BSC Boards

OMUb GOMU GSM Operation and Maintenance Unit

GCUa GGCU GSM General Clock Unit

SCUa GSCU GSM Switching and Control Unit

TNUa GTNU GSM TDM switching Network Unit

XPUa GXPUM GSM eXtensible Processing Unit for Main service

GXPUT GSM eXtensible Processing Unit for Transmission

EIUa GEIUB GSM E1/T1 Interface Unit for aBis

GEIUP GSM E1/T1 Interface Unit for Pb

GEIUT GSM E1/T1 Interface Unit for aTer

GEIUA GSM E1/T1 Interface Unit for A

OIUa GOIUB GSM Optic Interface Unit for aBis

GOIUP GSM Optic Interface Unit for Pb

GOIUT GSM Optic Interface Unit for aTer

GOIUA GSM Optic Interface Unit for A

FG2a GFGUA GSM Fast ethernet and Gigabit ethernet Unit for A

GFGUB GSM Fast ethernet and Gigabit ethernet Unit for aBis

GFGUG GSM Fast ethernet and Gigabit ethernet Unit for Gb

GOUa GOGUA GSM Optic Gigabit ethernet Unit for A

GOGUB GSM Optic Gigabit ethernet Unit for aBis

PEUa GEHUB GSM E1/T1 High level Data Link Control Unit for aBis

GEPUG GSM E1/T1 Packet Unit for Gb

PEUb GEXUB GSM electronic interface eXtensible Unit for aBis

POUb GOXUB GSM Optic interface eXtensible Unit for aBis

DPUc GDPUX GSM Data Processing Unit for eXtensible service

DPUd GDPUP GSM Data Processing Unit for PS service

DPUa GDPUC GSM Data Processing Unit for CS service

- PFPU Fan Power Unit

- PFCU Fan Control Unit

- MDMC Distribution Monitor and Communication board

- WOPB Overvoltage Protection Board


 Le GSCU est l'unité de commutation et de commande de GM/M. Il est installé
dans les fentes 6-7 dans le GMPS/GEPS/GTCS. Le GSCU est configuré dans les paires et
le travail en mode d'active/standby.
Les fonctions du GSCU
Le GSCU plateforme fournit d'OM et de GE commutation pour le subrack où elle est localisée.

 Fonctions du GSCU


Le GSCU plateforme fournit d'OM et de GE commutation pour le subrack où il est localisé.
Le GSCU exécute les fonctions suivantes :
l maintient et contrôle le subrack où le GSCU est localisé l fournit une plateforme de
commutation de GE pour les conseils situés dans le subrack il fournit des informations
d'horloge pour les conseils (à l'exclusion du GGCU, du GXPUT, et du GXPUM) dans le subrack

 GTNU
Le GTNU est l'unité de réseau de commutation de GM/M TDM dans BSC. Il est installé dans
les fentes 4-5 dans le GMPS/GEPS/GTCS. Le GTNU est configuré dans les paires et le travail en
mode d'active/standby.
Fonctions du GTNU que Le GTNU sert de centre de commutation aux services de CS du
système entier.
Le GTNU sert de centre de commutation aux services de CS du système entier.
Le GTNU exécute les fonctions suivantes :
l fournit la commutation l de 128Kx128K TDM alloue des ressources de réseau de TDM, et a
installé et libère des raccordements de réseau

 GDPUC
Le GDPUC est l'unité de traitement de service de CS dans BSC. Quand des tableaux de
l'interface E1/T1 sont installés dans le GTCS, le GDPUC peut être installé dans les fentes 9 à
13.Quand des tableaux de l'interface Stm-1 sont installés dans le GTCS, le GDPUC peut être
installé dans les fentes 1 à 3 et les fentes 8 à 13.
Les fonctions du GDPUC(DPUa) Le GDPUC traite des services de voix et des services de
données.
Le panneau de GDPUC(DPUa) les composants sur le panneau de GDPUC sont les LED.
Le GDPUC traite des services de voix et des services de données.
Le GDPUC exécute les fonctions suivantes :? il code et décode des signaux de voix que il fournit
l'adaptation l de taux de service de données fournit des fonctions libres de l'opération de
tandem (TFO) quand appeler et l'utilisation appelée de MSs un code de voix, les signaux de
voix sont codés seulement une fois à la MME. de commencement et décodé seulement une
fois à la MME. de terminaison ceci réduit le codage répété et le décodage et améliore la qualité
des services de la parole. Il fournit la fonction l de perfectionnement de voix détecte des
défauts de voix automatiquement

 Le GDPUX est l'unité informatique de GM/M pour des services extensibles. Il
peut être installé dans les fentes 8-11 dans le GMPS ;fentes 0-3, 8-13, et 14-27 dans le
GEPS ;et fentes 0-3, 8-13 dans le GTCS.
Les fonctions du GDPUX(DPUc) Le GDPUX traite des services de voix et des services de
données.
Le panneau de GDPUX(DPUc) les composants sur le panneau de GDPUX sont les LED.
Le GDPUX traite des services de voix et des services de données.
Le GDPUX hérite de toutes les fonctions du GDPUC.Il exécute les fonctions suivantes :
IL fournit la conversion de format pour 3740 chemins de la parole d'IP et chemins optimisés
par HDLC de la parole comme le expédition de données que Le GDPUX dans le GMPS/GEPS
exécute la fonction a mentionné ci-dessus en n'importe lequel des modes suivants de
configuration :BM/TC combiné, IP fini de A et IP fini d'Abis, ou IP fini et Abis HDLC fini l de A
code et décode les signaux transmis au-dessus d'un maximum de 960 chemins de la parole
que Le GDPUX dans le GMPS/GEPS exécute la fonction a mentionné ci-dessus en n'importe
lequel des modes suivants de configuration :BM/TC a combiné, ou IP fini et Abis TDM fini de
A.Le GDPUX dans le GTCS exécute la fonction mentionnée ci-dessus dans le mode de
configuration séparé par BM/TC.l fournit la fonction libre de l'opération de tandem (TFO)
quand appeler et l'utilisation appelée de MSs un code de voix, les signaux de voix sont codés
seulement une fois à la MME. de commencement et décodé seulement une fois à la MME. de
terminaison ceci réduit le codage répété et le décodage et améliore la qualité des services de
la parole.l fournit la fonction l de perfectionnement de voix détecte des défauts de voix
automatiquement

 Le GDPUP est l'unité informatique de GM/M pour des services de


picoseconde.Il peut être installé dans les fentes 8-13 dans le GMPS/GEPS.
Les fonctions du GDPUP(DPUd) Le GDPUP traite les services de paquet pour BSC.
Le panneau de GDPUP(DPUd) le conseil de GDPUP a seulement des LED sur son panneau.
Le GDPUP traite les services de paquet pour BSC.
Le GDPUP exécute les fonctions suivantes :
le lieutenant traite les services de paquet sur jusqu'à 1.024 simultanément PDCHs actifs où
des signaux sont codés dans MCS9 l liens de paquet de processus que l détecte le panneau
des défauts automatiquement 9.26.2 GDPUP(DPUd) de paquet

 Le GDPUC est l'unité de traitement de service de CS dans BSC. Quand des
tableaux de l'interface E1/T1 sont installés dans le GTCS, le GDPUC peut être installé
dans les fentes 9 à 13.Quand des tableaux de l'interface Stm-1 sont installés dans le
GTCS, le GDPUC peut être installé dans les fentes 1 à 3 et les fentes 8 à 13.
Les fonctions du GDPUC(DPUa) Le GDPUC traite des services de voix et des services de
données.
Le GDPUC traite des services de voix et des services de données.
Le GDPUC exécute les fonctions suivantes :? il code et décode des signaux de voix que l fournit
l'adaptation l de taux de service de données fournit des fonctions libres de l'opération de
tandem (TFO) quand appeler et l'utilisation appelée de MSs un code de voix, les signaux de
voix sont codés seulement une fois à la MME. de commencement et décodé seulement une
fois à la MME. de terminaison ceci réduit le codage répété et le décodage et améliore la qualité
des services de la parole.l fournit la fonction l de perfectionnement de voix détecte des
défauts de voix automatiquement
 Le GDPUX est l'unité informatique de GM/M pour des services extensibles. Il
peut être installé dans les fentes 8-11 dans le GMPS ;fentes 0-3, 8-13, et 14-27 dans le
GEPS ;et fentes 0-3, 8-13 dans le GTCS.
Les fonctions du GDPUX(DPUc) Le GDPUX traite des services de voix et des services de
données.
Le GDPUX traite des services de voix et des services de données.
Le GDPUX hérite de toutes les fonctions du GDPUC. Il exécute les fonctions suivantes :
le lieutenant fournit la conversion de format pour 3740 chemins de la parole d'IP et chemins
optimisés par HDLC de la parole comme le expédition de données que Le GDPUX dans le
GMPS/GEPS exécute la fonction a mentionné ci-dessus en n'importe lequel des modes
suivants de configuration :BM/TC combiné, IP fini de A et IP fini d'Abis, ou IP fini et Abis HDLC
fini l de A code et décode les signaux transmis au-dessus d'un maximum de 960 chemins de la
parole que Le GDPUX dans le GMPS/GEPS exécute la fonction a mentionné ci-dessus en
n'importe lequel des modes suivants de configuration :BM/TC a combiné, ou IP fini et Abis
TDM fini de A. Le GDPUX dans le GTCS exécute la fonction mentionnée ci-dessus dans le mode
de configuration séparé par BM/TC. Il fournit la fonction libre de l'opération de tandem (TFO)
quand appeler et l'utilisation appelée de MSs un code de voix, les signaux de voix sont codés
seulement une fois à la MME. de commencement et décodé seulement une fois à la MME. de
terminaison ceci réduit le codage répété et le décodage et améliore la qualité des services de
la parole. Il fournit la fonction l de perfectionnement de voix détecte des défauts de voix
automatiquement

