LP-S070

7inch wide screen, TFT Color LCD type


Graphic panel + PLC function Logic panel LP-S070
Features
● Supports cost reducing, space saving, easy control
by PLC+HMI+I/O module integration
● Adopts 7 inch wide TFT LCD for realizing True Color
with 16,777,216 colors
● Analog touch method
: Free tag arrangement than matrix touch method
● Supports basic I/O of input 16 points, output 16 points
● Supports several device
(auxiliary device 10K Word, data device 10K Word, etc)
● Built-in large capacity memory
(program memory : 8,000 step, drawing memory : 16MB)
● Built-in position control function
: Provides simultaneous output for max.100kHz pulse 2 points 7 inch TFT Color LCD
● Easy software upgrade at website
(1) LP firmware file (2) GP Editor (drawing program)
(3) SmartStudio (Logic program) (4) Additional protocol
(5) Language and font, etc
● Data logger function
: Supports data gathering and backup of controller
● Supports variable image library
● Enables to monitor multi station and multi channel at the same time
● Supports several interface
: Easy to connect various external devices with RS232C 2 ports and RS232C/RS422 multi communication port
: Enables to extension additional external I/O (when connecting Autonics ARM Series, one communication cable
enables to extend 64-point per an address, up to 31-address)

RS485
+ Max. 64-point (ARM 8 units × 8-point)

LP-S070 1 basic unit 7 expansion units


● Supports several fonts: Supports window true type and several bitmap font (Selectable)
● Device monitoring function : Enables to monitor/control variable of connected control through communication
port
● Printer/Barcode reader connection: Enables to print out alarm history, to read barcode
Please read “Caution for your safety” in operation
manual before using.

Manual
Visit our webwite(www.autonics.com) to download 'GP Editor user manual' or 'SmartStudio user manual', 'SmartStudio
programing manual', 'LP Series command manual', 'LP-S070 user manual', 'GP, LP user manual for communication'.
● GP Editor user manual
It describes how to write screen data, and is about related usage of LP-S070 HMI function.
● SmartStudio user manual, SmartStudio programming manual, LP Series command manual
It contains install method and usage, commands, etc of SmartStudio.
● GP, LP user manual for communication : It describes connection for external devices such as PLC.
● LP-S070 user manual : It describes general information on the installation and usage of LP-S070 and system Contents.

Ordering information
Monitor Display Power I/O
Model Item Series Color Interface Module I/O connector
size unit supply composition
RS232C, RS422, Terminal block
LP-S070-T9D6-C5T
USB HOST connector
USB DEVICE, IN: Ribbon cable
LP-S070-T9D6-C5R TFT Ethernet All-in- 16points,
Logic 16,777,216 connector
S series 7 inch Color 24VDC one
panel color RS232C(2), USB Terminal block
LP-S070-T9D7-C5T LCD type OUT:
HOST 16points connector
USB DEVICE, Ribbon cable
LP-S070-T9D7-C5R Ethernet connector

R-26
Logic Panel

Specifications (A)
Photo
electric
Model LP-S070-T9D6-C5T LP-S070-T9D6-C5R LP-S070-T9D7-C5T LP-S070-T9D7-C5R sensor

I/O connector type Terminal block connector Ribbon cable connector Terminal block connector Ribbon cable connector (B)
Fiber
Power supply 24VDC optic
sensor
Allowable voltage range 90 to 110% of power supply
Power consumption Max. 7.2W (C)
Door/Area
LCD type 7 inch TFT Color LCD sensor

Resolution 800×480 dots


Graphic drawing
performance

(D)
Display area 152.4mm×94.44mm Proximity
sensor
Color 16,777,216 color
LCD view angle Within each 50°/ 60°/ 65°/ 65° of top/bottom/left/right (E)
Pressure
Backlight White LED sensor

Brightness Adjustable by software


(F)
Language※1 English, Korean Rotary
Graphic drawing

encoder
performance

• Vector font • 6×8, 8×8 ASCII character, high definition numbers


Text
• 8×16 ASCII characters, 16×16 regional characters(1 to 8 times bigger for width, 0.5 to 5 times bigger for height)
(G)
Graphic drawing memory
16MB Connector/
Socket
Number of user screen
500 pages
Touch switch
Analog touch (H)
Temp.
Command Basic command : 28, application command : 233 controller

