Sunteți pe pagina 1din 4

3. Pornirea dispozitivului 4.

Acces camera:
si configurare IP:
4.1 Acces prin Internet Explorer
3.1 Pornirea dispozitivului Deschideti Internet Explorer, introduceti
NOTA: Folositi doar un alimentator de adresa IP in bara de adresa a browser-
12 V 2A sau similar. Dupa alimentarea la ului sub forma: http://192.168.1.10
Ghid rapid de utilizare curent si la reteaua de internet, asteptati Introduceti nume utilizator si parola.
50 de secunde inainte de a folosi Valorile implicite sunt:
Camera supraveghere video
camera. - utilizator: admin
PNI IP12MP 1 Afisare canal 5 Meniu principal
- parola: necompletat 2 Previzualizare 6 Control PTZ
3.2 Configurare IP Va recomandam sa schimbati parola de
[Adresa IP]: implicit 192.168.1.10 3 Divizare ecran 7 Istoric evenimente
administrare imediat dupa prima logare 4 Volum
[Subnet Mask]: implicit 255.255.255.0 in sistem.
[Default Gateway]: implicit 192.168.1.1 Dupa autentificare, accesati [Stream Accesati [Main menu] ->[System] -
menu] pentru a seta fluxul video >[Device Manager] pentru a adauga o
Deschideti CD-ul din pachet si instalati principal si secundar.
software-ul General Device Manager . camera.
Nota: Manualul complet de utilizare al
Apoi click pe [IP search]. Pe ecran vor fi software-ului CMS il gasiti pe CD-ul
afisate toate adresei IP online ale inclus in pachet.
dispozitivelor de monitorizare din retea.

1 Meniu principal 3 Meniu control PTZ


1. 3. 5. 7.

1. Introducere: 2 Stream selection 4 Meniu scurtaturi 4.3 Accesare prin dispozitive mobile
NOTA: Pentru accesare via Internet Retea compatibila: WiFi
Acest manual este doar un ghid rapid de
Explorer trebuie sa instalati plug-in-ul Sistem de operare: Android, iOS
utilizare pentru camerele cu IP PNI.
ActiveX. Aplicatie: XMEye
Pentru informatii mai detaliate, va
rugam sa consultati CD-ul inclus in Setati nivelul de securitate al browser-
ului: Nota: Manualele de utilizare ale
pachet.
[Internet options] -> [Security] -> aplicatiilor le gasiti pe CD-ul inclus in
[Custom level] -> [ActiveX] (click Enable pachet.
2. Descriere produs: la toate optiunile).
Pentru instalarea plug-in-ului, accesati
1 Alegeti o adresa IP http://xmeye.net sau instalati-l de pe
Carcasa metalica
rezistenta la apa Adresa IP selectata si alti parametri sunt CD-ul inclus in pachet [Software]-
LED-uri IR afisati in partea dreapta a ecranului. >[IEActive]->IE plug-in_V1.1.0.78.exe.
Daca aduceti modificari parametrilor de Xmeye
configurare, click pe butonul “Modify” 4.2 Acces software CMS
pentru a salva. De pe CD-ul inclus in pachet, instalati
Alimentare 12V NOTA: Camera video trebuie sa fie in software-ul de management (General
aceeasi retea cu router-ul. Faceti click CMS):
Interfata retea
pe butonul “Same to PC” pentru a b. Dublu click pe iconita CMS,
importa toti parametri de retea ai PC- introduceti nume utilizator si parola.
ului (Subnet Mask si Gateway). Valori implicite:
- Utilizator: super
- Parola: necompletat
2. 4. 6. 8.
4.4 Acces prin Cloud 5. Intrebari si raspunsuri:
a. Accesati pagina http://xmeye.net. 5.1 Instalare ActiveX IE 5.5 Sunteti autentificat in serviciul de
Autentificati-va: Instalare ActiveX IE in Windows 7 Cloud, dar nu puteti previzualiza
- Reduceti nivelul de securitate al camera.
computerului. In meniul principal rulati Cauza: ActiveX nu este instalat. Instalati
comanda “msconfig”, schimbati setarile plug-in-ul ActiveX conform indicatiilor
UAC, click “Enable”, selectati “Never din acest manual (punctul 7.1).
notify”.
- Setati nivelul de securitate IE
Accesati Control Panel>Network and
Internet>Network and Sharing
Center>Internet Options. Selectati
nivelul de securitate. Activati Toate
b. Adaugati camera video urmand optiunile ActiveX.
indicatiile
Instalare ActiveX IE in Windows XP
- In sistemele de operare XP este
necesara doar setarea nivelului de
securitate (respectati pasii descrisi la
Windows 7)

