Sunteți pe pagina 1din 37

OTIS

Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 1 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

LB-II
Installation Parameters

Authorization Date D1:


Running on PCB: GAA21230F
Software Version: GAA30163AAC

Document Revision :

Date Author Comment


5.NOV.1996 T.Lindemann
12.NOV.97 T.Lindemann
10.Mar.99 T.Lindemann Address 43 - 46 new

Copyright 1996, OTIS GmbH Berlin. No part of this document may be copied or reproduced
in any form or by any means without the prior written consent of OTIS GmbH.
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 2 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

Important Changes of Parameters between LB-II and MS-300

Address Descripiton

9 Hydraulic Type and Stopdelay

F Drive Selection

11 Additional EPO Funktion

40 ASN / J Phase Relay

41 Brake Curent Device

42 Motor Protection Device

43 DOH, ARBL,

44 ATT, REV

45 Position Reference System

46 ERO Function
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 3 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Explanation:
Display at the 7 - segment Display
on the board
C-NT

Shown at the Service Tool in SETUP


In the Service Tool is the display for Data ”A to F” as ”10 to 15”.

flashing Address Function

7-Segment- Time
display Dec. HEX Data (sec) Door times Default
Service Tool
0 0
0 0 1 1 Doortime Car 2
C-NT 2 2
3 3
1 1 4 4 Doortime Hall 4
H-NT 5 5
6 6
7 7 Time for door reversal relay,
2 2 8 8 0...3s in steps of 200ms 0
REV-T 9 9
A 10
B 11
3 3 C 12 Car -call has preference 0
CCP-T D 13 up to 15 sec.
E 14
F 15
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 4 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

flashing Address ARD-Automatic Car Return Device


7-Segment- DOP-Door Open Protection
display Dec. HEX Data CK-Reduce doortime with new car call Default
Service Tool
0 X (ARD, DOP, CK )
1 ARD after 10 seconds
2 DOP = 10 seconds
3 ARD after 10 seconds, DOP = 10 seconds
4 ARD after 3 minutes
5 ARD after 15 minutes
6 ARD after 3 minutes, DOP = 10 seconds
4 4 7 ARD after 15 minutes, DOP = 10 seconds
ARD... 8 CK
9 CK and ARD after 10 seconds
A CK and DOP = 10 seconds
B CK and ARD after 10 sec.,DOP = 10 sec.
C CK and ARD after 3 minutes
D CK and ARD after 15 minutes
E CK and ARD after 3 minutes, DOP = 10 sec
F CK and ARD after 15 minutes,DOP= 10 sec

flashing Address Function

7-Segment- En-
display trance
Service Tool Dec. HEX Data Position Indications Default
5 5 1-F 2 - 16 Top Position
TOP
6 6 Position of Lobby
LOBBY
0-F 1 - 16
7 7 Bottom Position
BOT

8 8 CTL or PKS - Floor (see also HEX 14)


CTL-P
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 5 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

flashing Address Function

7-Segment- Hydr. Types and Stopdelays


display Dec. HEX Data Motorized / Solenoid Default
Service Tool
Hydraulic with motorized valve
9 9 0-7 Delay time for car stop in steps of
HYDR 80msec. From 0 to 560 msec.

flashing Address Function

7-Segment- Hydr. Types and Stopdelays


display Dec. HEX Data Motorized / Solenoid Default
Service Tool
Hydraulic with solenoid valve
9 9 8-F Delay time for car stop in steps of
HYDR 80msec. From 0 to 560 msec.

flashing Address Function

7-Segment- En-
display Dec. HEX Data trance Position Indications Default
Service Tool

10 A Parking Position (see also HEX 4)


PPP

11 B 0-F 1 - 16 EPO Landing (see also HEX 11)


EPO-P

12 C EFS Landing (see also HEX 12)


EFO-P
Short Rise Position
13 D (slowly start from position)
SR-P
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 6 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7- Segment-
display Dec. HEX Data DCL or FCL Default
Service Tool

0 FCL

1 DCL ( one button at lobby in up direction )

14 E 2 DCL ( one button at lobby in down


F/DCL direction )

3 DCL ( two button at lobby /


FCL - function )