 Le GDPUP est l'unité informatique de GM/M pour des services de picoseconde.
Il peut être installé dans les fentes 8-13 dans le GMPS/GEPS.
Les fonctions du GDPUP(DPUd) Le GDPUP traite les services de paquet pour BSC.
Le GDPUP traite les services de paquet pour BSC.
Le GDPUP exécute les fonctions suivantes :
le lieutenant traite les services de paquet sur jusqu'à 1.024 simultanément PDCHs actifs où
des signaux sont codés dans MCS9 l liens de paquet de processus que l détecte des défauts de
paquet automatiquement

 Le MDMC est la puissance surveillant la carte de communication pour la boîte


commune de distribution d'énergie de BSC. Il est configuré dans la boîte de distribution
d'énergie au-dessus du GBCR/GBSR. chaque boîte de distribution d'énergie devrait
être configurée avec un MDMC.
Des fonctions du MDMC Le MDMC est employées pour surveiller la boîte de distribution
d'énergie de BSC.
Le panneau de MDMC les composants sur le MDMC sont les LED et le commutateur muet.
Le MDMC est employé pour surveiller la boîte de distribution d'énergie de BSC.
Le MDMC exécute les fonctions suivantes :
le lieutenant détecte deux -48 entrées de V que il détecte des signaux d'une sonde de
température externe il détecte des signaux d'une sonde externe l d'humidité détecte des
signaux de deux dispositifs de protection contre la foudre l détecte le statut de six
commutateurs de rendement de puissance l produit et rapporte audible et les alarmes l de
visuel communique avec le GSCU, rapporte le statut de la boîte de distribution d'énergie, et
échange l'information d'OM avec le GSCU

 The GSCU is the GSM Switching and Control Unit. It is installed in slots 6-7 in the GMPS/
GEPS/GTCS. The GSCU is configured in pairs and work in active/standby mode.
Functions of the GSCU The GSCU provides an OM and GE switching platform for the subrack
where it is located.
 Functions of the GSCU
The GSCU provides an OM and GE switching platform for the subrack where it is located.
The GSCU performs the following functions:
l Maintains and manages the subrack where the GSCU is located l Provides a GE switching
platform for the boards located in the subrack l Provides clock information for the boards
(excluding the GGCU, GXPUT, and GXPUM) in the subrack

 GTNU
The GTNU is the GSM TDM switching network unit in the BSC. It is installed in slots 4-5 in the
GMPS/GEPS/GTCS. The GTNU is configured in pairs and work in active/standby mode.
Functions of the GTNU The GTNU serves as the switching center for the CS services of the
entire system.
The GTNU serves as the switching center for the CS services of the entire system.
The GTNU performs the following functions:
l Provides 128Kx128K TDM switching l Allocates TDM network resources, and sets up and
releases network connections

 GDPUC
The GDPUC is the CS service processing unit in the BSC. When E1/T1 interface boards are
installed in the GTCS, the GDPUC can be installed in slots 9 to 13. When STM-1 interface boards
are installed in the GTCS, the GDPUC can be installed in slots 1 to 3 and slots 8 to 13.
Functions of the GDPUC(DPUa) The GDPUC processes voice services and data services.
GDPUC(DPUa) Panel The components on the GDPUC panel are the LEDs.
The GDPUC processes voice services and data services.
The GDPUC performs the following functions: l Encodes and decodes voice signals l Provides
data service rate adaptation l Provides Tandem Free Operation (TFO) functions When the
calling and called MSs use one voice coding scheme, the voice signals are encoded only once
at the originating MS and decoded only once at the terminating MS. This reduces repeated
encoding and decoding and improves the quality of speech services. l Provides voice
enhancement function l Detects voice faults automatically

 The GDPUX is the GSM Data Processing Unit for eXtensible services. It can be installed
in slots 8–11 in the GMPS; slots 0–3, 8–13, and 14–27 in the GEPS; and slots 0–3, 8–13
in the GTCS.
Functions of the GDPUX(DPUc) The GDPUX processes voice services and data services.
GDPUX(DPUc) Panel The components on the GDPUX panel are the LEDs.
The GDPUX processes voice services and data services.
The GDPUX inherits all the functions of the GDPUC. It performs the following functions:
IT Provides format conversion for 3740 IP speech paths and HDLC optimized speech paths as
well as data forwarding The GDPUX in the GMPS/GEPS performs the function mentioned
above in any of the following configuration modes: BM/TC combined, A over IP and Abis over
IP, or A over IP and Abis over HDLC. l Encodes and decodes the signals transmitted over a
maximum of 960 speech paths The GDPUX in the GMPS/GEPS performs the function
mentioned above in any of the following configuration modes: BM/TC combined, or A over IP
and Abis over TDM. The GDPUX in the GTCS performs the function mentioned above in the
BM/TC separated configuration mode. l Provides Tandem Free Operation (TFO) function
When the calling and called MSs use one voice coding scheme, the voice signals are encoded
only once at the originating MS and decoded only once at the terminating MS. This reduces
repeated encoding and decoding and improves the quality of speech services. l Provides voice
enhancement function l Detects voice faults automatically

 The GDPUP is the GSM Data Processing Unit for PS services. It can be installed in slots
8–13 in the GMPS/GEPS.
Functions of the GDPUP(DPUd) The GDPUP processes the packet services for the BSC.
GDPUP(DPUd) Panel The GDPUP board has only LEDs on its panel.
The GDPUP processes the packet services for the BSC.
The GDPUP performs the following functions:
lT Processes the packet services on up to 1,024 simultaneously active PDCHs where signals are
coded in MCS9 l Processes packet links l Detects packet faults automatically 9.26.2
GDPUP(DPUd) Panel

 The GDPUC is the CS service processing unit in the BSC. When E1/T1 interface boards
are installed in the GTCS, the GDPUC can be installed in slots 9 to 13. When STM-1
interface boards are installed in the GTCS, the GDPUC can be installed in slots 1 to 3
and slots 8 to 13.
Functions of the GDPUC(DPUa) The GDPUC processes voice services and data services.
The GDPUC processes voice services and data services.
The GDPUC performs the following functions: l Encodes and decodes voice signals l Provides
data service rate adaptation l Provides Tandem Free Operation (TFO) functions When the
calling and called MSs use one voice coding scheme, the voice signals are encoded only once
at the originating MS and decoded only once at the terminating MS. This reduces repeated
encoding and decoding and improves the quality of speech services. l Provides voice
enhancement function l Detects voice faults automatically

 The GDPUX is the GSM Data Processing Unit for eXtensible services. It can be installed
in slots 8–11 in the GMPS; slots 0–3, 8–13, and 14–27 in the GEPS; and slots 0–3, 8–13
in the GTCS.
Functions of the GDPUX(DPUc) The GDPUX processes voice services and data services.
The GDPUX processes voice services and data services.
The GDPUX inherits all the functions of the GDPUC. It performs the following functions:
lt Provides format conversion for 3740 IP speech paths and HDLC optimized speech paths as
well as data forwarding The GDPUX in the GMPS/GEPS performs the function mentioned
above in any of the following configuration modes: BM/TC combined, A over IP and Abis over
IP, or A over IP and Abis over HDLC. l Encodes and decodes the signals transmitted over a
maximum of 960 speech paths The GDPUX in the GMPS/GEPS performs the function
mentioned above in any of the following configuration modes: BM/TC combined, or A over IP
and Abis over TDM. The GDPUX in the GTCS performs the function mentioned above in the
BM/TC separated configuration mode. l Provides Tandem Free Operation (TFO) function
When the calling and called MSs use one voice coding scheme, the voice signals are encoded
only once at the originating MS and decoded only once at the terminating MS. This reduces
repeated encoding and decoding and improves the quality of speech services. l Provides voice
enhancement function l Detects voice faults automatically
 The GDPUP is the GSM Data Processing Unit for PS services. It can be installed in slots
8–13 in the GMPS/GEPS.
Functions of the GDPUP(DPUd) The GDPUP processes the packet services for the BSC.
The GDPUP processes the packet services for the BSC.
The GDPUP performs the following functions:
lt Processes the packet services on up to 1,024 simultaneously active PDCHs where signals are
coded in MCS9 l Processes packet links l Detects packet faults automatically