9. 11. 13. 15.

c. Click Login pentru a accesa interfata 5.2 Mutarea obiectelor in cadru 6. Specificatii tehnice:
Cloud. Faceti click in partea stanga a genereaza o umbra in afisarea pe
ecranului pe o camera pentru ź Senzor CMOS
ecran.
previzualizare. ź Filtru IR-CUT
Cauza: dupa activarea obturatorului
ź Rezolutie 720P
electronic, rata de frame-uri este prea
ź Sitem video PAL
mica.
ź Compresie video H.264
Accesati [Device config]->[System
ź Lentile fixe 3.6mm
settings]->[Camera parameters] si
ź LED-uri IR 24 bucati
dezactivati “Electronic shutter”.
ź Distanta iluminare IR: 20 m
ź Suporta monitorizare de pe
5.3 Actualizare nereusita
d. Dupa ce ati configurat in mod corect Cauza: Firmware-ul este incompatibil dispozitive mobile: iPhone, iPad,
camera, o puteti accesa de oriunde atat cu modelul camerei video. Contactati Android
timp cat aveti acces la internet. distribuitorul dumneavoastra pentru a ź Compatibil cu protocolul ONVIF 2.3
NOTA: Semnul rosu din partea stanga a obtine o versiune de firmware ź Port Ethernet 10 / 100 Mbps
ecranului de previzualizare indica faptul compatibila. ź Suporta functia iCloud (P2P)
ca respectiva camera video nu este ź Compatibil cu: Internet Explorer
conectata la serviciul cloud. 5.4 Eroare conectare Cloud ź Inregistrare imagini la distanta pe
- Accesati [Device config]->[System PC sau NVR
settings]->[Network settings] pentru ź Temperatura de functionare
configurare DNS -20°C ~ +40°C
- Inchideti in router filtrul adresei MAC si ź Umiditate <95%
IP si toate limitarile accesului la reteaua
publica.
10. 12. 14. 16.
3. Boot up & IP configuration: 4. Camera access:
4.1 IE Access
3.1 Boot up Open web browser, enter IP address,
Please use a 12 V 2A power adapter or take 192.168.1.1 O as an example,
similar. input http: //192.168.1.10 to connect.
Quick guide Please use the positive power of about Enter user name and password
50 seconds of network cameras start (default user name is admin, no
Video surveillance camera
complete, the network camera through password). Change the administrator
PNI IP12MP
a cable connected to the LAN. password timely after login. 1 Channel display 5 Main menu
After successful login, go to [stream 2 Preview 6 PTZ control
3.2 IP config menu] to connect main stream or
[IP address]:default is 192.168.1.10 3 Screen-split 7 Log display
substream. 4 Volume
[Subnet Mask]:default is 255.255.255.0
[Gateway]:default is 192.168.1.1.
3.Go to [Main Menu] > [System] >
Open the CD and install the software [Device Manager] to add camera.
General Device Manager.
Note: The CMS detailed user manual
Then click [IP search], all online IP can be found on the CD included in the
addresses of the monitoring devices package.
within the LAN will be searched and
displayed.

1 Main menu 3 PTZ control


1. 3. 5. 7.