5 SAPB with Lift Comming Light

D SAPB with In Use Light

flashing Address Function


7- Segment-
display Dec. HEX Data All drive selection Default
Service Tool

0 One - speed AC stop on DZ

1 Two - speed AC and / or GAMMA L

2 GAMMA S ( XRLEV , XADO )

3 One - Speed AC stop on IPU, IPD

15 F 4 Two - speed AC without RLEV, G&T overlap-


ping during 2A time
DRIVE 5 Two - speed AC with RLEV by relay logic

6 GAMMA S with modul RLEV and XADO

E GAMMA S with modul RLEV and ADO

F Hydraulic
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 7 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7- Segment-
display Dec. HEX Data Simplex / Duplex, Frequency (Power) Default
Service Tool

0 Simplex, 50 Hz

1 Simplex, 60 Hz

16 10 8 Duplex, 50 Hz, Car A


GROUP

9 Duplex, 60 Hz, Car A

A Duplex, 50 Hz, Car B

B Duplex, 60 Hz, Car B

flashing Address Function


7- Segment-
display Dec. HEX Data Emergency Power Operation Default
Service Tool

0 XEPO

1 EPO - A ( Rescue to EPO - Landing )

17 11 2 EPO - B ( Rescue to next landing )


EPO

5 EPO - C ( Rescue to EPO -


Landing, Car takes full operation )

A EPO - D ( Rescue to next


landing, Car takes full operation )
Installation Parameters
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 8 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Software - Version 1.x

flashing Address Function


7- Segment-
display Dec. HEX Data Emergency Fireman Service Default
Service Tool

0 XEFO, XEFS

1 EFO DOB disabled

2 EFS1 without ISS DOB disabled


Automatic

3 EFS 1 without ISS DOB disabled


open door only with DOB Automatic

18 12 4 EFS2 and with ISS DOB disabled


EFO Manual

5 EFS 2 and with ISS DOB disabeld


open door only with DOB Manual

9 EFO DOB enabled

A EFS1 without ISS DOB enabled


Automatic

C EFS2 with ISS DOB enabled


Manual
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 9 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function Emergency Stop / DRR / SC / DPPL

DRR - Direction of recovery run


SC - Stock Controller
flashing Address ESS - Emergency Stop Switch or partition door
7-Segment- ESB - Reset only by new car call or partition door
display Dec. HEX Data DPPL - Disable Penalty for Parking at Lobby Default
Service Tool
0 ESS

1 ESB

2 ESS and DPPL

3 ESB and DPPL

4 DRR = Down and ESS and SC

5 ESB and SC

6 ESS and DPPL and SC

19 13 7 ESB and DPPL and SC

ES.. 8 ESS

9 ESB

A ESS and DPPL

B DRR = UP and ESB and DPPL

C ESS and SC

D ESB and SC

E ESS and DPPL and SC

F ESB and DPPL and SC


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 10 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

Funtion
flashing Address
7-Segment-
display Dec. HEX Data PKS / CTL / DCB / LWO Default
Service Tool
0 X ( PKS, CTL, DCB, LWO )

1 PKS

2 CTL

4 DCB

5 PKS and DCB

20 14 6 CTL and DCB

PKS.. 8 LWO

9 LWO and PKS

A LWO and CTL

C LWO and DCB

D LWO and PKS and DCB

E LWO and CTL and DCB


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 11 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function
CHCS on ISS - Input
flashing Address Multilight board / PMO / FLSH
7-Segment- PMO - Lightray device with monitor
display Dec. HEX Data FLSH - Flashing IL / TTL during running Default
Service Tool
0 X ( FLSH, PMO, MLB, CHCS (ISS))

1 MLB

2 FLSH

3 MLB and FLSH

4 PMO

5 PMO and MLB

6 PMO and FLSH

21 15 7 PMO and MLB and FLSH

MLB 8 CHCS ( ISS )