 The MDMC is the power monitoring communication board for the BSC common power
distribution box. It is configured in the power distribution box at the top of the
GBCR/GBSR. Each power distribution box should be configured with one MDMC.
Functions of the MDMC The MDMC is used to monitor the BSC power distribution box.
MDMC Panel The components on the MDMC are the LEDs and mute switch.
The MDMC is used to monitor the BSC power distribution box.
The MDMC performs the following functions:
lt Detects two –48 V inputs l Detects signals from one external temperature sensor l Detects
signals from one external humidity sensor l Detects signals from two lightning protection
devices l Detects the status of six power output switches l Generates and reports audible and
visual alarms l Communicates with the GSCU, reports the status of the power distribution box,
and exchanges the OM information with the GSCU
Panel EIUa
GEIUA The GEIUA is the GSM E1/T1 Interface Unit for the A interface. It can be installed in slots 18-
25 in the GMPS/GEPS/GTCS. The GEIUA can be configured in pairs and work in active/ standby mode.

GEIUB The GEIUB is the GSM E1/T1 Interface Unit for the Abis interface. It can be installed in slots 18-
27 in the GMPS/GEPS. The GEIUB can be configured in pairs and work in active/standby mode.

GEIUP The GEIUP is the GSM E1/T1 Interface Unit for the Pb interface. It can be installed in slots 14-
15 in the GMPS/GEPS. The GEIUP can be configured in pairs and work in active/standby mode.

GEIUT The GEIUT is the GSM E1/T1 Interface Unit for the Ater interface. It can be installed in slots 16-
17 in the GMPS/GEPS and in slots 14-17 in the GTCS. The GEIUT can be configured in pairs and work in
active/standby mode.

Panel PEUa
GEHUB The GEHUB is the GSM E1/T1 High level Data Link Control Unit for the Abis interface. It can be
installed in slots 18–27 in the GMPS/GEPS. When the BSC need not process packet services, the GEHUB
can also be installed in slots 14–15. The GEHUB can work in active/standby mode and work
independently.

The GEPUG is the GSM E1/T1 Packet Unit for the Gb interface. It can be installed in slots 14– 15 in the
GMPS/GEPS. The GEPUG can work in active/standby mode and work independently.

Panel PEUb
GEXUB The GEXUB is the GSM electronic interface extensible Unit for TDM over E1/T1 and HDLC over
E1/T1 on the Abis interface. It can be installed in slots 18–27 in the GMPS/GEPS. When the BSC need
not process packet services, the GEXUB can also be installed in slots 14–15. The GEXUB can work in
active/standby mode and work independently.

GOMU This describes the GSM Operation and Maintenance Unit (GOMU). It serves as the server in
the BSC. The GOMUs are installed in slots 20–23 in the GMPS and work in active/standby mode.
 The GEIUA is the GSM E1/T1 Interface Unit for the A interface. It can be installed in slots 18-
25 in the GMPS/GEPS/GTCS. The GEIUA can be configured in pairs and work in active/ standby
mode.

Functions of the GEIUA The GEIUA enables the E1/T1 transmission on the A interface.

GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT
are the same. After being loaded with different software, the physical boards perform different
functions. These boards have the same appearance and the same LEDs and ports.

LEDs on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same types of LEDs on the panels: RUN, ALM, and ACT.

Ports on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same ports. Of the seven ports, four ports are labeled E1/T1,
one 2MO, one 2M1, and one TESTOUT.

DIP Switches on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa) The physical boards of the GEIUA, GEIUB,
GEIUP, and GEIUT are the same. After being loaded with different software, the physical boards
perform different functions. They have the same types of DIP switches: S1, S3, S4, S5, and S6. 9.1.1
Functions of the GEIUA

 The GEIUA enables the E1/T1 transmission on the A interface.

The GEIUA performs the following functions:

l Provides four E1/T1 electrical ports, which is used for TDM transmission l Provides Tributary Protect
Switch (TPS) function to enable switchover between the physical links of the active and standby boards.
l Transmits and receives 32 E1/T1 signals, and encodes and decodes the E1/T1 signals (The E1
transmission rate is 2.048 Mbit/s and the T1 transmission rate is 1.544 Mbit/s.) 9.1.2
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel

The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT are the same. After being loaded with
different software, the physical boards perform different functions. These boards have the same
appearance and the same LEDs and ports.

 The GEIUB is the GSM E1/T1 Interface Unit for the Abis interface. It can be installed in slots 18-
27 in the GMPS/GEPS. The GEIUB can be configured in pairs and work in active/standby mode.

Functions of the GEIUB The GEIUB enables the E1/T1 transmission on the Abis interface.

GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT
are the same. After being loaded with different software, the physical boards perform different
functions. These boards have the same appearance and the same LEDs and ports.

LEDs on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same types of LEDs on the panels: RUN, ALM, and ACT.
Ports on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same ports. Of the seven ports, four ports are labeled E1/T1,
one 2MO, one 2M1, and one TESTOUT.

DIP Switches on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa)

The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT are the same. After being loaded with
different software, the physical boards perform different functions. They have the same types of DIP
switches: S1, S3, S4, S5, and S6. 9.2.1 Functions of the GEIUB

 The GEIUB enables the E1/T1 transmission on the Abis interface.

The GEIUB performs the following functions:

l Provides four E1/T1 electrical ports, which is used for TDM transmission l Provides Tributary Protect
Switch (TPS) function to enable switchover between the physical links of the active and standby boards.
l Transmits and receives 32 E1/T1 signals, and encodes and decodes the E1/T1 signals (The E1
transmission rate is 2.048 Mbit/s and the T1 transmission rate is 1.544 Mbit/s.) 9.2.2
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel

The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT are the same. After being loaded with
different software, the physical boards perform different functions. These boards have the same
appearance and the same LEDs and ports.

 The GEIUP is the GSM E1/T1 Interface Unit for the Pb interface. It can be installed in slots 14-
15 in the GMPS/GEPS. The GEIUP can be configured in pairs and work in active/standby mode.

Functions of the GEIUP The GEIUP enables the E1/T1 transmission on the Pb interface.

GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT
are the same. After being loaded with different software, the physical boards perform different
functions. These boards have the same appearance and the same LEDs and ports.

LEDs on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same types of LEDs on the panels: RUN, ALM, and ACT.

Ports on the GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel The physical boards of the GEIUA, GEIUB, GEIUP,
and GEIUT are the same. After being loaded with different software, the physical boards perform
different functions. These boards have the same ports. Of the seven ports, four ports are labeled E1/T1,
one 2MO, one 2M1, and one TESTOUT.

The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT are the same. After being loaded with
different software, the physical boards perform different functions. They have the same types of DIP
switches: S1, S3, S4, S5, and S6. 9.3.1 Functions of the GEIUP

 The GEIUP enables the E1/T1 transmission on the Pb interface.

The GEIUP performs the following functions:


l Provides four E1/T1 electrical ports, which is used for TDM transmission l Provides Tributary Protect
Switch (TPS) function to enable switchover between the physical links of the active and standby boards.
l Transmits and receives 32 E1/T1 signals, and encodes and decodes the E1/T1 signals (The E1
transmission rate is 2.048 Mbit/s and the T1 transmission rate is 1.544 Mbit/s.) l Processes signals
according to the Link Access Procedure on the D channel (LAPD) protocol 9.3.2
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panel

The physical boards of the GEIUA, GEIUB, GEIUP, and GEIUT are the same. After being loaded with
different software, the physical boards perform different functions. These boards have the same
appearance and the same LEDs and ports.

 The GEHUB is the GSM E1/T1 High level Data Link Control Unit for the Abis interface. It can
be installed in slots 18–27 in the GMPS/GEPS. When the BSC need not process packet services,
the GEHUB can also be installed in slots 14–15. The GEHUB can work in active/standby mode
and work independently.

Functions of the GEHUB The GEHUB enables the E1/T1 transmission on the Abis interface.

GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same. After being
loaded with different software, the physical boards perform different functions. These boards have
the same appearance and the same LEDs and ports. 9.20.3 LEDs on the GEHUB/GEPUG(PEUa) Panel
The physical boards of the GEHUB and GEPUG are the same. After being loaded with different
software, the physical boards perform different functions. These boards have the same types of LEDs
on the panels: RUN, ALM, and ACT. 9.20.4 Ports on the GEHUB/GEPUG(PEUa) Panel The physical
boards of the GEHUB and GEPUG are the same. After being loaded with different software, the physical
boards perform different functions. These boards have the same ports. Of the six ports, four ports are
labeled E1/T1, one 2MO, and one 2M1. 9.20.5 DIP Switches on the GEHUB/GEPUG(PEUa) The physical
boards of the GEHUB and GEPUG are the same. After being loaded with different software, the physical
boards perform different functions. They have the same types of DIP switches: S2, S4, S6, S8, and S10.

