Sunteți pe pagina 1din 1

26 W4031 4G 2.5 55 300 (+CC) (-X1) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+M403.

(+CC) (-X1) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+M403.1) (-M) UVR COOLING WATER PUMP INN BOTTOM DECK (BALLAST PUMP ROOM)

27 W20116 1X2 0.75 27 300 (+CC) (-X2) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+Press.JB) (-PT201.16) PRESSURE TRANSMITTER 3RD DECK (BALLAST PUMP ROOM)

28 W20132 6 0.75 38 300 (+CC) (-X2) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+EXT) (-V201.32) VALVE 3RD DECK (BALLAST PUMP ROOM)

29 W21231 4 0.75 42 300 (+CC) (-X11-K3) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+EXT) (-V212.31) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

30 W40335 6 0.75 57 300 (+CC) (-X2) CONTROL CABINET UPPER DECK (ENGINE ROOM) (+EXT) (-V403.35) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

31 W11V 6 0.75 40 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (11V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

32 W10V 6 0.75 40 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (10V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

33 W8V 6 0.75 39 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (8V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

34 W6V 6 0.75 42 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (6V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

35 W4V 6 0.75 40 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (4V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

36 W2V 6 0.75 42 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (2V) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

37 WBWTS-01 6 0.75 47 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (BWTS-01) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

38 WBWTS-02 6 0.75 43 300 (+CC) CONTROL CABINET UPPER DECK (ENGINE ROOM) (BWTS-02) VALVE INN BOTTOM DECK (BALLAST PUMP ROOM)

NOTE:

1. CABLE LENGTH INDICATED ARE TENTATIVE ONLY & IS SUBJECTED TO DIFFER THAN ACTUAL LENGTH. CABLE LENGTH ARE CALCULATED USING AVAILABLE DATA/SOURCE/3D MODEL.

2. SAFETY FACTOR OF 25% HAS BEEN ACCOUNTED FOR CALCULATING EACH CABLE LENGTH.

3. HALOGEN FREE ACCORDING TO IEC 60754-1 & 60754-2 & FLEXIBLE INSULATING SLEEVING ACCORDING TO IEC 60684-2.

4. CABLE LENGTHS ARE CALCULATED USING AVAILABLE DATA/SOURCES/3D MODEL. CABLE LENGTH INDICATED HERE ARE TENTATIVE ONLY AND ARE SUBJECTED TO DIFFER THAN ACTUAL LENGTHS.

5. ONLY SHIPYARD/OWNER SCOPE OF SUPPLY MATERIAL TO BE PROCURED, ALFA LAVAL SCOPE WILL BE PROVIDED BY THE VENDOR.

6. INSULATED END FERRULES SHALL BE USED UPTO 16 SQ.MM. FOR 25 SQ.MM & HIGHER, USE PIN OR RING TYPE LUG.

7. POWER CONDUCTORS SHALL BE BLACK & SIGNAL CONDUCTORS SHALL BE BLUE.

REFERENCES:

1. GSPL-P11122-EL-0001-REV.0 SINGLE LINE DIAGRAM.

2. PURE BALLAST SM PB 3.1 300 Ex USCG.

3. DWG. NO. E-02 WIRING DIAGRAM OF ELECTRIC POWER SYSTEM.

PAGE 03 OF 03