazardous areas of Oil 255(Maharashtra) Mines. LHP4 Flameproof foot mounted squirrel Laxmi Hydraulics 170 of 2008 11.01.2010 cage induction motor in frame size- Pvt. Ltd. LF-180 M/L rated at 18.5 KW(25 B-11, MIDC : HP), 550 V, 3 phase, 50 Hz Chincholi conforming to IS:2148-2004 and Solapur-413 IS:13346-2004 for use in Zone 1 & 255(Maharashtra) Zone 2 hazardous areas of Oil Mines. LHP5 Flameproof induction motor in cast Laxmi Hydraulics 171 of 2008 11.01.2010 iron construction in frame size-225 Pvt. Ltd. S/M rated at 45 KW, 550 V, 3 B-11, MIDC : phase, 50 Hz, insulation class ‘F’ Chincholi conforming to IS:2148-2004 and Solapur-413 IS:13346-2004 for use in Zone 1 & 255(Maharashtra) Zone 2 hazardous areas of Oil Mines. LHP6 Flameproof/weatherproof foot Laxmi Hydraulics 172 of 2008 11.01.2010 mounted induction motor in cast Pvt. Ltd. iron construction in frame size-250 B-11, MIDC : M rated at 55 KW, 550 V, 3 phase, Chincholi 50 Hz, 4 pole, 1440 RPM, insulation Solapur-413 class ‘F’ conforming to IS:2148- 255(Maharashtra) 2004, IS:4691-1985 and IS:13346- 2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. LHP7 Flameproof foot mounted induction Laxmi Hydraulics 173 of 2008 11.01.2010 motor in cast iron construction rated Pvt. Ltd. at 110 KW, 550 V, 3 phase, 50 Hz, B-11, MIDC : 1485 RPM, insulation class ‘F’ in Chincholi frame size-315 S conforming to Solapur-413 IS:2148-2004 and IS:13346-2004 255(Maharashtra) for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. LKP8 Flameproof/weatherproof squirrel Laxmi Hydraulics 195 of 2009 16.01.2010 cage induction motor rated at 7.5 Pvt. Ltd. KW (10 HP), 415 V, 3 phase, 50 Hz B-11, MIDC : in frame size-LF-132 S/M in cast Chincholi iron construction manufactured by Solapur-413 M/S Laxmi Hydraulics Pvt. Ltd., 255(Maharashtra) Solapur conforming to IS:2148-2004 and IS:13346-2004 for use in Zone 1 and Zone-2 hazardous areas of Oil Mines. M1 Flameproof fan cooled foot mounted Marathon Electric 34 Group- 07.07.2009 squirrel cage induction motor rated Motors (India) IIA & IIB of at 18.5 KW, 500/550 V, 3 phase, 4 Limited, Paharpur 1989 pole, 50 Hz, 1500 RPM in frame Works, 58, Taratala size-KF180 M&L conforming to Road, Kolkata-700 IS:2148-2004 & IS:13346-2004 for 024 use in Zone 1 & Zone 2 hazardous areas of oil mines. M1 FLP squirrel cage induction motor Marathon Electric 35 Group- 25.05.2010 rated at 7.5 KW(10 HP), 414 V, 3 Motors (India) IIA & IIB of phase, 50 Hz, 1500 RPM in frame Limited, Paharpur 1989 size KF132 S&M conforming to Works, 58, Taratala IS:2148-2004 & IS:13346-2004 for Road, Kolkata-700 use in Zone 1 & Zone 2 hazardous 024 areas of oil mines. M2 FLP fan cooled foot mounted Marathon Electric 36 Group- 26.04.2011 squirrel cage induction motor rated Motors (India) IIA & IIB of at 15 KW, 3 phase, 415 V, 50 Hz, Limited, Paharpur 1989 1470 RPM in frame size-KF 160L Works, 58, Taratala conforming to IS:2148-2004 & Road, Kolkata-700 IS:13346-2004 for use in Zone 1 & 024 Zone 2 hazardous areas of oil mines. M3 Flameproof squirrel cage induction Marathon Electric 37 Group- 28.02.2010 motor rated at 37 KW (50 HP), 3 Motors (India) IIA & IIB of phase, 500/550 V, 50 Hz, 1500 RPM Limited, Paharpur 1989 in frame size-KF225 S&M Works, 58, Taratala conforming to IS:2148-2004 & Road, Kolkata-700 IS:13346-2004 for use in Zone 1 & 024 Zone 2 hazardous areas of oil mines. M4 FLP cum weatherproof squirrel cage Marathon Electric 38 Group- 25.05.2010 induction motor rated at 90 KW, 550 Motors (India) IIA & IIB of V, 