9 MLB

A FLSH

B FLSH and MLB

C CHCS ( ISS) and PMO

D PMO and MLB

E PMO and FLSH

F PMO and FLSH and


MLB
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 12 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7-Segment-
display Dec. HEX Data Type of door Default
Service Tool
0 ACG / DCP=10sec / X (ADO
1 FLH / DCP=10sec / X (ADO)
2 TLD/CLD / DCP=10sec / ADO
4 ACG ( Automatical car door and 10s pro-
tection time for door closing DCP
5 FLH (Swing doors) and 10s protection time
for DC - relais (cam magnet)
22 16 6 TLD / CLD and DCP without nudging,
limited door reversal and door detector
DOOR 8 ACG / NO DCP / X (ADO)
A TLD/CLD / NO DCP / EDPWITH LDR /
NUDGING / X (ADO)
C ACG ( Automatical car door ) without pro-
tection time for door closing
E TLD / CLD and EDP with LDR and nudging
without DCP

flashing Address Function


7-Segment-
display Dec. HEX Data Short Rise Default
Service Tool
0 X Short Rise

23 17 1 Type ”A” ( Two speed with delayed 2A )

EN-SR 2 Type ”B” ( Two speed without delay 2A )

4 GAMMA S, 2ND IP

8 GAMMA S, 1ST IP
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 13 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

flashing Address Function


7-Segment-
display Dec. HEX Data LNS or ANS Default
Service Tool
0 XLNS, XANS 0
1 ANS ( anti nuisance mechanically)
2 LNS ( load non stop mechanically)
3 LNS and ANS ( mechanically)
24 18 4 LNS ( electronically)
ANS.. 5 LNS ( electronically) ANS ( mechanically)
8 ANS ( electronically)
A LNS ( mechanically) ANS (electronically)
C LNS and ANS ( electronically)
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 14 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x

flashing Address Function


7-Segment- Parking enabled or disabled,
display Dec. HEX Data internal position from 0 to 3 Default
Service Tool
0 All position parking enabled ( 0, 1, 2, 3 )

1 Position 0 disabled (not with hydraulic)

2 Position 1 disabled

3 Position 1 and 0 disabled

4 Position 2 disabled

5 Position 2 and 0 disabled

6 Position 2 and 1 disabled

25 19 7 Position 2, 1 and 0 disabled

PRK00 8 Position 3 disabled

9 Position 3 and 0 disabled

A Position 3 and 1 disabled

B Position 3, 1 and 0 disabled

C Position 3 and 2 disabled

D Potion 3, 2 and 0 disabled

E Position 3, 2 and 1 disabled

F Position 3, 2, 1 and 0 disabled


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 15 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

flashing Address Function


7-Segment- Parking enabled or disabled,
display Dec. HEX Data internal position from 4 to 7 Default
Service Tool
0 All position parking enabled ( 4, 5, 6, 7 )

1 Position 4 disabled

2 Position 5 disabled

3 Position 5 and 4 disabled

4 Position 6 disabled

5 Position 6 and 4 disabled

6 Position 6 and 5 disabled

26 1A 7 Position 6, 5 and 4 disabled

PRK04 8 Position 7 disabled

9 Position 7 and 4 disabled

A Position 7 and 5 disabled

B Position 7, 5 and 4 disabled

C Position 7 and 6 disabled

D Potion 7, 6 and 4 disabled

E Position 7, 6 and 5 disabled

F Position 7, 6, 5 and 4 disabled


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 16 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7-Segment- Parking enabled or disabled,
display Dec. HEX Data internal position from 8 to 11 Default
0 All position parking enabled ( 8, 9, 10, 11 )

1 Position 8 disabled

2 Position 9 disabled

3 Position 9 and 8 disabled

4 Position 10 disabled

5 Position 10 and 8 disabled

6 Position 10 and 9 disabled

27 1B 7 Position 10, 9 and 8 disabled

PRK08 8 Position 11 disabled

9 Position 11 and 8 disabled

A Position 11 and 9 disabled

B Position 11, 9 and 8 disabled

C Position 11 and 10 disabled

D Position 11, 10 and 8 disabled

E Position 11, 10 and 9 disabled

F Position 11, 10, 9 and 8 disabled


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 17 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7-Segment- Parking enabled or disabled,
display Dec. HEX Data internal position from 12 to 15 Default
Service Tool
0 All position parking enabled ( 12, 13, 14, 15 )

1 Position 12 disabled

2 Position 13 disabled

3 Position 12 and 13 disabled

4 Position 14 disabled

5 Position 14 and 12 disabled

6 Position 14 and 13 disabled

28 1C 7 Position 14, 13 and 12 disabled

PRK12 8 Position 15 disabled

9 Position 15 and 12 disabled

A Position 15 and 13 disabled

B Position 15, 13 and 12 disabled

C Position 15 and 14 disabled

D Position 15, 14 and 12 disabled

E Position 15, 14 and 13 disabled

F Position 15, 14, 13 and 12 disabled


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 18 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function
flashing Address
7-Segment-
display Dec. HEX Data For Eng. - Service only Default
Service Tool
0 Normal Operation 0

