Sunteți pe pagina 1din 7

KLAUS Multiparking GmbH

Hermann-Krum-Straße 2
PRODUCT DATA
D-88319 Aitrach
Fon +49 (0 ) 75 65 5 08-0
Fax +49 (0 ) 75 65 5 08-88
info@multiparking.com
www.multiparking.com
Outdoor installation
Page 1 Dimensions
Section
All space requirements are minimum
Car data
finished dimensions.
Tolerances for space
Page 2 requirements + 03 [+ 01’’ ] 2
Height
dimensions EB (single platform) = 2 vehicles

Dimensions: cm [ft] (1 cm = 0,393 in)


Barrier 5

Weights: kg [lbs] (1 kg = 2.2 lbs)


Page 3
Forces: kN [lbf] (1 kN = 224.8 lbf)
Function
Width
Temperature: °C [°F] (0° C = 32° F)
dimensions
Approach Suitable for

Page 4
Standard passenger cars:
Load per
Limousine, Station Wagon, SUV, Van
parking 6
according to clearance and maximum
space surface load.
Delimitation
Load plan
Standard Special 1
Page 5 width 190 cm [6‘-3‘‘] 3 190 cm [6‘-3‘‘] 3
Electrical Grounding 4
installation weight see page 4
520 [17‘-1‘‘] for vehicle up to 5.00 m [16‘-5‘‘] long 7 wheel load see page 4
Clearance profile
(540 [17‘-9‘‘] for vehicle up to 5.20 m [17‘-1‘‘] long)
Page 6 30
Technical
data
160 [5‘-3‘‘] [12‘‘]

Before lowering the platform, the vehicle parked on the lower

[1‘-10‘‘]
[1‘-6‘‘]
parking space must be driven off!

45

55
see table
Page 7 15° 13°
To be perfor-

100 125
med by the [3‘-3‘‘] [4‘-1‘‘]
customer
500 (520)

Description
[16‘-5‘‘ (17‘-1‘‘)]

Height dimensions
See page 2 for all height dimensions.

[6‘-11‘‘]
210
[5‘-3‘‘]
160

Smallest type Biggest type


SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018

1 Special system: maximum load for extra charge. 5 Three-sided barrier compliant to DIN EN ISO 13857.
2 To follow the minimum finished dimensions, make sure Depending on location, design also as wind protection.
to consider the tolerances according to VOB, part C 6 In compliance with DIN EN 14010, 10 cm [4’’] wide yellow-black
(DIN 18330 and 18331) and the DIN 18202. markings compliant to ISO 3864 must be applied by the
3 Car width for platform width 230 cm [7’-7’’]. If wider platforms customer to the edge of the platform in the access area to
are used it is also possible to park wider cars. mark the danger zone in front of the supporting surface of
the upper platform edge (see „Load Plan“ Page 4).
4 Potential equalization from foundation grounding connection
to system (provided by the customer). 7 For convenient use of your parking space and due to the fact
that the cars keep becoming longer we recommend
a length of 540 cm [17’-9’’].
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 2 of 7
Page 1
Height dimensions
Section
Car data 2061-160 [5’-3’’] 2061-170 [5’-7’’] 8

Page 2
Height
dimensions

Page 3
Function

[5‘-7‘‘]
[5‘-3‘‘]

170
Width dim.

160
Approach

Page 4
Load per
parking
Car height lower level Car height lower level
space 150 [4‘-11‘‘] 160 [5‘-3‘‘]
Load plan

Page 5 2061-180 [5’-11’’] 2061-190 [6’-3’’]


Electrical
installation

Page 6
Technical
data
[5‘-11‘‘]

[6‘-3‘‘]
190
180

Page 7
To be perfor-
med by the
customer
Description
Car height lower level Car height lower level
170 [5‘-7‘‘] 180 [5‘-11‘‘]

2061-200 [6’-7’’] 2061-210 [6’-11’’]

[6‘-11‘‘]
[6‘-7‘‘]

210
200

Car height lower level Car height lower level


190 [6‘-3‘‘] 200 [6‘-7‘‘]

To the extent that the conditions of the construction do not restrict the height, the car height on the upper parking
slots is not restricted.

8 Standard type
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 3 of 7
Page 1
Function
Section
Car data System lifted System lowered

Page 2
Height
dimensions

Page 3
Function
Width
dimensions
Approach

Page 4 Width dimensions


Load per
parking
space Single Platform (EB)
Load plan Usable platform width B1
230 [7‘-7‘‘ ] 260 [8‘-6‘‘ ]
Page 5 240 [7‘-10‘‘ ] 270 [8‘-10‘‘ ]
Electrical 250 [8‘-2‘‘ ] 280 [9‘-2‘‘ ]
installation 260 [8‘-6‘‘ ] 290 [9‘-6‘‘ ]
EB 270 [8‘-10‘‘] 300 [9‘-10‘‘]

Page 6
Technical
data
B1 Carriageway in
accordance with
local regulations
Page 7
To be perfor-
med by the
customer For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm [8’-10’’].
Description Problems may occur if smaller platform widths are used (depending on car type, access and individual driving behaviour
and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).

