STANDARD UNIT SPECIFICATIONS
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

COMPRESSOR The control section includes:


- From size 17 to 31: - signal led unit in ON
hermetic rotary compressor. Fitted on rubber antivibration mounts and complete - signal led compressor state
with oil charge and suction filter - Selected function signal LED
- From size 41 to 51: - signal led ventilation state
hermetic orbiting scroll compressor complete with motor over-temperature and - temperature set point selection
over-current devices and protection against excessive gas discharge temperature. - energy optimization of compressor operation
Fitted on rubber antivibration mounts and complete with oil charge. - compressor overload protection and timer
- automatic regulation of operating mode (heating, FREE-COOLING, cooling)
STRUCTURE - self-diagnosis system with immediate display of the fault code
Self supporting panel structure in steel sheet protected by oven-dried polyster - display of the set values and the error codes
paint. The panels are easy to remove for complete accessibility to the internal - display of the parameter index
components and are internally coated with a thermo-acoustic insulation. - CLEAN function activation for a fixed time
The unit is furnished with condensate tray. - unit operation or ventilation only selection button
- COOL/HEAT button for the operating mode change, activation only fan mode
INTERNAL EXCHANGER and active mode signal
- Recovery section - On/Off button
direct expansion finned exchanger, made from copper pipes in staggered rows - UP and DOWN buttons to increase and decrease the values
and mechanically expanded to the fin collars. The fins are made from aluminium - alarm button to display the list of alarms
with a corrugated surface and adequately distanced to ensure the maximum heat - status button to display the status list
exchange efficiency. - ENTER button for programming
- SET button to set operating inputs
EXTERNAL EXCHANGER
- Recovery section TEST
finned exchanger, made from copper pipes arranged in staggered rows and Unit manufactured according to the ISO 9001 quality standards and subject to
mechanically expanded for better adherence to the collar of the fins. The fins are functional testing at the end of the production line
made from aluminium with a special corrugated surface, set a suitable distance
apart to ensure maximum heat exchange efficiency.

FAN
- supply fan
dual intake centrifugal electric fan with forward blades for maximum efficiency and
low noise. Statically- and dynamically-balanced according to the ISO 1940
standards, section 6.3. The scroll, the rotor and the frame are made from
galvanized steel plate (semdzimir). Directly coupled to the electric motor.
- exhaust fan
dual intake centrifugal electric fan with forward blades for maximum efficiency and
low noise. Statically- and dynamically-balanced according to the ISO 1940
standards, section 6.3. The scroll, the rotor and the frame are made from
galvanized steel plate (semdzimir). Directly coupled to the electric motor.

REFRIGERANT CIRCUIT
The refrigeration circuit is complete with:
- refrigerant charge
- High pressure safety pressure switch
- Low pressure safety switch
- filter dryer
- thermostatic expansion valve
- 4-way reverse cycle valve
- liquid receiver

FILTRATION
- outdoor air intake side
Pleated filter for greater filtering surface, made up of galvanized plate frame with
galvanized and electric-welded protective mesh, and regenerable filtering media
made from polyester fibre sized with synthetic resins. G4 efficiency according to
CEN-EN 779 standard (Eurovent class EU4/5 - average efficiency 90.1%
ASHRAE 52-76 Atm). Self-extinguishing (resistance to fire class 1 - DIN 53438).

TRAY
Thermoformed ABS condensate collection tray fitted with drain pipe.

ELECTRICAL PANEL
The Capacity Section includes:
- auxiliary circuit fuse
- compressor and fan fuses

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 2
(Data Version: 34 / 2016-03-14)
CONFIGURATION
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

UNIT CONFIGURATION Q.TY

Unit: CPAN-U 51 (R-410A) 1

R410A Refrigerant R-410A 1

400TN Supply voltage 400/3/50+N 1

IOM11X English Installation and Operation Manual (Accessory separately supplied) 1

FAS Standard air filter 1

outdoor air min. temperature (°C): 0.0 1

VS Standard Version 1

PM phase monitor 1

EHP14 4.5 kW preheating electric heaters 1

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 3
(Data Version: 34 / 2016-03-14)
TECHNICAL DATA
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

SELECTED OPERATION CONDITIONS

COOLING SELECTED HEATING SELECTED


Indoor air temperature (D.B.) °C 27.0 Indoor air temperature (D.B.) °C 20.0
Outdoor air temperature°C (D.B.) °C 35.0 Outdoor air temperature°C (D.B.) °C 7.00
Outdoor air temperature °C (W.B.) °C 24.0 Outdoor air temperature °C (W.B.) °C 6.10

PERFORMANCE DATA

COOLING SELECTED COP compressor Nr 6.08


Cooling capacity kW 15.9 COMPRESSOR SELECTED
Sensible capacity kW 12.5 Refrigerant charge (C1) kg 4.40
Compressor power input kW 3.84 STANDARD UNIT WEIGHTS SELECTED
EER compressor Nr 4.15 Shipping weight kg 201
HEATING SELECTED POWER SUPPLY SELECTED
Heating capacity kW 16.9 F.L.I. - Total kW 11.8
Compressor power input kW 2.79 F.L.A. - Total A 32.2
The sound pressure data are calculated at the required distance and referring to standard
conditions.