1 DDO and CHCS,


switched off hall calls, doors closed
29 1D 2 CHCS, switched off hall calls

Test 4 CHCS, switched off hall calls continuous


call at lobby and parking position
5 CHCS, switched off hall calls, continuous call at
lobby and parking position, doors closed

Function
flashing Address
7-Segment- Timer 1A
display Dec. HEX Data Default
Service Tool
Delay for 1A Relay
30 1E 0 - F ( 0... 3 sec) decelaration in steps of 200ms

1A-T

Function
flashing Address
7-Segment- Timer 2A
display Dec. HEX Data Default
Service Tool
Delay for 2A relay
31 1F 0 - F ( 0... 3 sec) decelaration in steps of 200ms

2A-T
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 19 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7-Segment-
display Dec. HEX Data Landing Masks, Positionincrements Default
Service Tool
32 20 0 Landing enabled 0
POS00
33 21 1 LE Position +1
POS01
34 22 2 LE Position +2
POS02
35 23 3 LE Position +3
POS03
36 24 4 LE Position +4
POS04
37 25 5 LE Position +5
POS05
38 26 6 LE Position +6
POS06
39 27 7 LE Position +7
POS07
40 28 8 Landing disabled
POS08
41 29 9 LE Position -1
POS09
42 2A A LE Position -2
POS10
43 2B B LE Position -3
POS11
44 2C C LE Position -4
POS12
45 2D D LE Position -5
POS13
46 2E E LE Position -6
POS14
47 2F F LE Position -7
POS15
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 20 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

The addresses HEX 20 to 2F are for programming the position indicator when differ from the
internal counting, for example the values 1 to 7 when the display should show a higher num-
ber than the internal counting or 9 to F when the wanted display number is lower than the
internal one.
(see examples for Programming)

Attention! When using a Multi Light Board the calculation has to be done from the
wanted display number to the continuous display is wanted the addresse
HEX 20 to 2F have to be programmed with a 0 value.

see ” MLB, Multi Light Board” and ” Fixing of Indication for lowest Landing when using MLB”.
The value 8 can be choosen only to disable a landing, see description of ” Number of Calls
and Tell Tale Lights”.
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 21 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function
flashing Address
7-Segment-
display Dec. HEX Data Error / Warning Numbers
48 30 0-F Eldest error or warning number

49 31 0-F Eldest - 1 error or warning number

50 32 0-F Eldest - 2 error or warning number

51 33 0-F Latest error number

Possible errors: 0 : Reset


1 : Time out caused by board running flag
2 : Memory access error
3 : Doorzone lost within carmode WRR
4 : Position reference error
5 : Door open protection
6 : Door close protection
7 : Safty chain open during carmode run
8 : Safty chain open during carmode stop
9 : 24V power failure ( pulsing 24VDC on Pin P1.4 missing )
: Transmission error on serial link for duplex
: Parameter range error
: 24V Phase synchronisation error

Possible warning numbers: : Emergency stop accepted

: Special service performed (ISS, EPO, EFO, PKS, CTL )

: Inspection

In order to enter immediately into address 30 switch S3 twice within 2 seconds from position
2 to 1.
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 22 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function
flashing Address
7-Segment-
display Dec. HEX Data Time passed since latest error occured
52 34 0 - F Value X 45 h 30’40,0” ( 163840,0” )

53 35 0 - F Value X 2 h 50’40,0” ( 10240,0” )

54 36 0 - F Value X 10’40,0” ( 640,0” )

55 37 0 - F Value X 40,0” ( 40,0” )

56 38 0 - F Value X 2,5” ( 2,5” )

Function
flashing Address
7-Segment-
display Dec. HEX Data Version Identification
Service Tool
57 39 0 - F Number of version