Functions of the GEHUB

The GEHUB enables the E1/T1 transmission on the Abis interface.

The GEHUB performs the following functions:

l Provides four E1/T1 electrical ports, which are used for HDLC/Hub BTS transmission l Provides
Tributary Protect Switch (TPS) function to enable switchover between the physical links of the active
and standby boards. l Transmits and receives 32 E1/T1 signals, and encodes and decodes the E1/T1
signals (The E1 transmission rate is 2.048 Mbit/s and the T1 transmission rate is 1.544 Mbit/s.) 9.20.2
GEHUB/GEPUG(PEUa) Panel

The physical boards of the GEHUB and GEPUG are the same. After being loaded with different
software, the physical boards perform different functions. These boards have the same appearance
and the same LEDs and ports.

 The GEPUG is the GSM E1/T1 Packet Unit for the Gb interface. It can be installed in slots 14–
15 in the GMPS/GEPS. The GEPUG can work in active/standby mode and work independently.

Functions of the GEPUG The GEPUG enables the E1/T1 transmission on the Pb interface.
GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same. After being
loaded with different software, the physical boards perform different functions. These boards have
the same appearance and the same LEDs and ports.

LEDs on the GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same.
After being loaded with different software, the physical boards perform different functions. These
boards have the same types of LEDs on the panels: RUN, ALM, and ACT.

Ports on the GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same.
After being loaded with different software, the physical boards perform different functions. These
boards have the same ports. Of the six ports, four ports are labeled E1/T1, one 2MO, and one 2M1.

DIP Switches on the GEHUB/GEPUG(PEUa) The physical boards of the GEHUB and GEPUG are the same.
After being loaded with different software, the physical boards perform different functions. They have
the same types of DIP switches: S2, S4, S6, S8, and S10. 9.21.1 Functions of the GEPUG

The GEPUG enables the E1/T1 transmission on the Pb interface.

The GEPUG performs the following functions:

l Provides four E1/T1 electrical ports, which are used for FR transmission l Provides Tributary Protect
Switch (TPS) function to enable switchover between the physical links of the active and standby boards.
l Transmits and receives 32 E1/T1 signals, and encodes and decodes the E1/T1 signals (The E1
transmission rate is 2.048 Mbit/s and the T1 transmission rate is 1.544 Mbit/s.) 9.21.2
GEHUB/GEPUG(PEUa) Panel

The physical boards of the GEHUB and GEPUG are the same. After being loaded with different
software, the physical boards perform different functions. These boards have the same appearance
and the same LEDs and ports.

 The GEXUB is the GSM electronic interface extensible Unit for TDM over E1/T1 and HDLC over
E1/T1 on the Abis interface. It can be installed in slots 18–27 in the GMPS/GEPS. When the BSC
need not process packet services, the GEXUB can also be installed in slots 14–15. The GEXUB
can work in active/standby mode and work independently.

Functions of the GEXUB The GEXUB enables the E1/T1 transmission on the Abis interface.

GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same. After being
loaded with different software, the physical boards perform different functions. These boards have
the same appearance and the same LEDs and ports.

LEDs on the GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same.
After being loaded with different software, the physical boards perform different functions. These
boards have the same types of LEDs on the panels: RUN, ALM, and ACT.

Ports on the GEHUB/GEPUG(PEUa) Panel The physical boards of the GEHUB and GEPUG are the same.
After being loaded with different software, the physical boards perform different functions. These
boards have the same ports. Of the six ports, four ports are labeled E1/T1, one 2MO, and one 2M1.

GOMU
This describes the GSM Operation and Maintenance Unit (GOMU). It serves as the server in the BSC.
The GOMUs are installed in slots 20–23 in the GMPS and work in active/standby mode.

As the OM center of the BSC, the GOMU enables the communication between the LMT and the other
boards in the BSC. The GOMU features high computation speed and outstanding data processing
capability.

GOMU Panel The components on the GOMU panel are the LEDs and ports.

LEDs on the GOMU Panel There are five LEDs on the GOMU panel: RUN, ALM, ACT, OFFLINE, and HD.

4 Ports on the GOMU Panel The ports on the GOMU panel consist of four USB ports (labeled USB0-1
and USB2-3), three GE ports (labeled ETH0, ETH1, and ETH2), one serial port COM-ALM/COM-BMC,
and one VGA port.

Functions of the GOMU

As the OM center of the BSC, the GOMU enables the communication between the LMT and the other
boards in the BSC. The GOMU features high computation speed and outstanding data processing
capability.

The GOMU performs the following functions:

l Controls the communication between the LMT computer and the other boards in the BSC, facilitates
the data configuration, and collects and filters the performance and alarm data l Processes the
commands issued by the LMT computer/M2000, and then forwards the commands to the other boards
in the BSC for processing l Filters the results from the other boards in the BSC, and then returns the
results to the LMT computer 9.10.2 GOMU Panel.

 Configuration of the BSC Subrack


The BSC subracks are classified into the GMPS, GEPS, and GTCS. This describes the recommended
configurations of these subracks in different application scenarios and combination modes.

8.5.1 Configuration of the GMPS (Configuration Type A) The GMPS is configured in the GBCR. Each BSC
must be configured with one GMPS. The GMPS processes the basic services of the BSC, performs
operation and maintenance, and provides clock signals for the system. The configuration of the boards
in the GMPS varies with the configuration modes of the BSC subracks. 8.5.2 Configuration of the GMPS
(Configuration Type B) The GMPS is configured in the GBCR. Each BSC must be configured with one
GMPS. The GMPS processes the basic services of the BSC, performs operation and maintenance, and
provides clock signals for the system. The configuration of the boards in the GMPS varies with the
configuration modes of the BSC subracks. 8.5.3 Configuration of the GEPS The GEPS is configured in
the GBCR or GBSR. The BSC can be configured with zero to three GEPSs. The GEPS processes the basic
services of the BSC. The configuration of the boards in the GEPS varies with the configuration modes
of the BSC subracks. 8.5.4 Configuration of the GTCS In BM/TC separated configuration mode, the GTCS
is configured in the GBCR or GBSR. The BSC can be configured with zero to four GTCSs. The GTCS
performs transcoding, rate adaptation, and sub-multiplexing.

 Configuration of the GMPS (Configuration Type A)


The GMPS is configured in the GBCR. Each BSC must be configured with one GMPS. The GMPS
processes the basic services of the BSC, performs operation and maintenance, and provides clock
signals for the system. The configuration of the boards in the GMPS varies with the configuration
modes of the BSC subracks.

 BM/TC Separated (Built-In PCU)

In BM/TC separated (built-in PCU) configuration mode, the GMPS must be configured with the GTNU,
GSCU, GGCU, GXPUM, GDPUP, and GEPUG/GFGUG. The GDPUX, GXPUT,
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUT/GOIUT are optional boards.

 BM/TC Separated (External PCU)

In BM/TC separated (external PCU) configuration mode, the GMPS must be configured with the GTNU,
GSCU, GGCU, and GXPUM. The GXPUT, GEIUB/GOIUB/GEHUB/GFGUB/ GOGUB/GEXUB/GOXUB,
GEIUP/GOIUP, and GEIUT/GOIUT are optional boards.

 BM/TC Combined (Built-In PCU)

In BM/TC combined (built-in PCU) configuration mode, the GMPS must be configured with the GTNU,
GSCU, GGCU, GXPUM, GDPUX, GDPUP, and GEPUG/GFGUG. The GXPUT, GEIUA/GOIUA, and
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB are optional boards.

 BM/TC Combined (External PCU)

In BM/TC combined (external PCU) configuration mode, the GMPS must be configured with the GTNU,
GSCU, GGCU, GXPUM, and GDPUX. The GXPUT, GEIUA/GOIUA, GEIUB/
GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional boards.

 A over IP (Built-In PCU)

In A over IP (built-in PCU) configuration mode, the GMPS must be configured with the GTNU, GSCU,
GGCU, GXPUM, GDPUX, GDPUP, GEPUG/GFGUG, and GFGUA/GOGUA. The GXPUT and
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB are optional boards.

 A over IP (External PCU)

In A over IP (external PCU) configuration mode, the GMPS must be configured with the GTNU, GSCU,
GGCU, GXPUM, GDPUX, and GFGUA/GOGUA. The GXPUT, GEIUB/GOIUB/
GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional boards.
 The GMPS is configured in the GBCR. Each BSC must be configured with one GMPS. The GMPS
processes the basic services of the BSC, performs operation and maintenance, and provides
clock signals for the system. The configuration of the boards in the GMPS varies with the
configuration modes of the BSC subracks.

