Sunteți pe pagina 1din 3

DESIGN OF NEIGHBOR FOOTING

PROJECT : GARAGE

FOOTING NO: CHECK F1*

DESIGN DATA :
SBC of Soil = 100 kN/m2 Concrete grade fcu = 40 N/mm2 Bottom cover of Footings = 75 mm

Depth of Overburden = 0.75 m Steel grade fy = 460 N/mm2 Side cover of Footings = 50 mm

Density of Soil = 18 kN/m 3


Net SBC = 86.5 kN/m 2
Cover to Strap Beam = 50 mm

COLUMNS DATA ECCENTRIC FOOTING F1 & STRAP BEAM DATA

Parameters Column 1 Column 2 Parameters Required Provided

Ultimate load Pu1= 324 kN Pu2= 324 kN Width of Footing W1 = 1.60 m W1 = 1.60 m

Width of column a1 = 200 mm a2 = 200 mm Length of Footing L1 = 1.78 m L1 = 1.37 m

Depth of column b1 = 400 mm b2 = 400 mm Depth of Footing Df1 = 0.30 m Df1 = 0.30 m

Distance between l = 3.40 m c/c Area of Footing Ar= 2.84 m2 Ap= 2.19 m2
columns
Width of Strap Beam " B " = 200 mm
STB

Depth of Strap Beam " D " = 400 mm

Pu1= 324 kN Pu2= 324 kN

STB D
Df1
0.30
A
0.70 2.70 m O
x 6 # Y 20
R l = 3.40 m

1.40
Y Y10 @150 c/c
a1 F1 F2
400

2 # Y 16
1.37

b1
1
L

X
0.49

W1
200
1.60

C.S OF STB
REACTION " R " UNDER FOOTING F1
Taking moments about point "O"

R = Pu1*l / (l-x) R= 408.00 kN


DESIGN OF STRAP BEAM:
Taking moments about point "A", MA = Pu1*(x+W1/2)-(R*W1/2) Width of Strap Beam " B " = 200 mm
MA = 159.60 kN-m (Ultimate) Depth of Strap Beam " D " = 400 mm
Ast1 = (0.5*fcu / fy)*[1-sqrt{1-(4.6*Mu1/ fcu*b*d )}]b*d 2
Effective Depth " d "= 340.00 mm
Area of Tensile Steel 'Ast '= 1614 mm2

Hence, Provide: 6 Nos. 20 mm TOP BARS


and 2 Nos. 16 mm BOTTOM BARS and 10T stirrups @ 150mm c/c
DESIGN OF ECCENTRIC FOOTING F1: Size of Footing Provided:

Total Load on Footing = 324 kN Width of Footing W1 = 1.60 m

Net SBC = 86.50 kN/m2 Length of Footing L1 = 1.37 m


Area of Footing required " Af "= 2.84 m2 Depth of Footing Df1 = 0.30 m

Net Upward Soil Pressure " NUPI " = 147.81 kN/m2 Effective Depth of Footing d = 219.00 mm
DESIGN OF FOOTING IN X - DIRECTION:

MOMENTS REINFORCEMENT

In X - Direction only nominal steel min. Ast = 0.15%bd

is provided min Ast = 450 mm2

Spacing of 12 dia bars = 319 mm c/c

Provide, 12 dia bars @ 200 mm c/c at Bottom of footing.


Astx(prov) = 718 mm2 ptx(provided) = 0.24 %

DESIGN OF FOOTING IN Y - DIRECTION:

MOMENTS REINFORCEMENT
Moment at the face of column ' M x' Asty = (0.5*fcu / fy)*[1-sqrt{1-(4.6*Mu1/ fcu*b*d2)}]b*d min. Ast = 0.15%bd

M x = NUPI*W1*(L1-b)2/2 Asty = 644 mm2 min Ast = 526 mm2

Mx= 55.21 kN-m Spacing of 12 dia bars = 263 mm c/c

Provide, 12 dia bars @ 200 mm c/c at Bottom of footing.


Asty(prov) = 848 mm2 pty(provided) = 0.24 %

CHECK FOR ONE WAY SHEAR:

Critical Section for Shear Force Shear Stress Shear Strength S.S. =

one-way Shear V in kN ' v ' in N/mm 2


of Concrete Vc 0.8*(fcu)1/2 Results

as perTable:3.9

A) In X - Direction

1) at the face of Column 284 0.945 ---- 5.060 Safe in oneway shear

2) at a distance of 1.5*d 217 0.723 0.416 ---- Revise depth of footing

from face of Column

B) In Y - Direction

1) at the face of Column 162 0.461 ---- 5.060 Safe in oneway shear

2) at a distance of 1.5*d 84 0.239 0.418 ---- Safe in oneway shear

from face of Column

1.5d

1.5d
CRITICAL SECTIONS FOR ONE WAY SHEAR

S-ar putea să vă placă și