Program capacity
8K step
performance

(I)
Processing time
Average : Approx. 2us/basic command, application command SSR/
Control

Power
I/O control type
Batch processing controller

Computer control mode


Repeated-doubling method, interrupt processing
(J)
Device range
*Refer to LP-S070 user manual Counter

Special function
Positioning function *Refer to LP-S070 user manual
Asynchronous method: Each port of RS232C, RS422 (K)
Serial interface Timer
Each port of RS232C, RS422 Two ports of RS232C
USB interface Each of USB Host, USB Device(Version 1.1) (L)
Ethernet interface IEEE802.3(U), 10/100Base-T Panel
meter
Real-time controller RTC embedded
(M)
Battery life cycle Approx. 3 years at 25℃ Tacho/
Speed/ Pulse
Insulated resistance Min. 100MΩ(at 500VDC megger) meter

Ground 3rd grounding(max. 100Ω)


(N)
Noise immunity The squre wave noise(pulse width 1㎲) by the noise simulator with ± 0.5kV Display
unit
Withstanding voltage 500VAC 50/60Hz for a minute
Vibra Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour (O)
Sensor
-tion Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 min. controller

Mechnical 300m/s²(approx. 30G) in each of X,Y,Z directions for 3 times


Shock (P)
Malfunction 100m/s²(approx. 10G) in each of X,Y,Z directions for 3 times Switching
mode power
Environ Ambient temperature 0 to 50℃, storage: -20 to 60℃ supply

-ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (Q)


Stepper
Protection IP65F(for front panel) motor&
Driver&Controller
Accessory Fixing bracket: 4EA, Battery(included)
(R)
Approval Graphic/
Logic
Unit weight Approx. 540g panel

※1: Language can be customized. ※Environment resistance is rated at no freezing or condensation. (S)
Field

Input/Output performance network


device

Input performance Output performance


(T)
Input point 16 points Output point 16 points Software

Insulation method Photo coupler insulation Insulation method Photo coupler insulation
Voltage range 19.2 to 28.8VDC Voltage range 19.2 to 28.8VDC (U)
Other
Rated input voltage 24VDC Rated input voltage 24VDC
Contact X0 to X5: Approx. 10mA
Input resistance Max. load current 0.1A/1point, 1.6A/1COM
Contact X6 to XF: Approx. 4mA
Input resistance Contact X0 to X5: 2.2㏀, Contact X6 to XF: 5.6㏀ Max. voltage falling when ON Max. 0.2VDC
Response time 1ms Response time 1ms
Common method 16 points/1COM Common method 16 points/1COM
Acceptable wire 0.3 to 0.7mm2 Acceptable wire 0.3 to 0.7mm2

R-27
LP-S070

Functional description
Figure display Line, rectangle, circle, text, bitmap
Numeral display Displays the designated device as numerical value.(decimal, hexadecimal, octal, binary, real number)
ASCII display Displays the designated device value as ASCII character.
Time display Displays current time or date.
Alarm history Registers alarm history.
Alarm list Displays generated (not backed up) alarm.
Comment display Displays the designated comment as device status or value.
Lamp Displays lamp as device status.
Part display Displays the designated parts as device status and value.
Tags

Line graph Displays several device values with a graph of broken line.
Trend graph Displays change of device value for time with a graph of broken line.
Bar graph Displays a device value with a bar graph.
Statistic graph Displays a ratio of several device values with pie graph.
Panel meter Displays a device value as panel meter.
Touch key Screen is switched, word/bit device values are set when it touched.
Numeral input Configures user input value in device.
ASCII input Configures user input ASCII code value in device.
System information function Monitors/Controls LP operation from PLC.
Recipe function Reads/Writes several PLC device collectively.
Security function Only acceptable user can observe/operate important data.
Barcode read function Connects barcode reader, read barcode.
Floating alarm function Warning message is floated when alarm is generated.
Time operation Specific bit device is ON/OFF for designated day and time.
Overlap window Available to form dynamically overlapping another base screen on the base one.

