Sunteți pe pagina 1din 1

General Notes

BIM 360://R02I16 Airport/R02I16-WSU-XX-XX-MOD-ST-00001.rvt 29/10/2019 13:50:19

KEY TO HEALTH & SAFETY SYMBOLS


1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL
WARNING RISK RELEVANT ARCHITECTS, SERVICES AND ENGINEERS DRAWINGS
INDICATES A RESIDUAL RISK AS A WARNING. TOGETHER WITH RELEVANT SPECIFICATIONS.
1375 3700 2. DIMENSIONS ARE NOT TO BE SCALED FROM THIS DRAWING.
TOC +44.400 REFERENCE DRAWINGS:
COMPULSORY RISK
1625 1375 GENERAL NOTES: R02I16-WSU-XX-XX-DWG-ST-00110 ONWARDS
INDICATES A RESIDUAL RISK REQUIRING A
3. FOR DESCRIPTIONS OF SYMBOLS AND ABBREVIATIONS REFER
COMPULSORY ACTION.
RC4000x3000x750dp TO GENERAL NOTES DRAWING

0
40

40

40

40

40
1375

0x

0x

0x

0x

0x
PF PROHIBITIVE RISK 4. ALL GRIDLINES ARE TO BE SET OUT IN ACCORDANCE WITH THE

40

40

40

40

40
RC250 RC250

RC

RC

RC

RC

RC
INDICATES A RESIDUAL RISK REQUIRING A PROHIBITIVE RELEVANT ARCHITECTS DRAWINGS.

3000
ACTION. 5. ALL COLUMNS ARE TO BE SET OUT SYMMETRICALLY ABOUT THE
3400 GRIDLINES UNO
INFORMATION RISK 6. HOLES LESS THAN 150x150mm ARE NOT SHOWN. REFER TO
INDICATES A RESIDUAL RISK FOR INFORMATION. SPECIALIST OR ARCHITECTS DRAWINGS.

4000

3400

3400
RC250

RC250
3700

RC250

RC250
SUB-1 5075 x 3000 x 750dp
L-SHAPED FOUNDATION

3000 GB300

SSL +45.000

RC7000x3500x750dp RC7000x3500x750dp RC7000x3500x750dp RC7000x3500x750dp


PF PF PF PF

EXTERNAL GROUND

0
40

40

40

40

40
1703

0x

0x

0x

0x

0x
BEARING SLAB

40

40

40

40

40
RC

RC

RC

RC

RC
SUB-2
3600

0
40

40

40

40
0x

0x

0x

0x
40

40

40

40
RC

RC

RC

RC
1697

RC250

RC250
4000

3400
0

0
40

40

40

40
0x

0x

0x

0x

0
1625

40
40

40

40

40

0x
RC

RC

RC

RC
RC250 RC250

40
RC
1375

RC4000x3000x750dp 3400
PF
RC4000x3000x750dp PF
4000 1625 1375

PAD FOUNDATIONS TO BE GROUND FLOOR LAYOUT PLAN.


RC3500x3500x750dp FOUNDATION LAYOUT PLAN. 1 : 100
GROUND BEAMS TO BE RC1000x500dp 1 : 100
RC75 TOPPING
ALL FOUNDATIONS ARE 600mm BELOW SSL
(TOC 44.400) AND PLACED CENTRALLY
BELOW COLUMNS AND WALLS.

75
200 200 200

25 265
310
PC265 PC265

RC600x600w

RC600x600w
00 10/30/19 FINAL SUBMISSION JM
SUB - 1A (TYPICAL INTERNAL BEAM). Rev. Date Reason For Issue Chk

1 : 20 SCHEMATIC DESIGN
Key Plan.

SSL +49.550
265 DEEP HOLLOWCORE
FLOOR UNITS WITH
75mm TOPPING.
RC75 TOPPING
RF - SUB STN
+49.550 m

RC600x600w
PC265 PC265 PC265 PC265
RC600x600w RC600x600w RC600x600w RC600x600w RC600x600w
RC600x600w

RC600x600w

RC600x600w

RC600x600w

RC600x600w

N
Lighting Consultant

RC600x600w
RC250 RC250

Food Service Design Consultant


EXTERNAL GROUND
BEARING SLAB GB300 SUBSTATION G.F.L.
+45.000 m

SUBSTATION FOUNDS

600
+44.400 m

Value Engineers

RC600x600w RC500x1000 GB RC500x1000 GB RC500x1000 GB


RC4000x3000x750dp
L-SHAPED PF
FOUNDATION

Multidisciplinary Consultant

ROOF LAYOUT PLAN. SECTION SUB-1


1 : 100 1 : 50

Design Lead Architect

Riverside, 22 Hester Road


London SW11 4AN
RC75 TOPPING RF - SUB STN T +44(0)20 7738 0455
+49.550 m F +44(0)20 7738 1107
www.fosterandpartners.com © Foster + Partners 2019

Client

RC600x600w RC600x600w RC600x600w RC600x600w


RC400x400

RC400x400

RC400x400

RC400x400

RC400x400
Project

RED SEA AIRPORT


EXTERNAL GROUND SITE/GENERAL
BEARING SLAB SUBSTATION G.F.L.
GB300
+45.000 m UTILITY HUB
SUBSTATION FOUNDS & SUBSTATIONS

600
+44.400 m
Title

AIRFIELD SUBSTATION
RC500x1000 GB RC500x1000 GB RC500x1000 GB
RC7000x3500x750dp RC7000x3500x750dp RC7000x3500x750dp RC7000x3500x750dp RC3500x3500x750dp
PF PF PF PF PF

SECTION SUB-2
Last saved in Autodesk Revit 2019.

Project No Scale at ISO A0 Sheet First Issue Date Drawn By


1 : 50 70055795 1:100 30/10/19 ET
N

Sheet Number Revision


R02I16-WSU-XX-ZZ-DWG-ST-33012 00