Sunteți pe pagina 1din 6

APPENDIX D

SUBSTRUCTURE STIFFNESS
CALCULATION IN STAAD
Job No Sheet No Rev
21Aerocity 1 R0

Part (Stiffness calculation of Substructure)


Software licensed to SPACPL
Job Title 21Aerocity Ref

By UMP Date07-02-2020 Chd DSG


Client DMRC File Pier Stiff Date/Time
Calc_P152_2.00m dia Pier-1.0m
26-Mar-2020
dia 4 Pile.std
19:23

12.473m

3
401
3 1.800m
301
4

Y 3.500m
601

X 501 3.500m
401

Z 301
601

6.240m
501
402

302
602 Load 1
502

Print Time/Date: 26/03/2020 19:23 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 1 of 1
Job No Sheet No Rev
21Aerocity 1 R0

Part (Stiffness calculation of Substructure)


Software licensed to SPACPL
Job Title 21Aerocity Ref

By UMP Date07-02-2020 Chd DSG


Client DMRC File Pier Stiff Date/Time
Calc_P152_2.00m dia Pier-1.0m
26-Mar-2020
dia 4 Pile.std
19:23

1 0.422 mm

2 0.338 mm

30.057 mm
401
0.051 mm

Y 0.051 mm
301
X
40.050 mm
601
0.051 mm

Z 0.051 mm
501

402
302 Load 1 : Displacement
602 Displacement - mm
502

Print Time/Date: 26/03/2020 19:25 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 1 of 1
Thursday, March 26, 2020, 07:25 PM
PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.70 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= MAR 26, 2020 *
* Time= 19:23:27 *
* *
* USER ID: SPACPL *
****************************************************

1. STAAD SPACE
INPUT FILE: C:\30TA\Substructure Analysis\Metro\P152\STAAD\Substructure stiffness calc\Pier Stiff Calc.. .STD
2. START JOB INFORMATION
3. JOB NAME 21AEROCITY
4. JOB CLIENT DMRC
5. JOB NO 21AEROCITY
6. JOB PART (STIFFNESS CALCULATION OF SUBSTRUCTURE)
7. ENGINEER NAME UMP
8. CHECKER NAME DSG
9. ENGINEER DATE 07-02-2020
10. JOB REV R0
11. END JOB INFORMATION
12. UNIT METER KN
13. JOINT COORDINATES
14. *METRO PIERCAP TOP LVL - 248.451 M
15. *METRO PIERCAP BOTTOM LVL - 246.451 M
16. *PILECAP TOP LVL - 235.978 M
17. *PILECAP DEPTH - 1.8 M
18. *DEPTH OF FIXITY OF PILES = 6.24 M
20. 1 0 248.451 0
21. 2 0 246.451 0
22. 3 0 235.978 0
23. 4 0 234.178 0
24. 301 -1.75 234.178 -1.75
25. 302 -1.75 227.938 -1.75
26. 401 1.75 234.178 -1.75
27. 402 1.75 227.938 -1.75
28. 501 -1.75 234.178 1.75
29. 502 -1.75 227.938 1.75
30. 601 1.75 234.178 1.75
31. 602 1.75 227.938 1.75
33. MEMBER INCIDENCES
34. 1 1 2; 2 2 3; 3 3 4
35. 301 301 302
36. 401 401 402
37. 501 501 502
38. 601 601 602
39. SUPPORTS
40. 302 402 502 602 FIXED

C:\30TA\Substructure Analysis\Metro\P152\STAAD\Substructure stiffness calc\Pier Stiff Calc_P152_2.00m dia Page


Pier-1.0m
1 of 4dia 4
Thursday, March 26, 2020, 07:25 PM
STAAD SPACE -- PAGE NO. 2

41. DEFINE MATERIAL START


42. ISOTROPIC MATERIAL1
43. E 34000000
44. POISSON 0.2
46. DENSITY 25
47. END DEFINE MATERIAL
48. CONSTANTS
49. MATERIAL MATERIAL1 ALL
50. MEMBER PROPERTY
51. *AS PER IRC SP 114-2018, IEFF=0.75IG,
52. *MI OF METRO PIER (UNCRACKED) = 0.785 M4
53. *MI OF CRACKED = 0.75* 0.785 = 0.589 M4
54. 1 2 PRIS AX 3.142 IY 0.589 IZ 0.589 IX 0.773
55. 3 PRIS YD 5 ZD 5
56. *MI OF PILE (UNCRACKED) = 0.049 M4
57. *MI OF CRACKED = 0.75* 0.049 = 0.037 M4
58. 301 401 501 601 PRIS AX 0.785 IY 0.037 IZ 0.037 IX 0.074
60. SLAVE RIGID MASTER 4 JOINT 301 401 501 601
61. LOAD 1
62. JOINT LOAD
63. 1 FX 10
64. LOAD 2
65. JOINT LOAD
66. 1 FZ 10
67. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 12 NUMBER OF MEMBERS 7


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 4

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 12 DOF


TOTAL PRIMARY LOAD CASES = 2, TOTAL DEGREES OF FREEDOM = 24
TOTAL LOAD COMBINATION CASES = 0 SO FAR.
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 165209.3 MB

68. PRINT JOINT DISPLACEMENT

C:\30TA\Substructure Analysis\Metro\P152\STAAD\Substructure stiffness calc\Pier Stiff Calc_P152_2.00m dia Page


Pier-1.0m
2 of 4dia 4
Thursday, March 26, 2020, 07:25 PM
STAAD SPACE -- PAGE NO. 3

JOINT DISPLACEMENT (CM RADIANS) STRUCTURE TYPE = SPACE


------------------

JOINT LOAD X-TRANS Y-TRANS Z-TRANS X-ROTAN Y-ROTAN Z-ROTAN

1 1 0.0422 0.0000 0.0000 0.0000 0.0000 -0.0000


2 0.0000 0.0000 0.0422 0.0000 0.0000 0.0000
2 1 0.0338 0.0000 0.0000 0.0000 0.0000 -0.0000
2 0.0000 0.0000 0.0338 0.0000 0.0000 0.0000
3 1 0.0057 0.0000 0.0000 0.0000 0.0000 -0.0000
2 0.0000 0.0000 0.0057 0.0000 0.0000 0.0000
4 1 0.0050 0.0000 0.0000 0.0000 0.0000 -0.0000
2 0.0000 0.0000 0.0050 0.0000 0.0000 0.0000
301 1 0.0050 0.0006 0.0000 0.0000 0.0000 -0.0000
2 0.0000 0.0006 0.0050 0.0000 0.0000 0.0000
302 1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
401 1 0.0050 -0.0006 0.0000 0.0000 0.0000 -0.0000
2 0.0000 0.0006 0.0050 0.0000 0.0000 0.0000
402 1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
501 1 0.0050 0.0006 0.0000 0.0000 0.0000 -0.0000
2 0.0000 -0.0006 0.0050 0.0000 0.0000 0.0000
502 1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
601 1 0.0050 -0.0006 0.0000 0.0000 0.0000 -0.0000
2 0.0000 -0.0006 0.0050 0.0000 0.0000 0.0000
602 1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

************** END OF LATEST ANALYSIS RESULT **************

69. FINISH

C:\30TA\Substructure Analysis\Metro\P152\STAAD\Substructure stiffness calc\Pier Stiff Calc_P152_2.00m dia Page


Pier-1.0m
3 of 4dia 4