Dimensions (unit : mm)


● Panel cut-out
Min. 240
185
Max. 4-R3
+ 1.1
186 0
+ 1.0
0
126

Min. 175

※ Panel thickness
194 6.5 28.5 : Max. 4mm

● Fixing bracket
15
M4 BOLT
134

146
125

R-28
Logic Panel

Part description (A)


Photo
electric
sensor
Input Output Power Run/Stop
terminal terminal LED Switch (B)
Fiber
optic
sensor

(C)
Door/Area
sensor
Program
status LED (D)
Proximity
sensor

(E)
Pressure
sensor

(F)
Rotary
encoder
USB
LCD Screen RS422 RS422 Host (G)
Power terminal or or Ethernet USB Connector/
RS232C RS232C Device Socket
block -A -B
Fixing bracket
(2 slots is in upper side, 2 slot is in lower side) (H)
Temp.
controller

(I)
SSR/
Power
Mounting slot controller
for bracket
(J)
Counter
● Ethernet port : For connecting LAN cable and hub, use direct cable, and for connecting PC direcly, use cross cable.
● USB Device : It is used to upload and download project(It is required to install USB driver on PC), and when connect to
(K)
PC, it can be used as a USB memory(PC recognizes it as a removable disk). Timer

● USB Host: It used to manage data and upgrade firmware.


● RS232C, RS422 port: For more information, refer to R-32 page and ' Serial interface' of GP/LP common features. (L)
Panel
meter

Installation (M)
Tacho/
Speed/ Pulse
1. Set LP-S070 in panel. meter
2. Set fixing brackets in 4 slots(2 slots is in upper side, 2 slots is in lower side).
(N)
Display
unit

(O)
Sensor
controller
(Upper side)
(P)
Switching
mode power
Mounting slot supply
for bracket
(Q)
Stepper
motor&
Driver&Controller

(Lower side) (R)


Graphic/
Logic
panel

(S)
Field

3. Tighten fixing bracket with M4 screw driver and tightening torque is 0.3 to 0.5N.m.
network
device

(T)
Software

M4 Screw driver (U)


Other

R-29
LP-S070

Input·Output wiring
LP-S070-T9D6(7)-C5R
● Input wiring(source type input module) ● Output wiring(sink type output module)
X0 0 8 X8 L Y0 0 8 Y8 L
X1 1 9 X9 L Y1 1 9 Y9 L
X2 2 A XA L Y2 2 A YA L
X3 3 B XB L Y3 B YB L
3
24VDC X4 4 C XC L Y4 YC L
4 C
X5 5 D XD L Y5 YD L
5 D
X6 6 E XE L Y6 YE L
6 E
X7
F XF L Y7 YF L
7 7 F
COM1 COM2
+ + + +
COM3 COM4
+ + 24VDC + +

LP-S070-T9D6(7)-C5T
● Input wiring(source type input module) ● Output wiring(sink type output module)
X0 0 L Y0 0
X1 1 L Y1 1
X2 2 L Y2 2
X3 3 L Y3 3
X4 4 L Y4 4
X5 5 L Y5 5
X6 6 L Y6 6
X7 7 L Y7 7
24VDC X8 Y8
8 L 8
X9 9 L Y9 9
XA A L YA A
XB B L YB B
XC C L YC C
XD D L YD D
XE E L YE E
XF F L YF F
COM1 + +
COM2 24VDC
+ -
※Check the pin number of the case before wiring.

Sold separately
I/O terminal block and I/O cable
Suitable I/O terminal block INPUT/OUTPUT Suitable I/O cable
AFS-H20 INPUT
CJ-HPHP20-V1N -1ANR
(Interface terminal block) OUTPUT
ABS-H16PA(TN)-NN
OUTPUT CJ-HPHP20-V1N -1APR
(Relay terminal block)
AFE4-H20-16LF INPUT CJ-HPHP20-V1N -1BNR
(Sensor connector terminal block) OUTPUT CJ-HPHP20-V1N -1APR
CJ-HP20-VP -R (OPEN type cable)
- -
CJ-HP20-VP -L (OPEN type cable)
※It is only for ribbon cable connector (hirose connector) type.
※" " is for cable length. (Basic specification 010 : 1m, 020 : 2m, the others are option)
※For more information, refer to "I/O terminal block & cable catalog".

