YOUR
PERFORMANCE
pp SUPERIOR
COST BENEFIT
pp REDUCED
POWER LOSS
pp HIGH
RELIABILITY
pp BETTER
TOLERANCE TO
MICRO CRACKS
MULTI-BUSBAR – AN OVERVIEW
Vikram Solar’s new PV module with multi-busbar cell design increases the module
power output upto 5 Wp compared to its previous version.
,, Higher number of busbars lead to multiple contact points which reduces internal
resistance.
,, Use of cylindrical tabbing wire increases the cell absorption by enhanced
scattering effect
,, Shorter distance between the busbar lowers the impact of possible microcracks
that may occur during module lifetime leading to improved long term reliability.
+ –
5.8
12 BB
9BB
5.7
5BB
Cell Power (Wp)
5.6
5.5
WHY MULTI-BUSBAR?
SUPERIOR COST
BENEFIT
MBB improves the efficiency of a REDUCED POWER LOSS
standard module, increasing the MBB allows the electrical charges
module output without adding to travel a comparatively shorter
much to the cost. Thus, customers distance with less resistance.
can enjoy cost effective solutions Lower internal resistance boosts
without compromising on power the module power helping to
output. achieve lower cell to module
conversion loss.
HIGH RELIABILITY
The possibility of lesser cell stress DESIGN USES
during module fabrication lowers CIRCULAR RIBBONS
the risk of module degradation in
Round-shaped busbar
extreme weather conditions.
increases the scattering
effect towards the cell
surface for higher cell
BETTER TOLERANCE
absorption; the result is
TO MICRO CRACKS ~1% increased module
Higher number of busbar makes performance.
the PV modules less prone to loss
in efficiency due to micro-cracks.
Electrical Data1 All data refers to STC (AM 1.5, 1000 W/m , 25°C) 2
Dimensions in mm
Peak Power Pmax (Wp) 385 390 395 400 405 410 415 1007
40
964
Maximum Voltage Vmpp (V) 40.7 40.8 40.9 40.9 41.0 41.1 41.2
Maximum Current Impp (A) 9.45 9.56 9.67 9.78 9.89 10.00 10.10
Open Circuit Voltage Voc (V) 48.7 48.8 48.9 49.1 49.2 49.3 49.4
Short Circuit Current Isc (A) 9.88 9.99 10.10 10.21 10.32 10.43 10.54
Module Efficiency η(%) 19.02 19.27 19.52 19.76 20.01 20.26 20.50
1) STC:1000 W/m2 irradiance, 25°C cell temperature, AM1.5g spectrum according to EN 60904-3. Average relative efficiency reduction of 5% at 200 W/m2 according to EN 60904-1.
1176
1767
2010
Power (W) 284.9 288.6 292.3 296.0 299.7 303.4 307.1
V@Pmax (V) 37.5 37.5 37.6 37.7 37.7 37.8 37.9
400
I@Pmax (A) 7.58 7.67 7.76 7.85 7.94 8.03 8.11
Voc (V) 45.0 45.2 45.3 45.4 45.5 45.6 45.7
Isc (A) 7.90 7.99 8.08 8.17 8.26 8.34 8.43
8-6.5×10
2) NOCT irradiance 800 W/m2, ambient temperature 20°C, wind speed 1 m/sec
Power (W)
Junction Box IP68/IP67, split junction box with individual bypass diodes 6 200
Superstrate 3.2 mm (0.125 inches) high transmission low iron tempered glass, AR coated 0 0
0 10 20 30 40 50
Cells 72 Mono PERC (144 half-cells), MBB solar cells Voltage (V)
80%
60%
Product Warranty** 10 years 1 YEAR 27 YEARS
Performance Linear Power Warranty for 27 years with 3% for 1st year degradation and 0.65%
Warranty** from year 2 to year 27 #
1200 mm (47.24 inches) cable length is also available.
Approvals and IEC 61215 Ed2:2016, IEC 61730:2016, IEC 61701, IEC 62716, IEC 60068-2-68, ** Refer to Vikram Solar’s warranty document for terms and conditions.
^ All certifications under progress.
Certificate^ IEC 62804, CE, CEC (California), UL 1703, IS/IEC 61730
VSL/ENG/SC/156
DS-9BB-144-SOM-half cell-1500V-INT-V19-E-R00
sales@vikramsolar.com
www.vikramsolar.com
◆ India: Kolkata | Gurugram | Mumbai | Pune
Bengaluru | Raipur | Surat | Ahmedabad
◆ International: Germany | USA | Singapore | China | UK
LATAM | Japan | Kenya | Uganda