Sunteți pe pagina 1din 27

FEB 2018

SEISMIC
BRACING GUIDE
PARTITIONS & CEILINGS
NEW ZEALAND
SECOND EDITION

Available from
CONTENTS/
About us 2
TRACKLOK® Range 3
Features and Benefits 4
Install Instructions & Plenum Guidance 5
TRACKLOK® Plan & Elevations 6
Seismic Zone Chart 7
Setout Chart One 8
Setout Chart Two 9
Setout Chart Three 10
GAPLOK 11
TRACKLOK® FLAT 13
Features and Benefits 14
Install Instructions 15
TRACKLOK® FLAT Plan & Elevations 15
TRACKLOK® FLAT Partition Elevations 16
Top Connections
Concrete Connection Detail 18
Comflor Connection Detail 19
Parallel Steel Connection Detail 20
Perpendicular Steel Connection Detail 21
Parallel Timber Connection Detail 22
Perpendicular Timber Connection Detail 23
Bridging and Bulkheads
Parallel Bridge Detail 24
Perpendicular Bridge Detail 25
Parallel & Perpendicular Bridge Notes 26
Service Bridge Detail 27
Service Bridge Notes 28
Bulkhead Bracing Detail 29
Bulkhead Bracing Notes 30
GRIDLOK® 31
GRIDLOK® Range 32
Features and Benefits 33
Install Instructions & Plenum Guidance 34
GRIDLOK® Isometric 35
GRIDLOK® Peak Form Isometric 36
GRIDLOK® Kwikloc Isometric 37
GRIDLOK® Top Cross Rail (TCR) Isometric 38
GRIDLOK® C Channel Isometric 39
GRIDLOK® Unigrid Isometric 40
Accessories
BC45 Connectors 42
BC90 Connectors 43
Appendix – TRACKLOK® 44
Appendix – GRIDLOK® 46
Terms & Conditions 48
ABOUT US/ TRACKLOK RANGE/

TRACKLOK® LTD BELIEVES THE WAY


TO “BUILD IT BETTER” IS THROUGH
A SYSTEMISED APPROACH, WHILE
PROVIDING A BASE LINE FOR
SPECIFIC DESIGN.
The intent of this document is to provide The testing regime has been thorough,
guidance for the bracing of non-structural extensive and has utilised the best minds in
walls and ceilings, while providing engineers the engineering, architectural and academic
with a first principles document enabling world. These results have been accredited,
efficient and consistent specific designs, peer reviewed and ultimately tested in real
where required. world seismic events.

This range of pre-engineered, off the shelf TRACKLOK® Ltd continues to help the
solutions enables architects, designers, construction industry “build it better”. TRACKLOK® - TRACKLOK® for new builds, allows you to connect directly
structural engineers, construction companies through the partition head, separating wall from ceiling. Tested to provide
TRACKLOK Ltd works with like-minded
®
and installers to mitigate the risk of non- structural and seismic performance for internal non-structural walls and glazing
industry leaders worldwide. We work with lines. Steel head track must be a minimum of .75 BMT, while aluminium head
structural failure in commercial buildings.
industry organisations, regulators and track must have a minimum material thickness of 1.3mm. Utilises steel stud for
TRACKLOK® Ltd provides bracing options governments to ensure design through to bracing stock. Using 10-gauge wafer tek screws to attach bracing stock to the
to take the guesswork and liability out of build consistency and compliance. unit and top connectors. Set out charts provide clear guidance for placement.
securing non-structural walls and ceilings. Utilised in IL2, IL3 and IL4 buildings. STOCK CODE: SPT-10
Both the TRACKLOK® and GRIDLOK® range TRACKLOK® RETRO - Bringing an existing fit out up to seismic code, adding
of connections have been designed to value to your clients existing fit out, or create time efficiencies by bracing
comply with building code requirements and after lining. TRACKLOK® RETRO is an effective way to retroactively attach
ceiling manufacturers warranties. to the partition head using 10-gauge wafer tek screws. Steel head track
must be a minimum of .75 BMT, while aluminium head track must have a
The TRACKLOK® system for walls and the minimum material thickness of 1.3mm. Utilises steel stud for bracing stock.
GRIDLOK® system for ceilings are perfect Using 10-gauge wafer tek screws to attach bracing stock to the unit and top
examples of applying logic, innovation and connectors. Disengage walls and ceilings by using TRACKLOK® RETRO. Set
best practice to mitigate risk and improve out charts provide clear guidance for placement. Utilised in IL2, IL3 and IL4
building resilience. buildings. STOCK CODE: SPT-10R

Interior fit out is a complicated, multi trade TRACKLOK® TIMBA - Timber framed walls and timber top plates present
a unique bracing challenge. TRACKLOK® TIMBA is a uniquely designed
discipline, which requires cost and time
solution, allowing the appropriate bracing while ensuring maximum
efficient solutions to standard practices. connection to timber using minimum 10-gauge 35mm wood screws. Timber
The use of these products allows wall and top plate must be minimum 90 x 45mm SG8 Radiata Pine or Douglas Fir.
ceiling systems to perform independently as Locator notch provides perfect placement every time. Utilises steel stud for
designed. bracing stock. Using 10-gauge wafer tek screws to attach bracing stock to the
unit and top connectors. Set out charts provide clear guidance for placement.
Utilised in IL2, IL3 and IL4 buildings. STOCK CODE: SPT-10T
TRACKLOK® VERT - Service clashes are inevitable and although the
TRACKLOK® range provides flexibility with bracing angles from 30° to 60°
there will always be some situations where this is not enough. TRACKLOK®
VERT gives the installer a tool to use a vertical brace on one arm allowing for
the ultimate in clash avoidance. Steel head track must be a minimum of .75
BMT, while aluminium head track must have a minimum material thickness
of 1.3mm. Utilises steel stud for bracing stock. Using 10-gauge wafer tek
screws to attach bracing stock to the unit and top connectors. Also, available
with RETRO and TIMBA bases. Set out charts provide clear guidance for
placement. Utilised in IL2, IL3 and IL4 buildings. STOCK CODE: SPT-10V
2 NZ EDITION FEB 2018 NZ EDITION FEB 2018 3
FEATURES AND BENEFITS/ INSTALL INSTRUCTIONS/

• All products have been tested with steel OBJECTIVES/ 1/ Set out head track (clamp or screw temporarily) must be min .75 BMT steel
and aluminium head track to ensure or min 1.3mm aluminium.
• Prevent injury caused by failure of all types
compatibility.
of internal partition wall and glazing line 2/ Measure TRACKLOK® placements (refer to TRACKLOK® specification sheet).
• Steel head track must be a minimum of systems due to seismic activity.