 BM/TC Separated (Built-In PCU)

In BM/TC separated (built-in PCU) configuration mode, the GMPS must be configured with the GOMU,
GTNU, GSCU, GGCU, GXPUM, GDPUP, and GEPUG/GFGUG. The GDPUX, GXPUT,
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUT/GOIUT are optional boards.

 BM/TC Combined (Built-In PCU)

In BM/TC combined (built-in PCU) configuration mode, the GMPS must be configured with the GOMU,
GTNU, GSCU, GGCU, GXPUM, GDPUX, GDPUP, and GEPUG/GFGUG. The GXPUT, GEIUA/GOIUA, and
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB are optional boards.

 BM/TC Combined (External PCU)

In BM/TC combined (external PCU) configuration mode, the GMPS must be configured with the GOMU,
GTNU, GSCU, GGCU, GXPUM, and GDPUX. The GXPUT, GEIUA/GOIUA,
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional boards.

 A over IP (External PCU)

In A over IP (external PCU) configuration mode, the GMPS must be configured with the GTNU, GSCU,
GGCU, GXPUM, GDPUX, and GFGUA/GOGUA. The GXPUT, GEIUB/GOIUB/
GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional boards.

The GEPS is configured in the GBCR or GBSR. The BSC can be configured with zero to three GEPSs. The
GEPS processes the basic services of the BSC. The configuration of the boards in the GEPS varies with
the configuration modes of the BSC subracks.

BM/TC Separated (Built-In PCU)

In BM/TC separated (built-in PCU) configuration mode, the GEPS must be configured with the GTNU,
GSCU, GXPUM, GDPUP, and GEPUG/GFGUG. The GDPUX, GXPUT, GEIUB/
GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUT/GOIUT are optional boards.

 BM/TC Separated (External PCU)

In BM/TC separated (external PCU) configuration mode, the GEPS must be configured with the GTNU,
GSCU, and GXPUM. The GXPUT, GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/ GEXUB/GOXUB,
GEIUP/GOIUP, and GEIUT/GOIUT are optional boards.

 BM/TC Combined (Built-In PCU)

In BM/TC combined (built-in PCU) configuration mode, the GEPS must be configured with the GTNU,
GSCU, GXPUM, GDPUX, GDPUP, and GEPUG/GFGUG. The GXPUT, GEIUA/ GOIUA, and
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB are optional boards.
 BM/TC Combined (External PCU)

In BM/TC combined (external PCU) configuration mode, the GEPS must be configured with the GTNU,
GSCU, GXPUM, and GDPUX. The GXPUT, GEIUA/GOIUA, GEIUB/GOIUB/
GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional boards.

 A over IP (Built-In PCU)

In A over IP (built-in PCU) configuration mode, the GEPS must be configured with the GTNU, GSCU,
GXPUM, GDPUX, GDPUP, GEPUG/GFGUG, and GFGUA/GOGUA. The GXPUT and
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB are optional boards.

 A over IP (External PCU) In A over IP (external PCU) configuration mode, the GEPS must be
configured with the GTNU, GSCU, GXPUM, GDPUX, and GFGUA/GOGUA. The GXPUT,
GEIUB/GOIUB/GEHUB/ GFGUB/GOGUB/GEXUB/GOXUB, and GEIUP/GOIUP are optional
boards.

CAUTION l The GDPUX inherits all the functions of the GDPUC. The GDPUX must be configured in any
of the following conditions: in BM/TC combined configuration mode, in BM/TC separated
configuration mode with the GEHUB/GFGUB/GOGUB/GEXUB/GOXUB configured, or in A over IP
configuration mode. l When the number of TRXs to be supported is greater than 256, a pair of GXPUTs
must be configured in the GEPS. l The A, Abis, Ater, and Pb interfaces support E1/T1, FE/GE, and STM-
1 transmissions. The Gb interface supports E1/T1 and FE/GE transmissions. The previous figures take
E1/T1 transmission as examples, where the GEIUA/GEIUB/GEIUT/GEIUP/GEHUB/GEPUG/ GEXUB is
configured.

For details on the boards in the GEPS, refer to 9 BSC Boards. 8.5.4 Configuration of the GTCS In BM/TC
separated configuration mode, the GTCS is configured in the GBCR or GBSR. The BSC can be configured
with zero to four GTCSs. The GTCS performs transcoding, rate adaptation, and sub-multiplexing.

The GTCS must be configured with the GSCU and GTNU. The GDPUX, GEIUA/GOIUA, and GEIUT/GOIUT
are optional boards.

When the E1/T1 transmission is used on the A interface, one GTCS supports a maximum of 4,800
speech paths. Figure 8-23 shows the fully configured GTCS.

When the STM-1 transmission is used on the A interface, one GTCS supports a maximum of 9,600
speech paths. Figure 8-24 shows the fully configured GTCS.
Conseils de BSC
Opération d'OMUb GOMU GM/M et unité d'entretien

Unité D'Horloge Générale De GCUa GGCU GM/M


Commutation de SCUa GSCU GM/M et unité de commande

Unité de réseau de commutation de TNUa GTNU GM/M TDM

Unité de traitement extensible de XPUa GXPUM GM/M pour le service principal

Unité de traitement extensible de GXPUT GM/M pour la transmission


Unité d'interface d'EIUa GEIUB GM/M E1/T1 pour des aBis
Unité d'interface de GEIUP GM/M E1/T1 pour le Pb

Unité d'interface de GEIUT GM/M E1/T1 pour l'aTer


Unité d'interface de GEIUA GM/M E1/T1 pour A

Unité optique d'interface d'OIUa GOIUB GM/M pour des aBis

Unité optique d'interface de GOIUP GM/M pour le Pb

Unité optique d'interface de GOIUT GM/M pour l'aTer


Unité optique d'interface de GOIUA GM/M pour A

Ethernet rapide de FGà GFGUA GM/M et unité d'Ethernet de gigabit pour A


Ethernet rapide de GFGUB GM/M et unité d'Ethernet de gigabit pour des aBis
Ethernet rapide de GFGUG GM/M et unité d'Ethernet de gigabit pour le gigaoctet

Unité optique d'Ethernet de gigabit de GOUa GOGUA GM/M pour A

Unité optique d'Ethernet de gigabit de GOGUB GM/M pour des aBis


Unité de commande de liaison de transmission de données de niveau élevé de PEUa GEHUB GM/M
E1/T1 pour des aBis

Unité de paquet de GEPUG GM/M E1/T1 pour le gigaoctet


Unité extensible d'interface électronique de PEUb GEXUB GM/M pour des aBis

Unité extensible d'interface optique de POUb GOXUB GM/M pour des aBis
Unité informatique de DPUc GDPUX GM/M pour le service extensible

Unité informatique de DPUd GDPUP GM/M pour le service de picoseconde


Unité informatique de DPUa GDPUC GM/M pour le service de CS
- Unité De puissance De Ventilateur de PFPU

- Unité De Commande De Ventilateur de PFCU

- carte de moniteur et de communication de distribution de MDMC

- Conseil De Protection De Surtension de WOPB

Panneau EIUa

GEIUA Le GEIUA est l'unité d'interface de GM/M E1/T1 pour l'interface de A.Il peut être installé dans
les fentes 18-25 dans le GMPS/GEPS/GTCS.Le GEIUA peut être configuré dans les paires et le travail en
mode 'attente'actif/.
GEIUB Le GEIUB est l'unité d'interface de GM/M E1/T1 pour l'interface d'Abis.Il peut être installé dans
les fentes 18-27 dans le GMPS/GEPS.Le GEIUB peut être configuré dans les paires et le travail en mode
d'active/standby.
GEIUP Le GEIUP est l'unité d'interface de GM/M E1/T1 pour l'interface de Pb.Il peut être installé dans
les fentes 14-15 dans le GMPS/GEPS.Le GEIUP peut être configuré dans les paires et le travail en mode
d'active/standby.
GEIUT Le GEIUT est l'unité d'interface de GM/M E1/T1 pour l'interface d'Ater.Il peut être installé dans
les fentes 16-17 dans le GMPS/GEPS et dans les fentes 14-17 dans le GTCS.Le GEIUT peut être configuré
dans les paires et le travail en mode d'active/standby.

Panneau PEUa
GEHUB Le GEHUB est l'unité de commande de liaison de transmission de données de niveau élevé de
GM/M E1/T1 pour l'interface d'Abis.Il peut être installé dans les fentes 18-27 dans le
GMPS/GEPS.Quand BSC n'a pas besoin des services de processus de paquet, le GEHUB peut également
être installé dans les fentes 14-15.Le GEHUB peut fonctionner en mode et travail d'active/standby
indépendamment.
Le GEPUG est l'unité de paquet de GM/M E1/T1 pour l'interface de gigaoctet.Il peut être installé dans
les fentes 14- 15 dans le GMPS/GEPS.Le GEPUG peut fonctionner en mode et travail d'active/standby
indépendamment.

