STRUCTURAL DESIGN CRITERIA

LOADINGS
1. DEAD LOAD
 Concrete - 24 kN/cu.m
 Structural Steel - 27 kN/cu.m
 25 mm concrete topping - 0.60 kPa
 Floor Finish - 0.50 kPa
 Ceiling - 0.15 kPa
 Utilities (Water, Electrical & Mechanical) - 0.24 kPa
 150 mm CHB exterior wall - 2.40 kPa
 100 mm CHB interior wall - 1.76 kPa
 Gypsum board wall on metal frames - 0.38 kPa

2. DEAD LOAD
 Commercial - 1.9 kPa
 Stairways - 2.4 kPa

3. WIND LOAD – Applicable for provision Zone 2

4. SEISMIC LOAD – Applicable for provision Zone 4

5. LOAD COMBINATIONS

 D+L
 1.4D
 1.2D + 1.6L +0.5(Lr or R)
 1.2D + 1.0W 0.5L(Lr or R)
 1.2D + 1.0E + 0.5L
 0.9D + 1.0E
OCCUPANCY CATEGORY
IV – Standard Occupancy Structure
STORY DRIFT LIMITATION
In accordance with the 208.6.5(for 5 storey) provision of NSCP PLEASE READ!!!
FOUNDATION
Soil bearing capacity of 144 kPa shall be used for gravity loading based on the provided
geotechnical report by ABC Geotek, Inc.

MATERIAL PROPERTIES
1. Concrete Compressive Strength in 28 days, fc' =27 Mpa
2. Structural Steel Yield Strength, fy = 248 Mpa
3. Reinforcing Bar Yield Strength: for 12mm dia. and below, fy = 275 Mpa
for above 12mm dia., fy = 414 Mpa

APPLICABLE CODES / REFERENCES


1. National Structural Code of the Philippines, Volume I – 7th Edition
2. National Building Code of the Philippines, Latest Edition
3. American Concrete Institute, ACI 318-14M, Building Code requirements for Reinforce Concrete
4. ASEP Steel Manual, 1st Edition