Documente Academic
Documente Profesional
Documente Cultură
Issue 02
Date 2019-01-21
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Change History.............................................................................................................................. 1
1.1 eRAN13.1 02 (2019-01-21)............................................................................................................................................1
1.2 eRAN13.1 01 (2018-04-10)............................................................................................................................................2
1.3 eRAN13.1 Draft A (2018-02-05) (FDD)........................................................................................................................2
3 General Principles......................................................................................................................... 5
4 Signaling Connection Management.......................................................................................... 7
4.1 Principles........................................................................................................................................................................ 7
4.1.1 RRC Connection Setup................................................................................................................................................7
4.1.2 RRC Connection Reestablishment............................................................................................................................ 10
4.1.2.1 Conditions for Triggering RRC Connection Reestablishment............................................................................... 11
4.1.2.2 RRC Connection Reestablishment Procedure........................................................................................................ 12
4.1.2.3 Inter-PLMN RRC Connection Reestablishment Procedure................................................................................... 14
4.1.3 RRC Connection Management.................................................................................................................................. 15
4.1.3.1 Uplink Out-of-Synchronization Management........................................................................................................ 16
4.1.3.2 UE Inactivity Timer Management.......................................................................................................................... 16
4.1.3.3 RLF Detection........................................................................................................................................................ 20
4.1.4 Dedicated S1 Connection Setup................................................................................................................................ 20
4.1.5 Signaling Connection Release................................................................................................................................... 22
4.2 Network Analysis......................................................................................................................................................... 24
4.2.1 Benefits...................................................................................................................................................................... 24
4.2.2 Impacts.......................................................................................................................................................................25
4.3 Requirements................................................................................................................................................................ 25
4.3.1 Licenses..................................................................................................................................................................... 25
4.3.2 Software.....................................................................................................................................................................25
4.3.3 Hardware................................................................................................................................................................... 26
4.3.4 Others.........................................................................................................................................................................26
4.4 Operation and Maintenance..........................................................................................................................................26
4.4.1 Data Configuration.................................................................................................................................................... 26
4.4.1.1 Data Preparation..................................................................................................................................................... 26
6 Parameters..................................................................................................................................... 45
7 Counters...................................................................................................................................... 107
8 Glossary....................................................................................................................................... 603
9 Reference Documents............................................................................................................... 604
1 Change History
This chapter describes changes not included in the "Parameters", "Counters", "Glossary", and
"Reference Documents" chapters. These changes include:
l Technical changes
Changes in functions and their corresponding parameters
l Editorial changes
Improvements or revisions to the documentation
Technical Changes
Change Description Parameter Change Base Station Model
Editorial Changes
Revised descriptions in this document.
Technical Changes
Change Description Parameter Change Base Station Model
Editorial Changes
Added deactivation command examples. For details, see the respective "Using MML
Commands" sections.
Revised descriptions in this document.
Technical Changes
Change Description Parameter Change Base Station Model
Editorial Changes
Incorporated both FDD and TDD descriptions into this document, and reorganized this
document using a new template.
3 General Principles
l Setup of dedicated connections between user equipment (UE), eNodeBs, and mobility
management entities (MMEs)
l Releases of these connections after services are complete
Figure 3-1 shows the random access, signaling connection management, and radio bearer
management procedures involved in connection management.
NOTE
For details about security mode control shown in Figure 3-1, see Radio Security.
1. Random access: The UE performs a random access procedure when it needs to set up a
connection with the network for service requests, location updates, paging, or other
reasons. For details about this procedure, see Random Access Control.
2. Signaling connection setup: Signaling connections are established between the UE and
the MME. Signaling connections are set up before the security mode control. There are
two types of signaling connections:
– RRC connections: signaling connections between the eNodeB and UE over the air
interface
– Dedicated S1 connection: signaling connection between the eNodeB and MME
3. E-RAB setup: When the UE requests a service, the MME instructs the eNodeB to set up
an E-UTRAN radio access bearer (E-RAB), including a radio bearer.
4.1 Principles
Signaling connections include an RRC connection and a dedicated S1 connection, as shown in
Figure 4-1. Generally, a signaling connection is set up for a service bearer. It can also be set
up only for a signaling procedure, such as a UE location update.
1. The UE sends the eNodeB an RRC Connection Request message containing the reason
for the RRC connection setup.
NOTE
l The reason for RRC connection setup is related to the NAS process and NAS session types.
For details, see 3GPP TS 24.301 V8.1.0.
l The RRC Connection Request message contains the UE_ID field. If the upper layer provides
the S-TMSI, the UE signals the S-TMSI to the eNodeB. If no S-TMSI is available, the UE
signals a random value ranging from 0 to 240-1 to the eNodeB. The international mobile
subscriber identity (IMSI) of the UE is unknown to the eNodeB.
2. The eNodeB sets up the context for the UE.
If the eNodeB receives multiple RRC Connection Request messages from the UE within
a specified time window, the eNodeB handles only the most recent one. The time
window is equal to the sum of the values of UeTimerConst.T300 and
RrcConnStateTimer.FilterReptRrcConnReqTimer parameters.
Within a length of time equal to that specified by the UeTimerConst.T300 and the
RrcConnStateTimer.FilterReptRrcConnReqTimer parameters, combined, the eNodeB
calculates the number of RRC Connection Request messages sent by a UE, except in
high-priority access and emergency call scenarios. If the number of RRC Connection
Request messages sent by a UE is greater than the value of the
GlobalProcSwitch.RrcConnPunishThd or
GlobalProcSwitch.LteRrcConnPunishmentThld parameter, the eNodeB responds to
the UE with an RRC Connection Reject message containing the wait time IE. The value
of this wait time is determined by the RrcConnStateTimer.T302 parameter. Upon
receiving the message, the UE sends another RRC Connection Request message only
after the wait time expires.
NOTE
For the process of determining whether the number of UEs exceeds the UE quantity
license, see 4.1.4 Dedicated S1 Connection Setup. For UE admission and resource
pre-emption, see Admission and Congestion Control.
– If admission fails and there is no resource pre-emption enabled, the eNodeB sends
an RRC Connection Reject message to the UE.
n If an RRC connection setup request is rejected, the UE needs to wait for a
period before sending another RRC connection setup request. The length of
this period is determined by a timer specified by the
RrcConnStateTimer.T302 parameter. This timer starts when the UE receives
an RRC Connection Reject message and stops when the UE enters
RRC_CONNECTED mode or cell reselection is performed.
n The eNodeB instructs the UE to lower the cell reselection priority by sending
the UE an RRC Connection Reject message containing the deprioritisationReq
IE (the CELLALGOSWITCH.DeprioritisationDeliverInd parameter is not
set to UNDELIVER). Upon receiving the message, the UE attempts to access
the network from other cells, relieving the cell overload. If an RRC
Connection Reject message contains the deprioritisationReq IE and the UE can
process this IE, the timer specified by the UETIMERCONST.T325 parameter
starts. Check the value of the deprioritisationType field in the
deprioritisationReq IE, that is, the value of the
CELLALGOSWITCH.DeprioritisationDeliverInd parameter, as described in
the following table.
NOTE
The deprioritisationReq IE has been introduced since 3GPP Release 11. For details,
see 3GPP TS 36.331.
4. The eNodeB sends an RRC Connection Setup message containing SRB1 resource
configurations to the UE.
5. The UE configures radio resources based on the SRB1 resource information indicated by
the RRC Connection Setup message, and then sends an RRC Connection Setup
Complete message to the eNodeB. After the eNodeB receives the RRC Connection
Setup Complete message, the RRC connection is set up.
The timer for the eNodeB to wait for an RRC Connection Setup Complete message is
specified by the ENodeBConnStateTimer.WaitRrcConnSetupCmpTimer parameter.
The eNodeB starts another timer to wait for the UE to send other messages over the Uu
interface. The timer is specified by the following parameters:
– ENodeBConnStateTimer.UuMessageWaitingTimer if the UE is not running QCI
1 services
– ENodeBConnStateTimer.UuMessageWaitingTimerQci1 if the UE is running QCI
1 services
A UE starts the timer specified by the UeTimerConst.T310 parameter when both of the following
conditions are met:
1. The number of out-of-sync indications consecutively received by the UE from lower layers has
reached the upper limit specified by the UeTimerConst.N310 parameter.
2. None of the timers specified by the following parameters are running:
l UeTimerConst.T300
l UeTimerConst.T301
l RrcConnStateTimer.T304ForEutran
l RrcConnStateTimer.T304ForGeran
l UeTimerConst.T311
When the timer specified by the UeTimerConst.T310 parameter is running and the number of in-
sync indications consecutively received from lower layers has reached the upper limit specified by
the UeTimerConst.N311 parameter, the UE stops the timer specified by the UeTimerConst.T310
parameter.
l A handover fails.
The cause value contained in the message depends on the reason for the RRC connection
reestablishment.
l An RRC connection reconfiguration failure
The message contains the cause value "reconfigurationFailure".
l A handover failure
The message contains the cause value "handoverFailure".
l A radio link failure
The message contains the cause value "otherFailure".
In the cause value, the C-RNTI and physCellId IEs indicate the C-RNTI and physical cell ID of
the serving cell, respectively.
2. The eNodeB checks whether there is a UE context.
If there is, the eNodeB proceeds to 3.
If there is not, the target eNodeB sends an RLF Indication message to the source eNodeB
based on the cell information contained in the RRC Connection Reestablishment Request
message. If the source eNodeB has the UE context, the source eNodeB initiates the
handover process. In the handover, the source eNodeB transfers the UE context to the
target eNodeB. The GlobalProcSwitch.RrcReestOptSwitch parameter specifies whether
the target eNodeB can implement RRC connection reestablishment without UE contexts.
3. The eNodeB authenticates the UE. If the security authentication data in the UE is
consistent with that in the eNodeB, the UE passes authentication. After the
authentication, the eNodeB releases original resources and then performs admission and
resource allocation again.
– If the GlobalProcSwitch.EnhancedRRCReestProtectThd parameter is set to 0 and
the number of RRC Connection Reestablishment Request messages containing the
cause value "reconfigurationFailure" sent by a UE within 1 minute exceeds the
threshold specified by the GlobalProcSwitch.RrcReestProtectThd parameter, the
eNodeB rejects subsequent RRC connection reestablishment requests containing the
same cause value sent by the UE and the UE enters the RRC idle mode. The
GlobalProcSwitch.RrcReestProtectThd parameter will be disused in later versions.
l The MME is configured with the PLMNs required before and after RRC connection
reestablishment.
l Inter-PLMN roaming is enabled on the MME.
l An S1 link is set up between the eNodeB and MME for each PLMN.
Inter-PLMN RRC connection reestablishment can be performed between physical eNodeBs
or within a physical eNodeB.
Procedure. After an RRC connection is reestablished between PLMNs and different physical
eNodeBs, the TeNodeB sends a Path Switch Request message to the MME to complete the
switching of the downlink GTP tunnel endpoint. A Path Switch Request message needs to be
sent over the S1 link corresponding to the target PLMN.
l To maintain uplink timing for a UE, the eNodeB delivers timing advance commands to
the UE. Each time the eNodeB receives an ACK message from the UE, the eNodeB
starts or restarts the uplink time alignment timer specified by the
TimeAlignmentTimer.TimeAlignmentTimer parameter. If the timer expires, the
eNodeB considers the UE to have entered the out-of-synchronization state.
l For each UE, the eNodeB also maintains an uplink synchronization timer specified by
the RrcConnStateTimer.UlSynTimer parameter to control whether to deliver a Timing
Advance Command message to the UE. The eNodeB starts or restarts the timer for a UE
when sending data to or receiving data from the UE.
– The eNodeB continuously sends Timing Advance Command messages to the UE
until the timer expires.
– Once it has expired, the eNodeB stops sending the messages, and the UE stops
providing ACK responses. In this situation, the uplink alignment timer expires, and
the eNodeB regards that the UE is in the out-of-synchronization state.
If the UE inactivity timer is shorter than the timer specified by the
RrcConnStateTimer.UlSynTimer parameter, the RRC connection is released for the UE
and the UE enters idle mode.
l If the InactReSyncCompatSwitch option of the
GlobalProcSwitch.ProtocolMsgOptSwitch parameter is selected when the UE inactivity
timer expires and the resynchronization procedure is ongoing, the eNodeB restarts the
UE inactivity timer and preferentially handles the resynchronization procedure. If the
InactReSyncCompatSwitch option is deselected, the eNodeB releases UEs when the
UE inactivity timer expires, and the UEs enter idle mode.
If the UE loses synchronization in the uplink:
l The eNodeB instructs the UE to initiate a random access procedure when the eNodeB
needs to transmit data to the UE.
l The UE initiates a random access procedure to restore uplink synchronization if it needs
to transmit data to the eNodeB.
As of eRAN12.1, the uplink synchronization timer can be specified by the
QciPara.UlSynTimerForQci parameter. The QciPara.UlSynTimerForQci parameter is
recommended because the RrcConnStateTimer.UlSynTimer parameter will be disused in a
later version.
To prevent inactive UEs from using system resources for a long time, the eNodeB releases the
RRC connection for the UE and sends a UE Context Release Request message to the EPC
when the UE inactivity timer expires.
The UE Context Release Request message contains the cause value "Radio Connection With
UE Lost" if both of the following conditions are met:
l An RLF has been detected or the number of RLC connections for all the DRBs have
reached the threshold specified by the
RLCPDCPPARAGROUP.UeMaxRetxThreshold parameter before the UE inactivity
timer expires.
l Uplink synchronization does not recover for the UE.
In other situations, the UE Context Release Request message contains the cause value "User
Inactivity."
Table 4-1 Parameters specifying the UE inactivity timer when PTT services are ongoing
Value of the Parameter Specifying the UE Inactivity Timer
CELLALGOSWITCH.DynD
rxSwitch Parameter
DynDrxSwitch(DynDrxSwitch QciPara.UeInactivityTimerDynDrxQci
) check box selected
DynDrxSwitch(DynDrxSwitch QciPara.UeInactiveTimerForQci
) check box cleared
Figure 4-6 Parameters specifying the UE inactivity timer when voice services are ongoing
NOTE
The preceding license has an impact on the configuration of the UE inactivity timer only when the UE is
performing voice services and the DynDrxSwitch(DynDrxSwitch) check box is cleared under the
CELLALGOSWITCH.DynDrxSwitch parameter.
Figure 4-7 Parameters specifying the UE inactivity timer used in other situations
NOTE
The timer expires l The eNodeB instructs the UE to initiate random access when the
eNodeB needs to transmit data to the UE.
l The UE initiates random access when the UE needs to transmit
data to the eNodeB.
– If the synchronization is successful, the radio link of the UE
recovers.