3 phase, 50 Hz, 1480 RPM in Limited, Paharpur 1989 frame size-KF 280 M conforming to Works, 58, Taratala IS:2148-2004 & IS:13346-2004 for Road, Kolkata-700 use in Zone 1 & Zone 2 hazardous 024 areas of oil mines. M5 FLP squirrel cage induction motor Marathon Electric 39 Group- 24.05.2011 rated at 55 KW, 3 phase, 415 V, 50 Motors (India) IIA & IIB of Hz, 1500 RPM in frame size-KF 250 Limited, Paharpur 1989 M conforming to IS:2148-2004 & Works, 58, Taratala IS:13346-2004 for use in Zone 1 & Road, Kolkata-700 Zone 2 hazardous areas of oil mines. 024 M6 Flameproof fan cooled foot mounted Marathon Electric 70 of 1991 26.06.2010 squirrel cage induction motor rated Motors (India) at 1.5 KW, 2-8 pole, 3 phase, 415 V, Limited, Paharpur 50 Hz, 1500 RPM in frame size-KF Works, 58, Taratala 112M conforming to IS:2148-2004 Road, Kolkata-700 & IS:13346-2004 for use in Zone 1 024 & Zone 2 hazardous areas of oil mines. M7 FLP squirrel cage induction motor Marathon Electric 94 of 1992 28.02.2010 rated at 2.2 KW, 415 V, 3 phase, 50 Motors (India) Hz, 1425 RPM in frame size KF- Limited, Paharpur 90S&L conforming to IS:2148-2004 Works, 58, Taratala & IS:13346-2004 for use in Zone 1 Road, Kolkata-700 & Zone 2 hazardous areas of oil 024 mines. M8 Flameproof foot mounted squirrel Marathon Electric 97 of 1995 12.08.2009 cage induction motor rated at 125 Motors (India) KW, 3 phase, 550 V, 50 Hz, 1500 Limited, Paharpur RPM in frame size-KF 315M Works, 58, Taratala conforming to IS:2148-2004 & Road, Kolkata-700 IS:13346-2004 for use in Zone 1 & 024 Zone 2 hazardous areas of oil mines. M9 Flameproof squirrel cage induction Marathon Electric 69 Group- 28.02.2010 motor rated at 30 KW, 550 V, 3 phase, Motors (India) IIA & IIB of 50 Hz, 1500 RPM in frame size-KF Limited, Paharpur 1991 200L conforming to IS:2148-2004 & Works, 58, Taratala IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines Road, Kolkata-700 024 K1 Flameproof fan cooled, foot Kirloskar Electric 171 of 1979 16.12.2009 mounted squirrel cage induction Company Limited motor rated at 220 KW, 3 phase, 370 Unit-II Gokul Road, A, 415 V in frame size LE-315L P.B. no.112 conforming to IS:2148-2004, Hubli-580 030 IS:13346-2004 and IS:325-1996 for (Karnataka). use in Zone 1 & Zone 2 hazardous areas of Oil Mines. K2 3 phase, rated voltage upto 650 V, Kirloskar Electric 36 of 1969 25.09.2012 50 Hz, flameproof squirrel cage Company Limited induction motors in frame sizes NE- Unit-II, P.B. no.112 112, NE-132, NE-160, NE-180 and Hubli-580 030 NE-200 redesignated as frame sizes (Karnataka). LE-112, LE-132, LE-160, LE-180 and LE-200, rated upto and including 3.7 KW, 1430 RPM, 5.5 KW, 2900 RPM, 11 KW, 2935 RPM, 22 KW, 1500 RPM and 30 KW, 2955 RPM respectively conforming to IS:2148-2004, IS:13346-2004 and IS:325-1996 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. K3 Flameproof squirrel cage induction Kirloskar Electric 226 of 1982 10.03.2010 motor in frame size-LE225M, rated Company Limited at 37 KW, 75 A, 415 V, 3 phase, 50 Unit-II, P.B. no.112 Hz, 1475 RPM conforming to Hubli-580 030 IS:2148-2004, IS:13346-2004 and (Karnataka). IS:325-1996 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. K4 Flameproof fan cooled foot mounted Kirloskar Electric 227 of 1982 31.12.2009 squirrel cage induction motor rated Company Limited at 37 KW, 415 V in frame size LE- Unit-II, P.B. no.112 250M conforming to IS:2148-2004, Hubli-580 030 IS:13346-2004 and IS:325-1996 for (Karnataka). use in Zone 1 & Zone 2 hazardous areas of Oil Mines. K5 Flameproof fan cooled foot mounted Kirloskar Electric 245 of 1984 31.12.2009 squirrel cage induction motor in Company Limited frame size LE-280S/M rated at 125 Unit-II, P.B. no.112 KW, 415 V conforming to IS:2148- Hubli-580 030 2004, IS:13346-2004 and IS:325- (Karnataka). 