Panneau PEUb
GEXUB Le GEXUB est l'unité extensible d'interface électronique de GM/M pour TDM E1/T1 fini et
HDLC E1/T1 fini sur l'interface d'Abis.Il peut être installé dans les fentes 18-27 dans le
GMPS/GEPS.Quand BSC n'a pas besoin des services de processus de paquet, le GEXUB peut également
être installé dans les fentes 14-15.Le GEXUB peut fonctionner en mode et travail d'active/standby
indépendamment.
GOMU ceci décrit l'unité d'opération et d'entretien de GM/M (GOMU).Il sert de serveur dans BSC.Le
GOMUs sont installés dans les fentes 20-23 dans le GMPS et travaillent dans le mode d'active/standby.

 Le GEIUA est l'unité d'interface de GM/M E1/T1 pour l'interface de A.Il peut être
installé dans les fentes 18-25 dans le GMPS/GEPS/GTCS.Le GEIUA peut être configuré dans les
paires et le travail en mode 'attente'actif/.
Les fonctions du GEIUA Le GEIUA permet la transmission E1/T1 sur l'interface de A.
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) lambrissent les panneaux physiques du GEIUA, GEIUB, GEIUP, et
GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions.Ces conseils ont le même aspect et les mêmes LED et ports.
Les LED sur le GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel les panneaux physiques du GEIUA, du GEIUB, du
GEIUP, et du GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les conseils
physiques exécutent différentes fonctions.Ces conseils ont les mêmes types de LED sur les panneaux
:COURSE, ALM, et LOI.
Les ports sur GEIUA/GEIUB/GEIUP/GEIUT(EIUa) le panneau les panneaux physiques du GEIUA, du
GEIUB, du GEIUP, et du GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les
conseils physiques exécutent différentes fonctions.Ces conseils ont les mêmes ports.Des sept ports,
quatre ports sont marqués E1/T1, un 2MO, un 2M1, et un TESTOUT.
Les contacts DIP sur GEIUA/GEIUB/GEIUP/GEIUT(EIUa) les panneaux physiques du GEIUA, du GEIUB,
du GEIUP, et du GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les conseils
physiques exécutent différentes fonctions.Ils ont les mêmes types de contacts DIP :S1, S3, S4, S5, et
S6.9.1.1 Fonctions du GEIUA

 Le GEIUA permet la transmission E1/T1 sur l'interface de A.


Le GEIUA exécute les fonctions suivantes :
l fournit quatre ports E1/T1 électriques, qui est employé pour la transmission l de TDM fournit le
tributaire protège la fonction du commutateur (TPS) pour permettre le changement entre les liens
physiques des conseils actifs et de secours.l transmet et reçoit 32 signaux E1/T1, et code et décode les
signaux E1/T1 (le taux de la transmission E1 est 2.048 Mbit/s et le taux de la transmission T1 est 1.544
Mbit/s.)9.1.2 GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panneau
Les panneaux physiques du GEIUA, du GEIUB, du GEIUP, et du GEIUT sont identiques.Après avoir été
chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions.Ces conseils ont
le même aspect et les mêmes LED et ports.

 Le GEIUB est l'unité d'interface de GM/M E1/T1 pour l'interface d'Abis.Il peut être
installé dans les fentes 18-27 dans le GMPS/GEPS.Le GEIUB peut être configuré dans les paires
et le travail en mode d'active/standby.
Les fonctions du GEIUB Le GEIUB permet la transmission E1/T1 sur l'interface d'Abis.
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) lambrissent les panneaux physiques du GEIUA, GEIUB, GEIUP, et
GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions.Ces conseils ont le même aspect et les mêmes LED et ports.
Les LED sur le GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel les panneaux physiques du GEIUA, du GEIUB, du
GEIUP, et du GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les conseils
physiques exécutent différentes fonctions.Ces conseils ont les mêmes types de LED sur les panneaux
:COURSE, ALM, et LOI.
Les ports sur GEIUA/GEIUB/GEIUP/GEIUT(EIUa) le panneau les panneaux physiques du GEIUA, du
GEIUB, du GEIUP, et du GEIUT sont identiques.Après avoir été chargé avec le logiciel différent, les
conseils physiques exécutent différentes fonctions.Ces conseils ont les mêmes ports.Des sept ports,
quatre ports sont marqués E1/T1, un 2MO, un 2M1, et un TESTOUT.

Contacts DIP sur le GEIUA/GEIUB/GEIUP/GEIUT(EIUa)


Les panneaux physiques du GEIUA, du GEIUB, du GEIUP, et du GEIUT sont identiques.Après avoir été
chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions.Ils ont les
mêmes types de contacts DIP :S1, S3, S4, S5, et S6.9.2.1 Fonctions du GEIUB

 Le GEIUB permet la transmission E1/T1 sur l'interface d'Abis.


Le GEIUB exécute les fonctions suivantes :
l fournit quatre ports E1/T1 électriques, qui est employé pour la transmission l de TDM fournit le
tributaire protège la fonction du commutateur (TPS) pour permettre le changement entre les liens
physiques des conseils actifs et de secours.l transmet et reçoit 32 signaux E1/T1, et code et décode les
signaux E1/T1 (le taux de la transmission E1 est 2.048 Mbit/s et le taux de la transmission T1 est 1.544
Mbit/s.)9.2.2 GEIUA/GEIUB/GEIUP/GEIUT(EIUa) Panneau
Les panneaux physiques du GEIUA, du GEIUB, du GEIUP, et du GEIUT sont identiques.Après avoir été
chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions.Ces conseils ont
le même aspect et les mêmes LED et ports.

 Le GEIUP est l'unité d'interface de GM/M E1/T1 pour l'interface de Pb.Il peut être
installé dans les fentes 14-15 dans le GMPS/GEPS.Le GEIUP peut être configuré dans les paires
et le travail en mode d'active/standby.
Les fonctions du GEIUP Le GEIUP permet la transmission E1/T1 sur l'interface de Pb.
GEIUA/GEIUB/GEIUP/GEIUT(EIUa) lambrissent les panneaux physiques du GEIUA, GEIUB, GEIUP, et
GEIUT sont identiques. Après avoir été chargé avec le logiciel différent, les conseils physiques
exécutent différentes fonctions. Ces conseils ont le même aspect et les mêmes LED et ports.
Les LED sur le GEIUA/GEIUB/GEIUP/GEIUT(EIUa)Panel les panneaux physiques du GEIUA, du GEIUB, du
GEIUP, et du GEIUT sont identiques. Après avoir été chargé avec le logiciel différent, les conseils
physiques exécutent différentes fonctions. Ces conseils ont les mêmes types de LED sur les panneaux
:COURSE, ALM, et LOI.

Les ports sur GEIUA/GEIUB/GEIUP/GEIUT(EIUa) le panneau les panneaux physiques du GEIUA, du


GEIUB, du GEIUP, et du GEIUT sont identiques. Après avoir été chargé avec le logiciel différent, les
conseils physiques exécutent différentes fonctions. Ces conseils ont les mêmes ports. Des sept ports,
quatre ports sont marqués E1/T1, un 2MO, un 2M1, et un TESTOUT.
Les panneaux physiques du GEIUA, du GEIUB, du GEIUP, et du GEIUT sont identiques. Après avoir été
chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ils ont les
mêmes types de contacts DIP :S1, S3, S4, S5, et S6.9.3.1 Fonctions du GEIUP

 Le GEIUP permet la transmission E1/T1 sur l'interface de Pb.


Le GEIUP exécute les fonctions suivantes :
l fournit quatre ports E1/T1 électriques, qui est employé pour la transmission l de TDM fournit le
tributaire protège la fonction du commutateur (TPS) pour permettre le changement entre les liens
physiques des conseils actifs et de secours. ll transmet et reçoit 32 signaux E1/T1, et code et décode
les signaux E1/T1 (le taux de la transmission E1 est 2.048 Mbit/s et le taux de la transmission T1 est
1.544 Mbit/s.)l traite des signaux selon le procédé d'accès de lien sur le panneau du protocole 9.3.2 du
canal de D (LAPD) GEIUA/GEIUB/GEIUP/GEIUT(EIUa)
Les panneaux physiques du GEIUA, du GEIUB, du GEIUP, et du GEIUT sont identiques. Après avoir été
chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces conseils
ont le même aspect et les mêmes LED et ports.

