E d u c a t i o n a l Tr a i n i n g E q u i p m e n t f o r t h e 2 1 s t C e n t u r y Bulletin 226-101B
H-REM-ACDC-MC
Motor Controller
Purpose
The Hampden Model H-REM-ACDC-MC
Motor Controller has been developed to pro-
vide students with the basic understanding
and principles of AC and DC motor control.
The student will gain practical experience in
both application and electrical interfacing of
components and their reaction to each other.
Description
The trainer consists of a mobile support
enclosed frame with mounting panels. The
panels are silkscreened with nomenclature
and graphics identifying each component.
Component connections are brought out to
Hampden HR-1S color coded socket recep-
tacles. The instructor’s fault system consists
of 22 switch injected faults located in a
locked compartment.
All Hampden units are available for operation at any voltage or frequency
071515
P.O. Box 563, East Longmeadow, MA 01028 • Tel 413-525-3981 • Fax 413-525-4741 • E-mail sales@hampden.com 800-253-2133
Series 100 Motor Controllers
E d u c a t i o n a l Tr a i n i n g E q u i p m e n t f o r t h e 2 1 s t C e n t u r y
Experiments
The experiments covered in the Hampden
student Experiment Manual are as follows:
AC Control DC Control
• Full Voltage Starter for a Squirrel Cage • Full Voltage Starter for a Shunt Motor The Hampden MODEL H-REM-ACDC-MC
Motor • Full Voltage Reversing Starter for a Motor Controller requires a variable
• Full Voltage Reversing Starter for a Shunt Motor 0–125VDC 6 ampere source, which is not
Squirrel Cage Motor • Full Voltage Reversing Starter for a provided.
• Full Voltage Starter for a Squirrel Cage Compound Motor
Hampden has the following power supplies
Motor with Overload Protection • Reduced Voltage Starter for a Shunt available:
• Reduced Voltage Resistor Type Starter Motor with Series Current Relay
for a Squirrel-Cage Motor – Two Step Acceleration – Two Step • BPS-103A or BPS-103A-50
• Reduced Voltage Autotransformer Type • Reduced Voltage Starter for a Shunt • BPS-101
Starter for a Squirrel Cage Motor – Two Motor with CEMF Accelerating Relay –
Step Two Step Optional Motors
• Reduced Voltage Reversing Starter for a • Reduced Voltage Starter for a Shunt
Squirrel Cage Motor – Two Step Motor with Definite Time Acceleration – • SM-100-3 Synchronous Machine
• Reduced Voltage Three Step Resistor Two Step • WRM-100-3A Wound Rotor Motor
Type Starter for a Squirrel Cage Motor • Reduced Voltage Starter for a Shunt
Prices are available from your Hampden
• Full Voltage Starter for a Squirrel Cage Motor with Series Current-Relay
Representative.
Motor with Dynamic Braking Acceleration – Three Step
• Two Step Resistor Type Starter for a • Reduced Voltage Starter for a Shunt
Wound Rotor Motor Motor with CEMF Acceleration Relays –
• Two Step Resistor Type Reversing Three Step
Starter for a Wound Rotor Motor • Reduced Voltage Reversing Starter for a
• Three Step Resistor Type Starter for a Shunt Motor with Definite Time
Wound Rotor Motor Acceleration – Two Step
• Full Voltage Starter for a Synchronous • Full Voltage Starter for a Shunt Motor
Motor with Overload Protection
• Reduced Voltage Resistor Type Starter • Full Voltage Starter for a Shunt Motor
for a Synchronous Motor with Field Failure Protection
• Full Voltage Starter for a Synchronous • Full Voltage Starter for a Shunt Motor
Motor with Dynamic Braking with Dynamic Braking
• Full Voltage Starter for a Shunt Motor
with Field Accelerating Relay
• Two Step Reduced Voltage Starter for a
Shunt Motor with Definite Time
Acceleration, Dynamic Braking, Field
Accelerating Relays, Overload and Field
Failure protection
All Hampden units are available for operation at any voltage or frequency