Separate tanks are used to store oil which is used for different valves on the ship. Valves such as ballast valves, fuel
valves etc. are remotely operated by hydraulic oil.
W
WEEKKAA M
Maaggnneettiicc LLeevveell IInnddiiccaattoorrss
WEKA Magnetic Level
Indicators
Barthel Armaturen
Competent , fast and �exibel. Your
manufacturer under licence!
barthel-armaturen.de
OPEN
Tanks for hydraulic oil are located outside the engine room to store winches oil.
Steering gear hydraulic oil tank is normally located in the steering room and is used as a storage tank to receive bulk oil.
Water tanks
OPEN
Fresh water tanks present onboard may be two or more in numbers, depending upon the size of vessel. They are used
to store sanitary water for accommodation, engine room and deck use.
A separate drinking water tank may be present to store drinkable water received from shore or to store water produced
by fresh water generator (F.W.G).
A ship’s boiler needs distilled water to produce steam, and therefore water from fresh water generator (F.W.G) is stored
in distilled water tank.
The boiler feed water system consist of a separate tank which receives water from distilled water tank.
Cascade tank
Cascade tank, also known as hot well, is a part of boiler feed water system. Water is pumped into the cascade tank
from the feed water tank. The boiler water is treated in the cascade tank and the return from the steam heating system
is also connected to the hot well.
Ballast water tanks
Ballast water tanks are present all over the ship for ballasting and de-ballasting purpose for stabilizing the ship and for
acquiring correct draught for port and canal crossing etc. Double bottom tanks are generally located outside the engine
room.
This tank is located around the stern tube of the propeller and acts as a cooling media for the same. It can be used as a
fresh water water tank of the ship.
Slop tanks
Slop tanks are present onboard tanker to store oily water mixture from cargo tank washing. The number of slop tanks
depends on the Dead weight Tonnage (DWT) of the vessel.
Sludge tank
Located in engine room, this tank is used to store sludge produced after treating fuel or lube oil through purifiers.
Bilge tank
The water and oil leakage in the engine room is collected in bilge wells and this oily water mixture is then transferred to
primary bilge tank or bilge holding tank, where the mixture is settled down and then is transferred to secondary bilge
tank.
connected to this tank to dispose off all the collected bilge to shore.
The sludge produced by the main engine in the scavenge area is collected in the small capacity scavenge drain tank.
When oily water separator operates, it separates oil from water and that oil is collected and discharged into a separate
tank known as O.W.S sludge tank.
Drain tank
The drain tank is located in the engine room. All drip trays and other drains are connected to this tank.
This is a small tank separately fitted in the main engine and all auxiliary engines to detect any fuel leakage. The tank
consists of an orifice and a float. If the leak is very small, it will pass through the orifice; but if leakage increases, the oil
will not be able to pass through the orifice and tank level would increase, rising the float and thus giving an alarm.
The main engine stuffing box scraps the impure lubricating oil, which is collected in a separate tank known as stuffing
box tank.
The stern tube system oil is circulated in the system by means of two tanks, lower gravity and upper gravity tanks.
The waste oil tank is a separate tank used to collect waste and impure oil produced onboard ship.
When the economiser tube washing is done, the soot water is collected in a soot collecting tank.
The sewage produced from the onboard crew is collected in a common tank known as sewage collecting tank. The
sewage plant takes intake from the sewage holding tank.
Expansion tanks
The jacket water system of main engine, auxiliary engine and some times main air compressor are provided with
individual expansion to provide provision to compensate change in volume and maintaining positive pressure.
Jacket water drain tank
When any maintenance is to be done on the main engine, the jacket water is drained and collected into the jacket water
drain tank.
Many diesel generators are provided with separate rocker arm lubricating oil tank to avoid contamination.