Approach

maximum maximum
descending ascending
slope 4 % slope 14 %

The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious
maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking
accepts no responsibility.
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 4 of 7
Page 1
Load per parking space
Section
Car data For countries where snow loads For countries where snow loads is
are a crucial factor (weights in kg) no relevant factor (weights in kg)

Page 2 SingleVario 2061 2,0 to. (only EB) SingleVario 2061 2,0 to. (only EB)
Height
dimensions
parking spaces weight wheel load parking spaces weight wheel load
upper parking space 1500 kg 375 kg upper parking space 2000 kg 500 kg

SingleVario 2061 2,6 to. (only EB) – for extra charge SingleVario 2061 2,6 to. (only EB) – for extra charge
Page 3
Function
parking spaces weight wheel load parking spaces weight wheel load
Width upper parking space 2000 kg 500 kg upper parking space 2600 kg 650 kg
dimensions
Approach
For countries where snow loads For countries where snow loads is
Page 4 are a crucial factor (weights in lbs) no relevant factor (weights in lbs)
Load per
parking SingleVario 2061 4400 lbs (only EB) SingleVario 2061 4400 lbs (only EB)
space
Load plan
parking spaces weight wheel load parking spaces weight wheel load
upper parking space 3300 lbs 830 lbs upper parking space 4400 lbs 1100 lbs
Page 5
Electrical SingleVario 2061 5730 lbs (only EB) – for extra charge SingleVario 2061 5730 lbs (only EB) – for extra charge
installation
parking spaces weight wheel load parking spaces weight wheel load
upper parking space 4400 lbs 1100 lbs upper parking space 5730 lbs 1400 lbs

Page 6
Technical Applies to a snow depth of 20 cm [8’’]; in case of larger snow depths the snow must be removed.
data

Load plan
Page 7
To be perfor-
med by the
customer
Description lateral support 9 Dimensions
A1 300 [9‘-10‘‘ ]
A2 245 [8‘-0‘‘ ]
F6 A3 290 [9‘-6‘‘ ]
F6 A1 A4 115 [3‘-9‘‘ ]
A5 LP+10 [LP+4‘‘]
A6 12 [0‘-5‘‘ ]

Platform load in kg
A1
F5
F5 F4 Platform load F1 F4 F5 F6 11

2000 kg +30 +0,5 +7,7 ±1


F4
F1 2600 kg +36 +0,7 +9,8 ±1
A6 A5
Platform load in lbs
A2 F1
A3
A4 Platform load F1 F4 F5 F6 12
Marking 10
4400 lbs +6,744 +112 +1,731 ±225
5730 lbs +8,093 +157 +2,203 ±225

Units are dowelled to the floor. Drilling depth: approx. 15 cm [6’’].


Floor and walls are to be made of concrete (quality minimum C20/25)!
The dimensions for the points of support are rounded values. If the exact position is required, please contact
KLAUS Multiparking.

9 The system must be laterally supported on both sides. If there are no walls on the sides, an additional stand must be attached.
For this stand, a base area of 40 x 25 cm [1’-4’’ x 10’’] is required (quality minimum C20/25).
10 Marking compliant to ISO 3864 (colors used in this illustration are not ISO 3864 compliant)
11 All forces in kN
12 All forces in lbf
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 5 of 7
Page 1
Electrical installation
Section
Car data Installation diagram Electrical data (to be performed by the customer)
No. Qunatity Description Position Frequency
1
Page 2
1 1 Electricity meter in the supply
2 line
Height
dimensions 3 2 1 Main fuse:
3 x fuse 16 A (slow) in the supply 1 per
or circuit breaker 3 x 16 A line 3,0 kW
6 (trigger characteristic K or C) unit
Page 3 2 x fuse 32 A (slow) in the supply 1 per
Function or circuit breaker 2 x 32 A line 3,7 kW
Width 13 7 (trigger characteristic K or C) unit
dimensions 3 x fuse 25 A (slow) in the supply 1 per
Approach 11 or circuit breaker 3 x 25 A line 4,0 kW
12 15 10 (trigger characteristic K or C) unit

[5‘-11‘‘]
Page 4

180
3
Load per
1 Supply line 5 x 2,5 mm2 to main switch 1 per
parking
(3 PH + N + PE) with marked 3,0 kW
space
Stand for wire and protective conductor unit

