0 10/11/2019 Issued For Tender NV MA IB A 15/10/2019 Issued For Client Review NV MA IB Project No. 1910502 Rev Date Description Prepared Checked Approved 1 GENERAL DATA 38 PROCESS DATA 2 Tag Number TK-2501 39 Products Fresh Water 3 Service Fire Water Storage 40 Specific Gravity 1 4 Number of Tanks (Nos) 1 41 Viscosity ( Cst ) 1 @ 20 oC 5 Dimensions (m) * Diameter x Height 24 x 20 (Note 18) 42 Flash Point (ºc) < -28 6 Roof Type Fixed Cone Roof 43 Vapour Pressure (Kpa) 7.4 7 Geometric Capacity (m³) 9047 44 Operating Pressure Atmospheric 3 8 Storage Capacity (m ) 8300* (Note 18) 45 Internal Design Pressure (Kpa) ATM + Full of Liquid 9 46 External Design Pressure (Kpa) N/A 10 DESIGN DATA 47 Design Temperature Max./Min.(ºc) 80 / 12 11 Design & Construction Code API-650, Latest Edition 48 Operating Temperature Ambient 12 Shell Design Method One Foot Method Variable-Design-Point 49 Design Liquid Sp. Gravity 1 13 Foundation Type * 50 Design Liquid Level (mm) Full Height 14 Minimum Thickness(mm) Shell- Note 15 Roof- * Bottom- Note 15 51 Filling Rate / Emptying Rate (m³/hr) */* 15 Corrosion Allowance Shell- 3 1.5 Roof- 1.5 Bottom- 1.5 52 Tank Refrigeration Required Not Required 16 Joint Efficiency As per Code 53 Heating Required Not Required 17 Tank Bottom Type Cone Down with Center Sump 54 Blanketing Required Not Required 18 Slope 1 : 100 Flat 55 Tank Mixing Required Not Required 19 Tank Roof Cone Dome 56 Tank Gauging Required Not Required 20 Shell Required Not Required 57 Leak Detection System Required Not Required Insulation 21 Roof Required Not Required 58 Cathodic Protection Required Not Required 22 Stiffening Rings As Per Code Not Required 59 H2S Service Required Not Required 23 REMARKS 60 High High * 24 61 High * Tank Liquid Level 25 62 Low * 26 63 Low Low * 27 SITE DATA 64 PAINTING, INSPECTION & TESTING 28 Site Conditions Refer Site Data Sheet 65 Painting (External Shell As Per Project Painting Specification 29 Wind Speed 40 m/sec, 3 sec guest. 66 / Internal) Bottom & Roof 30 Seismic Zone Zone 2A 67 Hydro Test Level Design Liquid Level 31 WEIGHT 68 Radiography As Per Code Not Required 32 Total Empty Weight (MT) * 69 Non Destructive Testing (NDT) As Per Code Not Required 33 Operating Weight (MT) * 70 Galvanizing Of Structural items Required Not Required 34 Hydraulic Test Weight (Full of Water) * 71 (Platform, Stair way & railing) 35 Insulation (MT) * 72 Hot Dip Galvanising for Anchor Bolts Required Not Required 36 73 Potable Water Rinse After Hydrotest Required Not Required 37 74 PHWT / Stress Relieving As Per Code Not Required 75 ACCESSORIES 76 Item Remarks 116 Item Remarks 77 Spiral Stairway Double Stringer Type 117 Side Entry Mixer 78 Tank Earthing Min. 4 no's Earthing lugs 118 Jet Mixer 79 Pipe Support Cleat 119 Level Switch 80 Lighting / Cable Support 120 Emergency Vent As per Code 81 Nitrogen Blanketing 121 PVRV 82 Foam System (NFPA) 122 Floating Suction 83 Clean Out Door 123 Level Transmitter As per Nozzle Index 84 Name Plate 124 Gauge Hatch (Spark Proof) 85 Landing Platform 125 Stilling Well (s) As per Nozzle Index 86 Flame Arrestor 126 Intermediate Platform Every 6m 87 Vortex Breaker Refer Nozzle Index 127 Rolling Ladder 88 Inlet Diffuser 128 All Around Roof Handrail 89 Water draw off sump 1 no's , As per Code 129 Suction Heater 90 Gauger's Platform 130 Drip Ring 106 MATERIAL OF CONSTRUCTION 107 Shell Plates A 36 131 Bolts A 193 Gr B7(Galv) 108 Bottom / annular Plates A 36 132 Nuts A 194 Gr 2H (Galv) 109 Bottom Sketch Plate A 36 133 Welding Fittings A 234 WPB 110 Roof Plates A 36 134 Gaskets SS 316 Spiral wound with graphite wire mesh 111 Shell Nozzles A 106 Gr.B 135 Insulation Supports Not Applicable 112 Shell Flanges A105 136 Stairs/Handrails/Platform A 36 113 Internal Piping A 106 Gr.B 137 Earthing Boss SS 316 114 Fittings A 234 WPB / A 105 138 Internal Piping A 106 Gr.B 115 Nozzles flanges A 105 139 RF. Pads. Shell/Roof A 36 116 Roof Flanges A 105 140 Bolts & Nuts (Internal) SS 316 117 Structural shapes A 36 141 Name Plate SS 316 118 Roof support str. A 36 142 Manhole Neck & Fab. Neck Shell/Roof A 36 or Equivalent 119 Heating Coils N/A 143 Anchor bolts A 36 120 IFR Pontoon / legs / Skin N/A 144 Cleats A 36 121 120 REMARKS 119 118 117