.75 BMT, while aluminium head track must 3/ Create 30mm - 40mm clearance hole in ceiling tile with holesaw (pilot bit marks centre
• Prevent loss of amenity caused by the
have a minimum material thickness of point on head track).
behaviour of all types of internal partition
1.3mm.
wall and glazing line systems during 4/ Enlarge pilot hole in head track to 9mm. RETRO affixed to head track with 10-gauge
• Full wall system, quasi static testing seismic activity. wafer tek screws. TIMBA affixed to 90mm x 45mm timber top plate with minimum
provides specifiers with confidence. 
 10-gauge 35mm wood screws.
• Protect property and structures from
• Provides seismic separation between wall physical damage caused by the failure
of
and ceiling, preserving warranties. 
 5/ Bolt TRACKLOK® firmly to head track using washer and bolt provided.
all types of internal partition wall and
• Ensures validity of installers PS3. 
 glazing line systems due to seismic activity. 
 6/ Measure distance to structure from fly plate below screw holes and cut your brace
• Tested under ULS and SLS loads to ensure • Preserve ceiling manufacturer’s warranty material to length as per chart provided.
longevity of performance. 
 by providing required seismic separation 7/ Connect bracing material to TRACKLOK® fly brace and top plates.
• Unique design allows for 50mm of inter of partition and glazing lines from ceiling
story drift. 
 system. 
 8/ Fix TRACKLOK® top plates to structure with approved anchor.
• Top plate pivot points allow for 90mm of • Prevent business interruption caused by 9/ Remove temporary fixings.
in-line wall deflection. 
 the failure of all types of internal partition
wall and glazing line systems due to For further installation and limitation information please refer to TRACKLOK®
• Unique design allows for 20mm of wall
seismic activity.
 Terms and Conditions on page 48 or at www.tracklok.com.
“spring back” in ULS event. 

• Patented low profile connection bolt allows • Create efficiencies in construction of all
for clearance in glazing pockets. 
 types of internal partition wall and glazing
• Unit allows a 30° – 60° bracing angle to lines. PLENUM HEIGHT CHART/
mitigate service clashes. 

• Unit tested to 45° off wall axis to mitigate COMPLIANCE/ PLENUM 64 OR 92MM X 64 OR 92MM X 0.55BMT 64 OR 92MM X 0.75BMT
service clashes. 
 • Complies to and provides compliance with HEIGHT MM/ 0.55BMT STUDS*/ BOXED STUDS*/ BOXED STUDS*/
• TRACKLOK® VERT allows vertical bracing NZS 1170.5, AS1170.4 and AS/NZS 4219. 
 0 - 2000 241kgf 241kgf 241kgf
to mitigate service clashes. 
 • Provides compliance with NZ Building 2000 - 3150 - 241kgf 241kgf
• TRACKLOK® RETRO allows for Code Clause B1 – Structure, B2 – Durability,
3150 - 4000 - - 241kgf
retroactive
installation using 10-gauge F2 – Hazardous Building Materials. 

wafer tek screws to affix to head track. 
 • Contributes to compliance with NZ * Stud to TRACKLOK connection to consist of 6/10g tek screws.
®

• TRACKLOK® TIMBA allows for bracing of Building Code Clause F6 – Visibility in


timber framed walls using 10-gauge 35mm Escape Routes, Clause D1 – Access Routes.

wood screws to affix to timber top plate.
Please note timber top plate must be
APPLICATIONS/
minimum 90 x 45mm.

• Importance Level 2, 3 and 4 Buildings
• Allows for 64mm and 92mm bracing to be • Hospitals
used, reducing waste on site. 
 • Commercial Interiors
• Schools

4 NZ EDITION FEB 2018 NZ EDITION FEB 2018 5


TRACKLOK ELEVATIONS/ SEISMIC ZONE CHART/

- TAPCON SCREW ANCHOR

4.9 GRADE M8 ENGINEERS

4.9 GRADE M8 ENGINEERS


- HUS SCREW ANCHORS
CONCRETE ANCHORS

TIMBER JOISTS
- POWER BOLT
- WEDGE BOLT

STEEL BEAMS
- HST STUDS
WHANGAREI
HEIGHT < 3M < 6M < 9M 9M +

BOLT/NUT

BOLT/NUT
POWERS

RAMSET
AUCKLAND
ZONE 1 CHART 1 CHART 1 CHART 1 CHART 1
HILTI
ZONE 2 CHART 1 CHART 1 CHART 2 CHART 2

ZONE 3 CHART 1 CHART 2 CHART 2 CHART 3


TAURANGA
HAMILTON

NOTES ROTORUA
1/ Height (m) is to floor above partition.
NEW PLYMOUTH
TO LENGTH REQUIRED & FIX TO SUPPLIED BRACKETS

2/ Allows for 50mm of inter story drift.


CUT 64mm(min) 0.55BMT(min) GENERIC STEEL STUDS

3/ For wall heights up to 3.0m.



NAPIER
4/ For wall weights up to 40kg per m2.
00° 5/ For wall weights heavier than 40kg
45.

ELEVATION
per m2 and for Importance Level

ENDELEVATION
3 and 4 Buildings please contact

PLAN VIEW
TRACKLOK® Ltd.

WELLINGTON
NELSON
END

CHRISTCHURCH
PILOT HOLE TO BRACKET
TILE & FIX PARTITION VIA
SAW THROUGH CEILING
DRILL HOLE WITH HOLE

ZONE 1
QUEENSTOWN
ZONE 2

ZONE 3
DUNEDIN
10 GAUGE WAFER
TEK SCREWS

INVERCARGILL

6 NZ EDITION FEB 2018 NZ EDITION FEB 2018 7


CHART Door
ONE/ Door
CHART Door
TWO/

Door Door Door Door

BRACING AROUND SMALL ROOMS BRACING AROUND SMALL ROOMS

Door Door

Door Door

Door Door

BRACING BETWEEN RETURN WALLS BRACING BETWEEN RETURN WALLS

STRAIGHT WALLS WITH NO RETURN WALLS


STRAIGHT WALLS WITH NO RETURN WALLS
AUCKLAND/ all levels
WELLINGTON/ up to 3.0m above ground WELLINGTON/ from 3.0m to 9.0m above ground
CHRISTCHURCH/ up to 6.0m above ground CHRISTCHURCH/ above 6.0m from ground

NOTES NOTES
1/ Height (m) is to floor above partition. 1/ Height (m) is to floor above partition.
2/ Spacings based on horizontal load < 0.75 kN/m 2/ Spacings based on horizontal load < 1.20 kN/m
3/ Allows for 50mm of inter story drift. 3/ Allows for 50mm of inter story drift.

Door
4/ For wall heights up to 3.0m. 4/ For wall heights up to 3.0m.
Door
5/ For wall weights up to 40kg per m2. 5/ For wall weights up to 40kg per m2.
6/ Each dashed line represents one brace. 6/ Each dashed line represents one brace.

For wall weights heavier than 40kg per m2 and for Importance Level 3 and 4 Buildings For wall weights heavier than 40kg per m2 and for Importance Level 3 and 4 Buildings
please contact TRACKLOK® Ltd. please contact TRACKLOK® Ltd.
8 NZ EDITION FEB 2018 NZ EDITION FEB 2018 9
CHART THREE/ GAPLOK/
Door Door

Door Door

BRACING AROUND SMALL ROOMS

On occasion, a partition wall or a glazing line placement may coincide with the main runner
Door
or nog of a two-way grid ceiling system. In this instance, there would be no way for a
TRACKLOK® to pass through the grid, with the required clearance. GAPLOK has been carefully
designed, developed and engineered to allow installers to accommodate TRACKLOK®
Door bracing in these instances. GAPLOK provides for 316kgf of capacity.