1. Introduction: 2 Stream selection 4 Shortcut menu 4.3 Mobile Access


Note: Plug-ins need to be installed if you Network environment: WIFI
This operation manual is only for a brief
login via IE browser. IE is default to Mobile system: Android, iOS
description of the product, for more
intercept plug-in. App name: XMEye
product information please open the
CDROM. Please set IE security level. Go to
<internet options>--<security>--< Note: The detailed user manual of the
Customized level>-<ActiveX >, enable mobile applications can be found on the
them all. Or go to our official website to CD included in the package.
2. Product description: download and install plug-ins
1 Choose one IP address
(http:flwww.xmeye.net); Or get it from
Choose IP address to config. IP address the CD and install IE plug-in
Waterproof
metalic case and port are displayed on the right, you _V1.1.0.78.exe.
IR LEDs can modify the IP parameters and click
"Modify" to save. 4.2 CMS access Xmeye
Note: IP address of the speed dome 1. Open the CD, double-click Setup.exe,
must share the same network segment go to [English] > [Software]> [CMS] to
DC 12V input with the router and conform to the install centralized network video
router's IP, and make sure the IP is not management software.CMS shortcut
Network interface
conflicted in the network of LAN. Go icon will be displayed when installed
to[conform to local PC] to automatically successfully.
match subnet mask and default 2. Double-click CMS shortcut icon, input
gateway with local computer. user name and password( user name:
super, no password) to login.
2. 4. 6. 8.
4.4 Cloud access 5. Q&A: 5.5 Cloud server login, but can not
a. Visit http://xmeye.net. get live videos
5.1 IE ActiveX installation
Login: IEActiveX is not installed, so follow
IE ActiveX installation in WIN7
instruction to install ActiveX, please
- Lower PC security level: In the main
close anti-virus software before
menu, run"msconfig", change UAC
installing it, otherwise it will intercept the
settings, click "enable" , select "Never
installations of IE ActiveX or make the
notify."
installation uncompleted.
- Set IE security level
Note: Only common questions and
Go to Control Panel> Network and
solutions are mentioned above, for
Internet>Network and Sharing Center>
more information, please contact us
Internet Options, select the Custom
directly.
Level; enable all the ActiveX controls
b. Install it step by step according to the and plug-ins.
guides prompt message. IE ActiveX installation in XP
In XP system, only need to set IE
security level, operation same as Win7.

5.2 Moving object has dragged


shadow in the live screen
It's caused
It's caused by insufficient frame rate
after enable electronic shutter. In dark

9. 11. 13. 15.

c. Click "Login" to enter cloud service environment, our speed dome camera 6. Technical specifications:
interface, double-click left camera with will open the electronic shutter
alias name to connect to the preview. ź Sensor: CMOS
automatically to get good image, it will
ź IR-CUT filter
come out dragged shadow as lengthen
ź Resolution 720P
exposure time and lower stream, and
ź Video system PAL
you can go to <device config>-<system
ź Fixed 3.6mm Lens
settings>-<camera parameters> to
ź 34 IR LEDs
close •electronic shutter-
ź 20m illumination
ź Supports: iPhone, iPad, Android
5.3 Upgrade failed
ź Supports ONVIF 2.3 protocol
Upgrade firmware doesn't match
d. After successful configuration, ź Port Ethernet 10 / 100 Mbps
product model, please contact us to get
wherever and whenever you are, as ź Supports iCloud (P2P) function
the correct one.
long as you can surf the Internet, you ź Supports Internet Explorer Browser
5.4 Connect cloud service failed
can get access to the device. ź Remote recording on PC or NVR
Go to [Device Config]> [System
NOTE: When left device name shows ź Working temperature
Settings]> [Network Settings] to config
with red cross, it means speed dome is -20°C ~ +40°C
DNS, make sure it shares with LAN
not connected with cloud service ź Working humidity <95%
router.
website. 2. Turn off the router's MAC address
filtering, IP address filtering and other
limit connections to public network.

10. 12. 14. 16.

S-ar putea să vă placă și