– If the synchronization fails, an RLF has occurred. In this case,
the eNodeB releases the RRC connection for the UE.
1. The UE sends the eNodeB an RRC Connection Setup Complete message containing a
NAS message. Upon receiving the message, the eNodeB allocates a dedicated S1AP ID
to the UE, encapsulates the NAS message and S1AP ID in an Initial UE Message, and
sends the message to the MME.
NOTE
For details about how the eNodeB selects an MME when an eNodeB connects to multiple MMEs,
see S1-Flex.
2. The MME obtains the cause for this connection setup from the NAS message contained
in the Initial UE Message, handles the UE service request, and assigns the dedicated
S1AP ID to the UE.
The timer for the eNodeB to wait for S1AP-related messages from the MME depends on
whether the UE is running QCI 1 services.
The eNodeB selects a security algorithm supported by both the eNodeB and UE and then sends the
algorithm to the UE using a Security Mode Command message. For details about the security
mode handling mechanism, see Radio Security.
5. The eNodeB performs admission based on the UE quantity license, implements resource
pre-emption for the UE, makes service admission decisions, and allocates resources to
the UE.
– If the UE is successfully admitted, the procedure continues.
– If the admission fails, the eNodeB sends an INITIAL CONTEXT SETUP
FAILURE message to the MME.
NOTE
For admission based on the UE quantity license and UE resource pre-emption, see
Admission and Congestion Control.
6. The eNodeB sends a Security Mode Command message, instructing the UE to start
integrity protection and encryption. At this moment, downlink encryption is started.
7. The eNodeB sends an RRC Connection Reconfiguration message to the UE for the setup
of SRB2 and DRB. Encryption and integrity protection have been performed for this
message.
8. After receiving the Security Mode Command message from the eNodeB, the UE uses the
encryption algorithm specified by the eNodeB to generate security keys for both service
bearers and signaling connections. Then, the UE sends a Security Mode Complete
message, which is not encrypted. After the eNodeB receives this message, uplink
encryption is started.
9. The UE sets up a dedicated S1 connection based on the RRC Connection
Reconfiguration message and then sends an RRC Connection Reconfiguration Complete
message to the eNodeB.
10. The eNodeB sends an Initial Context Setup Response message to the MME.
The eNodeB simultaneously sends security parameters and bearer parameters to the UE. The
security mode setup starts first. The RRC Connection Reconfiguration message can be sent
before the security mode setup ends. This mechanism reduces the delay from the initial UE
access to the bearer setup.
NOTE
The MME can also release the dedicated S1 connection to simultaneously release all the E-RABs.
For eNodeBs:
l When a UE becomes inactive and the signaling link has been released, the UE may have
lost connections with the network. When the GlobalProcSwitch.UeRelChkLostSwitch
parameter is set to ON(On), the eNodeB checks the connection between the UE and
network.
– If the connection is abnormal, the UE Context Release Request message contains
the cause value "Radio Connection With UE Lost."
– If the connection is proper, the UE Context Release Request message contains the
cause value "User inactivity."
l If an UE in the uplink out-of-synchronization state needs to transmit downlink data, the
eNodeB instructs the UE to initiate random access to restore uplink synchronization with
the eNodeB. The UE can try the restoration for many times. If the restoration fails for the
number of times specified by the GlobalProcSwitch.UeRelReSynTimes parameter, the
eNodeB releases the UE. The release is executed after a delay so that the UE has a
chance to reestablish the RRC connection with the serving cell. The delay is specified by
the CellQciPara.TrafficRelDelay parameter and is service (QCI) specific.
l Some defective UEs on networks do not respond to eNodeBs with RLC status reports.
This causes the number of downlink RLC retransmissions on SRB1 to reach the
maximum. In this case, the eNodeBs do not send RRC Connection Release messages to
the UEs, and the UEs encounter RRC connection reestablishments, which all fail as a
result. An optimization mechanism can now be used to prevent such RRC connection
reestablishments. If the CellDlschAlgo.Srb1SchEnhancementSwitch parameter is set to
ON, the eNodeB will send RRC Connection Release messages even if the number of
downlink RLC retransmissions on SRB1 reaches the maximum value.
4.2.1 Benefits
Connection management is a basic network feature. It is a prerequisite for UEs to access the
network and perform services on established bearers.
RRC connection reestablishment optimization for defective UEs reduces the proportion of
RRC connection reestablishments and increases the reestablishment success rate.
4.2.2 Impacts
Network Impacts
l The impact on network performance increases with the penetration rate of the UEs that
support the deprioritisationReq IE during major events.
– The RRC connection reject-triggered cell reselection function improves the RRC
connection setup success rate and decreases the network access delay when the
number of RRC connections in a multi-band or multi-RAT cell is far below the
upper limit.
– This function increases the number of network access attempts when the number of
RRC connections in a multi-band or multi-RAT cell is close to the upper limit. In
this situation, the RRC connection setup success rate and network access delay may
decrease.
Function Impacts
None
4.3 Requirements
4.3.1 Licenses
None
4.3.2 Software
Prerequisite Functions
RAT Function Name Function Switch Reference
4.3.3 Hardware
Boards
No requirements
RF Modules
No requirements
4.3.4 Others
The LBBPc does not support PDCP with a serial number (SN) longer than 18 bits. If PDCP
with an SN (specified by the RLCPDCPPARAGROUP.AmPdcpSnSize parameter) longer
than 18 bits is deployed for the eNodeB, the eNodeB replaces the SN with a 15-bit one when
deploying the PDCP instances of E-RABs set up for a UE on an LBBPc board.
l Table 4-5 describes the parameter used for activating RRC connection reestablishment
optimization for defective UEs.
Table 4-5 Parameter used for activating RRC connection reestablishment optimization
for defective UEs
Parameter Parameter ID Setting Notes
Name
l Table 4-6 describes the parameter used for activating inter-PLMN RRC connection
reestablishment.
Table 4-6 Parameter used for activating inter-PLMN RRC connection reestablishment
Parameter Parameter ID Setting Notes
Name
Step 3 View the Uu interface tracing result. If the result contains the RRC_CONN_REQ and
RRC_CONN_SETUP_CMP messages, as shown in Figure 4-10, signaling connection
management has been activated.
Step 4 View the S1 interface tracing result. If the result contains the S1AP_INITIAL_UE_MSG and
S1AP_INITIAL_CONTEXT_SETUP_RSP messages as shown in Figure 4-11, radio bearer
management has been activated.
----End
1526728217 L.RRC.ConnReq.Att.Emc
1526728218 L.RRC.ConnReq.Att.HighPri
1526728219 L.RRC.ConnReq.Att.Mt
1526728221 L.RRC.ConnReq.Att.MoData
1526728357 L.RRC.ConnReq.Att.DelayTol
1526745657 L.RRC.ConnReq.Att.MoVoiceCall
1526728222 L.RRC.ConnReq.Succ.Emc
1526728223 L.RRC.ConnReq.Succ.HighPri
1526728224 L.RRC.ConnReq.Succ.Mt
1526728226 L.RRC.ConnReq.Succ.MoData
1526728358 L.RRC.ConnReq.Succ.DelayTol
1526745658 L.RRC.ConnReq.Succ.MoVoiceCall
1526728220 L.RRC.ConnReq.Att.MoSig
1526728225 L.RRC.ConnReq.Succ.MoSig
1526726668 L.E-RAB.AttEst.QCI.1
1526726669 L.E-RAB.SuccEst.QCI.1
1526739741 L.E-RAB.FailEst.X2AP.VoIP
1526727545 L.E-RAB.AttEst
1526727544 L.E-RAB.SuccEst
1526739740 L.E-RAB.FailEst.X2AP
1526726686 L.E-RAB.AbnormRel.QCI.1
1526726687 L.E-RAB.NormRel.QCI.1
1526741743 L.E-RAB.NormRel.IRatHOOut.QCI.1
1526727546 L.E-RAB.AbnormRel
1526727547 L.E-RAB.NormRel
1526741752 L.E-RAB.NormRel.IRatHOOut
1526727514 L.E-RAB.SuccModify.QCI.1
1526727513 L.E-RAB.AttModify.QCI.1
1526728249 L.E-RAB.SuccModify
1526728248 L.E-RAB.AttModify
Fault Description
The E-RAB setup success rate deteriorates significantly.
NOTE
If the RRC setup success rate deteriorates significantly, contact Huawei for technical support.
Fault Handling
Step 1 On the U2000 client, start S1 interface tracing and obtain the tracing result.
Step 2 View the tracing result to check whether there are a large number of
S1AP_INITIAL_CONTEXT_SETUP_FAIL messages. If yes, proceed to the next step. If no,
contact Huawei for technical support.
Step 4 Run the MOD GTPU command with the STATICCHK parameter set to ENABLE(Enable)
to enable the GTP-U tunnel detection function.
Step 5 Run the ADD ENODEBPATH command to add the application type of the IP path
corresponding to the S1 interface. In this step, set the Application Type parameter to S1(S1).
Step 6 Run the DSP IPPATH command to check whether the value of the IP Path Check Result
parameter is Fault. If yes, adjust the IP path according to the network plan. If no, contact
Huawei for technical support.
----End
Alarm
Alarm ID Alarm Name
5.1 Principles
Figure 5-1 shows the location of a radio bearer in an E2E service in the overall service
architecture.
Figure 5-1 Radio bearer in the E2E service in the overall service architecture
Radio bearers are classified into signaling radio bearers (SRBs) and data radio bearers
(DRBs).
l SRBs carry signaling in the control plane. There are three types of SRBs:
– SRB0: carries RRC signaling through a common control channel (CCCH) in
transparent mode (TM) at the radio link control (RLC) layer before the RRC
connection is successfully set up.
– SRB1: carries RRC signaling messages after the RRC connection is successfully set
up, and carries NAS messages before SRB2 is set up. SRB1 is transmitted through a
dedicated control channel (DCCH) in acknowledged mode (AM) at the RLC layer.
– SRB2: carries NAS signaling through a DCCH in AM mode at the RLC layer.
SRB2 has a lower priority than SRB1, and SRB2 can be set up only after the
security mode is activated.
NOTE
l For details about SRB0, SRB1, and SRB2, see section 6.2.2 in 3GPP TS 36.331 V9.16.0.
l For details about NAS, see 3GPP TS 24.301.
l DRBs carry data in the user plane. A maximum of eight DRBs can be set up between the
UE and the eNodeB. The actual number depends on different QoS classes.
l In this document, radio bearer management refers to SRB2 and DRB management by the
eNodeB after the security mode is set up. It involves the setup, modification, and release
of SRB2 and DRBs.
During radio bearer management, the UE communicates with the eNodeB using the RRC
Connection Reconfiguration message. The RRC connection is reconfigured when a radio
bearer needs to be set up, modified, or released and when handover measurement information
needs to be configured or modified. The application scenarios are differentiated using
different IEs in the RRC Connection Reconfiguration message.
In this process, the sum of the GBR, non-GBR, and newly applied GBR of the UE must be
less than or equal to the maximum rate of the UE in the current cell (in both the uplink and
downlink. Otherwise, new E-RABs fail to be set up. The maximum rate of a UE in the current
cell is determined by the cell bandwidth and UE capability. For details, see in 3900 Series
Base Station Product Documentation and 5900 Series Base Station Product Documentation.
NOTE
l The eNodeB determines whether to admit GBR services (new services or handover services) based
on the PRB usage and the QoS satisfaction rate of GBR services. For details, see Admission and
Congestion Control.
l For details about transport resource admission control, see Transmission Resource Management.
with those for the original QCI. If they are consistent, the eNodeB can modify the
QCI and E-RAB. If they are not consistent, the QCI and E-RAB modifications fail.
5.2.1 Benefits
Connection management is a basic network feature. It is a prerequisite for UEs to access the
network and perform services on established bearers.
The RRC connection reject-triggered cell reselection function is recommended in heavy-
traffic scenarios.
RRC connection reestablishment optimization for defective UEs reduces the proportion of
RRC connection reestablishments and increases the reestablishment success rate.
5.2.2 Impacts
Network Impacts
None
Function Impacts
None
5.3 Requirements
5.3.1 Licenses
None
5.3.2 Software
Prerequisite Functions
RAT Function Name Function Switch Reference
5.3.3 Hardware
Boards
None
RF Modules
None
5.3.4 Others
The LBBPc does not support PDCP with a serial number (SN) longer than 18 bits. If PDCP
with an SN (specified by the RLCPDCPPARAGROUP.AmPdcpSnSize parameter) longer
than 18 bits is deployed for the eNodeB, the eNodeB replaces the SN with a 15-bit one when
deploying the PDCP instances of E-RABs set up for a UE on an LBBPc board.
Step 3 View the Uu interface tracing result. Observe SRB and DRB setup in the
RRC_CONN_RECFG message. radioResourceConfigDedicated->srb-ToAddModList->SRB-
ToAddMod and radioResourceConfigDedicated->drb-ToAddModList->DRB-ToAddMod
show SRB and DRB setup, as shown in Figure 5-6.
Step 4 View the S1 interface tracing result. If the result contains the S1AP_INITIAL_UE_MSG and
S1AP_INITIAL_CONTEXT_SETUP_RSP messages shown in Figure 5-7, radio bearer
management has been activated.