Communication cable (RS232C, RS422 port)


For serial connectable cable to connect PLC and external devices, refer to the R-32 page for "GP/LP communication
cable".

R-30
GP/LP Common Features

Serial interface (A)


Photo
● All devices connectable into LP-S044 including PC, PLC, serial printer, barcode reader and dedicated connectors can be electric
sensor
connected into both RS232C and RS422 ports. (B)
● Device must be set for the port in system setting for LP-S044, LP-S070. For details, refer to "GP user manual". Fiber
optic
● Use the dedicated communication cable for the each connected device. sensor

(Refer to the "GP/LP communication cable" of R-32 page)


(C)
● For the method of wiring external devices of PLC, refer to "GP/LP communication manual". Door/Area
sensor
Port NO. Pin(GP-S044, GP-S057, GP-S070) Pin(LP-S044, LP-S070)
RS232C 1 Non-used Non-used (D)
Proximity
2 RXD RXD sensor
5
9 3 TXD TXD
4 (E)
8 4 DTR DTR Pressure
3 sensor
7 5 SG SG
2
6 6 DSR DSR (F)
1 7 Non-used Non-used Rotary
encoder
D-Sub 9Pin 8 Non-used Non-used
Male 9 Non-used Non-used (G)
Connector/
RS422 1 TXD+ TXD+ Socket

2 RXD+ RXD+
5 (H)
6 3 Non-used Non-used Temp.
4 controller
7 4 Non-used Non-used
3
8 5 SG SG (I)
2 SSR/
9 6 TXD- TXD- Power
1 controller
7 RXD- RXD-
D-Sub 9Pin 8 Non-used Non-used (J)
Female 9 Non-used Non-used Counter

Power wiring - F.G. (K)


+ Timer

● For power supply, use the wire of which cross section is at least 0.75mm² and
use the wire of which cross section is at least 1.25mm² for grounding. (L)
Panel
● Use crimp-on type terminal with at least 3mm of internal diameter and less than meter

6mm of external diameter. (M)


● Do not apply power before power line connection. Tacho/
Speed/ Pulse
● Check power polarity. meter

● Tighten the terminal screw with 0.5 to 0.8N·m torque. + - (N)


● Ground resistance should be less than 100Ω and ground it separately. 24VDC
Display
unit

Battery replacement
(O)
Sensor
controller
Please contact out distributor to replace battery.
It may cause an explosion or a fire when improper battery is used. (P)
Switching
mode power
supply

Caution for using (Q)


Stepper
Use communication cable after checking whether there is break, short. motor&
Driver&Controller
Please install power switch or circuit-breaker in order to cut power supply off.
(R)
Separate this unit from high voltage line, power line to avoid inductive noise. Graphic/
Logic
Do not use this product at below places. panel

Place where there is severe vibration or impact (S)


Field
Place where dust exists, or corrosion causing environments. network
device
Place where strong magnetic field or electric noise are generated
Place where is temperature/humidity is beyond the specification (T)
Software
Place where strong alkalis or vibration or impact
Place where there are direct ray of the sun
Installation environment (U)
Other
It shall be used indoor.
Altitude Max. 2,000m
Pollution Degree 2
Installation Category Ⅱ

R-31
General Features

GP(Graphic Panel)? Advantages of using GP


Complicated environment of operation
and control
It graphicalizes mechanical control components such as
button, switch and lamps so that saves cost and space and
improves the preservation of devices.
GP-S044 GP-S057 GP-S070
Graphic panel is HMI(Human Machine Interface) device
Control part GP-S044
that parameter monitors or changes via graphic interface
by communication with PLC, temperature controller or
other control units. Control part GP-S044
Graphic interface of GP is very effective to indicate value Setting and change of production
or status of parameter with visual interface that enables the
communication between controller and user. process
GP is able to monitor parameters virtually with LCD It graphicalizes mechanical control components such as
screen, switch screen by touching screen, set or change button, switch and lamps so that saves cost and space and
parameters. GP connecting with controller via serial improves the preservation of devices.
communication method translates data and displays Alarm alert,
various control parameters with graphic. Preservation of history
For example, in case of the target of parameters is the Alarm is
occurred.
temperate, the numerical value of temperature is shown
with a tag and the change in temperature for time can be
graphed on the screen.
PLC GP-S044

