These valves are a combination of a pilot operated relief valve and a solenoid operated
directional valve. Piping between the two is eliminated as the solenoid valve is directly
mounted on the relief valve and connected with the relief valve vent. Pump pressure
may be unloaded remotely by an electrical signal to the solenoid, or by connecting pilot
relief valves to the solenoid valve ports.
Specifications
Max. Pressure Max. Approx. Mass kg (lbs.)
Operating Adj. Flow With
Model Numbers Double Single
Pressure Range L/min Vent
MPa (PSI) MPa (PSI) (U.S.GPM) Sol. Sol.
Restrictor
BST-03-*-*-*-*-48* 100 (26.4) 7.1 (15.7) 6.6 (14.6) 7.6 (16.8)
Note)
Threaded
BST-06-*-*-*-*-48* 25 (3630) -25 200 (52.8) 7.1 (15.7) 6.6 (14.6) 7.6 (16.8)
Connection
( -3630)
BST-10-*-*-*-*-48* 400 (106) 10.8 (23.8) 10.3 (22.7) 11.3 (24.9)
BSG-03-*-*-*-*-48* 100 (26.4) 6.8 (15.0) 6.3 (13.9) 7.3 (16.1)
Note)
Sub-plate
BSG-06-*-*-*-*-48* 25 (3630) -25 200 (52.8) 7.7 (17.0) 7.2 (15.9) 8.2 (18.1)
Mounting
( -3630)
BSG-10-*-*-*-*-48* 400 (106) 11.0 (24.3) 10.5 (23.2) 11.5 (25.4)
Note: For relief valves, standard pilot operated relief valves are used.
For minimum adjustment pressures and other characteristics, see page 214.
None:
AC: None:
T:
3 Terminal
F: 2B3A A100, A120 Japanese
03 Box Type
A: Threaded 2 A200, A240 Std. "JIS"
Special 1 BS: V: For High 2B3B
Seals for With Vent Connection N: With
Venting
Phosphate Restrictor Solenoid Pressure 2B2B DC: Plug-in 90:
Ester Type Controlled 06 Connector 48 N. American
(Option- Feature 2B2 D12 , D24
Fluids Relief (Omit if not (DIN) Design Std.
Omit if not G: D48
(Omit if not Valves 3C2
required) required)
required) Sub-plate 10 N: With 80:
Mounting 3C3 AC DC: Plug-in
R100, R200 European
Connector
Design Std.
(DIN)
1. Models with vent restrictor are applicable only for the vent type 2B3A and 2B3B. For details, see page 222.
2. Use high venting pressure types to reduce response time from unloading to onloading.
3. For the details of the vent types, see the following page.
4. The coil codes are the same as for solenoid operated directional valve DSG-01. See the Solenoid Ratings on page 345.
The coil type numbers in the shaded column are handled as optional extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
Vent Types
Solenoid Operated Operation
Vent Type Graphic Symbols Directional Valve
Model Number SOL "a" SOL "b" Vent Connecting
"A"
OFF Connected to port "A".
b
2B3A DSG-01-2B3A
Solenoid Controlled
ON Connected to port "B".
Relief Valves
"B"
Closed state (relief valve
OFF
b setting pressure)
2B2B DSG-01-2B2B
"A" "B"
OFF Connected to port "A".
b
2B2 DSG-01-2B2
"A" "B"
OFF OFF Connected to tank (no-load)
a b
3C3 DSG-01-3C3 ON OFF Connected to port "A".
Attachment
Mounting Bolts
Valve Model Socket Head Cap Screw
Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std.
BSG-03 M12 70 Lg. (2 pcs.), M12 95 Lg. (2 pcs.) 1/2-13UNC 2-3/4 Lg. (2 pcs.), 1/2-13UNC 3-3/4 Lg. (2 pcs.)
BSG-06 M16 60 Lg. (2 pcs.), M16 80 Lg. (2 pcs.) 5/8-11UNC 2-1/4 Lg. (2 pcs.), 5/8-11UNC 3-1/4 Lg. (2 pcs.)
BSG-10 M20 70 Lg. (2 pcs.), M20 90 Lg. (2 pcs.) 3/4-10UNC 2-3/4 Lg. (2 pcs.), 3/4-10UNC 3-1/2 Lg. (2 pcs.)
Option
Models with vent restrictor
The type with a vent restrictor has a vent restrictor in vent types 2B3A and 2B3B added between a relief valve and
a solenoid operated directional valve. If prevents shock to the main circuit by gradually lowering the venting pressure
in the shift from the set pressure to unloading.
Unloading pressure are the same as without a vent restrictor.
A-BS*-*-2B3A A-BS*-*-2B3B
b b
Instructions
If a remote control relief valve is used in the vent circuit, see page 203. In addition, if the internal volume of the vent
line is too large, chattering is likely to occur. Thus, as far as possible reduce the inside diametre and the length of the
pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressures or anti-clock-
wise for lower pressures. After adjustments, do not forget to tighten the lock nut.
Piping of the tank line should not be connected to any tank line of the other valves, but connected directly to the
reservoir.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is
equivalent to 10 MPa (1450 PSI).
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a flow rate above
8 L/min (2.1 U.S. GPM) and model 10 with 15 L/min (4.0 U.S. GPM).
BST-03-*-*-*-48/4890 DIMENSIONS IN
BST-06-*-*-*-48/4890 MILLIMETRES (INCHES)
BST-10-*-*-*-48/4890
C
Solenoid Indicator Light
"C" SQ.