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 4
(Data Version: 34 / 2016-03-14)
TECHNICAL DATA
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

THE TECHNICAL DATA ARE APPROXIMATE AND MAY BE MODIFIED BY THE MANUFACTURER WITH NO REQUIREMENT
FOR ADVANCE NOTICE

TECHNICAL DATA REFER TO THE TECHNICAL BULLETIN

GENERAL >>> AIR HANDLING SECTION FANS (SUPPLY)


COOLING AIR HANDLING SECTION FANS (SUPPLY)
EER 4.14 Type of supply fan (4.4) CFG
Refrigeration circuits Nr 1.00 Number of supply fans Nr 1.00
HEATING Supply airflow l/s 920
COP 6.06 Installed unit power kW 0.600
WEIGHT AND DIMENSIONS Max. static pressure supply fan (4.5) Pa 340
Length mm 1503 F.L.A. - Single supply fan A 7.70
Depth mm 950 L.R.A. - Single supply fan A 34.0
Height mm 668 F.L.I. - Single supply fan kW 0.600
Shipping length mm 1550 Airflow l/s 890
Shipping depth mm 1030 FANS (EXHAUST)
Shipping height mm 812 Type of exhaust fan CFG
COMPRESSOR Number of exhaust fans Nr 1.00
No. of compressors Nr 1.00 Exhaust airflow l/s 860
Type of compressors (3.3) Scroll Installed unit power kW 0.600
Std Capacity control steps Nr 1.00 Max. exhaust static pressure Pa 360
F.L.A. - Compressor 1 A 10.3 FANS (RETURN)
L.R.A. - Compressor 1 A 64.0 L.R.A. - Single Return fan A 34.0
F.L.I. - Compressor 1 kW 6.10 ELECTRICAL DATA
M.I.C. MAXIMUM INRUSH CURRENT
M.I.C. - Value A 79.4
power supply 400/3/50 + neutral (4.4)CFG = centrifugal fan
power supply: 400/3/50 Hz +/-6% (4.5)Static pressure available on unit with electronic filters (excluding integration coil)
Voltage unbalance: max 2 %
Values not including accessories
(3.3)SCROLL = scroll compressor
ROT = rotary compressor

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 5
(Data Version: 34 / 2016-03-14)
TECHNICAL DATA
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

OPERATING RANGE (Cooling) OPERATING RANGE (Heating)


30
35
30
25 25
20
(1) 15

To (D .B .)
20
Ta (W.B.)

10 (1)
5
15
0
-5
10 -10 (2)
-15
-20
5
8 10 12 14 16 18 20 22 24
5 10 15 20 25 30 35 40
Ta (W .B .)
To (D.B.)

the limits are indicative and have been calculated considering: - values general and not
the limits are indicative and have been calculated considering: - values general and not specifications, - standard airflow, - non-critical positioning and correct use of the unit, -
specifications, - standard airflow, - non-critical positioning and correct use of the unit, - operation at full load
operation at full load ta = exhaust coil inlet air temperature (°c) w.b.
ta = outdoor air temperature/treatment coil inlet (°c) w.b. wb = wet bulb
wb = wet bulb to = outdoor air temperature/handling coil inlet (°c)
to = exhaust coil inlet air temperature (°c) db = dry bulb
db = dry bulb (1)
(1) the dashed area refers to the field of units operation
the dashed area refers to the field of units operation standard
standard (2)
operation field extension with preheating heaters

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 6
(Data Version: 34 / 2016-03-14)
DIMENSIONAL DRAWINGS
CPAN-U 51Heat pump primary air ceiling air conditioner(R410A-400TN-IOM11X-VS--)

1503
268 145 950

20
78.5
292

292

581
649

13

296.5

66
18

20 12 16 15 14 17
370 268 603 113
13 41.5 19
166.5 R
22.5

22.5
M

2
Q.E. 6
700 min.
3 700 min.
11
1
9

10
5 ES2
268

4
18
7
115

8
22.5
22.5

166.5 AE ES1
41.5
234 603

(1)Compressor (16)humidifier inlet water Ø 1/2" Gas


(2)Electrical panel (17)condensate drain pipe outlet
(3)supply fan (18)preheating electric heaters
(4)exhaust fan (19)exhaust air filter G4 (optional)
(5)treated air direct expansion coil (20)brackets for anchoring the unit to the ceiling
(6)exhaust air direct expansion coil R = air intake from outside
(7)Air filter M=outlet air
(8)Electric filters (optional) AE = Outdoor air intake
(9)Additional water coil (optional) ES1 = standard air exhaust
(10)3 ways-valve (optional) Translation not found for code 81477 on language en
(11)Steam humidifier (optional)
(12)removable panel for access to the technical compartment
(13)Power input
(14)water outlet additional coil Ø 3/4"
(15)water inlet additional coil Ø 3/4"

The presence of optional accessories may result in a substantial variation of the weights shown
in the table.

DIMENSIONS (mm)
Length Depth Height
1503 950 668

DATA FROM WWW.CLIVET.COM


Configuration 80236380 of 2/28/20 it.clivet.algoritmi 2.0.3 (Build: 20783a5 / 2019-12-20) pg 7
(Data Version: 34 / 2016-03-14)