Preparation for using GP Convenient setting by user


It sets complicated or non-displaying controller
(Thermometer/hygrometer, temperature controller etc).
1)Temperature/Humidity without display device

RS485
The numerical value Graph of temperature
of temperature
1) GP body Display temperature,
2) PC 2)Temperature controller humidity
3) GP Editor
- Software for drawing GP screen
RS485
4) Manual
- GP editor user manual
- LP, GP Communication manual Easy to set and
#1...........#32
- GP-S044/S057, GP-S070 user manual adjust parameter.
5) Communication cable Effective data control
- Communication cable for PC connection It prints alarm history of controller using printer. It reads the
- Communication cable for controller connection data from barcode reader and save it in PLC.
6) Access devices 1)PLC/Printer
(PLC or controller built in communication ports)
Basic operation flow
Requirements Install GP Editor PLC GP-S044 Printer
for using GP on PC 2)Barcode reader/PLC

Design data Connection between


with GP Editor PC and GP body
<Refer to GP editer <Refer to GP, LP
user manual> communication manual> GP-S044 PLC

Download display
Communication between heterogeneous
GP connect device controllers
data to GP
<Refer to GP, LP
communication manual>

Start monitoring PLC GP-S044 Thermometer/


hygrometer

R-2
General Features

LP(Logic Panel)? Basic operation flow (A)


Photo
electric
sensor

Requirements for using LP (B)


Fiber
optic
sensor
I/O
HMI
PLC
<Refer to GP editer user manual and SmartStudio> (C)
Door/Area
Install drawing program (GP Editor) and sensor

logic program (Smart Studio) on PC


(D)
Proximity
sensor
<Refer to communication manual>
(E)
Connection PC with LP body Pressure
sensor
※When LP turns on, RUN/STOP switch holds
STOP position.
(F)
Rotary
encoder

<Refer to the SmartStudio programming manual>


LP-S044 LP-S070 (G)
Connector/
Make Logic program with SmartStudio Socket
Logic panel is created for integrated panel in most
demanding industrial environments that have been (H)
Temp.
consisted of HMI, PLC and I/O. The LP through integration controller

realizes cost down, wire reduction, space saving and Download logic data to LP body
(I)
enhanced user friendliness. The logic panel perfectly SSR/
Power
supports serial communication and editing display with GP controller

Editor and about 250 commands of SmartStudio invented


Disconnect Smart Studio with LP body/
on our own to edit PLC ladder/mnemonic, allowing (J)
Connect GP Editor with LP body Counter
accelerating product development and designing. And also
this device can control and monitor various output devices
(sensors, button, etc) and output devices (solenoid, lamp, (K)
Timer
motor, etc) individually. Create screen or download to LP body
(L)
Panel
Preparations for using LP meter

Test
1) LP body ※RUN/STOP switch holds RUN position.
(M)
Tacho/
2) PC Speed/ Pulse
meter
3) Software
① GP Editor (N)
Display
- Software for drawing LP screen Debugging or editing program unit

② SmartStudio
(O)
- Software for logic program Sensor
controller
4) Manual
- GP Editor user manual Control or start monitoring (P)
- GP,LP Communication manual Switching
mode power
- SmartStudio user manual supply
※Refer to the manual for details on website(www.autonics.
- SmartStudio programming manual (Q)
com) resources. Stepper
- LP-S044, LP-S070 user manual motor&
Driver&Controller
- LP series command manual
5) Communication cable (R)
Graphic/
- Communication cable for PC connection Logic
panel
- Communication cable for controller connection
(S)
6) Access device Field
network
(PLC or controller built in communication ports) device

(T)
Production
stoppage models
& replacement

(U)
Other

R-3
General Features

System configurations 1:1:1 configuration (GP/LP Series)


The device function makes it possible to monitor,
Stand alone(LP Series)
control and the operation element (device, parameter,
Stand alone system in LP series controls a variety of I/
etc.) between different devices using two separate
O without adding other devices and monitors and control
communication port.
operation element through direct touch of screen. (device,
parameter, etc.) PC