Solenoid Controlled
Space Needed to Remove
Relief Valves
Solenoid-Each End
DC/R :204.4(8.05) DC/R :50(1.97)
AC :196.4(7.73) AC :45.5(1.79)
47.5 DC/R :102.2(4.02)
D (1.87) AC :98.2(3.87)
Pressure Adjustment Handle 47.5 Electrical Conduit Connection
46 "r" Thd. (Both Ends)
(1.81) (1.87)
INC.
Manual Actuator
Lock Nut 14(.55) Hex. 6(.24) Dia.
SOL a SOL b
44(1.73)
Q
Dia.
T
Vent Port
N
"W" Thd.
"k" Thd.
U
V
Two Collars
Pressure Port
S
"X" Thd. P
Tank Port 2 Places
"X" Thd.
Pressure Gauge Connection K Remote Control Port "A"
"E" Sq. "h" Thd. "W" Thd.
L
F
Fully Extended
H
There are two threaded connection pressure ports. They can be connected each other in-line; one as inlet and the other
as an outlet or the valve can be used by plugging one of the pressure ports.
Dimensions mm (Inches)
Model Numbers
C D E F H K L N P Q S T U V
BST-03-*-48/4890
75 40 52 78 145 45 90 239.3 68.5 152.5 36 105.5 69 62
(2.95) (1.57) (2.05) (3.07) (5.71) (1.77) (3.54) (9.42) (2.70) (6.00) (1.42) (4.15) (2.72) (2.44)
BST-06-*-48/4890
SOL a SOL b
BST-03-*-D*-N 68.5 105.5 250 169.5
BST-06-*-D*-N (2.70) (4.15) (9.84) (6.67) 39
QQ
SOL b SOL b
QQ
Q
NN
T
T
For other dimensions, see the models without vent restrictor type on page 223 and 224.
Mounting surface
BSG-03-*-*-*-48/4890 BSG-03: ISO 6264-AR-06-2-A
BSG-06-*-*-*-48/4890 BSG-06: ISO 6264-AS-08-2-A
BSG-10: ISO 6264-AT-10-2-A
BSG-10-*-*-*-48/4890
Solenoid Controlled
Space Needed to Remove
Mounting Surface Solenoid-Each End
(O-Rings Furnished)
Relief Valves
DC/R :204.4(8.05) DC/R :50(1.97)
AC :196.4(7.73) AC :45.5(1.79)
47.5 DC/R :102.2(4.02)
D (1.87) AC :98.2(3.87) Electrical Conduit Connection
46 47.5 "f" Thd. (Both Ends)
(1.81) (1.87)
Pressure Adjustment
Handle
Manual Actuator
INC. 6(.24) Dia.
Two Collars
SOL a SOL b
Remote Control Port "A"
"d" Thd.
44(1.73)
S
Dia.
U
"d" Thd.
P
V
X
Lock Nut
14(.55) Hex. Vent Port
Locating Pin
6(.24) Dia.
Pressure Gauge Connection T
6 "e" Thd. Q
(.24)
Pressure Port
b N
Fully Extended
J
SS
(4.33) (4.27) (11.59) (6.79)
Remote
U
PP
Control BSG-03-*-R*-N 77 83.5 239.5 140.7
Design 4880 Only (3.03) (3.29) (9.43) (5.54)
Port "B"
"d" Thd. 83.5 101 263.5 158.2 53
BSG-06-*-R*-N (3.29) (3.98) (10.37)
Vent Port (6.23) (2.09)
BSG-10-*-R*-N 110 108.5 297.5 165.7
Q
SOL b SOL b
SS
S
U
PP
P
Q
For other dimensions, see the models without vent restrictor type on page 225 and 226.
Threaded Connections
Terminal Box Type
03
BST- 06 -*-*-*-48/4890 16 23
10
C
8 10 12 13 15 14
Solenoid Controlled
11
Relief Valves
19
2
21
1
9
6
22
3
20
4
5
41 37 29 18 30 40 31
SOL a SOL b
34 28
35 36
Sub-plate Mounting
Terminal Box Type
03
BSG- 06 -*-*-*-48/4890 16 26
10
8 10 12 13 15 14
11
19
2
22 21
6 9
3 24
25 20
4 5
23 1
Option
Models with Plug-in Connector Models with Vent Restrictor
03 03
48/4890
BSG- 06 -*-*-*-N-48/4880/4890 A-BSG- 06 -*-*-*-
N-48/4880/4890
10 10
26
41 37 29 18 30 40 35
28
31 36
32 40
38
Design 4880 Only
*-BST/BSG-03/06/10-*-2B3B- -48
*-BST/BSG-03/06/10-*-2B2B- -48
DSG-01-2B3B-
DSG-01-2B2B-
-70
-70
Japanese Standard "JIS"
C
*-BST/BSG-03/06/10-*-2B2- -48 DSG-01-2B2- -70
Solenoid Controlled
*-BST/BSG-03/06/10-*-2B3B- -4890 DSG-01-2B3B- -7090
Relief Valves
N. American Design Std.
*-BST/BSG-03/06/10-*-2B2- -4890 DSG-01-2B2- -7090