----End
6 Parameters
RsvdSwPara3_bit16(ReservedSwitchParame-
ter3_bit16),
RsvdSwPara3_bit17(ReservedSwitchParame-
ter3_bit17),
RsvdSwPara3_bit18(ReservedSwitchParame-
ter3_bit18),
RsvdSwPara3_bit19(ReservedSwitchParame-
ter3_bit19),
RsvdSwPara3_bit20(ReservedSwitchParame-
ter3_bit20),
RsvdSwPara3_bit21(ReservedSwitchParame-
ter3_bit21),
RsvdSwPara3_bit22(ReservedSwitchParame-
ter3_bit22),
RsvdSwPara3_bit23(ReservedSwitchParame-
ter3_bit23),
RsvdSwPara3_bit24(ReservedSwitchParame-
ter3_bit24),
RsvdSwPara3_bit25(ReservedSwitchParame-
ter3_bit25),
RsvdSwPara3_bit26(ReservedSwitchParame-
ter3_bit26),
RsvdSwPara3_bit27(ReservedSwitchParame-
ter3_bit27),
RsvdSwPara3_bit28(ReservedSwitchParame-
ter3_bit28),
RsvdSwPara3_bit29(ReservedSwitchParame-
ter3_bit29),
RsvdSwPara3_bit30(ReservedSwitchParame-
ter3_bit30),
RsvdSwPara3_bit31(ReservedSwitchParame-
ter3_bit31),
RsvdSwPara3_bit32(ReservedSwitchParame-
ter3_bit32)
Unit: None
Actual Value Range: RsvdSwPara3_bit1,
RsvdSwPara3_bit2, RsvdSwPara3_bit3,
RsvdSwPara3_bit4, RsvdSwPara3_bit5,
RsvdSwPara3_bit6, RsvdSwPara3_bit7,
RsvdSwPara3_bit8, RsvdSwPara3_bit9,
RsvdSwPara3_bit10, RsvdSwPara3_bit11,
RsvdSwPara3_bit12, RsvdSwPara3_bit13,
RsvdSwPara3_bit14, RsvdSwPara3_bit15,
RsvdSwPara3_bit16, RsvdSwPara3_bit17,
RsvdSwPara3_bit18, RsvdSwPara3_bit19,
RsvdSwPara3_bit20, RsvdSwPara3_bit21,
RsvdSwPara3_bit22, RsvdSwPara3_bit23,
RsvdSwPara3_bit24, RsvdSwPara3_bit25,
RsvdSwPara3_bit26, RsvdSwPara3_bit27,
RsvdSwPara3_bit28, RsvdSwPara3_bit29,
RsvdSwPara3_bit30, RsvdSwPara3_bit31,
RsvdSwPara3_bit32
Default Value: RsvdSwPara3_bit1:Off,
RsvdSwPara3_bit2:Off, RsvdSwPara3_bit3:Off,
RsvdSwPara3_bit4:Off, RsvdSwPara3_bit5:Off,
RsvdSwPara3_bit6:Off, RsvdSwPara3_bit7:Off,
RsvdSwPara3_bit8:Off, RsvdSwPara3_bit9:Off,
RsvdSwPara3_bit10:Off, RsvdSwPara3_bit11:Off,
RsvdSwPara3_bit12:Off, RsvdSwPara3_bit13:Off,
RsvdSwPara3_bit14:Off, RsvdSwPara3_bit15:Off,
RsvdSwPara3_bit16:Off, RsvdSwPara3_bit17:Off,
RsvdSwPara3_bit18:Off, RsvdSwPara3_bit19:Off,
RsvdSwPara3_bit20:Off, RsvdSwPara3_bit21:Off,
RsvdSwPara3_bit22:Off, RsvdSwPara3_bit23:Off,
RsvdSwPara3_bit24:Off, RsvdSwPara3_bit25:Off,
RsvdSwPara3_bit26:Off, RsvdSwPara3_bit27:Off,
RsvdSwPara3_bit28:Off, RsvdSwPara3_bit29:Off,
RsvdSwPara3_bit30:Off, RsvdSwPara3_bit31:Off,
RsvdSwPara3_bit32:Off
GlobalP LteRrcC MOD LBFD-0 RRC Meaning: Indicates the threshold for an RRC
rocSwitc onnPuni GLOBA 02007/ Connect connection penalty on LTE UEs. Certain UEs may
h shmentT LPROC TDLBF ion repeatedly fail to access networks because of
hld SWITC D-00200 Manage compatibility issues. If this parameter is set to 0, the
H 7 ment RRC connection penalty function is disabled. If this
LST parameter is set to a non-zero value, the function is
GLOBA enabled. If the number of RRC connection setup
LPROC requests that the eNodeB receives from a UE within
SWITC the time specified by the sum of T300 and
H FilterReptRrcConnReqTimer exceeds the threshold,
the eNodeB imposes a penalty on the UE, rejecting
RRC connection setup requests from the UE. This
parameter is valid only for LTE UEs. When the
RrcConnPunishThd parameter in the
GlobalProcSwitch MO is set to a non-zero value, the
LteRrcConnPunishmentThld parameter is invalid. In
this case, the RRC connection penalty threshold
specified by the RrcConnPunishThd parameter takes
effect on LTE UEs. When the RrcConnPunishThd
parameter is set to 0, the RRC connection penalty
threshold specified by the LteRrcConnPunish-
mentThld parameter takes effect on LTE UEs. This
parameter applies only to LTE FDD and LTE TDD.
GUI Value Range: 0~3600
Unit: None
Actual Value Range: 0~3600
Default Value: 0
GlobalP EmtcRrc MOD MLOFD eMTC Meaning: Indicates the threshold for an RRC
rocSwitc ConnPu GLOBA -121280 Introduc connection penalty on eMTC UEs. Certain UEs may
h nishmen LPROC / tion repeatedly fail to access networks because of
tThld SWITC TDLEO compatibility issues. If this parameter is set to 0, the
H FD-121 RRC connection penalty function is disabled. If this
LST 611 parameter is set to a non-zero value, the function is
GLOBA enabled. If the number of RRC connection setup
LPROC requests that the eNodeB receives from a UE within
SWITC the time specified by the sum of T300CE and
H FilterReptRrcConnReqTimer exceeds the threshold,
the eNodeB imposes a penalty on the UE, rejecting
RRC connection setup requests from the UE. This
parameter is valid only for eMTC UEs. When the
RrcConnPunishThd parameter in the
GlobalProcSwitch MO is set to a non-zero value, the
EmtcRrcConnPunishmentThld parameter is invalid. In
this case, the RRC connection penalty threshold
specified by the RrcConnPunishThd parameter takes
effect on eMTC UEs. When the RrcConnPunishThd
parameter is set to 0, the RRC connection penalty
threshold specified by the EmtcRrcConnPunish-
mentThld parameter takes effect on eMTC UEs. This
parameter applies only to LTE FDD and LTE TDD.
GUI Value Range: 0~3600
Unit: None
Actual Value Range: 0~3600
Default Value: 0
GlobalP NbRrcC MOD MLBFD RRC Meaning: Indicates the threshold for an RRC
rocSwitc onnPuni GLOBA -120002 Connect connection penalty on NB-IoT UEs. Certain UEs may
h shmentT LPROC 28 ion repeatedly fail to access networks because of
hld SWITC Manage compatibility issues. If this parameter is set to 0, the
H ment RRC connection penalty function is disabled. If this
LST parameter is set to a non-zero value, the function is
GLOBA enabled. If the number of RRC connection setup
LPROC requests that the eNodeB receives from a UE within
SWITC the time specified by the sum of T300ForNb and
H FilterReptRrcConnReqTimer exceeds the threshold,
the eNodeB imposes a penalty on the UE, rejecting
RRC connection setup requests from the UE. When
the RrcConnPunishThd parameter in the
GlobalProcSwitch MO is set to a non-zero value, the
NbRrcConnPunishmentThld parameter is invalid. In
this case, the RRC connection penalty threshold
specified by the RrcConnPunishThd parameter takes
effect on NB-IoT UEs. When the RrcConnPunishThd
parameter is set to 0, the RRC connection penalty
threshold specified by the NbRrcConnPunish-
mentThld parameter takes effect on NB-IoT UEs. This
parameter applies only to NB-IoT.
GUI Value Range: 0~3600
Unit: None
Actual Value Range: 0~3600
Default Value: 0
CellDlsc Srb1Sch MOD LBFD-0 RRC Meaning: Indicates whether to continue delivering
hAlgo Enhance CELLD 02007 Connect RRC Connection Release signaling carried by SRB1
mentSwi LSCHA ion when the number of SRB1 retransmissions has
tch LGO Manage reached the maximum at the RLC layer. If this
LST ment parameter is set to OFF, the eNodeB stops SRB1
CELLD scheduling and no longer delivers the RRC
LSCHA Connection Release signaling when the number of
LGO SRB1 retransmissions has reached the maximum at
the RLC layer. If this parameter is set to ON, the
eNodeB continues SRB1 scheduling and delivers
RRC Connection Release signaling when the number
of SRB1 retransmissions has reached the maximum at
the RLC layer. This option applies only to LTE FDD
and LTE TDD.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF(Off)
RrcCon FilterRe MOD LBFD-0 RRC Meaning: Indicates the length of the timer for the
nStateTi ptRrcCo RRCCO 02007/ Connect eNodeB to filter repeated RRC Connection Request
mer nnReqTi NNSTA TDLBF ion messages. The actually used timer length is the sum of
mer TETIM D-00200 Manage T300 length and the value of this parameter.
ER 7 ment GUI Value Range: 0~15
LST Unit: s
RRCCO
NNSTA Actual Value Range: 0~15
TETIM Default Value: 15
ER
GlobalP RrcCon MOD LBFD-0 RRC Meaning: Indicates the threshold for an RRC
rocSwitc nPunish GLOBA 02007/ Connect connection penalty. Certain UEs may repeatedly fail
h Thd LPROC TDLBF ion to access networks because of incompatibility issues.
SWITC D-00200 Manage If the number of RRC connection setup requests that
H 7 ment the eNodeB receives from a UE within the time
LST specified by the sum of the FilterReptRrcConnReq-
GLOBA Timer parameter value and the T300 timer exceeds the
LPROC threshold (a non-zero value), the eNodeB imposes a
SWITC penalty on the UE, rejecting RRC connection setup
H requests from the UE. If this parameter is set to 0, the
penalty does not take effect.
GUI Value Range: 0~3600
Unit: None
Actual Value Range: 0~3600
Default Value: 0
CellAlg Depriori MOD LBFD-0 RRC Meaning: Indicates whether the RRCConnectionRe-
oSwitch tisation CELLA 02007/ Connect ject message includes the IE deprioritisationReq and
DeliverI LGOSW TDLBF ion the setting of the IE deprioritisationType. If this
nd ITCH D-00200 Manage parameter is set to UNDELIVER(UNDELIVER), the
LST 7 ment RRCConnectionReject message does not include the
CELLA IE deprioritisationReq. If this parameter is set to
LGOSW FREQUENCY(FREQUENCY), the
ITCH RRCConnectionReject message includes the IE
deprioritisationReq and the value of the IE
deprioritisationType is FREQUENCY. In this case,
after the UE receives an RRCConnectionReject
message, the lowest cell reselection priority is
configured for the serving frequency and the
frequencies contained in the RRCConnectionReject
messages that have been received and include the IE
deprioritisationReq. If this parameter is set to
EUTRA(EUTRA), the RRCConnectionReject
message includes the IE deprioritisationReq and the
value of the IE deprioritisationType is EUTRA. In this
case, after the UE receives an RRCConnectionReject
message, the lowest cell reselection priority is
configured for all E-UTRAN frequencies. For details
about the IEs, see 3GPP TS 36.331. This parameter
applies only to LTE FDD and LTE TDD.
GUI Value Range: UNDELIVER(UNDELIVER),
FREQUENCY(FREQUENCY), EUTRA(EUTRA)
Unit: None
Actual Value Range: UNDELIVER, FREQUENCY,
EUTRA
Default Value: UNDELIVER(UNDELIVER)
UeTime T325 MOD LBFD-0 RRC Meaning: Indicates the length of timer 325. For
rConst UETIM 02007/ Connect details, see 3GPP TS 36.331. This timer starts when a
ERCON TDLBF ion UE receives an RRCConnectionReject message
ST D-00200 Manage containing the deprioritisationReq IE. When the timer
LST 7 ment expires, the cell reselection priorities that have been
UETIM reduced using RRCConnectionReject for E-UTRAN
ERCON frequencies are restored. This parameter applies only
ST to LTE FDD and LTE TDD.
GUI Value Range: MIN5_T325(MIN5_T325),
MIN10_T325(MIN10_T325),
MIN15_T325(MIN15_T325),
MIN30_T325(MIN30_T325)
Unit: None
Actual Value Range: MIN5_T325, MIN10_T325,
MIN15_T325, MIN30_T325
Default Value: MIN5_T325(MIN5_T325)
ENodeB WaitRrc MOD LBFD-0 RRC Meaning: Indicates the timer for the eNodeB to wait
ConnSta ConnSet ENODE 02007/ Connect for an RRC Connection Setup Complete message.
teTimer upCmpT BCONN TDLBF ion GUI Value Range: 3~15
imer STATET D-00200 Manage
IMER 7 ment Unit: s
ENodeB UuMess MOD LBFD-0 RRC Meaning: Indicates the timer governing the period the
ConnSta ageWaiti ENODE 02007/ Connect eNodeB waits for a response message from a UE
teTimer ngTimer BCONN TDLBF ion when the UE is running non-QCI1 services. If the
STATET D-00200 Manage timer expires, the eNodeB initiates a UE context
IMER 7 ment release over the S1 interface.
LST GUI Value Range: 1~200
ENODE Unit: s
BCONN
STATET Actual Value Range: 1~200
IMER Default Value: 35
ENodeB UuMess MOD LBFD-0 RRC Meaning: Indicates the timer governing the period the
ConnSta ageWaiti ENODE 02007/ Connect eNodeB waits for a response message from a UE
teTimer ngTimer BCONN TDLBF ion when the UE is running services with the QCI of 1. If
Qci1 STATET D-00200 Manage the timer expires, the eNodeB initiates a UE context
IMER 7 ment release over the S1 interface. This parameter applies
LST LBFD-1 Support only to LTE FDD and LTE TDD.
ENODE 31107/ of GUI Value Range: 1~200
BCONN TDLBF VoLTE Unit: s
STATET D-08110
IMER 1 Actual Value Range: 1~200
Default Value: 35
RrcCon T304For MOD None None Meaning: Indicates the length of the timer T304 for
nStateTi Eutran RRCCO intra-RAT handover. If the UE does not complete the
mer NNSTA handover before this timer expires, the UE reverts
TETIM back to the associated configuration and initiates an
ER RRC connection reestablishment procedure. This
LST parameter applies only to LTE FDD and LTE TDD.
RRCCO GUI Value Range: ms50(50), ms100(100),
NNSTA ms150(150), ms200(200), ms500(500),
TETIM ms1000(1000), ms2000(2000)
ER Unit: ms
Actual Value Range: ms50, ms100, ms150, ms200,
ms500, ms1000, ms2000
Default Value: ms500(500)
RrcCon T304For MOD None None Meaning: Indicates the length of the timer T304 for
nStateTi Geran RRCCO inter-RAT handover to GERAN. If the UE does not
mer NNSTA complete the handover before this timer expires, the
TETIM UE reverts back to the associated configuration and
ER initiates an RRC connection re-establishment
LST procedure. This parameter applies only to LTE FDD
RRCCO and LTE TDD.
NNSTA GUI Value Range: ms100(100), ms200(200),
TETIM ms500(500), ms1000(1000), ms2000(2000),
ER ms4000(4000), ms8000(8000)
Unit: ms
Actual Value Range: ms100, ms200, ms500, ms1000,
ms2000, ms4000, ms8000
Default Value: ms8000(8000)
RlcPdcp UeMax ADD LBFD-0 Radio Meaning: Indicates the maximum number of RLC
ParaGro RetxThr RLCPD 02008/ Bearer ARQ retransmissions for UEs, which limits the
up eshold CPPAR TDLBF Manage maximum number of AM PDU retransmissions. When
AGROU D-00200 ment the number of RCL ARQ retransmissions reaches the
P 8 parameter value, an RRC connection reestablishment
MOD procedure is initiated. This option applies only to LTE
RLCPD FDD and LTE TDD.
