OpenScape Business X3R/X5R

Getting Started
Quick Reference Guide for the installation and initial startup of the 19-inch rack-mount systems
OpenScape Business X3R/X5R.

OpenScape Business X3R/X5R is a flexible and scalable communication system with high-performance telephony and
a comprehensive unified communications (UC) solution. The UC solution UC Smart is included with the standard
system for up to 50 UC users. For more than 50 UC users, the system can be expanded with the UC solution UC Suite
- via the UC Booster Card (up to 150 UC users) or the UC Booster Server (up to 500 UC users).

1 Further information For wall mounting, the communi- 4 Providing protective


cation system is attached to the wall
For detailed information on the instal- grounding for the system
using two angle brackets.
lation and configuration, please refer To ensure the electrical safety of the
to the documentation • Attach the two mounting brackets
communication system, a separate
(mounting kit L30251-U600-A170) to
• OpenScape Business V1, Installing protective ground connection is
the base of the communication
OpenScape Business X1/X5/X8, required.
system.
Service Documentation • Attach a separate ground wire to the
• Drill a hole for the top bracket, insert
• OpenScape Business V1, Admini- ground terminal at the back of the
a wall anchor into the drilled hole
strator Documentation communication system.
and screw in a screw, leaving
and in the online help of the approx. 2 mm projecting. • Secure the ground wire with a cable
administration program OpenScape tie to the appropriate fastening
• Hang the communication system
Business Assistant (Web Based eyelet for strain relief.
with the upper angle bracket.
Management, WBM). • Connect the ground wire to the
• Drill a hole for the bottom bracket,
The documentation is available on the equipotential bonding system.
insert a wall anchor into the drilled
Internet in PDF format via the Unify
hole and secure the bottom angle
Partner Portal.
bracket with a screw. 5 Setting up the trunk
connection
2 Reading the safety instruc-
For rack mounting, the communi- The public network can be connected
tions via an ITSP (SIP provider via LAN),
cation system is mounted in a 19-inch
Before you put the rack. ISDN (S0 or S2M interface) or an analog
OpenScape Business X3R/X5R into trunk connection (analog interface).
• Attach the two supplied mounting
service, please read and observe the The trunk connection is described in
brackets to the sides of the commu-
safety instructions in the service the service documentation “Installing
nication system.
documentation “Installing OpenScape OpenScape Business X3/X5/X8”.
Business X3/X5/X8”. • Only for X5R: Attach the right and
left support bracket (mounting kit
6 Connecting telephones
3 Mounting the system L30251-U600-A172) to the 19-inch
UP0E and IP system telephones can be
rack.
OpenScape Business X3R/X5R can be connected. The other connection
mounted in a 19-inch rack or on a wall. • Lift the communication system into
the 19-inch rack and attach it to the options for ISDN, DECT and analog
WARNING: 19-inch rack with the two brackets. telephones are described in the service
The housing may only be opened by documentation “Installing OpenScape
an authorized service technician! Business X3/X5/X8”.
IMPORTANT: To provide adequate
system ventilation, make sure that a
minimum clearance of 10 cm is
maintained around the housing!
UP0E system telephones are connected 7 Starting the system 8 Configuring the system
to the UP0E interfaces. • Insert the memory card with the The system is configured using the
If you want to connect more than one system software into the SDHC card wizards of the OpenScape Business
IP system telephone, you will also need slot of the system (if not already Assistant (WBM). For each wizard
a LAN switch. done). page, the associated description is
• Connect all IP system telephones to • Connect the system to the mains available via the “Help” button.
the LAN switch with a LAN cable. power supply. The communication • Connect the admin PC with a LAN
• However, do not connect the LAN system is now started up, The cable directly to the LAN port
switch to the communication system LEDs light up in different marked “LAN”.
system as yet. This is done after the colors and sequences. • The admin PC must be able to obtain
initial Note: The startup takes some time to an IP address automatically. Check
installation. complete. During this time, the the network settings on the admin
Note: When using a LAN switch with communication system can must not PC for this if required.
PoE (Power over Ethernet) function- be turned off. • Open the login page of WBM in the
ality, no separate power supply (e.g., After completion of the startup, the web browser of the admin PC
through a power adapter) is required green LED flashes at 1Hz (0.5 s on / 0.5 (default:
for the connected IP telephones. s off). https://192.168.1.2).
IMPORTANT: The system should not • If the web browser prompts you to
be disconnected from the mains power accept or install a security certif-
supply for at least the next 2 days in icate, please follow these instruc-
order to ensure that the battery is tions.
adequately charged!

Admin PC
(Web browser)
UC Users
(Windows/MAC PC)
IP System Phones

UP0E system telephones


LAN switch

Optional: UC Booster Card

X3R/X5R

8 x UP0E / 4 x analog / 2xS0 LEDs


interfaces
SDHC card slot

Communication system (back)