GP Editor SmartStudio
PC
Drawing data Control program
GP Editor SmartStudio
Drawing data Logic program Download/ Input device Output device
upload data Button Solenoid
Download/ Input device Output device Limit switch Lamp
upload data Button Solenoid Sensors Motor
Limit switch Lamp Other input Other output
A Controls Run Stop devices devices
Sensors Motor
(PLC type)
Other input Other output
Run Stop devices devices

B Controls
(Temperature controller, etc)

1:1 configuration (LP/GP Series) 1:1 N configuration (GP/LP Series)


The device function makes it possible to monitor the
The device function makes it possible to monitor,
operation data (Device, parameter, etc.)
control and the operation element (device, parameter,
etc.) between different devices using two separate
PC communication port.. In case of RS-422 port, 1:N is
GP Editor SmartStudio available only. (Up to 31 units).
Drawing data Control program
PC

Download/ Input device Output device GP Editor SmartStudio


upload data Button Solenoid Drawing data Control program
Limit switch Lamp
Sensors Motor
Other input Other output Download/ Input device Output device
Run Stop devices devices upload data Button Solenoid
Limit switch Lamp
Controls(PLC type) Sensors Motor
Other input Other output
A Controls(PLC type) Run Stop devices devices
#1..................#31
1:N configuration (LP/GP Series)
The device function makes it possible to monitor the
operation element (device, parameter, etc.) by connecting B Controls
in a 1:N configuration (Up to 32 units) (Temperature controller, etc)

Bar-code, printer connection


PC
(GP/LP Series)
#1 GP Editor SmartStudio
It can read bar-code and print a history using printer.
Drawing data Control program
PC
#2
Download/ Input device Output device GP Editor SmartStudio
· upload data Button Solenoid
Drawing data Control program
· Limit switch Lamp
· Sensors Motor
#31 Other input Other output Download/
Run Stop Input device Output device
devices devices upload
Button Solenoid
data
Limit switch Lamp
Controls Sensors Motor
(Temperature Bar-code deader
Other input Other output
controller, etc) Run Stop devices devices

Serial printer

R-4
General Features

Software Manual (A)


Photo

GP Editor(Drawing program) GP/LP common manual electric


sensor

● GP Editor user manual (B)


This section describes how to make screen data and use Fiber
optic
HMI function with GP Editor. sensor

● Communication manual (C)


For more information of serial connection with external Door/Area
sensor
devices such as PLC, refer to manual before connecting.
● GP-S044/S057, GP-S070 user manual (D)
Proximity
The manual describes installation and system organization sensor

and menus.
LP manual (E)
Pressure
sensor
● SmartStudio manual
● This drawing software is for GP/LP series. This section describes how to install and use (F)
● GP Editor is the software that allows creating a screen SmartStudio. Rotary
encoder
and designs a tag layout, and then transfer the data ● Programming manual
from screen to GP/LP. After download, GP/LP starts The manual has command and instruction. (G)
monitoring according to your screen data. ● LP-S044, LP-S070 user manual
Connector/
Socket
The manual describes installation and system organization
SmartStudio(Logic program)
and menus. (H)
Temp.
● LP Series instruction manual controller

The manual has LP installation, system configuration and


(I)
instruction. SSR/
Power
controller

Precaution for using (J)


Do not press touch panel with hard and sharp object. Counter

Please store the device in the recommended temperature


range, or LCD panel can be damaged. (K)
Timer
Please check pin number shown in "Communication manual"
when connect communication port
(L)
Do not block the ventilating opening of this product. Panel
● Logic software is for LP series. Do not use or store it in a place with direct ray of light or dust. meter

● Support multi-project Do not use or store it in a place with shock or vibration. (M)
: It is possible to open maximum 5 projects at a same The ground wire of GP/LP should be grounded separately. Tacho/
Speed/ Pulse
time. The ground resistance should be max. 100Ω, please use the meter

● Easy program editing wire of min. 1.25mm² dimension. (N)


