DataSMART® MAX™ T1/FT1 multi-port DSU/CSUs
from Kentrox help you consolidate traffic at remote • Voice, data and video multiplexing
sites, and save access charges month after month. • Standards-based SNMP
By leveraging unused bandwidth and merging management
voice, data and video traffic onto a single T1 link, • Optional Ethernet connection for
you can reduce the number of T1/FT1 lines needed SNMP and Telnet management
for WAN access. • Front-panel LCD and LEDs for
simple setup and troubleshooting
DataSMART MAX DSU/CSUs maximize your
• Software-selectable data ports for
network uptime with convenient features, such
flexibility (V.35 and EIA-530)
as optional 10Base-T Ethernet for simplified
management. Each DSU/CSU includes a front- • Free DataSMART Installer for
Windows and Alarms Utility
panel LCD for easy local setup and management,
software
along with support for standards-based SNMP
management. • Compatible with all major routers,
video codecs, voice PBX and other
customer premise equipment
• Supports leased-line, Internet,
Frame Relay and frame-based
SMDS/ATM DXI network services
• 5-year manufacturer’s warranty
DataSMART® MAX™

Carrier Network
Easy installation and diagnostics DataSMART MAX
V.35
Dual-Port Add/Drop
Shipped free with every unit, DataSMART EIA-530 T1
Frame
DCS Relay
Installer is an intuitive, Windows-based
Router
configuration and diagnostic utility. T1 V.35
Point
DataSMART Installer dramatically reduces to
Point PSTN
setup time, by walking the user through P
B Video
the process using a series of Windows- X

based templates. For easy local installation


and troubleshooting, the DataSMART MAX
also provides a front-panel LCD and The DataSMART MAX add/drop DSU/CSU supports voice over
diagnostic LEDs. the public switched telephone network (PSTN), Frame Relay
data traffic, and point-to-point applications.

Performance monitoring and alarms


To help you resolve performance problems
on your circuit, DataSMART MAX DSU/CSUs
provide comprehensive T1 diagnostic tools.
You can diagnose degradation of your T1/FT1
circuit, and resolve it with your carrier before
it affects service. With the DataSMART MAX, Remote Office
Corporate
you can also download software upgrades, Ethernet
DataSMART MAX
Dual-Port
Headquarters
Management
receive traps for important network events, T1 T1
and receive remote alarms. Network LAN
V.35
EIA-530 V.35
Network
Management
Video
Standards-based management
For your management requirements, the
DataSMART MAX includes an embedded
With its optional Ethernet connection, the DataSMART MAX can
SNMP agent. The agent supports SETs, GETs be remotely managed in-band from the corporate office.
and Traps, as well as the standard MIBs, such
as MIB II and the T1 MIB. For comprehensive
control, an enterprise MIB supports all
available functions. In addition, a Telnet
server is included, allowing direct access to
the DataSMART MAX menus through the
network. Remote access to the unit is
available through RS232 control ports or
an optional 10Base-T connection. V.35
DataSMART MAX
Quad-Port Add/Drop
EIA-530 T1
WAN

Alarms Utility Router

P T1 V.35 V.35
B Video
The Alarms Utility software monitors the X
network for interface and device errors, SNA Controller
posting them to the event log in HP
OpenView®. Custom icons uniquely identify The DataSMART MAX quad-port add/drop DSU/CSU has
all Kentrox devices for easy recognition on enough ports to handle more complicated voice, video and
the Network Node Manager topology map. data integration applications.