 Le GEHUB est l'unité de commande de liaison de transmission de données de niveau


élevé de GM/M E1/T1 pour l'interface d'Abis. Il peut être installé dans les fentes 18-27 dans le
GMPS/GEPS. Quand BSC n'a pas besoin des services de processus de paquet, le GEHUB peut
également être installé dans les fentes 14-15.Le GEHUB peut fonctionner en mode et travail
d'active/standby indépendamment.
Les fonctions du GEHUB Le GEHUB permet la transmission E1/T1 sur l'interface d'Abis.
GEHUB/GEPUG(PEUa) lambrissent les panneaux physiques du GEHUB et GEPUG sont identiques. Après
avoir été chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces
conseils ont le même aspect et les mêmes LED et ports.9.20.3 Les LED sur GEHUB/GEPUG(PEUa) le
panneau les panneaux physiques du GEHUB et du GEPUG sont identiques. Après avoir été chargé avec
le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces conseils ont les mêmes
types de LED sur les panneaux :COURSE, ALM, et LOI.9.20.4 Les ports sur GEHUB/GEPUG(PEUa) le
panneau les panneaux physiques du GEHUB et du GEPUG sont identiques. Après avoir été chargé avec
le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces conseils ont les mêmes
ports. Des six ports, quatre ports sont marqués E1/T1, un 2MO, et un 2M1.9.20.5 Les contacts DIP sur
GEHUB/GEPUG(PEUa) les panneaux physiques du GEHUB et du GEPUG sont identiques. Après avoir
été chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ils ont les
mêmes types de contacts DIP :S2, S4, S6, S8, et S10.

Fonctions du GEHUB

Le GEHUB permet la transmission E1/T1 sur l'interface d'Abis.


Le GEHUB exécute les fonctions suivantes :
l fournit quatre ports E1/T1 électriques, qui sont employés pour la transmission l de HDLC/Hub BTS
fournissent le tributaire protègent la fonction du commutateur (TPS) pour permettre le changement
entre les liens physiques des conseils actifs et de secours. ll transmet et reçoit 32 signaux E1/T1, et
code et décode les signaux E1/T1 (le taux de la transmission E1 est 2.048 Mbit/s et le taux de la
transmission T1 est 1.544 Mbit/s.)9.20.2 GEHUB/GEPUG(PEUa) Panneau
Les panneaux physiques du GEHUB et du GEPUG sont identiques. Après avoir été chargé avec le logiciel
différent, les conseils physiques exécutent différentes fonctions. Ces conseils ont le même aspect et
les mêmes LED et ports.

 Le GEPUG est l'unité de paquet de GM/M E1/T1 pour l'interface de gigaoctet. Il peut
être installé dans les fentes 14- 15 dans le GMPS/GEPS. Le GEPUG peut fonctionner en mode
et travail d'active/standby indépendamment.
Les fonctions du GEPUG Le GEPUG permettent la transmission E1/T1 sur l'interface de Pb.
GEHUB/GEPUG(PEUa) lambrissent les panneaux physiques du GEHUB et GEPUG sont identiques. Après
avoir été chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces
conseils ont le même aspect et les mêmes LED et ports.
Les LED sur GEHUB/GEPUG(PEUa) le panneau les panneaux physiques du GEHUB et du GEPUG sont
identiques. Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions. Ces conseils ont les mêmes types de LED sur les panneaux :COURSE, ALM, et LOI.

Les ports sur GEHUB/GEPUG(PEUa) le panneau les panneaux physiques du GEHUB et du GEPUG sont
identiques.Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent différentes
fonctions.Ces conseils ont les mêmes ports. Des six ports, quatre ports sont marqués E1/T1, un 2MO,
et un 2M1.
Les contacts DIP sur GEHUB/GEPUG(PEUa) les panneaux physiques du GEHUB et du GEPUG sont
identiques. Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions. Ils ont les mêmes types de contacts DIP :S2, S4, S6, S8, et S10.9.21.1 Fonctions
du GEPUG
Le GEPUG permet la transmission E1/T1 sur l'interface de Pb.
Le GEPUG exécute les fonctions suivantes :

l fournit quatre ports E1/T1 électriques, qui sont employés pour la transmission l de franc fournissent
le tributaire protègent la fonction du commutateur (TPS) pour permettre le changement entre les liens
physiques des conseils actifs et de secours. ll transmet et reçoit 32 signaux E1/T1, et code et décode
les signaux E1/T1 (le taux de la transmission E1 est 2.048 Mbit/s et le taux de la transmission T1 est
1.544 Mbit/s.)9.21.2 GEHUB/GEPUG(PEUa) Panneau

Les panneaux physiques du GEHUB et du GEPUG sont identiques. Après avoir été chargé avec le logiciel
différent, les conseils physiques exécutent différentes fonctions. Ces conseils ont le même aspect et
les mêmes LED et ports.

 Le GEXUB est l'unité extensible d'interface électronique de GM/M pour TDM E1/T1
fini et HDLC E1/T1 fini sur l'interface d'Abis.Il peut être installé dans les fentes 18-27 dans le
GMPS/GEPS.Quand BSC n'a pas besoin des services de processus de paquet, le GEXUB peut
également être installé dans les fentes 14-15.Le GEXUB peut fonctionner en mode et travail
d'active/standby indépendamment.

Les fonctions du GEXUB : Le GEXUB permet la transmission E1/T1 sur l'interface d'Abis.
GEHUB/GEPUG(PEUa) lambrissent les panneaux physiques du GEHUB et GEPUG sont identiques. Après
avoir été chargé avec le logiciel différent, les conseils physiques exécutent différentes fonctions. Ces
conseils ont le même aspect et les mêmes LED et ports.

Les LED sur GEHUB/GEPUG(PEUa) le panneau les panneaux physiques du GEHUB et du GEPUG sont
identiques. Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions. Ces conseils ont les mêmes types de LED sur les panneaux :COURSE, ALM, et LOI.

Les ports sur GEHUB/GEPUG(PEUa) le panneau les panneaux physiques du GEHUB et du GEPUG sont
identiques. Après avoir été chargé avec le logiciel différent, les conseils physiques exécutent
différentes fonctions .Ces conseils ont les mêmes ports. Des six ports, quatre ports sont marqués
E1/T1, un 2MO, et un 2M1.

GOMU

Ceci décrit l'unité d'opération et d'entretien de GM/M (GOMU).Il sert de serveur dans BSC. Le GOMUs
sont installés dans les fentes 20-23 dans le GMPS et travaillent dans le mode d'active/standby.
Comme le centre d'OM de BSC, le GOMU permet la communication entre le LMT et les autres conseils
dans BSC. Le GOMU comporte la vitesse élevée de calcul et les possibilités informatiques
exceptionnelles.

Le panneau de GOMU les composants sur le panneau de GOMU sont les LED et les ports.
Les LED sur le panneau de GOMU là sont cinq LED sur le panneau de GOMU :COURSE, ALM, ACTE, EN
DIFFÉRÉ, et HD.

4 ports sur le GOMU lambrissent les ports sur le panneau de GOMU se composent de quatre ports
d'USB (marqués Usb0-1 et Usb2-3), de trois ports de GE (marqués ETH0, ETH1, et ETH2), d'une porte
série Com-alm/com-bmc, et d'un port de VGA.
Fonctions du GOMU
Comme le centre d'OM de BSC, le GOMU permet la communication entre le LMT et les autres conseils
dans BSC. Le GOMU comporte la vitesse élevée de calcul et les possibilités informatiques
exceptionnelles.

Le GOMU exécute les fonctions suivantes :


l commande la communication entre l'ordinateur de LMT et les autres conseils dans BSC, facilite la
configuration de données, et rassemble et filtre l'exécution et les données l d'alarme traitent les
commandes publiées par le LMT computer/M2000, et puis expédient aux commandes aux autres
conseils dans BSC pour l de traitement filtres les résultats des autres conseils dans BSC, et renvoient
alors les résultats au panneau de l'ordinateur 9.10.2 GOMU de LMT.

 Configuration de BSC Subrack

Les subracks de BSC sont classifiés dans le GMPS, le GEPS, et le GTCS. Ceci décrit les configurations
recommandées de ces subracks dans différents scénarios d'application et modes de combinaison.
8.5.1 Configuration du GMPS (le type de configuration A) que Le GMPS est configuré dans GBCR.
Chaque BSC doit être configuré avec un GMPS. Le GMPS traite les services de base de BSC, exécute
l'opération et l'entretien, et fournit des signaux d'horloge pour le système. La configuration des
conseils dans le GMPS change avec les modes de configuration des subracks de BSC.8.5.2 Configuration
du GMPS (le type de configuration B) que Le GMPS est configuré dans GBCR. Chaque BSC doit être
configuré avec un GMPS. Le GMPS traite les services de base de BSC, exécute l'opération et l'entretien,
et fournit des signaux d'horloge pour le système. La configuration des conseils dans le GMPS change
avec les modes de configuration des subracks de BSC.8.5.3 La configuration du GEPS Le GEPS est
configurée dans le GBCR ou le GBSR.BSC peut être configurée avec zéro à trois GEPSs. Le GEPS traite
les services de base de BSC. La configuration des conseils dans le GEPS change avec les modes de
configuration des subracks de BSC.8.5.4 La configuration du GTCS en mode de configuration séparé
par BM/TC, le GTCS est configurée dans le GBCR ou le GBSR.BSC peut être configurée avec zéro à
quatre GTCSs. Le GTCS exécute le transcodage, l'adaptation de taux, et le secondaire-multiplexage.

