F6150
Power System Simulator
Basic information
Kamin Dave
Application Engineer (Protective Relaying)
DOBLE ENGINEERING COMPANY
F6-SERIES INTRODUCTION
¾ Hardware
¾ Software
¾ World wide Applications Engineers for
Application support
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6-SERIES INTRODUCTION
¾ High & Constant power output at all ranges
¾ All Power outputs are independent control of
magnitude, Phase Angle & Frequency
¾ All specifications are for worst case operating
condition
¾ Sources have AC/DC outputs
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6000: Single Box Solution
INBUILD F6910+F6810 OPTION
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6000: Single Box Solution
INBUILD F6800-OPTION
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6000: Single Box Solution
INBUILD F6820-OPTION
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6000: Family of Power System Simulators
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150/F6150A Front Panel
Left Bank Right Bank
On/Enabled AC, DC
Source Signal Sources Synch Port
Voltages, Low Range Currents High Range Currents
Battery Ethernet
Simulator Com. Port
Low Level
Sources
Communication
RS232 Port
GPS Antenna
Receiver Port
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: Power System Simulators Features
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: Current Source Power
3*150 VA continuous
3*225 VA for 1.5 seconds
Source Range Com pliance Comment
voltage
Current 7.5 A 20 V Continuous
50/60 Hz 15 A 10 V
30 A 5V
Current 15 A 15 V 1.5 Seconds
50/60 Hz 30 A 7.5 V
60 A 3.75 V
Current DC 5A 30 V Continuous
10 A 15 V
20 A 7.5 V
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: Power System Simulator
¾ Frequency Output.
RANGE:
0.1Hz – 2kHz & DC insteps of 0.001Hz
DC – 3.1kHz TRANSIENT
¾ Phase Angle Output:
RANGE:
0 – 359.9 degree (Lag/Lead) insteps of 0.1degree
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: Power System Simulators
Features: Inputs/Outputs
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: Power System Simulators
Features
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
F6150: SOURCE CONFIGURATION
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
Test Sources Configurations
VA VB VC I1 I2 I3
75VA 75VA 75VA Left Bank (L) 75VA 75VA 75VA Right Bank (R)
VR VS VT IR IS IT
1. User Defined
L R L R
2. 3 x V + 3 x I (all 150 VA) 8. 4 x V + 4 x T (150 & 75 VA) x 1.5
I1
150 VA (30/60 A) I1
I2 450 VA (90/180 A)
150 VA I1
I3 150 VA I1
I1 I1
150 VA (30/60 A)
I2 I2
150 VA (30/60 A)
I3 I3
IN 75 VA (15/30 A)
75 VA (15/30 A)
IR 75 VA
IS 15/30 A
IT
I1
300 VA (60/120 A)
I1
I2
150 VA (30/60 A)
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
Convertible Sources Configurations (Left Bank)
Low Currents
Voltage Configuration
High Compliance Voltage 75-300V
For High Impedance Relays
VA
I1 150 VA (0.5-2) A
150 VA (0.5-2) A VB
I2 150 VA
150 VA (0.5-2) A
I3 3V VC 150 VA
3I 150 VA (0.5-2) A
I1 VA
150 VA (0.5-2) A 150 VA (0.5-2) A
I2 VB
150 VA (0.5-2) A
I3 150 VA
4I 75 VA (0.25-1) A VC
IN 4V 75 VA (0.25-1) A
75 VA (0.25-1) A VN
75 VA
I1
450 VA (1.5-6) A VA
I1
1I
I1 6V VB
VC
I1 VR
6I I2 VS (0.25-1) A
I3
VT
IR 75 VA
IS 0.25-1 A
IT
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
EXAMPLE: 3-VOLTAGE & 1-CURRENT SOURCES CONFIGURATION OF F6150 for CDG or
CDD Relay Testing
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
EXAMPLE: 3-VOLTAGE & 1-CURRENT (TRANSIENT) SOURCES CONFIGURATION OF
F6150
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
Modular Technology
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
Modular Technology
Just “REMOVE/INSERT” CARD from SLOT
Knowledge Is Power SM
Apparatus Maintenance and Power Management
for Energy Delivery
DOBLE ENGINEERING PVT. LTD
305-SAKAR, OLD PADRA ROAD,
VADODARA.
PH: (+91)(265) 555 77 15 & Fax: (+91)(265) 235 62 85
Cell: (+91) 94267 47545
E-MAIL: kdave@doble.com
infokamindave@yahoo.com
Website: www.doble.com