[3‘-11‘‘]
120
Load plan
8 9 operating device Supply line 4 x AWG 10 to main switch 1 per
(2 PH + PE) with marked wire 3,7 kW
14 0,00
and protective conductor unit
Page 5
Electrical
Supply line 4 x AWG 12 to main switch 1 per
installation
(3 PH + PE) with marked wire 4,0 kW
4 5 and protective conductor unit
4 every Foundation earth connector corner pit floor
to the next 10 m
system
Page 6 5 1 Equipotential bonding in accordance 1 per
Technical with DIN EN 60204 from foundation system
data earth connector to the system

Electrical data (included in delivery of KLAUS Multiparking)


Page 7 No. Description
To be perfor-
med by the 6 Lockable main switch
customer 7 Supply line 5 x 2,5 mm2 (3 PH + N + PE) with marked wire and
Description protective conductor (for 3,0 kW unit)
Supply line 4 x AWG 10 (2 PH + PE) with marked wire and
protective conductor (for 3,7 kW unit)
Supply line 4 x AWG 12 (3 PH + PE) with marked wire and
protective conductor (for 4,0 kW unit)
8 Terminal box
9 Control line 3 x 0.75 mm2 (PH + N + PE)
10 Control line 7 x 1.5 mm2 with marked wire and protective conductor
11 Operating device
12 Control line 5 x 1.5 mm2 with marked wire and protective conductor
13 Hydraulic unit 3,0 kW, three-phase current, 230/400 V / 50 Hz
Hydraulic unit 3,7 kW, two-phase current, 240 V / 60 Hz
Hydraulic unit 4,0 kW, three-phase current, 120/208 V / 60 Hz
14 Control line 5 x 1.5 mm2 with marked wire and protective conductor
15 Chain control
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 6 of 7
Page 1
Technical data
Section
Car data Field of application Building application documents
By default, the system can only be used for a fixed number of According to LBO and GaVo (garage regulations) the Multiparking
users. systems are subject to approval. We will provide the required
Page 2 If different users use the system – only on the upper parking building application documents.
Height
dimensions
spaces – (e.g. short-time parkers in office buildings or hotels)
the Multiparking system needs to be adjusted. If required, Care
would you please contact us. To avoid damages resulting from corrosion, make sure to follow
our cleaning and care instructions and to provide good ventilation
Page 3 Units of your garage.
Function Low-noise power units mounted to rubber-bonded-to metal
Width mountings are installed. Nevertheless we recommend that parking Corrosion protection
dimensions
Approach
system’s garage be built separately from the dwelling. If it is not See separate sheet regarding corrosion protection.
possible to install the hydraulic power units with the solenoid valves
Page 4 in adjacent buildings or spaces, the power unit and the solenoid CE Certification
valves must be housed in a cabinet (at an extra charge).
Load per
parking
The systems on offer comply with DIN EN 14010 and
space Available documents EC Machine Directive 2006/42/EC. Furthermore, this system
Load plan underwent voluntary conformity testing by TÜV SÜD.
– wall recess plans
Page 5 – maintenance offer/contract
Electrical – declaration of conformity
installation – test sheet on airborne and slid-borne sound

Gap covers
Page 6
Any existing gaps between the systems or the platforms and the
walls must be reduced to approx. 10 cm [4’’] by installing sheet-
Technical
data metal covers (at an extra charge).

Environmental conditions
Environmental conditions for the area of multiparking systems:
Page 7
Temperature range –20 to +40° C [–4 to +104° F].
Relative humidity 50% at a maximum outside temperature
To be perfor-
med by the
customer of +40° C [+104° F].
Description If lifting or lowering times are specified, they refer to an
environmental temperature of +10° C [+50° F] and with the
system set up directly next to the hydraulic unit. At lower
temperatures or with longer hydraulic lines, these times
increase.

Sound insulation
As per DIN 4109-1 (sound insulation in building construction),
Section 9, KLAUS Multiparker are in the range of technical
domestic installations (garage systems).