Connection to
the mains power
supply

Ground wire connection


• Select the language of the WBM user After the licenses have been activated 10 Configuring phones
interface at the top right of the successfully, they must be assigned to
UP0E system telephones are automati-
screen. the stations and trunks.
cally detected and assigned a phone
• Enter the user name (administrator) • Start the “Licensing” wizard in the
number by default.
and password (administrator) and WBM under “Setup > Basic Instal-
click “Login”. lation”. For IP system telephones (HFA), you
will be asked for the call number
• When you log on for the first time, • Enter the License Authorization
(“terminal number” or “fully qual sub
you are prompted to change the Code (LAC) and the user name and
num”) when the phone is booting up.
default password. Enter the default password to log into the license
The standard call numbers are three
password and your new password, server.
digits. Enter the number 120 for the
and then click “Login”. Make sure • Click “OK & Next”. The connection first IP system telephone, for example,
that you remember your new to the license server is established, the number 121 for the second IP
password. and the licenses are released. telephone, and so on.
• Enter the date and time, and the • Click in the navigation bar on If the IP system telephone was already
click “OK & Next”. “License Management”, then on connected to another communication
• Log into the WBM again with your “Local User Licenses” in the system, you will need to first perform a
new password. navigation tree, and navigate to the factory reset.
• Start the “Initial Installation” wizard desired subscriber type (“TDM User”
• To do this, press the 2, 8 and 9 keys
in the WBM under “Setup > Basic includes the UP0E system
simultaneously on the IP system
Installation”. This wizard guides you telephones; “IP User” includes the telephone and
through the system settings and the HFA and SIP IP system telephones). confirm the prompt about the
basic configuration. The preset • Activate the user licenses (first factory reset.
values must only be changed if the column with check boxes) for the • Enter the Reset password (124816)
system is to be integrated in an required stations and then the and confirm it.
existing infrastructure. desired UC licenses.
Note: The configuration of SIP system
• Exit the WBM. • Click “OK & Next”. A check is now telephones is described in the Admin-
• Remove the LAN cable of the admin performed to determine if enough istrator Documentation under “Initial
PC from the LAN port marked “LAN” licenses are available for your Installation of OpenScape Business X”.
and connect it to the LAN switch. assignments. If licenses are missing,
• Connect the LAN port marked “LAN” the errors are displayed with a check 11 Activating UC Smart
of the communication system to the box shaded in red. Correct these
errors and click again on “OK & This configuration is only required if
LAN switch using a LAN cable. you want to use the UC solution UC
Next”.
• If a UC Booster Card is inserted, Smart.
connect the LAN port marked • In the navigation tree, click on “CO
Trunks”. UC Smart must be enabled, and you
“LAN2” of the UC Booster Card (at must assign a uniform initial password
right of the two LEDs) to the LAN • For SIP trunks, enter the number of
for all users of UC Smart.
switch using another LAN cable. Internet calls that can be conducted
simultaneously via an ITSP in the • Start the “UC Smart” wizard in the
• Restart the WBM and run the “Basic WBM under “Setup > UC Smart”.
Installation” wizard under “Setup > “License demand for number of
Basic Installation”. Here you can simultaneous Internet calls in this • Under “Basic Settings”, select the
configure, among other things: Your node” area. “Active” check box.
trunk connection, Internet access • For S2M trunks or T1 trunks (only for • Click under “System-wide initial UC
and the connected telephones the U.S.), select the number of Smart password” on “Configure”,
(subscribers). desired B-channels in the drop- enter the initial password and
down list of the Demands column in confirm it with “Set”.
9 Licensing the row of the desired slot in the IMPORTANT: Communicate the initial
“S2M” or “T1” area. password to all UC Smart users! This
You must activate your purchased
licenses within 30 days (activation • Exit with “OK & Next”. initial password be changed by the
period). user when logging in at a UC Smart
client for the first time. Without the
IMPORTANT:
assignment of an initial password, the
OpenScape Business X3R/X5R is fully
user cannot log into to a UC Smart
functional during the activation
client.
period. If the licensing is not
completed before the activation period
expires, the system will subsequently
operate only in the restricted
emergency mode!
12 Installing the UC clients The following applies when logging in
to the UC client for the first time:
The software of the UC clients is
provided via the WBM. Depending on • The user name corresponds to the
the selected UC solution, different UC station number of the user.
clients are offered. • For UC Suite clients:
• Click in the WBM on “Service Center The default password is 123456.
> Download Center” or “Service • For UC Smart clients:
Center > Applications”. The default password is the previ-
• Click on the software link of the ously assigned initial password.
desired UC client and download the • The server IP address is 192.168.1.2
software (e.g., “myPortal smart” for by default.
UC smart and “Communication- • The protocol is https.
sClients” for UC Suite).
• For UC Suite clients: 13 Updating
Unpack the ZIP file on the client PC
If a more recent version of the software
and run the installation file. Follow
is available, this is shown on the home
the installation instructions.
page of the WBM as soon as
• For UC Smart clients: OpenScape Business X3R/X5R is
Start the file connected to Internet. You can then
“SmartClient.air” on the client PC start the update via the “Service
and follow the installation instruc- Center” menu.
tions.
IMPORTANT: To install the UC clients,
you must have local administration
rights! For the UC Suite clients, the
latest version of Java must be
additionally installed. Adobe Air (link
in the Service Center) must be
additionally installed for the UC Smart
client myPortal Smart.
For mobile UC users with iOS or
Android smartphones, there is also the
mobile app “myPortal to go”, which can
be downloaded from the Apple App
Store or the Google Play Store.

Copyright © Unify GmbH & Co. KG 07/2014


Hofmannstr. 51, 81379 Munich/Germany
All rights reserved.
Reference No.: A31003-P3010-G101-1-7631
The information provided in this document contains merely general descriptions or
characteristics of performance which in case of actual use do not always apply as
described or which may change as a result of further development of the products. An
obligation to provide the respective characteristics shall only exist if expressly agreed
in the terms of contract.
Availability and technical specifications are subject to change without notice.
Unify, OpenScape, OpenStage and HiPath are registered trademarks of
Unify GmbH & Co. KG. All other company, brand, product and service names are trade-
marks or registered trademarks of their respective holders.

unify.com

S-ar putea să vă placă și