www.kentrox.com 2
800.733.5511
DataSMART® MAX™

Specifications
NETWORK INTERFACE DIAGNOSTICS
Line Rate: T1 (1.544 Mbps) LEDs: Network interface status, terminal
Framing: SF, ESF, Ericsson interface status, data port status, power/fail,
Line Code: AMI, B8ZS test active
Input Signal: DS-1 from 0 dB to -27 dB, typical LCD: Front panel for configuring, testing, and
Output Signal: DS-1 with LBO 0, -7.5, display of unit status
-15 dB (selectable) Loop Tests: Line loopback, payload loopback,
Mechanical: DA15 plug local loopback, terminal loopback, data
Lightning Protection: Withstands lightning surges defined terminal loopback, data port loopback
per FCC Part 68, and recovers Line Test Codes: QRS, 3-in-24, 1-in-8, All 1s,
TERMINAL INTERFACE (ADD/DROP PORT) All 0s
Line Rate: T1 (1.544 Mbps) Data Test Codes: 511, 2047
Framing: SF, ESF, Ericsson BERT Tester: Independent BERT on all test codes
Line Code: AMI, B8ZS Monitor Jacks: Network interface, transmit and
Input Signal: DSX-1 to -10 dB receive
Output Signal: DSX-1 with equalization PERFORMANCE MONITORING
Mechanical: DA15 socket Data Storage: Last 24 hours of data in 15 minute
DATA PORT INTERFACE (SELECTABLE) increments; last 7 days of data in 24-hour
Bit Rate: Nx56 kbps or Nx64 kbps (N=1...24) increments
Electrical: V.35 compatible, DB25 socket or Monitors: Network and terminal interface
EIA-530/RS449, DB25 socket Registers Reports: Separate for carrier and user
Based on G.821 for performance
MANAGEMENT
Far end, alarm history, and network interface
Control Ports: DCE and DTE
statistical reports
EIA-574
DE9 socket and plug COMPATIBILITY
Daisy chain AT&T: TR 54016-1989, TR 62411-1990,
38.4 kbps maximum TR 54019A
English menus PUB 43802
Async ASCII or SLIP ANSI: T1.403-1995
Ethernet Connection: Optional 10Base-T PCMCIA adapter Bellcore: TR.194
SNMP Agent: MIB II (RFC 1213) REGULATORY
DS1 MIB (RFC 1406) FCC Compliance: Part 68; Part 15, Class A
Enterprise MIB NRTL Listed: UL 1950, 3rd Edition
TELNET server CSA: 22.2; No. 950
Responds to PING IC: CS-03
Security filters (for IP source addresses) ENVIRONMENT
Up to 10 SNMP Trap hosts Operating: 0° to 50° C
In-band: Via external router 5% to 90% RH, non-condensing
In-band Menus: Via external router Storage: -20° to 66° C, 5% to 95% RH
ALARMS POWER
Traps: SNMP Traps via SLIP or via Ethernet AC: 110 to 240 VAC, 50 or 60 Hz, 18W
ASCII: Transmitted out async control port DC: 24 to 48 VDC, 14W, dual power inputs
PHYSICAL
Usage: Desktop or rack mount (19” or 23”)
Dimensions: 17.5” W x 1.72” H x 11.5” D
Weight: 7 lbs. (approximate)

Ordering Information

Description Catalog Number


DataSMART T1 MAX Dual-port, AC 72561
DataSMART T1 MAX Dual-port, Add/Drop, AC 72761
DataSMART T1 MAX Dual-port, Add/Drop, DC 72765
DataSMART T1 MAX Quad-port, Add/Drop, AC 72771
DataSMART T1 MAX Quad-port, Add/Drop, DC 72775
Optional 10Base-T PCMCIA Adapter 98101

www.kentrox.com 3
800.733.5511
DataSMART® MAX™
DataSMART T1 MAX Dual-port DSU/CSU

1 2 4 5 6

DataSMART T1 MAX Dual-port, Add/Drop DSU/CSU DataSMART T1 MAX Quad-port, Add/Drop DSU/CSU

1 2 3 4 5 6 1 2 3 4 5 6

Ordering Information

Description Catalog Number

1 NETWORK INTERFACE
DA15S to DA15P 930xx091
DA15S to RJ48C Plug 930xx151
DA15S to Stub 930xx111
DA15S to RJ48C Jack Adapter 77891
DA15S to Barrier Strip Adapter 77993004
2 AUXILIARY PORT
3 TO TERMINAL EQUIPMENT
DA15P to Stub 930xx101
DA15P to DA15S 930xx091
DA15P to RJ48C Plug 930xx121
DA15P to DA15P 930xx131
DA15P to DA15P, Crossover 93005132
DA15P to RJ48C Jack Adapter 77892
DA15P Plug to Barrier Strip Adapter 77993003
4 CONTROL PORT (DCE/DTE)
DE9S to DE9P, 6 feet 95006022
DE9S to RJ45 Socket Adapter 78899
DE9S to DB25P 95005023
DataSMART Installation Kit 78891
5 10BASE-T LAN
Optional PCMCIA Card, 10Base-T 98101
6 TO DTE EQUIPMENT
V.35
DB25P to MRAC34P, 10 feet 95010054
DB25P to MRAC34P, (DCE to DCE) 95010073
DB25P to MRAC34S 95001074
DB25P to MRAC34S (Wellfleet Adapter) 78906001
EIA-530
DB25P to DB25P, 10 feet 95010061
DB25P to DB25P, (DCE to DCE) 95010058
DC25P to DB37P (EIA-530 to RS449) 95010066
DC25P to DB37S (EIA-530 to RS449) 950xx042

Note: xx denotes length of cable. Contact factory for available lengths. DA, DB, DC, DE designate the size
of the shell that encapsulates the cable connector. P=Plug (male); S=Socket (female).

Web Site: www.kentrox.com


Phone: 503-643-1681 • Toll Free: 800-733-5511 • Fax: 503-350-6897
Kentrox, LLC., 20010 NW Tanasbourne Drive, Hillsboro, OR 97124
Kentrox, AAC-3, CellSMART and DataSMART are registered trademarks of Kentrox, LLC. AAC, AAC-2, FrameVision, ServicePoint and
ServicePoint Manager are trademarks of Kentrox, LLC. All other products are trademarks of their respective owners. Specifications
published here are current as of the date of publication of this document. At any time, you may verify product specifications by
contacting our headquarters in Hillsboro.

05-04-014 12/02 Copyright © 2002-2003 by Kentrox, LLC. All Rights Reserved. An Equal Opportunity Employer.

S-ar putea să vă placă și