GAPLOK allows installers to take a 40mm section out of the grid. Clamp GAPLOK to either
side of the remaining grid section to bridge the gap, reinstate the grid’s structural integrity
BRACING BETWEEN RETURN WALLS and allow the clearance required of the TRACKLOK® unit.
STOCK CODE: GGP-10

STRAIGHT WALLS WITH NO RETURN WALLS

WELLINGTON/ above 9.0m from ground

NOTES
1/ Height (m) is to floor above partition.
2/ Spacings based on horizontal load < 1.60 kN/m
New Zealand’s Ministry of Social Development is located at 56 The Terrace, Wellington. This is an
3/ Allows for 50mm of inter story drift.
area prone to seismic activity and can be difficult to design for, however the MSD is an important post
4/ For wall heights up to 3.0m. earthquake agency. TRACKLOK® secured internal, non-structural walls and glazing lines within the building,
5/ For wall weights up to 40kg per m2. as it experienced the forces generated by the 2016 7.8 magnitude Kaikoura earthquake, 400kms to the
south. Great design and engineering have allowed the MSD to continue its work in a safe environment,
Door 6/ Each dashed line represents one brace. post earthquake and TRACKLOK® is proud to have played its part.
For wall weights heavier than 40kg per m2 and for Importance Level 3 and 4 Buildings
please contact TRACKLOK® Ltd.
10 NZ EDITION FEB 2018 NZ EDITION FEB 2018 11
TRACKLOK FLAT/

TRACKLOK® FLAT
Wall bracing can need to allow for large amounts of vertical deflection greater than that
accommodated by wall build up and/or deflection track. Also, projects with a very high
plenum can be impractical to brace. While intense services can leave an installer with no
space through which to install a wall brace. These three situations led to the design and
development of the engineered solution TRACKLOK® FLAT.

TRACKLOK® FLAT utilises the benefits of the TRACKLOK® design and applies it to horizontally
brace partition walls. Employing the principles of a “dragon tie” in residential terms,
TRACKLOK® FLAT can brace one wall off another. TRACKLOK® FLAT is revolutionary.

Ensuring seismic separation, providing ceiling clearance and featuring unique adjustability to
clear troffer lights, sprinkler pipes and services - TRACKLOK® FLAT is an elegant, yet robust
solution. Available in RETRO and TIMBA bases to ensure ease of use.

Steel head track must be a minimum of .75 BMT, while aluminium head track must have a
minimum material thickness of 1.3mm. RETRO affixed to head track with 10-gauge wafer tek
screws. TIMBA affixed to 90mm x 45mm timber top plate with minimum 10-gauge 35mm
wood screws.
STOCK CODE: SPT-10F / SPT-10FR / SPT-10FT

12 NZ EDITION FEB 2018 NZ EDITION FEB 2018 13


FEATURES AND BENEFITS/ INSTALL INSTRUCTIONS/

• All products have been tested with steel OBJECTIVES/ 1/ Set out head track (clamp or screw temporarily) must be min .75 BMT steel or min 1.3mm
and aluminium head track to ensure aluminium.
• Prevent injury caused by failure of all types
compatibility.
of internal partition wall and glazing line 2/ Measure TRACKLOK® FLAT placements (refer to TRACKLOK® FLAT Set Out Guidance).
• Steel head track must be a minimum
systems due to seismic activity. 

of .75 BMT, while aluminium head track 3/ Create 30mm - 40mm clearance hole in ceiling tile with holesaw (pilot bit marks centre
• Prevent loss of amenity caused by the
must have a minimum material thickness point on head track).
behaviour of all types of internal partition
of 1.3mm.
wall and glazing line systems during 4/ Enlarge pilot hole in head track to 9mm. RETRO affixed to head track with 10-gauge
• Full wall system, quasi static testing wafer tek screws. TIMBA affixed to 90mm x 45mm timber top plate with minimum
seismic activity. 

provides specifiers with confidence. 
 10-gauge 35mm wood screws.
• Protect property and structures from
• Provides seismic separation between wall
physical damage caused by the failure
of 5/ Connect first TRACKLOK® FLAT to head track firmly with attachment method supplied.
and ceiling, preserving warranties. 

all types of internal partition wall and
• Ensures validity of installers PS3. 
 glazing line systems due to seismic activity. 
 6/ Measure distance from TRACKLOK® FLAT unit one to unit two and cut 2x lengths of steel
• Tested under ULS and SLS loads to ensure • Preserve ceiling manufacturer’s warranty stud (.75 BMT) to form box section.
longevity of performance. 
 by providing required seismic separation 7/ Connect bracing material to each TRACKLOK® FLAT unit filling all screw holes.
• Unique design allows for unlimited inter of partition and glazing lines from ceiling
story drift. 
 system. 
 8/ Screw off plasterboard top and bottom and silicone glazing into all channels at 300mm
• Patented low profile connection bolt allows centres.
• Prevent business interruption caused by
for clearance in glazing pockets. 
 the failure of all types of internal partition 9/ Remove temporary fixings.
• TRACKLOK® FLAT can be retroactively wall and glazing line systems due to
For further installation and limitation information please refer to TRACKLOK®
installed when combined with a RETRO seismic activity. 

Terms and Conditions on page 48 or at www.tracklok.com.
fitting and using 10-gauge wafer tek screws • Create efficiencies in construction of all
to affix to head track. 
 types of internal partition wall and glazing
• TRACKLOK® FLAT can brace timber framed lines. 
 TRACKLOK FLAT ELEVATIONS/
walls when combined with a TIMBA fitting 64mm or 92mm 0.75 BMT
STUD BOXED
and using 35mm 10-gauge wood screws to COMPLIANCE/
affix to timber top plate. 


• Complies to and provides compliance with
• Allows for 64mm and 92mm boxed bracing
NZS 1170.5, AS1170.4 and AS/NZS 4219. 

to be used, reducing waste on site.
• Provides compliance with NZ Building
Code Clause B1 – Structure, B2 – Durability,
F2 – Hazardous Building Materials. 

• Contributes to compliance with NZ
Building Code Clause F6 – Visibility in
Escape Routes, Clause D1 – Access Routes.
 DRILL HOLE WITH HOLE
SAW THROUGH CEILING
TILE & FIX PARTITION VIA
PILOT HOLE TO BRACKET
APPLICATIONS/
• Importance Level 2, 3 and 4 Buildings
• Hospitals
• Commercial Interiors END ELEVATION
SIDE ELEVATION SIDEELEVATION
END ELEVATION
• Schools

PLAN VIEW
14 NZ EDITION FEB 2018 NZ EDITION FEB 2018 15
TRACKLOK FLAT PARTITION ELEVATIONS/ TRACKLOK FLAT PARTITION ELEVATIONS/

PERMISSIBLE PARTITION LENGTH (L) (MM)

PARTITION HEADTRACK SIZE/


HEIGHT 64 X 0.75 64 X 1.15 92 X 0.75 92 X 1.15
NOTES
MM/ BMT/ BMT/ BMT/ BMT/
- Partition walls are to be internal and non-load bearing
2500 4800 6150 5550 7000
- Structural engineer should confirm strength of partition studs and connections
2750 4800 5590 5050 7000 - Partition walls to be lined both sides with 10mm(min) plasterboard to transfer shear loading
3000 4630 5120 4630 7000 - Permissible partition length shall be taken as the lowest value of in Table 1 when bracing various
headtrack sizes. For example when a 64x0.75BMT is braced to a 92x1.15BMT the permissible wall
3250 4270 4730 4270 6710
length is that of the 64x0.75BMT headtrack
3500 3960 4390 3960 6230 - Based upon a maximum partition weight of 30kg per square metre
3750 3700 4100 3700 5820 - Minimum yield strength of 270mpa and ultimate strength 330MPA required for generic steel studs
4000 3470 3840 3470 5450 - All steel stud brace material must be boxed min .75BMT (see page 26 for detail)