Normal sound insulation:


DIN 4109-1, Section 9, maximum permissible A-rated sound
levels in rooms requiring external protection, generated by
technical domestic installations and commercial businesses
affiliated with the building.
Table 9 shows the values for the maximum permissible A-rated
sound levels in rooms requiring external protection, generated
by technical domestic installations and business affiliated with
the building. As per line 2, the maximum sound level in living
rooms and bedrooms must not exceed 30 dB (A). User noises
are not subject to the requirements (DIN 4109-1, Section 9).
The following measures are required to comply with this value:
– Sound protection package according to offer/order
(KLAUS Multiparking GmbH)
– Minimum sound insulation of the building of min. R’w = 57 dB
(service/item to be provided by the customer)

Increased sound insulation (special agreement):


VDI 4100 (sound insulation in building construction)
Assessment and proposals for enhanced sound insulation.
Agreement: Maximum sound level in living rooms and
bedrooms 25 dB (A). User noises are not subject to the
requirements (see VDI 4100, Paragraph 1, Scope of
application – Notes).
The following measures are required to comply with this value:
– Sound protection package according to offer/order
(KLAUS Multiparking GmbH)
– Minimum sound insulation of the building of min. R’w = 62 dB
(service/item to be provided by the customer)

Note: User noises are basically noises that can be individually


influenced by the user of our Multiparking systems. These
include, for example, driving on the platform, slamming vehicle
doors, engine and brake noises.
SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Page 7 of 7
Page 1
To be performed by the customer
Section
Car data Safety fences Electrical supply to the main switch / Foundation earth connector
Constraints according to DIN EN ISO 13857 must be put in place Suitable electrical supply to the main switch must be provided by
on three sides (all except the entrance side), unless buildings border the customer during installation. The functionality can be monitored
Page 2 the traffic ways around the system. on site by our fitters together with the electrician. If this cannot be
Height done during installation for some reason for which the customer is
Numbering of parking spaces
dimensions
responsible, the customer must commission an electrician at their
Consecutive numbering of parking spaces. own expense and risk.
In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Page 3 Building services Equipment), grounding of the steel structure is necessary, provided
Function
Any required lighting, ventilation, fire extinguishing and fire alarm by the customer (distance between grounding max. 10 m [32’-10’’]).
Width
systems as well as clarification and compliance with the relevant
If the following are not included in the quotation, they will
dimensions
Approach regulatory requirements.
also have to be provided / paid for by the customer:
Page 4 Marking – Mounting of contactor and terminal box to the wall valve,
Load per
parking In compliance with DIN EN 14010, 10 cm [4’’] wide yellow-black complete wiring of all elements in accordance with the circuit
space markings compliant to ISO 3864 must be applied by the customer diagram
Load plan to the edge of the platform in the access area to mark the danger – Costs for final technical approval by an authorized body
zone in front of the supporting surface of the upper platform edge. – Main switch
Page 5 – Control line from main switch to hydraulic unit
Electrical Wall cuttings
installation
Any necessary wall cuttings according to page 1.

Page 6
Description Single platform (EB)
Technical
General description Hydraulic system consisting of:
data

Multiparking system providing dependent parking spaces for 2 cars – Hydraulic cylinder
one on top of the other each. The lower vehicle parks directly on the – Solenoid valve
Page 7 floor plate. The vehicle parked on the bottom must be driven out – Safety valve
To be perfor- before lowering the platform. – Hydraulic conduits
med by the
customer The height of the platform can be adjusted flexibly (even subse- – Screwed joints
Description quently). – High-pressure hoses
– Installation material
Dimensions are in accordance with the underlying dimensions of
the building, height and width. Electric system consisting of:
The parking bays are accessed horinzotally (installation deviation – Operating device (Emergency Stop, lock, 1 master key per
± 1%). parking space)
Vehicles are positioned on the upper parking space using wheel – Terminal box at wall valve
stops on the right side (adjust according to operating instructions). – Electrical locking device
Operation via operating device with hold-to-run-device using – Chain control
master keys.
Hydraulic unit consisting of:
Operating instructions are attached to each operator's stand.
– Hydraulic power unit (low-noise, installed onto a console with
Multiparking system consisting of: a rubber-bonded-to-metal mounting)
– Hydraulic oil reservoir
– 2 steel pillars with bases that are mounted on the floor – Oil filling
– 2 sliding platforms (mounted to the steel pillars with sliding bearings) – Internal geared wheel pump
– 1 platform – Pump holder
– 1 mechanic synchronization control system (to ensure – Clutch
synchronous operation of the hydraulic cylinders while lowering – AC-motor
and lifting the platform) – Contactor (with thermal overcurrent relay and control fuse)
– 1 hydraulic cylinder – Test manometer
– 1 automatic hydraulic safety valve (prevents accidental lowering – Pressure relief valve
of the platform while accessing the platform) – Hydraulic hoses (which reduce noise transmission onto the
– Dowels, screws, connecting elements, bolts, etc. hydraulic pipe
– The platforms and parking spaces are end-to-end accessible
for parking!

Platforms consisting of:


– Platform base sections
– Adjustable wheel stops
– Canted access plates
– Side members
– Cross members
– Screws, nuts, washers, distance tubes, etc.

We reserve the right to change this specification without further notice


KLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes,
procedures or standards in the fulfillment of their obligations other than those originally offered provided the customer derives no