 Configuration du GMPS (type de configuration A)


Le GMPS est configuré dans GBCR. Each BSC doit être configuré avec un GMPS. Le GMPS traite les
services de base de BSC, exécute l'opération et l'entretien, et fournit des signaux d'horloge pour le
système. La configuration des conseils dans le GMPS change avec les modes de configuration des
subracks de BSC.
 BM/TC Séparé (Construire-Dans la Servo-commande)
Dans BM/TC (servo-commande intégrée) le mode séparé de la configuration, le GMPS doit être
configuré avec le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUP, et le GEPUG/GFGUG. Les GDPUX, les
GXPUT, les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUT/GOIUT sont les
panneaux facultatifs.
 BM/TC Séparé (Servo-commande Externe)
Dans BM/TC (servo-commande externe) le mode séparé de la configuration, le GMPS doit être
configuré avec le GTNU, le GSCU, le GGCU, et le GXPUM.Les GXPUT, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, les GEIUP/GOIUP, et les GEIUT/GOIUT sont les
panneaux facultatifs.
 BM/TC Combiné (Construire-Dans la Servo-commande)
Dans BM/TC (servo-commande intégrée) le mode combiné de la configuration, le GMPS doit être
configuré avec le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUX, le GDPUP, et le GEPUG/GFGUG. Les
GXPUT, les GEIUA/GOIUA, et les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB sont les
panneaux facultatifs.
 BM/TC Combiné (Servo-commande Externe)
Dans BM/TC (servo-commande externe) le mode combiné de la configuration, le GMPS doit être
configuré avec le GTNU, le GSCU, le GGCU, le GXPUM, et le GDPUX. Les GXPUT, les GEIUA/GOIUA, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUP/GOIUP sont les panneaux
facultatifs.

 IP fini de A (Construire-Dans la servo-commande)


En mode fini de configuration d'IP de A (servo-commande intégrée), le GMPS doit être configuré avec
le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUX, le GDPUP, le GEPUG/GFGUG, et le GFGUA/GOGUA.
Les GXPUT et les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB sont les panneaux facultatifs.

 IP fini de A (servo-commande externe)


En mode fini de configuration d'IP de A (servo-commande externe), le GMPS doit être configuré avec
le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUX, et le GFGUA/GOGUA. Les GXPUT, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUP/GOIUP sont les panneaux
facultatifs.

 Le GMPS est configuré dans GBCR. Chaque BSC doit être configuré avec un GMPS. Le
GMPS traite les services de base de BSC, exécute l'opération et l'entretien, et fournit des
signaux d'horloge pour le système. La configuration des conseils dans le GMPS change avec les
modes de configuration des subracks de BSC.

 BM/TC Séparé (Construire-Dans la Servo-commande)


Dans BM/TC (servo-commande intégrée) le mode séparé de la configuration, le GMPS doit être
configuré avec le GOMU, le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUP, et le GEPUG/GFGUG. Les
GDPUX, les GXPUT, les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUT/GOIUT
sont les panneaux facultatifs.
 BM/TC Combiné (Construire-Dans la Servo-commande)
Dans BM/TC (servo-commande intégrée) le mode combiné de la configuration, le GMPS doit être
configuré avec le GOMU, le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUX, le GDPUP, et le
GEPUG/GFGUG. Les GXPUT, les GEIUA/GOIUA, et les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB sont les panneaux facultatifs.
 BM/TC Combiné (Servo-commande Externe)
Dans BM/TC (servo-commande externe) le mode combiné de la configuration, le GMPS doit être
configuré avec le GOMU, le GTNU, le GSCU, le GGCU, le GXPUM, et le GDPUX. Les GXPUT, les
GEIUA/GOIUA, les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUP/GOIUP sont
les panneaux facultatifs.
 IP fini de A (servo-commande externe)
En mode fini de configuration d'IP de A (servo-commande externe), le GMPS doit être configuré avec
le GTNU, le GSCU, le GGCU, le GXPUM, le GDPUX, et le GFGUA/GOGUA. Les GXPUT, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUP/GOIUP sont les panneaux
facultatifs.

Le GEPS est configuré dans le GBCR ou le GBSR.BSC peut être configurée avec zéro à trois GEPSs. Le
GEPS traite les services de base de BSC. La configuration des conseils dans le GEPS change avec les
modes de configuration des subracks de BSC.
BM/TC Séparé (Construire-Dans la Servo-commande)

Dans BM/TC (servo-commande intégrée) le mode séparé de la configuration, le GEPS doit être
configuré avec le GTNU, le GSCU, le GXPUM, le GDPUP, et le GEPUG/GFGUG. Les GDPUX, les GXPUT,
les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUT/GOIUT sont les panneaux
facultatifs.

 BM/TC Séparé (Servo-commande Externe)


Dans BM/TC (servo-commande externe) le mode séparé de la configuration, le GEPS doit être
configuré avec le GTNU, le GSCU, et le GXPUM. Les GXPUT, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, les GEIUP/GOIUP, et les GEIUT/GOIUT sont les
panneaux facultatifs.

 BM/TC Combiné (Construire-Dans la Servo-commande)


Dans BM/TC (servo-commande intégrée) le mode combiné de la configuration, le GEPS doit être
configuré avec le GTNU, le GSCU, le GXPUM, le GDPUX, le GDPUP, et le GEPUG/GFGUG. Les GXPUT, les
GEIUA/GOIUA, et les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB sont les panneaux
facultatifs.
 BM/TC Combiné (Servo-commande Externe)
Dans BM/TC (servo-commande externe) le mode combiné de la configuration, le GEPS doit être
configuré avec le GTNU, le GSCU, le GXPUM, et le GDPUX. Les GXPUT, les GEIUA/GOIUA, les
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB, et les GEIUP/GOIUP sont les panneaux
facultatifs.
 IP fini de A (Construire-Dans la servo-commande)
En mode fini de configuration d'IP de A (servo-commande intégrée), le GEPS doit être configuré avec
le GTNU, le GSCU, le GXPUM, le GDPUX, le GDPUP, le GEPUG/GFGUG, et le GFGUA/GOGUA. Les GXPUT
et les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB sont les panneaux facultatifs.

 IP fini de A (servo-commande externe) en mode fini de configuration d'IP de A (servo-


commande externe), le GEPS doit être configuré avec le GTNU, le GSCU, le GXPUM, le GDPUX,
et le GFGUA/GOGUA. Les GXPUT, les GEIUB/GOIUB/GEHUB/GFGUB/GOGUB/GEXUB/GOXUB,
et les GEIUP/GOIUP sont les panneaux facultatifs.

ATTENTION

Le GDPUX hérite de toutes les fonctions du GDPUC. Le GDPUX doit être configuré en n'importe laquelle
des conditions suivantes :dans BM/TC le mode combiné de configuration, dans BM/TC a séparé le
mode de configuration avec le GEHUB/GFGUB/GOGUB/GEXUB/GOXUB configuré, ou en mode fini de
configuration d'IP de A. Il quand le nombre de TRXs à soutenir est 256 plus grands que, une paire de
GXPUTs doit être configuré dans le GEPS. ll les interfaces de A, d'Abis, d'Ater, et de Pb soutiennent les
transmissions E1/T1, FE/GE, et Stm-1.L'interface de gigaoctet soutient des transmissions d'E1/T1 et de
FE/GE. Les figures précédentes prennent la transmission E1/T1 comme exemples, où le
GEIUA/GEIUB/GEIUT/GEIUP/GEHUB/GEPUG/GEXUB est configuré.
Pour des détails sur les conseils dans le GEPS, se référer à 9 conseils de BSC.8.5.4 La configuration du
GTCS en mode de configuration séparé par BM/TC, le GTCS est configurée dans le GBCR ou le GBSR.BSC
peut être configurée avec zéro à quatre GTCSs. Le GTCS exécute le transcodage, l'adaptation de taux,
et le secondaire-multiplexage.
Le GTCS doit être configuré avec le GSCU et le GTNU. Les GDPUX, les GEIUA/GOIUA, et les GEIUT/GOIUT
sont les panneaux facultatifs.

Quand la transmission E1/T1 est employée sur l'interface de A, un GTCS soutient un maximum de 4.800
chemins de la parole. Le schéma 8-23 montre le GTCS entièrement configuré.
Quand la transmission Stm-1 est employée sur l'interface de A, un GTCS soutient un maximum de 9.600
chemins de la parole. Le schéma 8-24 montre le GTCS entièrement configuré.