16 NZ EDITION FEB 2018 NZ EDITION FEB 2018 17


CONCRETE CONNECTION DETAILS/ COMFLOR CONNECTION DETAILS/

M6 HILTI HUS-H6 SCREW ANCHOR OR


M8 HILTI HST STUD EXPANSION ANCHOR
SIMILAR SEISMICALLY APPROVED ANCHOR
OR SIMILAR SEISMICALLY APPROVED
INSTALL AS PER MANUFACTURER’S
ANCHOR INSTALL AS PER MANUFACTURER’S
SPECIFICATION SPECIFICATION

55mm(min)
35mm(min)
50mm(min)

35mm(min)
50mm(min)

FIX STEEL STUD TO SUPPLIED BRACKET WITH FIX STEEL STUD TO SUPPLIED BRACKET WITH
6x 10G WAFER TEK SCREWS (TRACKLOK®) 6x 10G WAFER TEK SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®) OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)

M6
M8HILTI
HILTI HUS-H6
HST STUDSCREW ANCHOR
EXPANSION OR
ANCHOR
SIMILAR SEISMICALLY
OR SIMILAR APPROVED
SEISMICALLY ANCHOR
APPROVED
INSTALL
ANCHOR AS PER
INSTALL ASMANUFACTURER’S
PER MANUFACTURER’S
SPECIFICATION
SPECIFICATION

M6 55mm(min)
M8 50mm(min)

50mm(min)

FIX STEEL STUD TO SUPPLIED BRACKET WITH


6x 10G WAFER TEK SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)
18 NZ EDITION EDITION
AUSTRALIAN FEB 2018 AUGUST 2017 NZ EDITION
AUSTRALIAN EDITION FEB 2017
AUGUST 2018 19
PARALLEL STEEL CONNECTION DETAILS/ PERPENDICULAR
PERPENDICULAR STEEL
STEEL CONNECTION
CONNECTION DETAILS/
DETAILS/
TEK SCREW FIXING TEK
TEK SCREW
SCREW FIXING
FIXING

FIX TO 1.15BMT(min) PURLINS

FIX TO TOP HALF OF PURLIN WEB


WITH 4 X 10G WAFER TEK SCREWS

FIX STEEL STUD TO SUPPLIED BRACKET WITH


6x 10G WAFER TEK SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)

FIX FIX STEEL


STEEL STUD
STUD TO SUPPLIED
TO SUPPLIED BRACKET
BRACKET WITH
WITH
6x 10G 6X 10G
WAFER WAFER
TEK TEK(TRACKLOK
SCREWS SCREWS ®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)

BOLT FIXING BOLT


BOLT FIXING
FIXING

FIX TO TOP HALF OF PURLIN


WEB WITH M8 AS 1111 CI. 4.6
BOLT/NUT AND WASHER

FIX STEEL STUD TO SUPPLIED BRACKET WITH


6x 10G WAFER TEK SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)

FIX FIX
STEEL STUD
STEEL TO SUPPLIED
STUD BRACKET
TO SUPPLIED WITH
BRACKET
6x 10G WAFER
WITH TEK
6X 10G SCREWS
WAFER TEK(TRACKLOK
SCREWS ®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)
20 NZ EDITION EDITION
AUSTRALIAN FEB 2018 AUGUST 2017 NZ EDITION FEB 2018
AUSTRALIAN EDITION AUGUST 2017
21
21
PARALLEL TIMBER CONNECTION DETAILS/ PERPENDICULARTIMBER
PERPENDICULAR TIMBERCONNECTION
CONNECTIONDETAILS/
DETAILS/

WOOD SCREW FIXING WOOD SCREW FIXING


WOOD SCREW FIXING

25mm(min)

30mm(min)

FIX STEEL STUD TO SUPPLIED BRACKET WITH


6x 10G WAFER TEK SCREWS (TRACKLOK®) NOTES
NOTES
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)
- -SStructural engineershould
tructural engineer shouldconfirm
confirmloading
loadinginto
into
FIXSTEEL
FIX STEELSTUD
STUDTO
TOSUPPLIED
SUPPLIEDBRACKET
BRACKETWITH thepurlins/joists
the purlins/joistsisisacceptable
acceptable
6x WITH 6X 10GTEK
WAFER TEK SCREWS - -BBridge
COACH SCREW FIXING 10G WAFER SCREWS (TRACKLOK®) detailsuitable
ridge detail suitablefor
forTRACKLOK
TRACKLOK (241kg
(241kg
®®

OR 4x 10G WAFER TEK SCREWS (GRIDLOK®) verticaland


vertical andhorizontal)
horizontal)

40mm(min) BOLTFIXING
BOLT FIXING

FIX STEEL STUD TO SUPPLIED BRACKET WITH


6x 10G WAFER TEK SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)
NOTES
NOTES
- Structural engineer should confirm loading into
-S tructural engineer should confirm loading into
the purlins is acceptable
the purlins is acceptable
- Bridge detail suitable for TRACKLOK®® (241kg
-B ridge detail suitable for TRACKLOK (241kg FIXSTEEL
FIX STEELSTUD
STUDTO
TOSUPPLIED
SUPPLIEDBRACKET
BRACKETWITH
vertical and horizontal)
vertical and horizontal) 6x WITH 6X 10GTEK
10G WAFER WAFER TEK SCREWS
SCREWS (TRACKLOK®)
OR 4x 10G WAFER TEK SCREWS (GRIDLOK®)

22 NZ EDITION EDITION
AUSTRALIAN FEB 2018 AUGUST 2017 AUSTRALIAN NZ
EDITION
EDITIONAUGUST
FEB 2018 23
201723
24
NZ EDITION
REFER TO SPAN NOTES ON PAGE 26

FEB 2018
STRUCTURE STEEL STUD
PURLIN 1.15BMT(MIN) -
FIX TO TOP HALF OF
PURLIN WEB
PARALLEL BRIDGE DETAIL/

FIX STEEL STUD TO SUPPLIED BRACKET


WITH 6x 10G WAFER TEK SCREWS
(TRACKLOK®) OR 4x 10G WAFER TEK
SCREWS (GRIDLOK®)

AS PER PLENUM HEIGHT CHART

REFER TO SPAN NOTES ON PAGE 26

STRUCTURE STEEL STUD


PURLIN 1.15BMT(MIN) -
FIX TO TOP HALF OF
PURLIN WEB
PERPENDICULAR BRIDGE DETAIL/

FIX STEEL STUD TO SUPPLIED BRACKET


WITH 6x 10G WAFER TEK SCREWS
(TRACKLOK®) OR 4x 10G WAFER TEK
SCREWS (GRIDLOK®)
AS PER PLENUM HEIGHT CHART
NZ EDITION
FEB 2018
25
PARALLEL & PERPENDICULAR BRIDGE DETAIL NOTES/ SERVICE BRIDGE DETAIL/