CPPAR GUI Value Range: Maxretx_Threshold_t1(1),
AGROU Maxretx_Threshold_t2(2), Maxretx_Threshold_t3(3),
P Maxretx_Threshold_t4(4), Maxretx_Threshold_t6(6),
LST Maxretx_Threshold_t8(8),
RLCPD Maxretx_Threshold_t16(16),
CPPAR Maxretx_Threshold_t32(32)
AGROU Unit: None
P Actual Value Range: Maxretx_Threshold_t1,
Maxretx_Threshold_t2, Maxretx_Threshold_t3,
Maxretx_Threshold_t4, Maxretx_Threshold_t6,
Maxretx_Threshold_t8, Maxretx_Threshold_t16,
Maxretx_Threshold_t32
Default Value: Maxretx_Threshold_t32(32)
UeTime N310 MOD LBFD-0 Broadca Meaning: Indicates the maximum number of
rConst UETIM 02009/ st of successive "out of sync" indications received from L1.
ERCON TDLBF system For details, see 3GPP TS 36.331.
ST D-00200 informat GUI Value Range: n1(1), n2(2), n3(3), n4(4), n6(6),
LST 9 ion n8(8), n10(10), n20(20)
UETIM Unit: None
ERCON
ST Actual Value Range: n1, n2, n3, n4, n6, n8, n10, n20
Default Value: n10(10)
UeTime N311 MOD LBFD-0 Broadca Meaning: Indicates the maximum number of
rConst UETIM 02009/ st of successive "in sync" indications received from L1. For
ERCON TDLBF system details, see 3GPP TS 36.331.
ST D-00200 informat GUI Value Range: n1(1), n2(2), n3(3), n4(4), n5(5),
LST 9 ion n6(6), n8(8), n10(10)
UETIM Unit: None
ERCON
ST Actual Value Range: n1, n2, n3, n4, n5, n6, n8, n10
Default Value: n1(1)
RlfTime RlfTime ADD LBFD-0 RRC Meaning: Indicates the RLF timer and constants group
rConstG rConstG RLFTI 02007/ Connect ID. This parameter applies only to LTE FDD and LTE
roup roupId MERCO TDLBF ion TDD.
NSTGR D-00200 Manage GUI Value Range: 0~9
OUP 7 ment
Unit: None
LST
RLFTI Actual Value Range: 0~9
MERCO Default Value: None
NSTGR
OUP
MOD
RLFTI
MERCO
NSTGR
OUP
RMV
RLFTI
MERCO
NSTGR
OUP
RlfTime T301 ADD LBFD-0 RRC Meaning: Indicates the length of the timer T301. For
rConstG RLFTI 02007/ Connect details, see 3GPP TS 36.331. This parameter applies
roup MERCO TDLBF ion only to LTE FDD and LTE TDD.
NSTGR D-00200 Manage GUI Value Range: MS100_T301(100ms),
OUP 7 ment MS200_T301(200ms), MS300_T301(300ms),
MOD MS400_T301(400ms), MS600_T301(600ms),
RLFTI MS1000_T301(1000ms), MS1500_T301(1500ms),
MERCO MS2000_T301(2000ms)
NSTGR Unit: None
OUP
Actual Value Range: MS100_T301, MS200_T301,
LST MS300_T301, MS400_T301, MS600_T301,
RLFTI MS1000_T301, MS1500_T301, MS2000_T301
MERCO
NSTGR Default Value: MS200_T301(200ms)
OUP
RlfTime T310 ADD LBFD-0 RRC Meaning: Indicates the length of the timer T310. For
rConstG RLFTI 02007/ Connect details, see 3GPP TS 36.331. This parameter applies
roup MERCO TDLBF ion only to LTE FDD and LTE TDD.
NSTGR D-00200 Manage GUI Value Range: MS0_T310(0ms),
OUP 7 ment MS50_T310(50ms), MS100_T310(100ms),
MOD MS200_T310(200ms), MS500_T310(500ms),
RLFTI MS1000_T310(1000ms), MS2000_T310(2000ms)
MERCO Unit: None
NSTGR
OUP Actual Value Range: MS0_T310, MS50_T310,
MS100_T310, MS200_T310, MS500_T310,
LST MS1000_T310, MS2000_T310
RLFTI
MERCO Default Value: MS1000_T310(1000ms)
NSTGR
OUP
RlfTime T311 ADD LBFD-0 RRC Meaning: Indicates the length of the timer T311. For
rConstG RLFTI 02007/ Connect details, see 3GPP TS 36.331. This parameter applies
roup MERCO TDLBF ion only to LTE FDD and LTE TDD.
NSTGR D-00200 Manage GUI Value Range: MS1000_T311(1000ms),
OUP 7 ment MS3000_T311(3000ms), MS5000_T311(5000ms),
MOD MS10000_T311(10000ms),
RLFTI MS15000_T311(15000ms),
MERCO MS20000_T311(20000ms),
NSTGR MS30000_T311(30000ms)
OUP
Unit: None
LST
Actual Value Range: MS1000_T311, MS3000_T311,
RLFTI
MS5000_T311, MS10000_T311, MS15000_T311,
MERCO
MS20000_T311, MS30000_T311
NSTGR
OUP Default Value: MS10000_T311(10000ms)
RlfTime N310 ADD LBFD-0 RRC Meaning: Indicates the maximum number of
rConstG RLFTI 02007/ Connect successive "out of sync" indications received from L1.
roup MERCO TDLBF ion For details, see 3GPP TS 36.331. This parameter
NSTGR D-00200 Manage applies only to LTE FDD and LTE TDD.
OUP 7 ment GUI Value Range: n1(1), n2(2), n3(3), n4(4), n6(6),
MOD n8(8), n10(10), n20(20)
RLFTI Unit: None
MERCO
NSTGR Actual Value Range: n1, n2, n3, n4, n6, n8, n10, n20
OUP Default Value: n10(10)
LST
RLFTI
MERCO
NSTGR
OUP
RlfTime N311 ADD LBFD-0 RRC Meaning: Indicates the maximum number of
rConstG RLFTI 02007/ Connect successive "in sync" indications received from L1. For
roup MERCO TDLBF ion details, see 3GPP TS 36.331. This parameter applies
NSTGR D-00200 Manage only to LTE FDD and LTE TDD.
OUP 7 ment GUI Value Range: n1(1), n2(2), n3(3), n4(4), n5(5),
MOD n6(6), n8(8), n10(10)
RLFTI Unit: None
MERCO
NSTGR Actual Value Range: n1, n2, n3, n4, n5, n6, n8, n10
OUP Default Value: n1(1)
LST
RLFTI
MERCO
NSTGR
OUP
S1_HANDOVER_REEST_SWITCH(S1_HANDOVE
R_REEST_SWITCH),
NO_CONTEXT_REEST_SWITCH(NO_CONTEXT
_REEST_SWITCH),
SEC_CMD_REEST_SWITCH(SEC_CMD_REEST_
SWITCH),
WITH_X2_NO_NCELL_REEST_SWITCH(WITH_
X2_NO_NCELL_REEST_SWITCH)
Unit: None
Actual Value Range:
PCI_CONFUSION_REEST_SWITCH,
S1_HANDOVER_REEST_SWITCH,
NO_CONTEXT_REEST_SWITCH,
SEC_CMD_REEST_SWITCH,
WITH_X2_NO_NCELL_REEST_SWITCH
Default Value:
PCI_CONFUSION_REEST_SWITCH:On,
S1_HANDOVER_REEST_SWITCH:On,
NO_CONTEXT_REEST_SWITCH:Off,
SEC_CMD_REEST_SWITCH:On,
WITH_X2_NO_NCELL_REEST_SWITCH:Off
GlobalP Enhance MOD LBFD-0 RRC Meaning: Indicates the protection threshold of the
rocSwitc dRRCR GLOBA 02007 Connect number of RRC connection reestablishments initiated
h eestProt LPROC ion by the same UE in an eNodeB. UE manufacturers may
ectThd SWITC Manage have different understanding of protocols, and
H ment therefore UE compliance with protocols varies and
LST may be different from eNodeB compliance with the
GLOBA same protocols. Some UEs may initiate the same RRC
LPROC connection reestablishments repeatedly. When this
SWITC parameter is set to a non-zero value, the RRC
H connection reestablishment protection function is
enabled. This function releases a UE when the number
of RRC connection reestablishment procedures
initiated by the UE in an eNodeB exceeds the
threshold. In this case, the RrcReestProtectThd
parameter does not take effect. When this parameter is
set to 0, the RRC connection reestablishment
protection function is disabled. This parameter applies
only to LTE FDD and LTE TDD.
GUI Value Range: 0~65535
Unit: None
Actual Value Range: 0~65535
Default Value: 0
GlobalP RrcRees MOD LBFD-0 RRC Meaning: Indicates the RRC connection
rocSwitc tProtect GLOBA 02007 Connect reestablishment protection threshold. UE
h Thd LPROC TDLBF ion manufacturers may have different understanding of
SWITC D-00200 Manage protocols, and therefore UE compliance with
H 8 ment protocols varies and may be different from eNodeB
LST Radio compliance with the same protocols. After a UE
GLOBA Bearer initiates an RRC connection reestablishment
LPROC Manage procedure due to a reconfiguration failure and the
SWITC ment reestablishment is complete, the subsequent RRC
H connection reconfiguration may fail again. As a result,
the UE initiates an RRC connection reestablishment
procedure again. If this repeatedly happens, the UE
repeatedly initiates RRC connection reestablishment.
If this parameter is set to 0, the function of RRC
connection reestablishment protection is not used. If
this parameter is set to a value other than 0, the
eNodeB rejects the RRC connection reestablishment
request due to a reconfiguration failure from a UE
when the number of RRC connection reestablishment
requests initiated by the UE served by the eNodeB due
to a reconfiguration failure has exceeded the
parameter value within 1 minute. This parameter
applies only to LTE FDD and LTE TDD.
GUI Value Range: 0~6000
Unit: None
Actual Value Range: 0~6000
Default Value: 0
TimeAli TimeAli MOD LBFD-0 RRC Meaning: Indicates the length of the uplink time
gnment gnment TATIM 02007 Connect alignment timer for UEs in the cell. A UE is
Timer Timer ER TDLBF ion considered not time-aligned in the uplink if the timer
LST D-00201 Manage expires. This parameter applies only to LTE FDD and
TATIM 7 ment LTE TDD.
ER LEOFD- DRX GUI Value Range: SF500(500 subframes), SF750(750
111306/ Breathin subframes), SF1280(1280 subframes), SF1920(1920
TDLOF g Pilot subframes), SF2560(2560 subframes), SF5120(5120
D-12020 subframes), SF10240(10240 subframes),
RRC INFINITY(Infinity)
5 and
TDLOF DRX Unit: None
D-12110 Policy Actual Value Range: SF500, SF750, SF1280, SF1920,
5 for SF2560, SF5120, SF10240, INFINITY
Public Default Value: INFINITY(Infinity)
Safety
RrcCon UlSynTi MOD LBFD-0 RRC Meaning: Indicates the timer used to govern the
nStateTi mer RRCCO 02007/ Connect period in which the eNodeB maintains uplink
mer NNSTA TDLBF ion synchronization for UEs. After this timer expires, the
TETIM D-00200 Manage eNodeB does not send Timing Advance Command to
ER 7 ment the UE. This parameter does not take effect if it is set
LST to 0. That is, the eNodeB will constantly send Timing
RRCCO Advance Command to the UE to maintain uplink
NNSTA synchronization for the UE. If the QciParaEffectFlag
TETIM parameter in the GlobalProcSwitch MO is set to
ER ON(On), the UlSynTimerForQci parameter in the
QciPara MO, rather than this parameter takes effect.
This parameter applies only to LTE FDD and LTE
TDD.
GUI Value Range: 0~3600
Unit: s
Actual Value Range: 0~3600
Default Value: 180
QciPara UlSynTi ADD LBFD-0 RRC Meaning: Indicates the timer used to govern the
merFor QCIPA 02007/ Connect period in which the eNodeB maintains uplink
Qci RA TDLBF ion synchronization for UEs that have bearers of a QCI.
MOD D-00200 Manage After this timer expires, the eNodeB does not send the
QCIPA 7 ment Timing Advance Command to the UE. This parameter
RA LOFD-0 Enhance does not take effect if it is set to 0. That is, the
81218 d eNodeB will constantly send the Timing Advance
LST Command to the UE to maintain uplink
QCIPA TDLOF Extende
d QCI synchronization for the UE. If a UE has bearers of
RA D-11023 several QCIs, the eNodeB selects the longest uplink
0 Enhance synchronization timer of bearers with the highest QCI-
LTROF d specific priority specified by the UeInactiveTimerPri
D-11120 Extende parameter as the uplink synchronization timer for the
1/ d QCI UE. This parameter applies only to LTE FDD and LTE
TDLOF MCPTT TDD.
D-12110 QoS GUI Value Range: 0~3600
3 Manage
ment Unit: s
TDLOF
D-12110 RRC Actual Value Range: 0~3600
5 and Default Value: 180
DRX
Policy
for
Public
Safety
QciPara UeInacti ADD LBFD-0 RRC Meaning: Indicates the length of the UE inactivity
vityTim QCIPA 02007/ Connect timer for UEs that have entered DRX mode and have
erDynDr RA TDLBF ion bearers of the QCI when dynamic DRX is enabled. If
xQci MOD D-00200 Manage the eNodeB detects that a UE has neither received nor
QCIPA 7 ment sent data for a period exceeding the value of this
RA LOFD-0 Dynami parameter, the eNodeB releases the RRC connection
0110501 c DRX for this UE. If this parameter is set to a large value, the
LST amount of signaling is reduced but UE power
QCIPA / Enhance
TDLOF consumption increases. You are advised to set this
RA d parameter to a value greater than that of
D-00110 Extende
501 UlSynTimerDynDrx. In power saving mode, you are
d QCI advised to set this parameter significantly different to
LOFD-0 Enhance the value of the UlSynTimerDynDrx parameter, for
81218 d example a gap of 10 seconds, to avoid power
TDLOF Extende consumption increase due to the increase of signaling.
D-11023 d QCI If a UE has bearers of several QCIs, the eNodeB
0 Voice selects the longest UE Inactivity Timer of bearers with
LOFD-0 Characte the highest QCI-specific priority specified by the
81229/ ristic UeInactiveTimerPri parameter as the UE inactivity
TDLOF Awarene timer for the UE. This parameter applies only to LTE
D-08122 ss FDD and LTE TDD.
