This test method is under the jurisdiction of ASTM Committee B09 on Metal
Powders and Metal Powder Products and is the direct responsibility of B09.02 on
Base Metal Powders.
Current edition approved Oct. 1, 2003. Published October 2003. Originally
3
approved in 1946. Last previous edition approved in 1997 as B 213 – 97. The flowmeter funnel, stand, and Chinese emery are available from AcuPowder
2
Annual Book of ASTM Standards, Vol 02.05. International, LLC.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
B 213 – 03
FIG. 2 Stand
2
B 213 – 03
however, or poking or stirring of the powder in the funnel with 13. Precision and Bias
a wire or any other implement is not permitted. 13.1 Precision—Precision has been determined from an
10.1.7 Stop the stopwatch the instant the last of the powder interlaboratory study performed by seven laboratories of Sub-
exits the orifice. committee B09.02.4
10.1.8 Record the elapsed time to the nearest 0.1 s. 13.1.1 Repeatability intervals, r, are listed in Table 1. In
10.1.9 More than one flow may be run if desired. Use a 95 % of flow rate determinations, on the basis of test error
fresh 50.0 g quantity of powder for each flow test. Average the alone, duplicate tests in the same laboratory by the same
flow times. operator on one homogeneous lot of powder will differ by no
10.2 Method 2—Moving Powder Start to Flow Measure- more than the stated amount in seconds.
ment: 13.1.2 Reproducibility intervals, R , are listed in Table 1.
10.2.1 Place an empty receptacle directly under the dis- For 95 % of comparative trials done in two different laborato-
charge orifice. ries, and on the basis of test error alone, single tests on the
10.2.2 Weigh out a 50.0 g mass of powder, as sampled, into same homogeneous lot of powder will differ by no more than
a clean weighing dish. the stated amount in seconds.
10.2.3 Pour the 50.0 g powder specimen into the center of 13.2 Bias—No statement can be made about bias, because
the funnel and start the stopwatch the instant the powder exits there is no standard reference material for flow rate measure-
the orifice. ment.
10.2.4 Stop the stopwatch the instant the last of the powder
exits the orifice. 14. Keywords
10.2.5 Record the elapsed time to the nearest 0.1 s.
14.1 flow rate; metal powder flow; powder flow
10.2.6 More than one flow may be run if desired. Use a
fresh 50.0 g quantity of powder for each flow test. Average the
flow times. TABLE 1 Precision of Flow Rate Measurements of Metal
Powders
11. Calculation
Apparent Flow Repeatability Reproducibility
11.1 Calculate the correction factor by dividing 40.0 by Powder Density Rate 3 Avg. (r ) Avg. 3 (R ) Avg. 3
either the flow rate stamped on the bottom of the funnel, or the (g/cm3) (s/50 g) Flows (s) Flows (s)
new calibration flow rate established in 9.3. Spherical bronze 5.04 12 0.1 0.8
11.2 Multiply the elapsed time (see 10.1.9 or 10.2.6) by the Iron #1 2.46 31 0.7 2.5
Iron #2 3.03 26 1.0 2.1
desired correction factor (see 11.1). Iron (lubricated) 3.18 26 1.3 2.2
Bronze premix 3.31 31 1.7 2.6
12. Report (lubricated)
Brass 3.61 42 4.1 8.7
12.1 Report the corrected flow rate in seconds to the nearest (lubricated)
second.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).