TILE & FIX PARTITION VIA PILOT HOLE TO BRACKET


DRILL HOLE WITH HOLE SAW THROUGH CEILING
SPAN NOTES NOTES
- Boxed 92mm 0.75BMT(min) generic steel studs - Structural engineer should confirm loading
maximum permissible span of 950mm into the purlins is acceptable
- Boxed 150mm 0.75BMT(min) generic steel studs - Bridge detail suitable for TRACKLOK®,
maximum permissible span of 1500mm TRACKLOK® VERT, GRIDLOK®, (210kg vertical
- 90 x 45 SG8 Radiata Pine or Douglas Fir timber and horizontal)
maximum permissible span of 850mm
- 2x 70 x 45 SG8 Radiata Pine or Douglas Fir timber
maximum permissible span of 1500mm
- 2x 90x 45 SG8 F5 Radiata Pine or Douglas Fir timber
maximum permissible span of 2000mm

26 NZ EDITION FEB 2018 NZ EDITION FEB 2018 27


SERVICE BRIDGE DETAIL NOTES/ BULKHEAD BRACING DETAIL/

FIX STEEL STUD TO BC45 BRACKET


(REFER ACCESSORIES PG) WITH
4X 10G WAFER TEK SCREWS

FIX STEEL STUD TO BC45 BRACKET


(REFER ACCESSORIES PG) WITH
4X 10G WAFER TEK SCREWS
NOTES
- Structural engineer should confirm loading into the
purlins is acceptable
STRUCTURE ANCHORAGE NOTES - Bridge detail suitable for TRACKLOK®, (210kg vertical
and horizontal)
CONCRETE:
- M8 HILTI HST stud anchor 50mm(min)
embedment SPAN NOTES
- M8 HILTI HUS screw anchor 50mm(min)
-B
 oxed 92mm 0.75BMT(min) generic steel studs
embedment
maximum permissible span of 950mm
STEEL:
-B
 oxed 150mm 0.75BMT(min) generic steel studs
- M8 CI. 4.6 bolt/nut into 1.15BMT(min)
maximum permissible span of 1500mm
- 4x 10g wafer tek screws into 0.75BMT(min)
-9
 0 x 45 SG8 Radiata Pine or Douglas Fir timber
TIMBER:
maximum permissible span of 850mm
- M8 x 75mm coach screw full penetration
- M8 CI. 4.6 bolt/nut with 20mm x 20mm x -2
 x 70 x 45 SG8 Radiata Pine or Douglas Fir timber
1.5mm washer maximum permissible span of 1500mm
- 4x 10g x 35mm woodscrews 30mm(min) -2
 x 90x 45 SG8 Radiata Pine or Douglas Fir timber
penetration 
 maximum permissible span of 2000mm

28 NZ EDITION FEB 2018 NZ EDITION FEB 2018 29


BULKHEAD BRACING DETAIL NOTES/

PERMISSIBLE BRACE CENTRES (C) MM

HEIGHT STEEL STUD BRACE SIZE/


MM/ 64MM .55 BMT 92MM .75 BMT
1600 2400 2400
1800 1600 2400
2000 1200 2400
2200 900 1500
2400 700 1200
2600 500 900
2800 400 700
3000 300 600

STRUCTURE ANCHORAGE NOTES SPAN NOTES


CONCRETE: -B
 ulkhead is to be internal and non-load bearing
- M8 HILTI HST stud anchor 50mm(min) - Structural engineer should confirm strength of
embedment bulkhead studs and connections
- M6 HILTI HUS-H6 screw anchor 55mm(min)
embedment - Bulkhead to be lined at least one side with
10mm(min) plasterboard to transfer shear loading
STEEL:
- M8 CI. 4.6 bolt/nut into 1.15BMT(min) - Based upon a maximim bulkhead weight of 30kg per
- 4x 10g wafer tek screws into 0.75BMT(min) square metre

TIMBER: - Do not attach ceiling to underside of bulkhead.


- M8 x 75mm coach screw full penetration Additional weight needs to be considered
- M8 CI. 4.6 bolt/nut with 20mm x 20mm x - Continuous track required to transfer load between
1.5mm washer braces. Design to be confirmed by others
- 4x 10g x 35mm woodscrews 30mm(min) - Minimum bulkhead stud steel gauge of 0.75BMT
penetration

30 NZ EDITION FEB 2018 NZ EDITION FEB 2018 31


GRIDLOK® RANGE/ GRIDLOK® RANGE/

GRIDLOK® UNIGRID
Designed and tested to provide a consistent maximum 280kg/f of bracing
capacity to the Armstrong UNIGRID system. Consistency in load capabilities
is the key feature, while the ease of installation will dramatically reduce install
times. Plenum height chart provide guidance on steel stud BMT required
for bracing arms. Get a better result in less time. Features the ability to rotate
the unit though 360° minimising service clashes. STOCK CODE: GRD-10U

FEATURES AND BENEFITS/

GRIDLOK® • Provides maximum 280kg/f of capacity for OBJECTIVES/


Designed and tested to provide a consistent maximum 280kg/f of bracing every brace, every time. 

capacity to two-way grid ceiling systems and drywall grid systems. A • Provide consistent brace capacity for all
• Dramatically reduces install time from up
simple click fit and screw off process dramatically reduces time required to ceiling types. 

to 1.5 hours to 25 minutes per brace.
complete back bracing. Plenum height chart provides guidance on steel • Saves labour and time in the construction
stud BMT required for bracing arms. Features the ability to rotate the unit • Provides consistency of installation and
of ceiling systems that require bracing. 

though 360° minimising service clashes. STOCK CODE: GRD-10 eliminates installer error. 

• Provide a systematic and quantifiable
• Ensures validity of seismic ceiling design
GRIDLOK PEAK FORM
® approach to ceiling bracing. 

and ceiling installers PS3. 

Designed and tested to provide a consistent maximum 280kg/f of bracing • Prevent injury caused by failure of ceiling
capacity to higher profile two-way grid ceiling systems and dry wall grid systems. • Tested under ULS and SLS loads to ensure
systems during seismic activity. 

Simple click fit and screw off process dramatically reduces time required to longevity of performance. 

• Prevent loss of amenity caused by
complete back bracing saving cost to project. Plenum height chart provides • Patented connection saddle applicable to
behaviour of ceiling systems during seismic
guidance on steel stud BMT required for bracing arms. Features the ability to all ceiling main runners. 

activity.
rotate the unit though 360° minimising service clashes. STOCK CODE: GRD-10P • Allows for 64mm and 92mm steel stud to
• Protect property and structures from
GRIDLOK KWIKLOC
® be used as bracing material. 

physical damage caused by failure of
Designed and tested to provide a consistent maximum 280kg/f of bracing • Minimises plenum footprint to reduce ceiling systems during seismic activity. 

capacity to the KWIKLOC ceiling system. Simple click fit and screw off service clashes. 

• Prevent business interruption caused by
process dramatically reduces time required to complete back bracing. • Allows rotation of bracing footprint to the failure of ceiling systems due to seismic
Plenum height chart provide guidance on steel stud BMT required for minimise service clashes. 

bracing arms. Features the ability to rotate the unit though 360° minimising activity. 

service clashes. STOCK CODE: GRD-10K • Employs .64 BMT, .75 BMT or 1.15 BMT
steel stud to minimise waste on site. 