9 Scheduli GUI Value Range: 10~3600
LTROF ng Unit: s
D-11120 MCPTT Actual Value Range: 10~3600
1/ QoS
TDLOF Manage Default Value: 200
D-12110 ment
3 Congesti
TDLOF on
D-12110 Control
4 for
LTROF Public
D-11120 Safety
3/ RRC
TDLOF and
D-12110 DRX
5 Policy
for
Public
Safety
QciPara UeInacti ADD LBFD-0 RRC Meaning: Indicates the length of the UE inactivity
veTimer QCIPA 02007/ Connect timer for UEs that have bearers of a QCI. If the
ForQci RA TDLBF ion eNodeB detects that a UE has neither received nor
MOD D-00200 Manage sent data for a period exceeding the value of this
QCIPA 7 ment parameter, the eNodeB releases the RRC connection
RA LOFD-0 Enhance for this UE. If this parameter is set to 0, the UE
81218 d inactivity timer is not used. This parameter takes
LST effect only for UEs that will access the network after
QCIPA TDLOF Extende
d QCI the parameter is set. If a UE has bearers of several
RA D-11023 QCIs, the eNodeB selects the longest UE Inactivity
0 Enhance Timer of bearers with the highest QCI-specific
LOFD-0 d priority specified by the UeInactiveTimerPri
81229/ Extende parameter as the UE inactivity timer for the UE. This
TDLOF d QCI parameter applies only to LTE FDD and LTE TDD.
D-08122 Voice GUI Value Range: 0~3600
9 Characte
ristic Unit: s
TDLOF
D-08122 Awarene Actual Value Range: 0~3600
9 ss Default Value: 20
Scheduli
LTROF ng
D-11120
1/ Voice
TDLOF Characte
D-12110 ristic
3 Awarene
ss
TDLOF Scheduli
D-12110 ng
4
MCPTT
LTROF QoS
D-11120 Manage
3/ ment
TDLOF
D-12110 Congesti
5 on
Control
for
Public
Safety
RRC
and
DRX
Policy
for
Public
Safety
GlobalP QciPara MOD LBFD-0 Radio Meaning: Indicates whether the parameters
rocSwitc EffectFl GLOBA 02008 Bearer UeInactiveTimerForQci, UlSynTimerForQci,
h ag LPROC TDLBF Manage UeInactivityTimerDynDrxQci, and
SWITC D-00201 ment CiotUeInactiveTimer in the QciPara MO take effect.
H 7 DRX If this parameter is set to ON, the parameters
LST UeInactiveTimerForQci, UlSynTimerForQci,
LBFD-0 Mobility UeInactivityTimerDynDrxQci, and
GLOBA 02018/ Manage
LPROC CiotUeInactiveTimer in the QciPara MO take effect.
TDLBF ment If this parameter is set to OFF, the parameters
SWITC D-00201
H Coverag UeInactiveTimer, UlSynTimer, UeInactivityTimer-
8 e Based DynDrx, UeInactiveTimerQci1,
TDLBF Intra- UeInactTimerDynDrxQci1, and MTCUeInactiveTim-
D-00201 frequenc er in the RrcConnStateTimer MO take effect. This
801 y parameter applies only to LTE FDD and LTE TDD.
LBFD-0 Handov GUI Value Range: OFF(Off), ON(On)
0201802 er
Unit: None
/ Coverag
TDLBF e Based Actual Value Range: OFF, ON
D-00201 Inter- Default Value: ON(On)
802 frequenc
LBFD-0 y
0201805 Handov
/ er
TDLBF Service
D-00201 Based
805 Inter-
LOFD-0 frequenc
0301101 y
/ Handov
TDLOF er
D-00301 Transpo
101 rt
LOFD-0 Overboo
0301102 king
/ Transpo
TDLOF rt
D-00301 Differen
102 tiated
LOFD-0 Flow
0301103 Control
/ Transpo
TDLOF rt
D-00301 Resourc
103 e
Overloa
d
Control
CellAlg UEInact MOD LOFD-0 Voice Meaning: Indicates whether the UE inactivity timer
oSwitch iveTime CELLA 81229/ Characte for voice service UEs take effect according to QCI 1
rQCI1S LGOSW TDLOF ristic configurations.In non-dynamic DRX scenarios, if this
witch ITCH D-08122 Awarene switch is turned on, the QciPara.UeInactiveTimer-
LST 9 ss ForQci parameter corresponding to QCI of 1 takes
CELLA LBFD-0 Scheduli effect. If this switch is turned off, the
LGOSW 02007 ng QciPara.UeInactiveTimerForQci parameter
ITCH RRC corresponding to QCI of 5 instead of QCI of 1 takes
Connect effect.This parameter applies only to LTE FDD and
ion LTE TDD.
Manage GUI Value Range: OFF(Off), ON(On)
ment Unit: None
Actual Value Range: OFF, ON
Default Value: OFF(Off)
RrcCon UeInact MOD LBFD-0 RRC Meaning: Indicates the length of the UE Inactivity
nStateTi TimerD RRCCO 02007/ Connect Timer for UEs that have entered DRX mode and have
mer ynDrxQ NNSTA TDLBF ion QCI-1 services when dynamic DRX is enabled. If the
ci1 TETIM D-00200 Manage eNodeB detects that such a UE has neither received
ER 7 ment nor sent data for a period exceeding the value of this
LST LOFD-0 Dynami parameter, the eNodeB releases the RRC connection
RRCCO 0110501 c DRX for the UE. This parameter takes effect only for such
NNSTA UEs that will access the network after the parameter is
TETIM set. If the QciParaEffectFlag parameter in the
ER GlobalProcSwitch MO is set to ON(On), the
UeInactivityTimerDynDrxQci parameter in the
QciPara MO for QCI 1, rather than this parameter
takes effect. This parameter applies only to LTE FDD
and LTE TDD.
GUI Value Range: 10~3600
Unit: s
Actual Value Range: 10~3600
Default Value: 200
RrcCon UeInacti MOD LBFD-0 RRC Meaning: Indicates the length of the UE Inactivity
nStateTi veTimer RRCCO 02007/ Connect Timer for UEs having QCI 1 bearers. If the eNodeB
mer Qci1 NNSTA TDLBF ion detects that such a UE has neither received nor sent
TETIM D-00200 Manage data for a duration exceeding the value of this
ER 7 ment parameter, the eNodeB releases the RRC connection
LST LBFD-1 Support for the UE. If this parameter is set to 0, the UE
RRCCO 31107/ of inactivity timer is not used. This timer takes effect
NNSTA TDLBF VoLTE during the setup of QCI 1 bearers. During a handover
TETIM D-08110 or RRC connection reestablishment to a new cell, the
ER 1 eNodeB determines whether the timer takes effect
based on whether the UE has QCI 1 bearers. If yes,
the timer takes effect; otherwise, the timer does not
take effect. If the QciParaEffectFlag parameter is set
to ON(ON), this parameter does not take effect. In this
case, the CiotUeInactiveTimer parameter in the
QciPara MO for QCI 1 takes effect for eMTC UEs,
MTC UEs, and UEs with the RRC connection setup
cause delayToleran, and the UeInactiveTimerForQci
parameter in the QciPara MO for QCI 1 takes effect
for other types of UEs. This parameter applies only to
LTE FDD and LTE TDD.
GUI Value Range: 0~3600
Unit: s
Actual Value Range: 0~3600
Default Value: 20
RrcCon UeInacti MOD LBFD-0 RRC Meaning: Indicates the length of the UE Inactivity
nStateTi veTimer RRCCO 02007/ Connect Timer for UEs that do not have QCI-1 services. If the
mer NNSTA TDLBF ion eNodeB detects that such a UE has neither received
TETIM D-00200 Manage nor sent data for a period exceeding the value of this
ER 7 ment parameter, the eNodeB releases the RRC connection
LST for the UE. If this parameter is set to 0, the UE
RRCCO Inactivity Timer is not used. This parameter takes
NNSTA effect only for such UEs that will access the network
TETIM after the parameter is set. If the QciParaEffectFlag
ER parameter in the GlobalProcSwitch MO is set to
ON(On), the UeInactiveTimerForQci parameter in the
QciPara MO, rather than this parameter takes effect.
This parameter applies only to LTE FDD and LTE
TDD.
GUI Value Range: 0~3600
Unit: s
Actual Value Range: 0~3600
Default Value: 20
QciPara UeInacti ADD LBFD-0 RRC Meaning: Indicates the priority of the QCI-specific
veTimer QCIPA 02007/ Connect UE inactivity timer. A larger value of this parameter
Pri RA TDLBF ion indicates a higher priority. The eNodeB selects the
MOD D-00200 Manage longest UE inactivity timer with the highest QCI-
QCIPA 7 ment specific priority as the UE inactivity timer for UEs
RA LOFD-0 Voice running services with the specific QCI. The UE
81229/ Characte inactivity timer for QCI 69 is taken as the UE
LST inactivity timer for the MCPTT UEs.
QCIPA TDLOF ristic
RA D-08122 Awarene GUI Value Range: 0~255
9 ss Unit: None
Scheduli
ng Actual Value Range: 0~255
Default Value: 0
RrcCon UeInacti MOD LOFD-0 Dynami Meaning: Indicates the length of the UE Inactivity
nStateTi vityTim RRCCO 0110501 c DRX Timer for UEs that have entered DRX mode and have
mer erDynDr NNSTA / High- no QCI-1 services when dynamic DRX is enabled. If
x TETIM TDLOF Mobility the eNodeB detects that such a UE has neither
ER D-00110 - received nor sent data for a period exceeding the value
LST 501 Triggere of this parameter, the eNodeB releases the RRC
RRCCO LOFD-0 d Idle connection for the UE. If this parameter is set to a
NNSTA 0110502 Mode large value, the amount of signaling is reduced but UE
TETIM / power consumption increases. You are advised to set
RRC this parameter to a value greater than that of
ER TDLOF Connect
D-00110 UlSynTimerDynDrx. In power saving mode, you are
ion advised to set this parameter significantly different
502 Manage from the value of the UlSynTimerDynDrx parameter,
LBFD-0 ment for example a difference of 10 seconds, to avoid
02007 power consumption increase due to the increase of
signaling. If the QciParaEffectFlag parameter in the
GlobalProcSwitch MO is set to ON(On), the
UeInactivityTimerDynDrxQci parameter in the
QciPara MO, rather than this parameter takes effect.
This parameter applies only to LTE FDD and LTE
TDD.
GUI Value Range: 10~3600
Unit: s
Actual Value Range: 10~3600
Default Value: 200
GlobalP UeLink MOD LBFD-0 RRC Meaning: Indicates the UE link fault detection switch.
rocSwitc Abnorm GLOBA 02007/ Connect If this switch is turned on, link fault detection is
h alDetect LPROC TDLBF ion enabled for synchronized UEs. If this switch is turned
Switch SWITC D-00200 Manage off, link fault detection is not enabled for
H 7 ment synchronized UEs. This parameter applies only to
LST LTE FDD and LTE TDD.
GLOBA GUI Value Range: OFF(Off), ON(On)
LPROC Unit: None
SWITC
H Actual Value Range: OFF, ON
Default Value: OFF(Off)
ENodeB S1Mess MOD LBFD-0 RRC Meaning: Indicates the timer governing the period that
ConnSta ageWaiti ENODE 02007/ Connect the eNodeB waits for a response message from the
teTimer ngTimer BCONN TDLBF ion MME when the UE is running non-QCI1 services. If
STATET D-00200 Manage the UE is running services with a QCI of 1, the
IMER 7 ment S1MsgWaitingTimerQci1 parameter controls the
LST period that the eNodeB waits for a response message
ENODE from the MME.
BCONN GUI Value Range: 1~200
STATET Unit: s
IMER
Actual Value Range: 1~200
Default Value: 20
ENodeB S1Msg MOD LBFD-0 RRC Meaning: Indicates the timer governing the period that
ConnSta Waiting ENODE 02007/ Connect the eNodeB waits for a response message from the
teTimer TimerQ BCONN TDLBF ion MME when the UE is running services with the QCI
ci1 STATET D-00200 Manage of 1. If the timer expires, the eNodeB initiates a UE
IMER 7 ment context release over the S1 interface. This parameter
LST LBFD-1 Support applies only to LTE FDD and LTE TDD.
ENODE 31107/ of GUI Value Range: 1~200
BCONN TDLBF VoLTE Unit: s
STATET D-08110
IMER 1 Actual Value Range: 1~200
Default Value: 20
GlobalP UeRelC MOD LBFD-0 RRC Meaning: Indicates whether to perform the radio link
rocSwitc hkLostS GLOBA 02007/ Connect failure (RLF) detection for a UE when the RRC
h witch LPROC TDLBF ion connection for the UE is released because of UE
SWITC D-00200 Manage inactivity. This parameter applies only to LTE FDD
H 7 ment and LTE TDD.
LST GUI Value Range: OFF(Off), ON(On)
GLOBA Unit: None
LPROC
SWITC Actual Value Range: OFF, ON
H Default Value: OFF(Off)
GlobalP UeRelR MOD LBFD-0 RRC Meaning: Indicates the number of resynchronization
rocSwitc eSynTi GLOBA 02007/ Connect failures after which the UE release timer is started in
h mes LPROC TDLBF ion scenarios where the RRC connection is released for a
SWITC D-00200 Manage UE caused by resynchronization failure. This
H 7 ment parameter applies only to LTE FDD and LTE TDD.
LST GUI Value Range: r1(1), r2(2), r3(3), r4(4), r5(5),
GLOBA Infinity(Infinity)
LPROC Unit: None
SWITC
H Actual Value Range: r1, r2, r3, r4, r5, Infinity
Default Value: Infinity(Infinity)
CellQci TrafficR ADD LBFD-0 Radio Meaning: Indicates the time that the eNodeB waits to
Para elDelay CELLQ 02008/ Bearer release services with a specific QCI after the eNodeB
CIPAR TDLBF Manage detects that the radio link is abnormal. When the
A D-00200 ment eNodeB detects that the radio link is abnormal, the
MOD 8 eNodeB waits for the UE to initiate an RRC
CELLQ connection reestablishment procedure to restore
CIPAR services. If the waiting duration times out, the eNodeB
A releases the services. This parameter applies only to
LTE FDD and LTE TDD.
