Sunteți pe pagina 1din 2

Colonne V= 1.

5 m/s
Sous sol V= 2 m/s
INSTALLATIONS SANITAIRES - CALCUL DES ALIMENTATIONS
Affaire : Indice : A ,
ALIMENTATION EAU FROIDE Date : 4/7/2020
Rep. Désignations Nbre Nbre Débits de base coeff. De Débits Diamètres PPR PN 20 Vitesse
appareils chutes app. chasse appareils trançons simulta- probables calculés tube INT tube ext
l/s l/s néité l/s mm mm mm m/s
ZONE 1
TF1 COLL 5DEPART

- Lavabo 4 0.20 0.8


- W.C 1 0.12 0.12
5 0.92 1.000 0.920 27.95 33.4 50.0 1.05

TF2 COLL 4DEPART

- Urinoir 3 0.15 0.45


- W.C 1 0.12 0.12
4 0.57 0.462 0.263 14.95 16.6 25.0 1.22
TF3 COLL 2 DEPART

- Lavabo 1 0.20 0.2


- W.C 1 0.12 0.12
2 0.32 1.000 0.320 16.49 16.6 25.0 1.48

TF4
- Lavabo 5 0.20 1.00 1.000 1.0
- Urinoir 3 0.15 0.45
- W.C 3 0.12 0.36
6 0.81 0.4 1.3 33.1 33.4 50.0 1.5
ZONE 2
TF5 COLL 6 DEPART

- Lavabo 3 0.20 0.6 1 0.600


- W.C 3 0.12 0.36
3 0.36 0.57 0.204
0.804 26.12 26.6 40 1.45

TF6 - Lavabo 3 0.20 0.60 1.000 0.6


- W.C 3 0.12 0.36
- EVIER 1 0.20 0.20
4 0.56 0.5 0.9 27.0 33.4 50.0 1.0

- Lavabo 8 0.20 1.60 1.000 1.6


- W.C 6 0.12 0.72
Arrivée - EVIER 1 0.20 0.20
Général
- Urinoir 3 0.15 0.45
10 1.37 0.3 1.97 40.9 42.0 63.0 1.4
Colonne V= 1.7 m/s
Sous sol V= 2 m/s
INSTALLATIONS SANITAIRES - CALCUL DES ALIMENTATIONS
Affaire : Indice : A ,
ALIMENTATION EAU CHAUDE Date : 4/7/2020
Rep. Désignations Nbre Nbre Débits de base coeff. De Débits Diamètres PPR PN 20 Vitesse
appareils chutes app. chasse appareils trançons simulta- probables calculés tube INT tube ext
l/s l/s néité l/s mm mm mm m/s

TC1 COLL 4 DEPART

- Lavabo 4 0.20 0.8 1.000 0.800 24.48 26.6 40.0 1.44

TC2 COLL 2 DEPART

- Lavabo 3 0.20 0.6 1.000 0.600 21.20 26.6 40.0 1.08

TC3
- Lavabo 2 0.20 0.4
- Evier 1 0.20 0.2
3 0.6 1.000 0.600 21.20 26.6 40.0 1.08
TC4
- Lavabo 7 0.20 1.4
- Evier 1 0.20 0.2
8 1.6 1.000 1.600 34.63 42.0 63.0 1.16