58 3A 0 - F Number of revision

0 Extension time for DDP during RCMODE =


RUN (EDDP) (Basis 20 added with EDDP
in steps of 10 seconds)
59 3B 1 +10

EDDP 2 +20

3 +30
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 23 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function Changed door functions at parking mode,
internal positions from 0 to 3
flashing Address Type ACG = Parking with closed door
7-Segment- Types CLD/TLD = parking with opened door
display Dec. HEX Data
Service Tool
0 All positions same door functions ( 0, 1, 2, 3)

1 Position 0 changed

2 Position 1 changed

3 Position 1 and 0 changed

4 Position 2 changed

5 Position 2 and 0 changed

6 Position 2 and 1 changed

60 3C 7 Position 2, 1 and 0 changed

PKM00 8 Position 3 changed

9 Position 3 and 0 changed

A Position 3 and 1 changed

B Position 3,1 and 0 changed

C Position 3 and 2 changed

D Position 3, 2 and 0 changed

E Position 3, 2 and 1 changed

F Position 3, 2, 1 and 0 changed


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 24 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function Changed door functions at parking mode,
internal positions from 4 to 7
flashing Address Type ACG = Parking with closed door
7-Segment- Types CLD/TLD = parking with opened door
display Dec. HEX Data
Service Tool
0 All positions same door functions ( 4, 5, 6, 7)

1 Position 4 changed

2 Position 5 changed

3 Position 5 and 4 changed

4 Position 6 changed

5 Position 6 and 4 changed

6 Position 6 and 5 changed

61 3D 7 Position 6, 5 and 4 changed

PKM04 8 Position 7 changed

9 Position 7 and 4 changed

A Position 7 and 5 changed

B Position 7,5 and 4 changed

C Position 7 and 6 changed

D Position 7, 6 and 4 changed

E Position 7, 6 and 5 changed

F Position 7, 6, 5 and 4 changed


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 25 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function Changed door functions at parking mode,
internal positions from 8 to 11
flashing Address Type ACG = Parking with closed door
7-Segment- Types CLD/TLD = parking with opened door
display Dec. HEX Data
Service Tool
0 All positions same door functions ( 8, 9, 10, 11)

1 Position 8 changed

2 Position 9 changed

3 Position 9 and 8 changed

4 Position 10 changed

5 Position 10 and 8 changed

6 Position 10 and 9 changed

62 3E 7 Position 10, 9 and 8 changed

PKM08 8 Position 11 changed

9 Position 11 and 8 changed

A Position 11 and 9 changed

B Position 11, 9 and 8 changed

C Position 11 and 10 changed

D Position 11, 10 and 8 changed

E Position 11, 10 and 9 changed

F Position 11, 10, 9 and 8 changed


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 26 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
Function Changed door functions at parking mode,
internal positions from 12 to 15
flashing Address Type ACG = Parking with closed door
7-Segment- Types CLD/TLD = parking with opened door
display Dec. HEX Data
Service Tool
0 All positions same door functions ( 12, 13, 14, 15)

1 Position 12 changed

2 Position 13 changed

3 Position 13 and 12 changed

4 Position 14 changed

5 Position 14 and 12 changed

6 Position 14 and 13 changed

63 3F 7 Position 14, 13 and 12 changed

PKM12 8 Position 15 changed

9 Position 15 and 12 changed

A Position 15 and 13 changed

B Position 15, 13 and 12 changed

C Position 15 and 14 changed

D Position 15, 14 and 12 changed

E Position 15, 14 and 13 changed

F Position 15, 14, 13 and 12 changed


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 27 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Installation Parameters
Software - Version 1.x
flashing Address Function
7-Segment-
display Dec. HEX Data
Service
Tool
64 40 ASN / J Phase Relay
J
65 41 0 Brake Current Device
BCD 1
66 42 Motor Protection Device
MPD