LST
CELLQ GUI Value Range: 0~65000
CIPAR Unit: ms
A Actual Value Range: 0~65000
Default Value: 30000
RlcPdcp AmPdcp ADD LBFD-0 Radio Meaning: Indicates the length of a PDCP sequence
ParaGro SnSize RLCPD 02008/ Bearer number in RLC AM. This parameter applies only to
up CPPAR TDLBF Manage LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: AmPdcpSnsize_12bits(12),
P 8 AmPdcpSnsize_15bits(15),
MOD AmPdcpSnsize_18bits(18)
RLCPD Unit: bit
CPPAR
AGROU Actual Value Range: AmPdcpSnsize_12bits,
P AmPdcpSnsize_15bits, AmPdcpSnsize_18bits
GlobalP QciUpd MOD TDLBF Radio Meaning: Indicates whether to perform parameter
rocSwitc ParaChe GLOBA D-00200 Bearer checks when the QCI value is updated. If this
h ckSwitc LPROC 8/ Manage parameter is set to ON, the function of checking
h SWITC LBFD-0 ment related parameters is enabled when the QCI value is
H 02008 updated. If this parameter is set to OFF, this function
LST is disabled when the QCI value is updated. This
GLOBA parameter applies only to LTE FDD and LTE TDD.
LPROC GUI Value Range: OFF(Off), ON(On)
SWITC Unit: None
H
Actual Value Range: OFF, ON
Default Value: OFF(Off)
RlcPdcp RlcPdcp ADD LBFD-0 Radio Meaning: Indicates the ID of the RLC/PDCP
ParaGro ParaGro RLCPD 02008/ Bearer parameter group.
up upId CPPAR TDLBF Manage GUI Value Range: 0~159
AGROU D-00200 ment
P 8 Unit: None
Data
LST MLBFD over Actual Value Range: 0~159
RLCPD -121002 User Default Value: None
CPPAR 05 Plane
AGROU
P
MOD
RLCPD
CPPAR
AGROU
P
RMV
RLCPD
CPPAR
AGROU
P
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the maximum number of RLC
ParaGro MaxRet RLCPD 02008/ Bearer ARQ retransmissions for the eNodeB, which limits
up xThresh CPPAR TDLBF Manage the maximum number of AM PDU retransmissions.
old AGROU D-00200 ment When the number of RLC ARQ retransmissions
P 8 reaches the parameter value, the eNodeB releases the
MOD UE. This option applies only to LTE FDD and LTE
RLCPD TDD.
CPPAR GUI Value Range: Maxretx_Threshold_t1(1),
AGROU Maxretx_Threshold_t2(2), Maxretx_Threshold_t3(3),
P Maxretx_Threshold_t4(4), Maxretx_Threshold_t6(6),
LST Maxretx_Threshold_t8(8),
RLCPD Maxretx_Threshold_t16(16),
CPPAR Maxretx_Threshold_t32(32)
AGROU Unit: None
P Actual Value Range: Maxretx_Threshold_t1,
Maxretx_Threshold_t2, Maxretx_Threshold_t3,
Maxretx_Threshold_t4, Maxretx_Threshold_t6,
Maxretx_Threshold_t8, Maxretx_Threshold_t16,
Maxretx_Threshold_t32
Default Value: Maxretx_Threshold_t32(32)
RlcPdcp UePollB ADD LBFD-0 Radio Meaning: Indicates the UE-specific data volume
ParaGro yte RLCPD 02008/ Bearer threshold of PDUs to trigger polling. When the
up CPPAR TDLBF Manage transmitted data volume reaches the value of this
AGROU D-00200 ment parameter, the Poll flag is set in the PDU header. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: PollByte_kb25(25 kBytes),
RLCPD PollByte_kb50(50 kBytes), PollByte_kb75(75
CPPAR kBytes), PollByte_kb100(100 kBytes),
AGROU PollByte_kb125(125 kBytes), PollByte_kb250(250
P kBytes), PollByte_kb375(375 kBytes),
LST PollByte_kb500(500 kBytes), PollByte_kb750(750
RLCPD kBytes), PollByte_kb1000(1000 kBytes),
CPPAR PollByte_kb1250(1250 kBytes),
AGROU PollByte_kb1500(1500 kBytes),
P PollByte_kb2000(2000 kBytes),
PollByte_kb3000(3000 kBytes),
PollByte_infinity(infinite kBytes)
Unit: byte
Actual Value Range: PollByte_kb25, PollByte_kb50,
PollByte_kb75, PollByte_kb100, PollByte_kb125,
PollByte_kb250, PollByte_kb375, PollByte_kb500,
PollByte_kb750, PollByte_kb1000, PollByte_kb1250,
PollByte_kb1500, PollByte_kb2000,
PollByte_kb3000, PollByte_infinity
Default Value: PollByte_kb25(25 kBytes)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the eNodeB-specific data volume
ParaGro PollByte RLCPD 02008/ Bearer threshold of PDUs to trigger polling. When the
up CPPAR TDLBF Manage transmitted data volume reaches the value of this
AGROU D-00200 ment parameter, the Poll flag is set in the PDU header. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: PollByte_kb25(25 kBytes),
RLCPD PollByte_kb50(50 kBytes), PollByte_kb75(75
CPPAR kBytes), PollByte_kb100(100 kBytes),
AGROU PollByte_kb125(125 kBytes), PollByte_kb250(250
P kBytes), PollByte_kb375(375 kBytes),
LST PollByte_kb500(500 kBytes), PollByte_kb750(750
RLCPD kBytes), PollByte_kb1000(1000 kBytes),
CPPAR PollByte_kb1250(1250 kBytes),
AGROU PollByte_kb1500(1500 kBytes),
P PollByte_kb2000(2000 kBytes),
PollByte_kb3000(3000 kBytes),
PollByte_infinity(infinite kBytes)
Unit: byte
Actual Value Range: PollByte_kb25, PollByte_kb50,
PollByte_kb75, PollByte_kb100, PollByte_kb125,
PollByte_kb250, PollByte_kb375, PollByte_kb500,
PollByte_kb750, PollByte_kb1000, PollByte_kb1250,
PollByte_kb1500, PollByte_kb2000,
PollByte_kb3000, PollByte_infinity
Default Value: PollByte_kb25(25 kBytes)
RlcPdcp UePollP ADD LBFD-0 Radio Meaning: Indicates the UE-specific number of PDUs
ParaGro du RLCPD 02008/ Bearer to trigger polling. When the transmitted number of
up CPPAR TDLBF Manage PDUs reaches the value of this parameter, the Poll flag
AGROU D-00200 ment is set in the PDU header. This parameter applies only
P 8 to LTE FDD and LTE TDD.
MOD GUI Value Range: PollPdu_p4(4 PDUs),
RLCPD PollPdu_p8(8 PDUs), PollPdu_p16(16 PDUs),
CPPAR PollPdu_p32(32 PDUs), PollPdu_p64(64 PDUs),
AGROU PollPdu_p128(128 PDUs), PollPdu_p256(256 PDUs),
P PollPdu_Infinity(infinite PDUs)
LST Unit: None
RLCPD Actual Value Range: PollPdu_p4, PollPdu_p8,
CPPAR PollPdu_p16, PollPdu_p32, PollPdu_p64,
AGROU PollPdu_p128, PollPdu_p256, PollPdu_Infinity
P
Default Value: PollPdu_p32(32 PDUs)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the eNodeB-specific number of
ParaGro PollPdu RLCPD 02008/ Bearer PDUs to trigger polling. When the transmitted number
up CPPAR TDLBF Manage of PDUs reaches the value of this parameter, the Poll
AGROU D-00200 ment flag is set in the PDU header. This parameter applies
P 8 only to LTE FDD and LTE TDD.
MOD GUI Value Range: PollPdu_p4(4 PDUs),
RLCPD PollPdu_p8(8 PDUs), PollPdu_p16(16 PDUs),
CPPAR PollPdu_p32(32 PDUs), PollPdu_p64(64 PDUs),
AGROU PollPdu_p128(128 PDUs), PollPdu_p256(256 PDUs),
P PollPdu_Infinity(infinite PDUs)
LST Unit: None
RLCPD Actual Value Range: PollPdu_p4, PollPdu_p8,
CPPAR PollPdu_p16, PollPdu_p32, PollPdu_p64,
AGROU PollPdu_p128, PollPdu_p256, PollPdu_Infinity
P
Default Value: PollPdu_p32(32 PDUs)
RlcPdcp UePollR ADD LBFD-0 Radio Meaning: Indicates the length of the Polling PDU
ParaGro etransmi RLCPD 02008/ Bearer retransmission timer for the UE.This parameter
up tTimer CPPAR TDLBF Manage applies only to LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: Tpollretrans_m5(5),
P 8 eMTC Tpollretrans_m10(10), Tpollretrans_m15(15),
MOD MLOFD Introduc Tpollretrans_m20(20), Tpollretrans_m25(25),
RLCPD -121280 tion Tpollretrans_m30(30), Tpollretrans_m35(35),
CPPAR / Tpollretrans_m40(40), Tpollretrans_m45(45),
AGROU TDLEO Tpollretrans_m50(50), Tpollretrans_m55(55),
P FD-121 Tpollretrans_m60(60), Tpollretrans_m65(65),
LST 611 Tpollretrans_m70(70), Tpollretrans_m75(75),
RLCPD Tpollretrans_m80(80), Tpollretrans_m85(85),
CPPAR Tpollretrans_m90(90), Tpollretrans_m95(95),
AGROU Tpollretrans_m100(100), Tpollretrans_m105(105),
P Tpollretrans_m110(110), Tpollretrans_m115(115),
Tpollretrans_m120(120), Tpollretrans_m125(125),
Tpollretrans_m130(130), Tpollretrans_m135(135),
Tpollretrans_m140(140), Tpollretrans_m145(145),
Tpollretrans_m150(150), Tpollretrans_m155(155),
Tpollretrans_m160(160), Tpollretrans_m165(165),
Tpollretrans_m170(170), Tpollretrans_m175(175),
Tpollretrans_m180(180), Tpollretrans_m185(185),
Tpollretrans_m190(190), Tpollretrans_m195(195),
Tpollretrans_m200(200), Tpollretrans_m205(205),
Tpollretrans_m210(210), Tpollretrans_m215(215),
Tpollretrans_m220(220), Tpollretrans_m225(225),
Tpollretrans_m230(230), Tpollretrans_m235(235),
Tpollretrans_m240(240), Tpollretrans_m245(245),
Tpollretrans_m250(250), Tpollretrans_m300(300),
Tpollretrans_m350(350), Tpollretrans_m400(400),
Tpollretrans_m450(450), Tpollretrans_m500(500),
Tpollretrans_m800(800), Tpollretrans_m1000(1000),
Tpollretrans_m2000(2000),
Tpollretrans_m4000(4000)
Unit: ms
Actual Value Range: Tpollretrans_m5,
Tpollretrans_m10, Tpollretrans_m15,
Tpollretrans_m20, Tpollretrans_m25,
Tpollretrans_m30, Tpollretrans_m35,
Tpollretrans_m40, Tpollretrans_m45,
Tpollretrans_m50, Tpollretrans_m55,
Tpollretrans_m60, Tpollretrans_m65,
Tpollretrans_m70, Tpollretrans_m75,
Tpollretrans_m80, Tpollretrans_m85,
Tpollretrans_m90, Tpollretrans_m95,
Tpollretrans_m100, Tpollretrans_m105,
Tpollretrans_m110, Tpollretrans_m115,
Tpollretrans_m120, Tpollretrans_m125,
Tpollretrans_m130, Tpollretrans_m135,
Tpollretrans_m140, Tpollretrans_m145,
Tpollretrans_m150, Tpollretrans_m155,
Tpollretrans_m160, Tpollretrans_m165,
Tpollretrans_m170, Tpollretrans_m175,
Tpollretrans_m180, Tpollretrans_m185,
Tpollretrans_m190, Tpollretrans_m195,
Tpollretrans_m200, Tpollretrans_m205,
Tpollretrans_m210, Tpollretrans_m215,
Tpollretrans_m220, Tpollretrans_m225,
Tpollretrans_m230, Tpollretrans_m235,
Tpollretrans_m240, Tpollretrans_m245,
Tpollretrans_m250, Tpollretrans_m300,
Tpollretrans_m350, Tpollretrans_m400,
Tpollretrans_m450, Tpollretrans_m500,
Tpollretrans_m800, Tpollretrans_m1000,
Tpollretrans_m2000, Tpollretrans_m4000
Default Value: Tpollretrans_m40(40)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the length of the Polling PDU
ParaGro PollRetr RLCPD 02008/ Bearer retransmission timer for the eNodeB. This parameter
up ansmitTi CPPAR TDLBF Manage applies only to LTE FDD and LTE TDD.
mer AGROU D-00200 ment GUI Value Range: Tpollretrans_m5(5),
P 8 eMTC Tpollretrans_m10(10), Tpollretrans_m15(15),
MOD MLOFD Introduc Tpollretrans_m20(20), Tpollretrans_m25(25),
RLCPD -121280 tion Tpollretrans_m30(30), Tpollretrans_m35(35),
CPPAR / Tpollretrans_m40(40), Tpollretrans_m45(45),
AGROU TDLEO Tpollretrans_m50(50), Tpollretrans_m55(55),
P FD-121 Tpollretrans_m60(60), Tpollretrans_m65(65),
LST 611 Tpollretrans_m70(70), Tpollretrans_m75(75),
RLCPD Tpollretrans_m80(80), Tpollretrans_m85(85),
CPPAR Tpollretrans_m90(90), Tpollretrans_m95(95),
AGROU Tpollretrans_m100(100), Tpollretrans_m105(105),
P Tpollretrans_m110(110), Tpollretrans_m115(115),
Tpollretrans_m120(120), Tpollretrans_m125(125),
Tpollretrans_m130(130), Tpollretrans_m135(135),
Tpollretrans_m140(140), Tpollretrans_m145(145),
Tpollretrans_m150(150), Tpollretrans_m155(155),
Tpollretrans_m160(160), Tpollretrans_m165(165),
Tpollretrans_m170(170), Tpollretrans_m175(175),
Tpollretrans_m180(180), Tpollretrans_m185(185),
Tpollretrans_m190(190), Tpollretrans_m195(195),
Tpollretrans_m200(200), Tpollretrans_m205(205),
Tpollretrans_m210(210), Tpollretrans_m215(215),
Tpollretrans_m220(220), Tpollretrans_m225(225),
Tpollretrans_m230(230), Tpollretrans_m235(235),
Tpollretrans_m240(240), Tpollretrans_m245(245),
Tpollretrans_m250(250), Tpollretrans_m300(300),
Tpollretrans_m350(350), Tpollretrans_m400(400),
Tpollretrans_m450(450), Tpollretrans_m500(500),
Tpollretrans_m800(800), Tpollretrans_m1000(1000),
Tpollretrans_m2000(2000),
Tpollretrans_m4000(4000)
Unit: ms
Actual Value Range: Tpollretrans_m5,
Tpollretrans_m10, Tpollretrans_m15,
Tpollretrans_m20, Tpollretrans_m25,
Tpollretrans_m30, Tpollretrans_m35,
Tpollretrans_m40, Tpollretrans_m45,
Tpollretrans_m50, Tpollretrans_m55,
Tpollretrans_m60, Tpollretrans_m65,
Tpollretrans_m70, Tpollretrans_m75,
Tpollretrans_m80, Tpollretrans_m85,
Tpollretrans_m90, Tpollretrans_m95,
Tpollretrans_m100, Tpollretrans_m105,
Tpollretrans_m110, Tpollretrans_m115,
Tpollretrans_m120, Tpollretrans_m125,
Tpollretrans_m130, Tpollretrans_m135,
Tpollretrans_m140, Tpollretrans_m145,
Tpollretrans_m150, Tpollretrans_m155,
Tpollretrans_m160, Tpollretrans_m165,
Tpollretrans_m170, Tpollretrans_m175,
Tpollretrans_m180, Tpollretrans_m185,
Tpollretrans_m190, Tpollretrans_m195,
Tpollretrans_m200, Tpollretrans_m205,
Tpollretrans_m210, Tpollretrans_m215,
Tpollretrans_m220, Tpollretrans_m225,
Tpollretrans_m230, Tpollretrans_m235,
Tpollretrans_m240, Tpollretrans_m245,
Tpollretrans_m250, Tpollretrans_m300,
Tpollretrans_m350, Tpollretrans_m400,
Tpollretrans_m450, Tpollretrans_m500,
Tpollretrans_m800, Tpollretrans_m1000,
Tpollretrans_m2000, Tpollretrans_m4000
Default Value: Tpollretrans_m50(50)
RlcPdcp UeStatu ADD LBFD-0 Radio Meaning: Indicates the length of the UE-specific timer
ParaGro sProhibi RLCPD 02008/ Bearer for prohibiting status reporting from the receiver in
up tTimer CPPAR TDLBF Manage AM. This parameter applies only to LTE FDD and
AGROU D-00200 ment LTE TDD.
