Contents
7 NEMA, Special Purpose and Mining Rating
Description Page
7 NEMA, Special Purpose and Mining Rating
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V5-T7-3
7 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T7-4
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . V5-T7-6
7 Technical Data and Specifications . . . . . . . . . . V5-T7-7
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . V5-T7-9
7 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T7-10
7
7
7
7
7
7 Product Description Application Description Operation Features
7 Vacuum contactors and
starters were designed for
The vacuum contactors and
starters are offered in three
The contact structure of the
vacuum break contactor is
● Rugged, compact and
lightweight
starting and controlling three- classifications. They are located inside sealed ceramic
7 Quiet operation
●
phase, 50/60 Hz, AC motors. NEMA rated devices up to tubes that have been ● Electrical and mechanical
Each contact is enclosed in a 600 Vac, Special Purpose evacuated of air. Any arc
7 vacuum bottle to reduce and rated devices up to 1500 Vac occurring across the contacts
●
interlocks available
Long service life
contain contact arcing. This and Mining rated devices upon opening is automatically
7 design offers excellent rated up to 1500 Vac. Each extinguished because ionized
performance for plugging and device is tested to different air is not available to sustain Benefits
7 jogging applications. standards to serve its market. it—the arc breaks when the
current passes through zero.
● Easy maintenance with
Typical applications include front removable coil and
The arc typically does not
7 full voltage control of three-
phase squirrel cage motors,
service beyond the first half
auxiliaries
cycle once the contacts begin
● Eliminate extra surge
7 primary control of low voltage
wound rotor motors and
to separate. The large arc suppressors with the
standard low chop
chutes normally associated
circuit switching for low interrupters
7 voltage capacitors for power
with contactors of this size
are not required. The ceramic ● Plan your preventative
factor improvement. maintenance schedule by
7 A vacuum contactor is
tube with the moving and
stationary contacts is called a utilizing the contact wear
vacuum interrupter or indicator, standard on all
7 affected by atmospheric
pressure on the bellows of bottle. There is one bottle for vacuum bottles
the vacuum bottles. Up to an each pole on the contactor.
7 altitude of 6600 feet, the A metal bellows (like a small, Standards and
contactor is designed to circular accordion) within the
Certifications
7 tolerate normal variations in
barometric pressure. If the
bottle allows the moving
contact to be closed and ● NEMA Devices
pulled open from the outside
7 UL Listed File #E1491,
●
contactor is to be operated
above 6600 feet above sea without leaking air into the Guide Number NLDX
level, consult your Eaton bottle. Both the bellow and CSA Approved
7
●
7
7
7
575 300
800 450 440/480 V201KTCUZ1 V211KTCUZ1 V200MTCU V210MTCU
1000 500
1500 900
7
540 200 150 110/120 V201KVCJZ1 V211KVCJZ1 V200MVCJ V210MVCJ
230
380
200
300 220/240 V201KVCKZ1 V211KVCKZ1 V200MVCK V210MVCK 7
460 400 380/415 V201KVCHZ1 — V200MVCH —
575
1000
500
1000 440/480 V201KVCUZ1 — V200MVCU — 7
1500 1250
610 200 200 110/120 V201KZCJZ1 V211KZCJZ1 — —
7
230 200
380
460
300
450
220/240
380/415
V201KZCKZ1
V201KZCHZ1
V211KZCKZ1
—
—
—
—
—
7
7
575 500
800 800 440/480 V201KZCUZ1 — — —
1000 1000
1500 1600
7
Notes
1 Coils are rated for 50/60 Hz applications.
2 Starters use Type B overload relay. Refer to Heater Coil Selection table on Page V5-T7-6. Starters do not include heater packs.
7
7
7