2. Attachments Process Description Protection system operation Cause and effect diagrams and charts 3. Processor Single Dual Triple Hot stand–by 2 out of 3 voting Self–checking 4. Modules Input–Single Dual Triple Output–Single Dual Triple 5. Logic cabinet Integral complete with processors and I/O modules Separate I/O cabinet Separate processor cabinet 6. Bypass switch Key–lock type on each field input and output circuit Mounting–integral cabinet I/O cabinet Processor cabinet 7. Alarm annun. Class 1 Class 2 First–failure indication Mounting–console Integral Cabinet Processor cabinet 8. Enclosure Safe area Classified Class Group Div Weatherproof Ex. Proof Intr. safe STD. Temp. Class T1 T2 T3 T4 T5 T6 9. Power Supply 110 V 60Hz 24 Volts D.C A.C. and D.C. isolation switches and fuses Auxiliary redundant type 24 volts D.C. supply for I/O modules 10. Logic circuits Solid state Mil. Spec. 11. Automatic testing I/O module Error Detection and fault identification 12. Documentation Self generated by system Program with functional description System configuration Cross referenced listing of Tag No and program use locations 13. Inputs Digital–volt free. programmable open or close Analog– 0 to 20 m.A. 12–Bit resolution Out of range detection 24 volts D.C. supply to trans. Thermocouple–ISA Type selection 12–Bit resolution Automatic cold junction compensation Input open circuit detection Linearization and range adjustment R.T.D.–Type selection 2/3/4 wire system compatible 12–Bit resolution Linearization and range adjustment 13. Outputs Digital–contacts programmable open or close 24 Volts D.C. output voltage Analog 0 to 20 m.a. 12–BitResolution Ports – to communicate with computer systems 14. Printer One Two Mounting: 15. CPU Features Real time clock with battery back–up Keylock user password to prevent unauthorized changes Engineer’s CRT and keyboard for system verification and reprogramming 16. Memory Expandible non–volatile with periodic automatic check Eprom 17. Cabinet Features Chassis and circuit earthing terminals 18. Manual To bypass logic unit and permit direct initiation of output device pushbuttons Mounted on processor cabinet Supplied loose for remote mounting 19. Acceptance tests Factory–intermediate at each stage completion of: Hardware Software Heat soak –Full functional with all I/O and bypass switches to resemble site operation 20. Documentation 1) to be supplied 2) 3) 4) 5)
Notes: 1. All items shall be tropicalised.
2. All items mounted outside control room shall be corrosion resistant to marine atmosphere.