1996 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. K6 Flameproof squirrel cage induction Kirloskar Electric 138 of 2004 18.03.2010 motor rated at 300 KW, 3.3 KV, 6 Company Limited pole, 3 phase, 50 Hz in frame size- Unit-II, P.B. no.112 FLP 355 in cast iron Gr. FG200 and Hubli-580 030 mild steel fabricated construction (Karnataka). conforming to IS:2148-2004, IS:4691-1985 & IS:13346-2004 for use in Zone 1 & Zone 2 hazardous areas of Oil Mines. T1 Flameproof/weatherproof Technotalent 179 of 2008 04.04.2010 explosionproof electric vibrator F23-24, Kushal (electric motor with eccentric Garden Arcade weights in both shaft-ends) rated at Plot no. 1-A, Phase- 2 HP, 415 V, 50 Hz, 3 phase, Ins. II Class-F, motor designated by type Peenya Industrial CDX, in frame size 94.60 in cast Area, Bangalore-560 iron construction conforming to 058 IS:2148-2004, IS:13346-2004 & IS:4691-1985 manufactured by M/s Italvibras Giorgio Silingardi S.p.A., Italy for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India. T2 Flameproof/weatherproof Technotalent 178 of 2008 04.04.2010 explosionproof electric vibrator F23-24, Kushal (electric motor with eccentric Garden Arcade weights in both shaft-ends) rated at Plot no. 1-A, Phase- 0.5 HP, 415 V, 50 Hz, 3 phase, Ins. II Class-F, designated by type CDX, Peenya Industrial in frame size 88.30-35 in cast iron Area, Bangalore-560 construction conforming to IS:2148- 058 2004, IS:13346-2004 & IS:4691- 1985 manufactured by M/s Italvibras Giorgio Silingardi S.p.A., Italy for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India. T3 Flameproof/weatherproof Technotalent 204 of 2009 25.05.2010 explosionproof electric vibrator Plot no. 392, 10th (electric motor with eccentric Cross, Phase-IV, weights in both shaft-ends) rated at Peenya Industrial 3 HP, 415 V, 50 Hz, 3 phase, 1500 Estate, Bangalore- RPM, Ins. Class-F, motor designated 560 058. by type CDX, in frame size 94.70 in cast iron construction conforming to IS:2148-2004, IS:13346-2004 & IS:4691-1985 manufactured by M/S Italvibras Giorgio Silingardi S.p.A., Italy for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India. T4 Flameproof/weatherproof Technotalent 205 of 2009 25.05.2010 explosionproof electric vibrator Plot no. 392, 10th (electric motor with eccentric Cross, Phase-IV, weights in both shaft-ends) rated at Peenya Industrial 1.5 HP, 415 V, 50 Hz, 3 phase, 1500 Estate, Bangalore- RPM, Ins. Class-F, motor designated 560 058. by type CDX, in frame size 94.50 in cast iron construction conforming to IS:2148-2004, IS:13346-2004 & IS:4691-1985 manufactured by M/S Italvibras Giorgio Silingardi S.p.A., Italy for use in Zone 1 & Zone 2 hazardous areas of Oil Mines in India. D1 (1)FLP/WP electric vibrating motor DERRICK 153 of 2006 01.09.2010 rated up to 600V, 3 phase, 50/60 Hz Corporation and 2.5HP, 1800 rpm, insulation class 590 Duke Road : F, model no. SGX. fitted with cable Buffalo NY14225 gland HAWK 753A ¾″ NPT USA. manufactured by M/S DERRICK Corporation, USA (2) FLP/WP starter box assembly rated up to 600V, 3 phase, 50 /60 Hz , 2.5HP with over current and earth leakage protections, model no. 15687-00 fitted with cable gland HAWK 753A ¾″ NPT manufactured by M/S DERRICK Corporation, USA.