MUCOG-1910502-FF-DS-001 FIRE WATER STORAGE TANK TK-2501 Page1 of 2
TECHNICAL DATA SHEET
FIRE WATER STORAGE TANK TK-2501
Document No. Sheet No
Client AZIKEL PETROLEUM LIMITED MUCOG-1910502-FF-DS-001 2 of 2 Consultant MUC OIL & GAS ENGINEERING CONSULTANCY
0 10/11/2019 Issued For Tender NV MA IB A 15/10/2019 Issued For Client Review NV MA IB Project No. 1910502 Rev Date Description Prepared Checked Approved 1 ROOF DESIGN 2 FIXED ROOF DESIGN 3 Open Top Yes No 11 Thickness * 4 Fixed Roof Type Fixed Cone Roof 12 Snow Load N/A 5 Roof Support Columns Required Not Required 13 Column Lateral Load N/A 6 Cone Slope As per Code 14 Normal Venting Device * 7 Dome or Umbrella Radius N/A 15 Emergency Venting Devices * 8 Weld Joints Lap Butt Others 16 Seal Weld Underside of Lap Joints Yes No 9 Gas - Tight Yes No As per code 17 Seal Weld Underside of Wind Girder Yes No 10 Joint Efficiency As per Code 18 Joints 19 NOZZLE INDEX 20 Sl. No. Nozzle No. Service Qty Size (in) Rating / SCH Flange Type/ Facing Remarks 21 22 1 N1 Inlet 1 8 150# WNRF With Internal Float valve 23 2 N2 Outlet 1 18 150# WNRF With Vortex Breaker 24 3 N3 Drain 1 4 150# WNRF With Internal Flange & Piping to center sump 25 4 N4 A/B Level Switch - Low / High 2 2 150# WNRF 26 5 N5 Recirculation 1 12 150# WNRF With Deflector Plate 27 6 N6 Spare Nozzle 1 2 150# WNRF With Blind Flange 28 7 N7 Over Flow 1 8 150# WNRF With Pipe Extend to Storm Water Drain 29 8 MH-1 Shell Manhole 1 30 As per code As per code With Hing & Davit 30 9 31 10 32 13 33 34 ROOF NOZZLE 35 1 R1 Level Transmitter 1 4* 150# WNRF 36 2 R2 Vent 1 24* * * Free Vent with Bird Screen 37 3 MH-2 Roof Manhole 1 24 As per code As per code 38 4 39 5 40 6 41 7 42 8 43 9 44 INTERNAL FLOATING ROOF NOZZLES (N/A) 45 46 47 48 49 50 51 52 NOTES 53 * To be provided / confirmed during detailed engineering. 54 ** - Applicable 55 - Not Applicable 56 1 Contractor shall provide bolts & gasket for all manhole and nozzles with blind flange. 57 2 Potential sloshing of liquid damage due to seismic activity shall be taking in to consideration for the tank height during detailed engineering. 58 3 Flange Gasket face shall have serrated finish with concentric groove of 125 AARH finish 59 4 Manhole necks & nozzle necks 12" NPS & above shall be fabricated from plate and Long seams shall be 100% Radiographed 60 5 Any tank nozzle not connected to the piping system or appurtenance shall be closed with blind flange. 61 6 Flange dimension shall conform to ASME B16.5 upto 24" NPS except manhole (Manhole as per API 650) flange for nozzle above 24" shall conform to ASME B16.47 62 (Series-A Class 150) unless specified otherwise. 63 8 All requirements mentioned in the Project Technical Specification for Storage Tanks shall be complied. 64 9 Tank Calibration shall be performed in accordance with API- MPMS 65 10 Washers shall be provided under all nuts and bolt heads 66 11 All Structural items shall include 1.5mm Corrosion Allowance. 67 12 All attachments on the Tank/Roof Wall shall be same as that of the Tank/Roof material 68 13 Tank Fabricator to furnish and install 2" NB conduits for instrument cables 69 14 Unless otherwise specified the Grade of Stainless steel used shall be 316L 70 15 The minimum shell plate/bottom plate thickness shall be 8mm or code stipulated thickness which ever is maximum to ensure safe mechanical integrity of the tanks 71 16 The minimum wind girder plate thickness shall be 8 mm . 72 17 100 % redundancy shall be considered for the vents. 73 18 The provided dimension is preliminary only, It shall be finalized during detailed engineering based on the Fire Water Demand calculation. 74 19 Overflow nozzle to be provided with external discharge pipe till the bottom of the tank. 75 76 101
MUCOG-1910502-FF-DS-001 FIRE WATER STORAGE TANK TK-2501 Page2 of 2