APPLICATIONS/
GRIDLOK® SCREW FIX TCR
• Importance Level 2, 3 and 4 Buildings
Designed and tested to provide a consistent maximum 280kg/f of bracing
capacity to the top cross rail of plasterboard ceiling systems. Simple click
COMPLIANCE/ • Hospitals
fit and screw off process dramatically reduces time required to complete • Complies with AS/NZS 2785. • Commercial Interiors
back bracing. Plenum height chart provide guidance on steel stud BMT • Complies with NZS 1170.2. • Schools
required for bracing arms. Features the ability to rotate the unit though • Complies with NZS 1170.5 and AS 1170.4.
360°minimising service clashes. STOCK CODE: GRD-10S
• Complies with AS/NZS 4219.
GRIDLOK® C CHANNEL • Complies with AS/NZS 4600.
Designed and tested to provide a consistent maximum 280kg/f of bracing • Complies with NZ Building Code Clause
capacity to the C Channel rail of plasterboard ceiling systems. Simple click
B1 – Structure.
fit and screw off process dramatically reduces time required to complete
back bracing. Plenum height chart provide guidance on steel stud BMT • Contributes to compliance with NZ
required for bracing arms. Features the ability to rotate the unit though 360° Building Code Clause F6 – Visibility in
minimising service clashes. STOCK CODE: GRD-10C Escape Routes and Clause D1 – Access
32 NZ EDITION FEB 2018
Routes. NZ EDITION FEB 2018 33
INSTALL INSTRUCTIONS/ GRIDLOK®/

1/ Place GRIDLOK® on main runner in position specified by ceiling designer, ceiling


engineer or ceiling manufacturer.

Fix to Structure in Accordance


with GRIDLOK® Specification
2/ Connect GRIDLOK® to ceiling grid main runner or top cross rail using 10 gauge wafer
tek screws.

3/  otate fly plate to obtain optimum bracing placement on structure over.


R

4/  nsure ceiling grid is at correct height, measure and cut steel stud, as per chart provided
E
and connect to vertical arm.

5/ Attach vertical top connector to structure over.

6/  ut two 45° steel studs as per plenum chart provided, attach to 45° top connectors and
C
45° GRIDLOK® arms.

Height Chart on page


7/  ttach the 45° top connector to the structure over using approved anchor. Ensure all

Refer to Plenum
A

34 of this guide
screw holes are filled.

For further installation and limitation information please refer to GRIDLOK®


Terms and Conditions on page 48 or at www.tracklok.com.

PLENUM HEIGHT CHART/

PLENUM 64 X 0.55BMT 92 X 0.75BMT 64 X 0.55BMT 92 X 0.75BMT

Fix GRIDLOK® Standard to Ceiling


Tee with 4x 10g Wafer Tek Screws
HEIGHT MM/ STUDS*/ STUDS*/ BOXED STUDS*/ BOXED STUDS*/

Height Chart on page


0 - 600 250kgf 280kgf 250kgf 280kgf

Refer to Plenum

34 of this guide
600 - 1000 250kgf 280kgf 250kgf 280kgf
1000 - 1400 250kgf 280kgf 250kgf 280kgf
1400 - 1800 160kgf 270kgf 250kgf 280kgf

50 Max.
1800 - 2200 110kgf 180kgf 250kgf 280kgf
2200 -2600 80kgf 130kgf 250kgf 280kgf
2600 - 3000 60kgf 100kgf 190kgf 280kgf

Fix Studs to GRIDLOK® Standard


3000 - 3500 - - 140kgf 280kgf

with 4x 10g Wafer Tek Screws


Height Chart on page
Refer to Plenum
3500 - 4000 - - 100kgf 210kgf

34 of this guide
* Stud to GRIDLOK connection to consist of 4/10g tek screws
®

34 NZ EDITION FEB 2018 NZ EDITION FEB 2018 35


36
Refer to Plenum

NZ EDITION
Height Chart on page
34 of this guide

FEB 2018
Fix to Structure in Accordance
with GRIDLOK® Specification
Refer to Plenum
Refer to Plenum Height Chart on page
Height Chart on page 34 of this guide
34 of this guide
GRIDLOK® PEAKFORM/

Fix Studs to GRIDLOK®


Armstrong Peakform with
4x 10g Wafer Tek Screws

50 Max.

Fix GRIDLOK® Armstrong Peakform to


Ceiling Tee with 4x 10g Wafer Tek Screws

Refer to Plenum
Height Chart on page
34 of this guide

Fix to Structure in Accordance


with GRIDLOK® Specification
Refer to Plenum
Refer to Plenum Height Chart on page
Height Chart on page 34 of this guide
34 of this guide
GRIDLOK® KWIKLOC/

Fix Studs to GRIDLOK® Bracket


with 4x 10g Wafer Tek Screws

50 Max.
NZ EDITION

Fix GRIDLOK® to Ceiling Tee


FEB 2018

with 4x 10g Wafer Tek Screws


37
38
Refer to Plenum
Height Chart on page

NZ EDITION
34 of this guide

FEB 2018
Fix to Structure in Accordance
with GRIDLOK® Specification
Refer to Plenum
Refer to Plenum Height Chart on page
Height Chart on page 34 of this guide
34 of this guide

Fix Studs to GRIDLOK®


Top Cross Rail with 4x 10g
Wafer Tek Screws
GRIDLOK® TOP CROSS RAIL (TCR)/

Fix GRIDLOK® Top Cross


Rail to Ceiling Tee with 4x
10g Wafer Tek Screws

Refer to Plenum
Height Chart on page
34 of this guide

Fix to Structure in Accordance


with GRIDLOK® Specification
Refer to Plenum
Refer to Plenum Height Chart on page
Height Chart on page 34 of this guide
34 of this guide
GRIDLOK® C CHANNEL/

Fix Studs to GRIDLOK® C Channel


with 4x 10g Wafer Tek Screws

Fix GRIDLOK® C Channel


to Ceiling Tee with 4x 10g Primary
Wafer Tek Screws
NZ EDITION
FEB 2018
39
40
Refer to Plenum
Height Chart on page

NZ EDITION
34 of this guide

FEB 2018
Fix to Structure in Accordance
with GRIDLOK® Specification
Refer to Plenum
Refer to Plenum Height Chart on page
Height Chart on page 34 of this guide
34 of this guide
GRIDLOK® UNIGRID/

Fix Studs to GRIDLOK® Unigrid


with 4x 10g Wafer Tek Screws

Fix GRIDLOK® Unigrid to Ceiling


Tee with 4x 10g Wafer Tek Screws

NZ EDITION
FEB 2018
41
ACCESSORIES - BC45/ ACCESSORIES - BC90/

BULKHEAD & BRIDGING CONNECTOR 45 BRIDGING CONNECTOR 90


Designed and tested to provide a consistent Designed and tested to provide a consistent
and quantifiable connection capacity. Used and quantifiable connection capacity. Used in
in conjunction with steel stud to brace conjunction with steel stud to bridge purlins
bulkheads. Our height vs centres chart allowing parallel and perpendicular bracing
provides install guidance. Also, used to assist connections.
in the bridging of services. STOCK CODE: BC-90 (SOLD IN PAIRS)
STOCK CODE: BC-45 (SOLD IN PAIRS)