P 8 eMTC GUI Value Range: Tstatprohibit_m0(0),
MOD MLOFD Introduc Tstatprohibit_m5(5), Tstatprohibit_m10(10),
RLCPD -121280 tion Tstatprohibit_m15(15), Tstatprohibit_m20(20),
CPPAR / Tstatprohibit_m25(25), Tstatprohibit_m30(30),
AGROU TDLEO Tstatprohibit_m35(35), Tstatprohibit_m40(40),
P FD-121 Tstatprohibit_m45(45), Tstatprohibit_m50(50),
LST 611 Tstatprohibit_m55(55), Tstatprohibit_m60(60),
RLCPD Tstatprohibit_m65(65), Tstatprohibit_m70(70),
CPPAR Tstatprohibit_m75(75), Tstatprohibit_m80(80),
AGROU Tstatprohibit_m85(85), Tstatprohibit_m90(90),
P Tstatprohibit_m95(95), Tstatprohibit_m100(100),
Tstatprohibit_m105(105), Tstatprohibit_m110(110),
Tstatprohibit_m115(115), Tstatprohibit_m120(120),
Tstatprohibit_m125(125), Tstatprohibit_m130(130),
Tstatprohibit_m135(135), Tstatprohibit_m140(140),
Tstatprohibit_m145(145), Tstatprohibit_m150(150),
Tstatprohibit_m155(155), Tstatprohibit_m160(160),
Tstatprohibit_m165(165), Tstatprohibit_m170(170),
Tstatprohibit_m175(175), Tstatprohibit_m180(180),
Tstatprohibit_m185(185), Tstatprohibit_m190(190),
Tstatprohibit_m195(195), Tstatprohibit_m200(200),
Tstatprohibit_m205(205), Tstatprohibit_m210(210),
Tstatprohibit_m215(215), Tstatprohibit_m220(220),
Tstatprohibit_m225(225), Tstatprohibit_m230(230),
Tstatprohibit_m235(235), Tstatprohibit_m240(240),
Tstatprohibit_m245(245), Tstatprohibit_m250(250),
Tstatprohibit_m300(300), Tstatprohibit_m350(350),
Tstatprohibit_m400(400), Tstatprohibit_m450(450),
Tstatprohibit_m500(500), Tstatprohibit_m800(800),
Tstatprohibit_m1000(1000),
Tstatprohibit_m1200(1200),
Tstatprohibit_m1600(1600),
Tstatprohibit_m2000(2000),
Tstatprohibit_m2400(2400)
Unit: ms
Actual Value Range: Tstatprohibit_m0,
Tstatprohibit_m5, Tstatprohibit_m10,
Tstatprohibit_m15, Tstatprohibit_m20,
Tstatprohibit_m25, Tstatprohibit_m30,
Tstatprohibit_m35, Tstatprohibit_m40,
Tstatprohibit_m45, Tstatprohibit_m50,
Tstatprohibit_m55, Tstatprohibit_m60,
Tstatprohibit_m65, Tstatprohibit_m70,
Tstatprohibit_m75, Tstatprohibit_m80,
Tstatprohibit_m85, Tstatprohibit_m90,
Tstatprohibit_m95, Tstatprohibit_m100,
Tstatprohibit_m105, Tstatprohibit_m110,
Tstatprohibit_m115, Tstatprohibit_m120,
Tstatprohibit_m125, Tstatprohibit_m130,
Tstatprohibit_m135, Tstatprohibit_m140,
Tstatprohibit_m145, Tstatprohibit_m150,
Tstatprohibit_m155, Tstatprohibit_m160,
Tstatprohibit_m165, Tstatprohibit_m170,
Tstatprohibit_m175, Tstatprohibit_m180,
Tstatprohibit_m185, Tstatprohibit_m190,
Tstatprohibit_m195, Tstatprohibit_m200,
Tstatprohibit_m205, Tstatprohibit_m210,
Tstatprohibit_m215, Tstatprohibit_m220,
Tstatprohibit_m225, Tstatprohibit_m230,
Tstatprohibit_m235, Tstatprohibit_m240,
Tstatprohibit_m245, Tstatprohibit_m250,
Tstatprohibit_m300, Tstatprohibit_m350,
Tstatprohibit_m400, Tstatprohibit_m450,
Tstatprohibit_m500, Tstatprohibit_m800,
Tstatprohibit_m1000, Tstatprohibit_m1200,
Tstatprohibit_m1600, Tstatprohibit_m2000,
Tstatprohibit_m2400
Default Value: Tstatprohibit_m50(50)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the length of the eNodeB-specific
ParaGro StatusPr RLCPD 02008/ Bearer timer for prohibiting status reporting from the receiver
up ohibitTi CPPAR TDLBF Manage in AM. This parameter applies only to LTE FDD and
mer AGROU D-00200 ment LTE TDD.
P 8 eMTC GUI Value Range: Tstatprohibit_m0(0),
MOD MLOFD Introduc Tstatprohibit_m5(5), Tstatprohibit_m10(10),
RLCPD -121280 tion Tstatprohibit_m15(15), Tstatprohibit_m20(20),
CPPAR / Tstatprohibit_m25(25), Tstatprohibit_m30(30),
AGROU TDLEO Tstatprohibit_m35(35), Tstatprohibit_m40(40),
P FD-121 Tstatprohibit_m45(45), Tstatprohibit_m50(50),
LST 611 Tstatprohibit_m55(55), Tstatprohibit_m60(60),
RLCPD Tstatprohibit_m65(65), Tstatprohibit_m70(70),
CPPAR Tstatprohibit_m75(75), Tstatprohibit_m80(80),
AGROU Tstatprohibit_m85(85), Tstatprohibit_m90(90),
P Tstatprohibit_m95(95), Tstatprohibit_m100(100),
Tstatprohibit_m105(105), Tstatprohibit_m110(110),
Tstatprohibit_m115(115), Tstatprohibit_m120(120),
Tstatprohibit_m125(125), Tstatprohibit_m130(130),
Tstatprohibit_m135(135), Tstatprohibit_m140(140),
Tstatprohibit_m145(145), Tstatprohibit_m150(150),
Tstatprohibit_m155(155), Tstatprohibit_m160(160),
Tstatprohibit_m165(165), Tstatprohibit_m170(170),
Tstatprohibit_m175(175), Tstatprohibit_m180(180),
Tstatprohibit_m185(185), Tstatprohibit_m190(190),
Tstatprohibit_m195(195), Tstatprohibit_m200(200),
Tstatprohibit_m205(205), Tstatprohibit_m210(210),
Tstatprohibit_m215(215), Tstatprohibit_m220(220),
Tstatprohibit_m225(225), Tstatprohibit_m230(230),
Tstatprohibit_m235(235), Tstatprohibit_m240(240),
Tstatprohibit_m245(245), Tstatprohibit_m250(250),
Tstatprohibit_m300(300), Tstatprohibit_m350(350),
Tstatprohibit_m400(400), Tstatprohibit_m450(450),
Tstatprohibit_m500(500), Tstatprohibit_m800(800),
Tstatprohibit_m1000(1000),
Tstatprohibit_m1200(1200),
Tstatprohibit_m1600(1600),
Tstatprohibit_m2000(2000),
Tstatprohibit_m2400(2400)
Unit: ms
Actual Value Range: Tstatprohibit_m0,
Tstatprohibit_m5, Tstatprohibit_m10,
Tstatprohibit_m15, Tstatprohibit_m20,
Tstatprohibit_m25, Tstatprohibit_m30,
Tstatprohibit_m35, Tstatprohibit_m40,
Tstatprohibit_m45, Tstatprohibit_m50,
Tstatprohibit_m55, Tstatprohibit_m60,
Tstatprohibit_m65, Tstatprohibit_m70,
Tstatprohibit_m75, Tstatprohibit_m80,
Tstatprohibit_m85, Tstatprohibit_m90,
Tstatprohibit_m95, Tstatprohibit_m100,
Tstatprohibit_m105, Tstatprohibit_m110,
Tstatprohibit_m115, Tstatprohibit_m120,
Tstatprohibit_m125, Tstatprohibit_m130,
Tstatprohibit_m135, Tstatprohibit_m140,
Tstatprohibit_m145, Tstatprohibit_m150,
Tstatprohibit_m155, Tstatprohibit_m160,
Tstatprohibit_m165, Tstatprohibit_m170,
Tstatprohibit_m175, Tstatprohibit_m180,
Tstatprohibit_m185, Tstatprohibit_m190,
Tstatprohibit_m195, Tstatprohibit_m200,
Tstatprohibit_m205, Tstatprohibit_m210,
Tstatprohibit_m215, Tstatprohibit_m220,
Tstatprohibit_m225, Tstatprohibit_m230,
Tstatprohibit_m235, Tstatprohibit_m240,
Tstatprohibit_m245, Tstatprohibit_m250,
Tstatprohibit_m300, Tstatprohibit_m350,
Tstatprohibit_m400, Tstatprohibit_m450,
Tstatprohibit_m500, Tstatprohibit_m800,
Tstatprohibit_m1000, Tstatprohibit_m1200,
Tstatprohibit_m1600, Tstatprohibit_m2000,
Tstatprohibit_m2400
Default Value: Tstatprohibit_m40(40)
RlcPdcp UeAmR ADD LBFD-0 Radio Meaning: Indicates the length of the UE-specific timer
ParaGro eorderin RLCPD 02008/ Bearer for reordering at the receiver in AM. This parameter
up gTimer CPPAR TDLBF Manage applies only to LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: Treordering_m0(0),
P 8 eMTC Treordering_m5(5), Treordering_m10(10),
MOD MLOFD Introduc Treordering_m15(15), Treordering_m20(20),
RLCPD -121280 tion Treordering_m25(25), Treordering_m30(30),
CPPAR / Treordering_m35(35), Treordering_m40(40),
AGROU TDLEO Treordering_m45(45), Treordering_m50(50),
P FD-121 Treordering_m55(55), Treordering_m60(60),
LST 611 Treordering_m65(65), Treordering_m70(70),
RLCPD Treordering_m75(75), Treordering_m80(80),
CPPAR Treordering_m85(85), Treordering_m90(90),
AGROU Treordering_m95(95), Treordering_m100(100),
P Treordering_m110(110), Treordering_m120(120),
Treordering_m130(130), Treordering_m140(140),
Treordering_m150(150), Treordering_m160(160),
Treordering_m170(170), Treordering_m180(180),
Treordering_m190(190), Treordering_m200(200),
Treordering_m1600(1600)
Unit: ms
Actual Value Range: Treordering_m0,
Treordering_m5, Treordering_m10, Treordering_m15,
Treordering_m20, Treordering_m25,
Treordering_m30, Treordering_m35,
Treordering_m40, Treordering_m45,
Treordering_m50, Treordering_m55,
Treordering_m60, Treordering_m65,
Treordering_m70, Treordering_m75,
Treordering_m80, Treordering_m85,
Treordering_m90, Treordering_m95,
Treordering_m100, Treordering_m110,
Treordering_m120, Treordering_m130,
Treordering_m140, Treordering_m150,
Treordering_m160, Treordering_m170,
Treordering_m180, Treordering_m190,
Treordering_m200, Treordering_m1600
Default Value: Treordering_m50(50)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the length of the eNodeB-specific
ParaGro AmReor RLCPD 02008/ Bearer timer for reordering at the receiver in AM. This
up deringTi CPPAR TDLBF Manage parameter applies only to LTE FDD and LTE TDD.
