Documente Academic
Documente Profesional
Documente Cultură
www.kentrox.com
DataSMART 658 T1 Add/Drop DSU/CSU
Web
Server
V.35 serial
interface
(Nx56/64k)
T1 to carrier or
corporate office
DataSMART
658
T1
The DataSMART 658 quickly and easily provides managed connectivity for data or other high-speed serial applications.
1 2 3 4
SPECIFICATIONS
Network Interface Data Port Interface
Line Rate Internal or external clock; Bit Rates 56 kHz to 1536 kHz
1.544 Mb/s ± 50 bps Mechanical 34-pin MRAC34 Socket connector
Line Code AMI or B8ZS (selectable) Electrical Interface V.35 compatible
Line Impedance 100 ohms ± 10 ohms at 772 kHz Interface Type DCE
100 ohms ± 20% over the frequency band 100
kHz to 1MHz Management
Lightning Protection Withstands lightning surges defined per FCC Part Control Ports DE9 Plug (DTE); DE9S Socket (DCE)
68, and recovers Ethernet 10-Base-T RJ-45
Framing Format SF or ESF per ANSI T1.403-1995, and TR-54016- Baud Rates 2400, 9600, 19200, 38400
1989; Ericcson Framing (defined as valid F T bits SNMP Agent MIB II (RFC 1213), DS1 MIB (RFC 1406), Enterprise
only) MIB (available at www.kentrox.com). Telnet
Input Level DSX-1 to -27.5 dB Server; responds to PING; security filter for IP
Input Jitter Tolerance Per TR 62411-1990 (p.4.7.1) source addresses; up to 10 SNMP trap hosts
Output Level Per ANSI T1.403-1995 In-band FDL or dedicated DS0
3.0 Volt peak ± 10% into 100 ohms at output
connector EMC and Safety
Input Signal Tolerant to impedance mismatches Terminal 47 CFR 68, CS.03
Line Build Out 0, 7.5, 15.0 selectable Emissions 47 CFR 15, Class A
Output Jitter TR 62411-1990 (p.4.7.3) Safety CSA 60950-1-03/UL 60950-1
Pulse Density (When enabled) shall be > 12.5%
Mechanical DA15 Plug Environment
Operating 0° to 50° C (5% to 90% RH,
Terminal Interface non-condensing
Line Rate Internal: 1.544 Mb/s ± 50 bps Storage -20° C to 66° C (5% to 65% RH)
When timing is derived from input signal: 1.544 AC Input Range 85 to 130 VAC, 47 to 63 Hz
Mb/s ± 200 bps; Outline rate follows input line Power Interruptions Loss of power does not damage the unit. Loss of
rate power for less than 5 years does not change the
Line Code AMI or B8ZS (selectable) configuration settings which may have been set
Line Impedance 100 ohms ± 10 ohms at 772 kHz by the user. Loss of power for less than 2 hours
(nominal) does not affect the real-time clock
100 ohms ± 20% over the frequency band 100
setting.
kHz to 1MHz
Framing Format SF or ESF per ANSI T1.403-1995, and TR-54016-
Power
1989; Ericcson Framing (defined as valid F T bits
AC 115 VAC, 60 Hz, 7W
only)
Idle ESF Data Link is set to all ones
Physical
Input Level DSX-1 to -10.0 dB
Usage Desktop or tray mount
Input Jitter Tolerance Per TR 62411-1990 (p.4.7.1)
Dimensions 7.75" W x 1.65" H x 11.5" D
Input Jitter Transfer Per TR 62411-1990 (p.4.7.2)
Weight 2.5 lbs (approx.)
Output Level DSX-1 at connector (no equalization enabled)
Equalization Up to 655 feet selectable, 5 steps
Warranty
Mechanical DA15 Socket
Hardware 5 years
Kentrox, LLC
20010 NW Tanasbourne Dr.
Hillsboro, OR 97124
Phone 503-643-1681
Service and Support 800-733-5511
www.kentrox.com