STRUCTURE ANCHORAGE NOTES STRUCTURE ANCHORAGE NOTES


CONCRETE: CONCRETE:
- M8 HILTI HST stud anchor 50mm(min) - M8 HILTI HST stud anchor 50mm(min)
embedment embedment
- M8 HILTI HUS screw anchor 50mm(min) - M8 HILTI HUS screw anchor 50mm(min)
embedment embedment
STEEL: STEEL:
- M8 CI. 4.6 bolt/nut into 1.15BMT(min) - M8 CI. 4.6 bolt/nut into 1.15BMT(min)
NOTES NOTES
- 4x 10g wafer tek screws into 0.75BMT(min) - 4x 10g wafer tek screws into 0.75BMT(min)
- Structural engineer should confirm - Structural engineer should confirm
TIMBER: TIMBER:
loading into structure loading into structure
- M8 x 75 coach screw full penetration - M8 x 75 coach screw full penetration
- M8 CI. 4.6 bolt/nut with 20 x 20 x 1.5 washer - Consult TRACKLOK® manual for - M8 CI. 4.6 bolt/nut with 20 x 20 x 1.5 washer - Consult TRACKLOK® manual for
- 4x 10g x 35 woodscrews 30mm(min) permissable applications - 4x 10g x 35 woodscrews 30mm(min) permissable applications
penetration - Do not bend bracket to suit angle penetration - Do not bend bracket to suit angle

42 NZ EDITION FEB 2018 NZ EDITION FEB 2018 43


APPENDIX - TRACKLOK®/ APPENDIX - TRACKLOK®/

OVERVIEW Note this is for ULS design as per “Loading The following assumptions are used: TRACKLOK® components have the following
This report outlines the methods that shall Methodology” section in manual. mu = 1.0 as • The partition wall is sufficiently supported ratings:
be adopted for Specific Engineering Design connections/buckling is limiting. AS 4600 has along the floor track TRACKLOK® 2.37kN
(SED) for TRACKLOK® bracing systems for a maximum value of 1.25 and we have taken • The partition wall has sufficient shear TRACKLOK® RETRO 2.37kN
non-load bearing internal walls. Design the conservative option of 1.0 as per 8.7.1 of resistance in plane TRACKLOK® TIMBA 2.37kN
shall be carried out in accordance with B1/ NZS 1170.5 for non-ductile connections. • The headtrack and wall studs have sufficient TRACKLOK® FLAT 2.37kN
VM1 of the New Zealand Building Code. capacity to transfer load between braces TRACKLOK® VERT 2.37kN
The partition studs and connections are not Wind Action Assumptions Table 1 below, shows TRACKLOK® ratings
considered as part of this scope, however AS/NZS 1170.2 shall be used to determine Brace Demand based on plenum height.
need to be considered within the design. the horizontal and vertical design actions The bracing demand shall be within the
upon the system. The following should be permissible ratings of each TRACKLOK® DESIGN VERIFICATION
LOADING METHODOLOGY adopted for internal walls that do not form a component. Specific engineering design The following standards should be used to
Loading Standards permanent seal: around studs and structure fixings are validate specific engineering design:
The following standards shall be used to • Net Pressure Coefficient, Cfig = ± 0.3 permissible, so long as the demand does not • Steel Studs & Connections: AS/NZS
determine the design actions on the systems: • Dynamic Response Factor, Cdyn = 1.0 exceed the TRACKLOK® ratings. TRACKLOK® 4600:2005 - Cold-Formed Steel Structure
• AS/NZS 1170.0:2002 - Structural Design components are rated as shown in Figure 2 • Timber Studs & Connections: NZS
Actions - General Principles Note that external walls will have a higher net below. Bracing angles shall be considered 3603:1993 - Timber Structures Standard
• AS/NZS 1170.2:2011 - Structural Design pressure coefficient and shall be considered to determine loading in other parts of the • Concrete Anchors: NZS 3101:2006 -
Actions - Wind Actions as part of specific engineering design. design. Concrete Structures Standard
• NZS 1170.5:2004 - Structural Design Actions
- Earthquake Actions Live Actions Assumptions
Soft Body Impact as per Table C1 of AS/NZS
Load combinations shall be applied as 1170.0 shall be considered as follows:
per AS/NZS 1170.0. ULS design shall be • Q = 0.7kN
implemented for the bracing elements,
and SLS deflection requirements should be DESIGN METHODOLOGY
considered for items such as the wall studs Tributary Area
and headtrack to limit damage of the wall. The tributary area method shall be used to
determine the bracing demand. The braces
Seismic Action Assumptions are designed to withstand out of plane loads,
NZS 1170.5 - Section 8 shall be used to as shown in Figure 1 below.
determine the horizontal and vertical design
actions upon the system. The following
assumption should be adopted for bracing
design:
Figure 2 - Illustration of TRACKLOK® component
• Site Subsoil Class C ratings
• Period, T < 0.75s
Ceilings/partitions should be designed
for < 0.75s to give the most adverse Table 1: Permissible horizontal loads in accordance with AS/NZS 4600
component spectral shape coefficient PLENUM 64 OR 92MM X 64 OR 92MM X 0.55BMT 64 OR 92MM X 0.75BMT
Ci(Tp) as per Section 8.4 of NZS 1170.5. HEIGHT MM/ 0.55BMT STUDS*/ BOXED STUDS*/ BOXED STUDS*/
Hard to determine the period of a
0 - 2000 241kgf/2.37kN 241kgf/2.37kN 241kgf/2.37kN
suspended ceiling/partition, so have taken
the conservative option. 2000 - 3150 - 241kgf/2.37kN 241kgf/2.37kN
• Near Fault Factor, N(T,D) = 1.0 3150 - 4000 - - 241kgf/2.37kN
• Ductility, μ = 1.0
• Part Category P.2/P.3 (ULS Design) Figure 1 - Tributary area diagram for design * Stud to TRACKLOK® connection to consist of 6/10g tek screws.