mer AGROU D-00200 ment GUI Value Range: Treordering_m0(0),
P 8 VoLTE Treordering_m5(5), Treordering_m10(10),
MOD LOFD-1 Coverag Treordering_m15(15), Treordering_m20(20),
RLCPD 20204/ e Treordering_m25(25), Treordering_m30(30),
CPPAR TDLOF Enhance Treordering_m35(35), Treordering_m40(40),
AGROU D-12020 ment Treordering_m45(45), Treordering_m50(50),
P 3 eMTC Treordering_m55(55), Treordering_m60(60),
LST MLOFD Introduc Treordering_m65(65), Treordering_m70(70),
RLCPD -121280 tion Treordering_m75(75), Treordering_m80(80),
CPPAR / Treordering_m85(85), Treordering_m90(90),
AGROU TDLEO Treordering_m95(95), Treordering_m100(100),
P FD-121 Treordering_m110(110), Treordering_m120(120),
611 Treordering_m130(130), Treordering_m140(140),
Treordering_m150(150), Treordering_m160(160),
Treordering_m170(170), Treordering_m180(180),
Treordering_m190(190), Treordering_m200(200),
Treordering_m1600(1600)
Unit: ms
Actual Value Range: Treordering_m0,
Treordering_m5, Treordering_m10, Treordering_m15,
Treordering_m20, Treordering_m25,
Treordering_m30, Treordering_m35,
Treordering_m40, Treordering_m45,
Treordering_m50, Treordering_m55,
Treordering_m60, Treordering_m65,
Treordering_m70, Treordering_m75,
Treordering_m80, Treordering_m85,
Treordering_m90, Treordering_m95,
Treordering_m100, Treordering_m110,
Treordering_m120, Treordering_m130,
Treordering_m140, Treordering_m150,
Treordering_m160, Treordering_m170,
Treordering_m180, Treordering_m190,
Treordering_m200, Treordering_m1600
Default Value: Treordering_m40(40)
RlcPdcp UeUmR ADD LBFD-0 Radio Meaning: Indicates the length of the UE-specific timer
ParaGro eorderin RLCPD 02008/ Bearer for reordering at the receiver in UM. This parameter
up gTimer CPPAR TDLBF Manage applies only to LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: Treordering_m0(0),
P 8 eMTC Treordering_m5(5), Treordering_m10(10),
MOD MLOFD Introduc Treordering_m15(15), Treordering_m20(20),
RLCPD -121280 tion Treordering_m25(25), Treordering_m30(30),
CPPAR / Treordering_m35(35), Treordering_m40(40),
AGROU TDLEO Treordering_m45(45), Treordering_m50(50),
P FD-121 Treordering_m55(55), Treordering_m60(60),
LST 611 Treordering_m65(65), Treordering_m70(70),
RLCPD Treordering_m75(75), Treordering_m80(80),
CPPAR Treordering_m85(85), Treordering_m90(90),
AGROU Treordering_m95(95), Treordering_m100(100),
P Treordering_m110(110), Treordering_m120(120),
Treordering_m130(130), Treordering_m140(140),
Treordering_m150(150), Treordering_m160(160),
Treordering_m170(170), Treordering_m180(180),
Treordering_m190(190), Treordering_m200(200),
Treordering_m1600(1600)
Unit: ms
Actual Value Range: Treordering_m0,
Treordering_m5, Treordering_m10, Treordering_m15,
Treordering_m20, Treordering_m25,
Treordering_m30, Treordering_m35,
Treordering_m40, Treordering_m45,
Treordering_m50, Treordering_m55,
Treordering_m60, Treordering_m65,
Treordering_m70, Treordering_m75,
Treordering_m80, Treordering_m85,
Treordering_m90, Treordering_m95,
Treordering_m100, Treordering_m110,
Treordering_m120, Treordering_m130,
Treordering_m140, Treordering_m150,
Treordering_m160, Treordering_m170,
Treordering_m180, Treordering_m190,
Treordering_m200, Treordering_m1600
Default Value: Treordering_m50(50)
RlcPdcp ENodeB ADD LBFD-0 Radio Meaning: Indicates the length of the eNodeB-specific
ParaGro UmReor RLCPD 02008/ Bearer timer for reordering at the receiver in UM. This
up deringTi CPPAR TDLBF Manage parameter applies only to LTE FDD and LTE TDD.
mer AGROU D-00200 ment GUI Value Range: Treordering_m0(0),
P 8 VoLTE Treordering_m5(5), Treordering_m10(10),
MOD LOFD-1 Coverag Treordering_m15(15), Treordering_m20(20),
RLCPD 20204/ e Treordering_m25(25), Treordering_m30(30),
CPPAR TDLOF Enhance Treordering_m35(35), Treordering_m40(40),
AGROU D-12020 ment Treordering_m45(45), Treordering_m50(50),
P 3 eMTC Treordering_m55(55), Treordering_m60(60),
LST MLOFD Introduc Treordering_m65(65), Treordering_m70(70),
RLCPD -121280 tion Treordering_m75(75), Treordering_m80(80),
CPPAR / Treordering_m85(85), Treordering_m90(90),
AGROU TDLEO Treordering_m95(95), Treordering_m100(100),
P FD-121 Treordering_m110(110), Treordering_m120(120),
611 Treordering_m130(130), Treordering_m140(140),
Treordering_m150(150), Treordering_m160(160),
Treordering_m170(170), Treordering_m180(180),
Treordering_m190(190), Treordering_m200(200),
Treordering_m1600(1600)
Unit: ms
Actual Value Range: Treordering_m0,
Treordering_m5, Treordering_m10, Treordering_m15,
Treordering_m20, Treordering_m25,
Treordering_m30, Treordering_m35,
Treordering_m40, Treordering_m45,
Treordering_m50, Treordering_m55,
Treordering_m60, Treordering_m65,
Treordering_m70, Treordering_m75,
Treordering_m80, Treordering_m85,
Treordering_m90, Treordering_m95,
Treordering_m100, Treordering_m110,
Treordering_m120, Treordering_m130,
Treordering_m140, Treordering_m150,
Treordering_m160, Treordering_m170,
Treordering_m180, Treordering_m190,
Treordering_m200, Treordering_m1600
Default Value: Treordering_m40(40)
RlcPdcp PdcpStat ADD LBFD-0 Radio Meaning: Indicates whether a PDCP status report is
ParaGro usRptRe RLCPD 02008/ Bearer required upon handover in AM. This parameter
up q CPPAR TDLBF Manage applies only to LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: FALSE(FALSE), TRUE(TRUE)
P 8
Unit: None
MOD
RLCPD Actual Value Range: FALSE, TRUE
CPPAR Default Value: TRUE(TRUE)
AGROU
P
LST
RLCPD
CPPAR
AGROU
P
RlcPdcp eNodeB ADD LBFD-0 Radio Meaning: Indicates the length of the Polling PDU
ParaGro PollRtrT RLCPD 02008/ Bearer retransmission timer for the eNodeB when the
up imerPres CPPAR TDLBF Manage RlcParaAdaptSwitch parameter is set to ON and the
et AGROU D-00200 ment number of UEs on the network is large. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: m5, m10, m15, m20, m25, m30,
RLCPD m35, m40, m45, m50, m55, m60, m65, m70, m75,
CPPAR m80, m85, m90, m95, m100, m105, m110, m115,
AGROU m120, m125, m130, m135, m140, m145, m150,
P m155, m160, m165, m170, m175, m180, m185,
LST m190, m195, m200, m205, m210, m215, m220,
RLCPD m225, m230, m235, m240, m245, m250, m300,
CPPAR m350, m400, m450, m500
AGROU Unit: ms
P Actual Value Range: m5, m10, m15, m20, m25, m30,
m35, m40, m45, m50, m55, m60, m65, m70, m75,
m80, m85, m90, m95, m100, m105, m110, m115,
m120, m125, m130, m135, m140, m145, m150,
m155, m160, m165, m170, m175, m180, m185,
m190, m195, m200, m205, m210, m215, m220,
m225, m230, m235, m240, m245, m250, m300,
m350, m400, m450, m500
Default Value: m200
RlcPdcp eNodeB ADD LBFD-0 Radio Meaning: Indicates the length of the eNodeB-specific
ParaGro StatProh RLCPD 02008/ Bearer timer for prohibiting status reporting from the receiver
up TimerPr CPPAR TDLBF Manage when the RlcParaAdaptSwitch parameter is set to ON
eset AGROU D-00200 ment and the number of UEs on the network is large. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: m0, m5, m10, m15, m20, m25,
RLCPD m30, m35, m40, m45, m50, m55, m60, m65, m70,
CPPAR m75, m80, m85, m90, m95, m100, m105, m110,
AGROU m115, m120, m125, m130, m135, m140, m145,
P m150, m155, m160, m165, m170, m175, m180,
LST m185, m190, m195, m200, m205, m210, m215,
RLCPD m220, m225, m230, m235, m240, m245, m250,
CPPAR m300, m350, m400, m450, m500
AGROU Unit: ms
P Actual Value Range: m0, m5, m10, m15, m20, m25,
m30, m35, m40, m45, m50, m55, m60, m65, m70,
m75, m80, m85, m90, m95, m100, m105, m110,
m115, m120, m125, m130, m135, m140, m145,
m150, m155, m160, m165, m170, m175, m180,
m185, m190, m195, m200, m205, m210, m215,
m220, m225, m230, m235, m240, m245, m250,
m300, m350, m400, m450, m500
Default Value: m200
RlcPdcp UePollR ADD LBFD-0 Radio Meaning: Indicates the length of the Polling PDU
ParaGro trTimer RLCPD 02008/ Bearer retransmission timer for the UE when the
up Preset CPPAR TDLBF Manage RlcParaAdaptSwitch parameter is set to ON and the
AGROU D-00200 ment number of UEs on the network is large. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: m5, m10, m15, m20, m25, m30,
RLCPD m35, m40, m45, m50, m55, m60, m65, m70, m75,
CPPAR m80, m85, m90, m95, m100, m105, m110, m115,
AGROU m120, m125, m130, m135, m140, m145, m150,
P m155, m160, m165, m170, m175, m180, m185,
LST m190, m195, m200, m205, m210, m215, m220,
RLCPD m225, m230, m235, m240, m245, m250, m300,
CPPAR m350, m400, m450, m500
AGROU Unit: ms
P Actual Value Range: m5, m10, m15, m20, m25, m30,
m35, m40, m45, m50, m55, m60, m65, m70, m75,
m80, m85, m90, m95, m100, m105, m110, m115,
m120, m125, m130, m135, m140, m145, m150,
m155, m160, m165, m170, m175, m180, m185,
m190, m195, m200, m205, m210, m215, m220,
m225, m230, m235, m240, m245, m250, m300,
m350, m400, m450, m500
Default Value: m200
RlcPdcp UeStatP ADD LBFD-0 Radio Meaning: Indicates the length of the UE-specific timer
ParaGro rohTime RLCPD 02008/ Bearer for prohibiting status reporting when the
up rPreset CPPAR TDLBF Manage RlcParaAdaptSwitch parameter is set to ON and the
AGROU D-00200 ment number of UEs on the network is large. This
P 8 parameter applies only to LTE FDD and LTE TDD.
MOD GUI Value Range: m0, m5, m10, m15, m20, m25,
RLCPD m30, m35, m40, m45, m50, m55, m60, m65, m70,
CPPAR m75, m80, m85, m90, m95, m100, m105, m110,
AGROU m115, m120, m125, m130, m135, m140, m145,
P m150, m155, m160, m165, m170, m175, m180,
LST m185, m190, m195, m200, m205, m210, m215,
RLCPD m220, m225, m230, m235, m240, m245, m250,
CPPAR m300, m350, m400, m450, m500
AGROU Unit: ms
P Actual Value Range: m0, m5, m10, m15, m20, m25,
m30, m35, m40, m45, m50, m55, m60, m65, m70,
m75, m80, m85, m90, m95, m100, m105, m110,
m115, m120, m125, m130, m135, m140, m145,
m150, m155, m160, m165, m170, m175, m180,
m185, m190, m195, m200, m205, m210, m215,
m220, m225, m230, m235, m240, m245, m250,
m300, m350, m400, m450, m500
Default Value: m200
RlcPdcp Nonspt ADD LBFD-0 Radio Meaning: Indicates whether the eNodeB is compatible
ParaGro UmUeA RLCPD 02008/ Bearer with the UE that does not support the RLC
up daptSwit CPPAR TDLBF Manage transmission in unacknowledged mode (UM) mode.
ch AGROU D-00200 ment An eNodeB configures the RLC transmission mode to
P 8 UM mode of QCI 4, 6, 7, 8, or 9, and a UE that does
MOD not support the RLC transmission in UM mode
RLCPD attempts to set up bearers of QCI 4, 6, 7, 8, or 9. If this
CPPAR switch is turned on, the eNodeB finds the QCI with
AGROU the RLC transmission mode set to acknowledged
P mode (AM) in the sequence of QCIs 9, 8, 6, and 4 and
sets up the bearers in the AM mode of the queried
LST QCI. This parameter applies only to LTE FDD and
RLCPD LTE TDD.
CPPAR
AGROU GUI Value Range: OFF(Off), ON(On)
P Unit: None
Actual Value Range: OFF, ON
Default Value: ON(On)
RlcPdcp Discard ADD LBFD-0 Radio Meaning: Indicates the length of the PDCP discard
ParaGro Timer RLCPD 02008/ Bearer timer. This parameter applies only to LTE FDD and
up CPPAR TDLBF Manage LTE TDD.
AGROU D-00200 ment GUI Value Range: DiscardTimer_50(50),
P 8 VoLTE DiscardTimer_100(100), DiscardTimer_150(150),
MOD LOFD-1 Coverag DiscardTimer_300(300), DiscardTimer_500(500),
RLCPD 20204/ e DiscardTimer_750(750), DiscardTimer_1500(1500),
CPPAR TDLOF Enhance DiscardTimer_Infinity(infinity)
AGROU D-12020 ment Unit: ms
P 3 RRC Actual Value Range: DiscardTimer_50,
LST TDLOF and DiscardTimer_100, DiscardTimer_150,
RLCPD D-12110 DRX DiscardTimer_300, DiscardTimer_500,
CPPAR 5 Policy DiscardTimer_750, DiscardTimer_1500,
AGROU MLOFD for DiscardTimer_Infinity
P -121280 Public
Safety Default Value: DiscardTimer_Infinity(infinity)
/
TDLEO eMTC
FD-121 Introduc
611 tion
RlcPdcp PdcpSn ADD LBFD-0 Radio Meaning: Indicates the length of a PDCP sequence
ParaGro Size RLCPD 02008/ Bearer number of a UL or DL DRB in RLC UM. This
up CPPAR TDLBF Manage parameter applies only to LTE FDD and LTE TDD.
AGROU D-00200 ment GUI Value Range: PdcpSnsize_7bits(7),
P 8 PdcpSnsize_12bits(12)
MOD Unit: bit
RLCPD
CPPAR Actual Value Range: PdcpSnsize_7bits,
AGROU PdcpSnsize_12bits
P Default Value: PdcpSnsize_12bits(12)
LST
RLCPD
CPPAR
AGROU
P
RlcPdcp UlRlcSn ADD LBFD-0 Radio Meaning: Indicates the length of a UL RLC sequence
ParaGro Size RLCPD 02008/ Bearer number in UM. The length is permanently 10 bits in
up CPPAR TDLBF Manage AM. This parameter applies only to LTE FDD and
AGROU D-00200 ment LTE TDD.
P 8 GUI Value Range: RlcSnSize_size5(5),
MOD RlcSnSize_size10(10)
RLCPD Unit: bit
CPPAR
AGROU Actual Value Range: RlcSnSize_size5,
P RlcSnSize_size10
RlcPdcp DlRlcSn ADD LBFD-0 Radio Meaning: Indicates the length of a DL RLC sequence
ParaGro Size RLCPD 02008/ Bearer number in UM. The length is permanently 10 bits in
up CPPAR TDLBF Manage AM. This parameter applies only to LTE FDD and
AGROU D-00200 ment LTE TDD.
P 8 GUI Value Range: RlcSnSize_size5(5),
MOD RlcSnSize_size10(10)
RLCPD Unit: bit
CPPAR
AGROU Actual Value Range: RlcSnSize_size5,
P RlcSnSize_size10
7 Counters
8 Glossary
9 Reference Documents