You may also like to read Fresh Water Generator & Ballast Water Management plan
Image Credits:
norherntool
chazsworld
ssmaritime
nauticexpo
Report an Error
Next Read: 10 Main Personal Protective Equipment (PPE) Used Onboard Ship »
List is good, but stern tube cooling water tank is forgotten and may be considered as No1 Not-So-Famous yet Important Tank.
Thanks for your valuable suggestion. The tank has been added in the list.
Hi Anish
Very interesting article. I do have a question about the function of a cascade tank.
1) Is this the same tank where the wasted steam from the heating coils for fuel oil storage tanks is condensed into the cascade tank?
2) also if any heating coils are damaged or leaking it would contaminate the cascade tank by the oil entering into the cascade tank and
vice versa that is water from the cascade tank will enter the fuel storage tanks through the heating coils thus in turn contaminating the
fuel oil
Johsie
3)
@ Joshie:
1. Yes. The return steam (wasted steam) is condensed and sent back to cascade tank.
2. Yes, if their is oil leakage in a heating coil it will come into cascade tank. Cascade tank is provided with an observation glass
with a light lit at the background to detect floating impurities and oil contamination since oil having lighter density will float up.
The suction of the boiler feed water pump which supplies water to boiler drum is taken from the bottom of the cascade tank to
ensure less oil goes to boiler, if the tank gets contaminated. Now a days cascade tank is provided with continually measuring
oil detecting device and filters to absorbs small oil quantity.
You can also post your questions in our forum to get multiple and speedy replies: http://forums.marineinsight.com
@ Anish:
Hi Anish - During gauging of FO tanks I have come across a similar situation where the C/E told me that # 2 FO Tank (Storage Tank)
was contaminated with water and is thus unusable.
Reading the above discussions that would mean that in case of rupture of the heating coils the return steam line would carry with it oil
from the storage tank into the cascade tank but how does the water enter the storage tank? I presume the leaking steam coils will be
releasing steam (condensing to water) into the storage tank? Am I correct in saying that and if so then 2 things would happen:
a) Steam consumption will increase because the steam is being 'wasted' into the storage tank (instead of heating the oil)
b) FW consumption will increase because the Cascade Tank level will continuously decrease and so regular top-up would be required
(this was also reported by the C/E that water level in the cascade tank was decreasing)
Meaning to say that if steam consumption increases or FW consumption increases then this would be a sign that heating coils may
have been damaged?
Thanks/kc
@ KC : If the heating lines are at higher pressure than the content they are heating (here oil), steam will leak out of the coil to
low pressure system. The level (in this case- "head") of the concerned bunker tank will be less to suppress the steam pressure
causing the leakage.
a) Steam consumption will definitely increase as it is leaking out of the closed system.
b) Increase in F.W consumption is not a sure shot troubleshooting for steam leakage unless the fresh water tank is only used
for boiler cascade tank filling. Increase in F.W consumption can be due to several other reasons as F.W is supplied to various
machinery and to accommodation. The rate of fall of cascade tank level can be used as a reference for steam leakage.
Dear Anish, I used to be a marine engineer some 20years ago. Can you provide me a typical design of cascade tank on board.
Regards
what are individual function of upper and lower header tank of stern tube
header thank.
To maintain the lubrication system for ships with variable draught (due to loading and unloading of cargo), header tanks are
provided at around 2 to 3 meters above the water line so that the differential pressure ensures no water ingress.
Hi anish, excellent information. I am non marine person but recently came across that slops and sludge discharged from ship can be
sold to petro chemicals. Is it true?
LEAVE A COMMENT
Recent Posts
Panama Canal Ensures Compliance With Health And Prevention Of Contagious Diseases
March 16, 2020
ClassNK Grants AiP On LPG Reformed Gas Fueled Coastal LPG Carrier
March 16, 2020
Coronavirus (COVID-19) – WHO Declares Europe Epicenter Of Pandemic And Nations Close Borders
March 16, 2020
Privacy Policy About Us Advertise Contact Us