44 NZ EDITION FEB 2018 NZ EDITION FEB 2018 45


APPENDIX - GRIDLOK®/ APPENDIX - GRIDLOK®/

OVERVIEW • Net Pressure Coefficient, Cfig = ± 0.3 Brace Demand DESIGN VERIFICATION
This report outlines the methods that shall • Dynamic Response Factor, Cdyn = 1.0 The bracing demand shall be within the The following standards should be used to
be adopted for Specific Engineering Design permissible ratings of each GRIDILOK® validate specific engineering design:
(SED) for seismic bracing using GRIDLOK® for Note that external ceilings and soffits have a component. Specific engineering design •S teel Studs & Connections: AS/NZS
suspended ceilings. Design shall be carried higher net pressure coefficient and shall be around studs and structure fixings are 4600:2005 - Cold-Formed Steel Structures
out in accordance with B1/VM1 of the New considered as part of specific engineering permissible, so long as the demand does not •T imber Studs & Connections: NZS
Zealand Building Code. Vertical loading and design. exceed the maximum GRIDLOK® rating of 3603:1993 - Timber Structures Standard
specific suspended ceiling system design is 280kgf. •C oncrete Anchors: NZS 3101:2006 -
not covered within this scope. DESIGN METHODOLOGY Concrete Structures Standard
Tributary Area Tributary Area Demand < GRIDLOK®
LOADING METHODOLOGY The tributary area method shall be used to Capacity
Loading Standards determine the bracing demand. The braces
The following standards shall be used to are designed to withstand lateral loads, Table 1 below, shows GRIDLOK® ratings
determine the design actions on the systems: as shown in Figure 1 below. The following based on plenum height.
• NZS 1170.5:2004 - Structural Design Actions assumptions are used:
- Earthquake Actions •A minimum of two braces are used for Table 1: Permissible horizontal loads in accordance with AS/NZS 4600
• AS/NZS 1170.2:2011 - Structural Design stability
Actions - Wind Action •A ll ceiling perimeters are to have a floating PLENUM 64 X 0.55BMT 92 X 0.75BMT 64 X 0.55BMT 92 X 0.75BMT
• AS/NZS 2785:2000 - Suspended Ceilings - connection to allow for inter-story drift HEIGHT MM/ STUDS*/ STUDS*/ BOXED STUDS*/ BOXED STUDS*/
Design and Install •M aximum ceiling tee lengths to be checked 0 - 600 250kgf 280kgf 250kgf 280kgf
as per manufacturer’s requirements
Load combinations shall be applied as •V ertical suspension as per manufacturer’s 600 - 1000 250kgf 280kgf 250kgf 280kgf
per AS/NZS 2785. ULS design shall be requirements 1000 - 1400 250kgf 280kgf 250kgf 280kgf
implemented for the bracing elements as per •T he ceiling behaves as a rigid diaphragm 1400 - 1800 160kgf 270kgf 250kgf 280kgf
Table 8.1 of NZS 1170. •M anufacturer seismic requirements are
1800 - 2200 110kgf 180kgf 250kgf 280kgf
complied with
Seismic Action Assumptions 2200 -2600 80kgf 130kgf 250kgf 280kgf
NZS 1170.5 - Section 8 shall be used to 2600 - 3000 60kgf 100kgf 190kgf 280kgf
determine the horizontal and vertical design
3000 - 3500 - - 140kgf 280kgf
actions upon the system. The following
assumption should be adopted for bracing 3500 - 4000 - - 100kgf 210kgf
design:
* Stud to GRIDLOK connection to consist of 4/10g tek screws
®
• Site Subsoil Class C
• Period, T < 0.4s
• Near Fault Factor, N(T,D) = 1.0
• Ductility, μ = 1.0
• Part Category P.2/P.3 (ULS Design)

Wind Action Assumptions


Where the ceiling is raking, lateral restraint
will be required to resist wind loads. AS/
NZS 1170.2 shall be used to determine the
horizontal and vertical design actions upon
the system. The following should be adopted
for ceilings that do not form a permanent
Figure 1 - Tributary area diagram for design
seal:

46 NZ EDITION FEB 2018 NZ EDITION FEB 2018 47


TERMS & CONDITIONS/

TRACKLOK® INSTALLATION/ GRIDLOK® INSTALLATION/


Must be installed in accordance with manufacturers Must be installed in accordance with manufacturers
specification and within the parameters of AS/ specification and within the parameters of AS/
NZS1170.5. Install sheets are available online NZS1170.5 AS/NZS4219 AS/NZS2785. Install
and in every box of TRACKLOK® | TRACKLOK® sheets are available online and in every box of
RETRO | TRACKLOK® TIMBA | TRACKLOK® GRIDLOK®. Ceilings must be installed as per
VERT | TRACKLOK® FLAT. Partition walls must be manufacturers recommendation. Installation at
installed as per manufacturers recommendation. centres and configurations 
as referenced by ceiling
Create a minimum clearance of 10mm from unit designers, ceiling manufacturers recommendations
to ceiling tile and/or grid. Installation at centres given GRIDLOK® capacity. Construction outside
and configurations as referenced in set out of available information will require consultation
sheets. Set out sheets cover standard partitioning and approval. Approved seismic fixings to be used
requirements; construction outside of available for attachment to structure over. Architect and
set out sheet information will require consultation / or structural engineer plus relevant regulatory
and approval. Approved seismic fixings to be used bodies must approve variations of installation.
for attachment to structure over. Architect and/or Bracing material must be fixed with 10-gauge
Structural Engineer and relevant regulatory bodies drill point wafer head tek screws. Steel bracing
must approve variations of installation. Bracing material must be 64mm .55 BMT, .75 BMT or 1.15
material must be fixed with 10-gauge drill point BMT or 92mm .55 BMT, .75 BMT or 1.15 BMT. All
wafer head tek screws. Steel bracing material must GRIDLOK® units and bracing must be checked
be as per plenum height charts or as designed after seismic event for signs of wear. GRIDLOK® is
by engineer. Although all aluminium head track not intended to replace ceiling suspension wires,
with a material thickness of 1.3mm – 1.8mm is which must be installed as per manufacturers
acceptable for use, we do not take responsibility specification. Although all ceiling grid is acceptable
or liability for performance of, or installation of for use we do not take responsibility or liability for
partition or glazing head track. Use of .55BMT performance of, or installation of ceiling grid. The
steel track, as head section is not permitted under unit must not be deformed or altered in any way.
this specification. Installation is required 100mm – Tenancy changes requiring new ceiling installation
300mm from the end of blade walls. T section walls requires new GRIDLOK® units to be installed.
are deemed self-supporting requiring unit to be
placed at distance specified by the set out sheets. LIMITATIONS/
The unit must not be deformed or altered in any For interior application only. Structural engineer
way. Ceiling void heights over 2.0 meters require and regulatory body must seismically approve
stud bracing to be boxed. Continuous head track configurations outside of specifications. The unit
over door requires unit to be installed on latch and / or bracing material must not be used as an
side, broken head track over door requires units to anchor point or fixing point by associated trades.
be installed on latch side and hinge side. Tenancy NOTICE/
changes requiring walls to be moved require new We shall not be liable for incidental and
units to be installed. consequential damages, directly or indirectly
LIMITATIONS/ sustained, nor for any loss caused by application
For interior application only. Designed to secure of these goods not in accordance with current
standard steel, aluminium and timber partition walls printed instructions or for other than intended use.
and glazed walls. Not applicable for supporting Our liability is expressly limited to replacement
walls constructed from concrete, tilt slab or block. of defective goods. Any claim shall be deemed
Structural engineer and regulatory body must waived unless made in writing to us within thirty
seismically approve configurations outside of (30) days from the date it was or reasonably should
specifications. The unit and or bracing material have been discovered.
must not be used as an anchor point or fixing point The information presented is correct to the best
by associated trades. Use of this product does of our knowledge at the date of issuance. Because
not increase the seismic load capacity of installed codes continue to evolve, check with a local official
ceiling grid. prior to designing and installing. Other restrictions
and exemptions may apply.

48 NZ EDITION FEB 2018 NZ EDITION FEB 2018 49


Available from

www.potters.co.nz
0800 POTTERS
specsupport@potters.co.nz

SALES & INFO


Ph +64 21 152 9136
orders@tracklok.co.nz
info@tracklok.co.nz

TECH SUPPORT
Ph +64 21 170 8734
plans@tracklok.co.nz

TRACKLOK Ltd
PO BOX 31270
Milford
Auckland 0620

www.tracklok.com

50 NZ EDITION FEB 2018

S-ar putea să vă placă și