flashing Address Function


7-Segment- DOH: Door Open Hold function is variable with
display button or switch via parameter ”DOH ” Bit 0
Service Tool DEC HEX Data ARBL: Automatic Return To Bottom Landing is dis-
able via parameter ”DOH ” Bit 1
DW delay is disable via parameter ”DOH ” Bit 2
CLD time is disable via paramter ”DOH ” Bit 3
0 DOHS, ARBL, DW delay, CLD time
1 DOHB, ARBL, DW delay, CLD time
2 DOHS, XARBL, DW delay, CLD time
3 DOHB, XARBL, DW delay, CLD time
4 DOHS, ARBL, X(DW delay), CLD time
5 DOHB, ARBL, X(DW delay), CLD time
6 DOHS, XARBL, X(DW delay), CLD time
67 43 7 DOHB, XABRL, X(DW delay), CLD time
DOH 8 DOHS, ARBL, DW delay, X(CLD time)
9 DOHB, ARBL. DW delay, X(CLD time)
10 DOHS, XARBL, DW delay, X(CLD time)
11 DOHB, XARBL, DW delay, X(CLD time)
12 DOHS, ARBL, X(DW delay), X(CLD time)
13 DOHB, ARBL, X(DW delay), X(CLD time)
14 DOHS, XARBL, X(DW delay), X(CLD time)
15 DOHB, XARBL, X(DW delay), X(CLD time)

Installation Parameters
Software - Version 1.x
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 28 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

flashing Address Function


7-Segment- ATT: Attendent Operation added (Initiated via ISS
input) enabled via parameter ”ATT ” Bit 0
display Dec. HEX Data REV: Output signal inverted via parameter
Service ”ATT ” Bit 1
Tool
0 XATT REV low activ

68 44 1 ATT, REV low activ


ATT
2 XATT, REV high activ

3 ATT, REV high activ

flashing Address Function


7-Segment-
display Dec. HEX Data Position Reference System
Service
Tool
0 Normal Position Reference

PRS 69 45 1 Low Cost Position Reference

flashing Address Function


7-Segment-
display Dec. HEX Data ERO
Service
Tool
70 46 0 ERO normal stop with 1LS / 2LS

ERO-T 1 ERO w/o 5LS and 6 LS


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 29 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming - Examples

1. Programming of the position indicator display ( 7-Segment-Display )

The following situation in the building is assumed :

- Number of stops 8

- Number of basements 1

- Desired position indication -1, 0, 1, 2, 3, 4, 5, 6

- Processor internal numbering 0, 1, 2, 3, 4, 5, 6, 7

- HexaDec. addresses 20, 21, 22, 23, 24, 25, 26, 27

Stop Position indication Internal numbering HexaDec. Data

6.Floor 6 7 27 9

5.Floor 5 6 26 9

4.Floor 4 5 25 9

3.Floor 3 4 24 9

2.Floor 2 3 23 9

1.Floor 1 2 22 9

Ground floor 0 1 21 9

Basement -1 0 20 9

Now the position indicator is to be programmed by setting the ”LANDING MASKS” (see be-
low) taking the internal numbering as a basis which always starts with zero (”0”).

”LANDING MASKS” ----> Informationen each landing

Exception:

Some duplex installations with different landings


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 30 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming - Examples ( Cont’d.)

The following notes are the conditions to program the position indicator :
-- Power on

-- TCI or ERO must be switched on

-- The programming switch S3 must be in position 1

-- The number of stops have to be programmed

-- The push button S2 must be pressed repeatly until the hexaDec. address 20
(equivalent Dec. 32)appears on the seven segment display of the logic board.
The segments and flash alternately, see also chapter : programming of parame
ters.

-- Pressing the push button S1 once results in a change of the display from addresses to
data, a non flashing now is shown.

-- Now the switch S2 must be pressed repeatedly again until the required value appears, in
this example a .

-- Pressing the switch S1 once will then terminate the programming sequence of the lowest
position indication.
The hexadecimal. form of the address 20 will appear ( and alternating ).

After this processor internal position is related to the required position indication.

-- Pressing the push button S2 once will display the hexaDec. address 21
( equivalent Dec. 32 ) on the seven segment display of the logic board.
( and flash alternately ) .
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 31 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming - Examples ( Cont’d.)

-- When the programming button S1 is pushed once a will appear.

-- The programming button S2 must now be pushed repeatly

-- Pushing the switch S1 will store this number under the address that appears again, now
on the flashing display.
In this example the hexaDec. address 21 is displayed.
A and flashing alternately on the seven segment display.

-- For every stop the required data must be programme likewise.


After the memory contains all the data necessary for the required position display
under the hexaDec. addresses 20 to 27.

--This programming sequence is finally terminated by switch S3 from position 1 to position 2,


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 32 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming - Examples ( Cont’d.)

Remark :

In this example the difference between the processor internal numbering and the requiered
position indication was always ” - 1 ” ( see table below ).

Installation Parameter Hexadezimal addresses 20 21 22 23 24 25 26 27


Memory content ( DATA ) 9 9 9 9 9 9 9 9
Processor internal 0 1 2 3 4 5 6 7
position
Required position -1 0 1 2 3 4 5 6
indication
Difference -1 -1 -1 -1 -1 -1 -1 -1
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 33 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming - Examples ( Cont’d.)

2. Programming of position indicator display with discontinuous landing numbering.

The following situation in the building is assumed:

- Number of stops 9

- Number of aements 2

- Desired position indication -2, -1, 1, 3, 5, 7, 9, 11, 13

- Processor internal numbering 0, 1, 2, 3, 4, 5, 6, 7, 8

- HexaDec. addresses 20, 21, 22, 23, 24, 25, 26, 27, 28

Installation Parameter Hexadezimal 20 21 22 23 24 25 26 27 28


addresses
Memory content A A 9 0 1 2 3 4 5
( DATA )
Processor internal 0 1 2 3 4 5 6 7 8
position
Required position -2 -2 1 3 5 7 9 11 13
indication
Difference -2 -2 -1 0 +1 +2 +3 +4 +5

The programming sequence of the data is identical to the first example.

The above table shows that the difference is not always the same for every landing, which
means that every hexaDec. addresss contains a different data.

The exeption is the selected the value 0 is displayed.

As the difference is 0, no data must be programmed and the next hexaDec. address (24) can
be selected right away.
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 34 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming Of Time Constants


Example for door time- on-call-range

If the default value of 2 seconds door time on car call is to be changed to 4 seconds for
instance, the procedure described below must be carried out:

Conditions are

- A functional test of the installation is positive

- The elevator is switched to TCI or ERO

- The progamming switch S3 is in position 1

The seven segment display of the logic board shows the flashing HEX-address .

- Pressing the push buton S1 once results in a change from the flashing display of the
address to the non flashing display of the memory content, a in this example.

- Pressing the push button S2 twice increments the data to .

- This programming sequence is finally terminated by switching S3 from position 1 to


position 2.

Remark:

The door open time can be programmed from 0 to 15 seconds in steps of 1 second.
See table below.
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 35 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming Of Time Constants ( Cont’d.)

Table

Required 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
time in
seconds
Data
to be
programmed
Address Doortime on car call
0
1 Doortime on hall call
2 Door Reversal Time REV-T not programming in seconds
3 Preference given on car call
OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 36 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Programming Of Time Constants ( Cont’d.)

Example for doortime on hall call

The default value for the doortime on hall call is 4 seconds. If this time is to be altered
according to different requirements in the building ( for instance old peoples home) the
procedure described below must be carried out.

Conditions are
- A functional test of the installation is positive

- The elevator is switched to TCI or ERO

- The programming switch S3 is in position 1

The seven segment displayof the logic board shows the flashing HEX-address
- Push button S2 once to change from the address to the hexaDec. address

- Push button S1 once to change from a flashing display of the HEX-address


to the non flashing memory content

- Push button S2 six times to increment the memory content to the value
which will then be displayed.

( correspondends to the Dec. number 10, see table above).

- This programming sequence is finally terminated by switching S3 from position 1 to 2.


OTIS
Part: 4 - AA3
FIELD COMPONENT MANUAL No.: GAA21230FVIIIa
European and Transcontinental
Vintage: 02/1
Operations
Page: 37 / 37
PRODUCT LB-II
Date: 12-NOV-96
ADMINISTRATION List of Installation Parameters

Progamming of parameters related on the building


By means of the table below it is possible to relate or alter different functional parame-
ters to certain landings.

Table

Memory
contents
Landings 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
HEX-Address Functions

5 Top landing position


6 Mainlanding position
7 Bottom landing position
8 CTL or PKS position
A Parking position
B EPO landing
C EFS landing
D Short landing position

Example:

For an elevator with eight landings the memory content must be programmed at the
HEX-address 5 with the value (see table)

Every possible value of data can be programmed AT EVERY POSSIBLE ADDRESS


WITH THE EXCEPTION OF which cannot be programmed for the top landing and
the which cannot be programmed for the bottom landing.

Note:

A table of the specific parameters for a contract is always part of the


contract wiring diagram!