: Block of cell units can be edited. Please check the pin number and connect to GP/LP Display
unit
Split-screen editing is available. communication port.
It provides various editing screens such as variable Please tighten bolt on terminal block with specified tightening (O)
Sensor
screen, describe screen, variable /describe screen, etc,. torque. controller
● Various monitor functions When liquid crystal from the broken LCD is smeared on your
: It provides monitor functions such as variable monitor, skin, wash it for 15 minutes. If it is gotten in your eye, wash (P)
Switching
device monitor and system monitor, time chart. it for 15 minutes and contact a medical specialist for more mode power
supply
● Comfortable user interface information.
(Q)
: It ensures easy operation with Microsoft windows Do not inflow dust or wire dregs into the unit. Stepper
motor&
layout. For cleaning, do not use water or an oil-based detergent, use Driver&Controller

● Wide range of Message windows dry towels. (R)


: It supports various message windows to edit and check It should be done away regarded as an industrial waste. Graphic/
Logic
program. panel

● Real time convert ladder to mnemonic (S)


Field
: Ladder and mnemonic can be written and read to edit network
device
simultaneously.
Visit our website (www.autonics.com) and download (T)
Production
software or manuals. stoppage models
& replacement
< System requirements >
Item Minimum requirements (U)
Other
IBM PC compatible computer with Intel Pentium
System
Ⅲ or above
Operating system Microsoft Windows 98/NT/XP/Vista/7
Memory 256MB or more
Hard disk More than 1GB of free hard disk space
VGA 1024×768 or higher resolution display
Others RS-232 serial port(9-pin), USB port

R-5
General Features

Connectable device with GP/LP


Connectable GP/LP- GP/LP-
Series Connection type GP-S057
device S044 S070
MK-10S1 CPU direct connection loader ○ ○ ○
MK-80S CPU direct connection loader ○ ○ ○
MK-120S CPU direct connection loader ○ ○ ○
LS Master-K
MK-200S CPU direct connection loader ○ ○ ○
MK-300S CPU direct connection loader ○ ○ ○
MK-1000S CPU direct connection loader ○ ○ ○
GM4 CPU direct connection loader ○ ○ ○
LS Glofa GM6 CPU direct connection loader ○ ○ ○
GM7U CPU direct connection loader ○ ○ ○
MK-80S Cnet ○ ○ ○
LS CNET
MK-120S Cnet ○ ○ ○
(Cnet integrated CPU)
MK-200S Cnet ○ ○ ○
MK-80S Cnet ○ ○ ○
MK-120S Cnet ○ ○ ○
LS CNET
MK-200S Cnet ○ ○ ○
(For Cnet unit)
MK-300S Cnet ○ ○ ○
MK-1000S Cnet ○ ○ ○
LS XGT(For Cnet unit) XGK- PUS Cnet ○ ○ ○
LS XGB XBM Cnet ○ ○ ○
(Cnet integrated CPU) XBC Cnet ○ ○ ○
LS XGB XBM Cnet ○ ○ ○
(For Cnet unit) XBC Cnet ○ ○ ○
OEMAX N70 Cnet ○ ○ ○
(SAMSUNG) N70Plus Cnet ○ ○ ○
NX7 CPU direct connection loader ○ ○ ○
OEMAX FARA
NX70 CPU direct connection loader ○ ○ ○
FX1S CPU direct connection loader ○ ○ ○
FX1N CPU direct connection loader ○ ○ ○
MITSUBISHI FX FX2N CPU direct connection loader ○ ○ ○
FX2NC CPU direct connection loader ○ ○ ○
FX3U CPU direct connection loader ○ ○ ○
Q00J Cnet ○ ○ ○
Q00 Cnet ○ ○ ○
Q01 Cnet ○ ○ ○
MITSUBISHI Q Q02 Cnet ○ ○ ○
(For Cnet unit) Q02H Cnet ○ ○ ○
Q06H Cnet ○ ○ ○
Q12H Cnet ○ ○ ○
Q25H Cnet ○ ○ ○
FP0-C10 CPU direct connection loader ○ ○ ○
FP0-C14 CPU direct connection loader ○ ○ ○
FP0-C16 CPU direct connection loader ○ ○ ○
FP0-C32 CPU direct connection loader ○ ○ ○
FPG- C24R2 CPU direct connection loader ○ ○ ○
FPG- C32T CPU direct connection loader ○ ○ ○
NAIS FP FPG- C32T2 CPU direct connection loader ○ ○ ○
FP0R-C10 CPU direct connection loader ○ ○ ○
FP0R-C14 CPU direct connection loader ○ ○ ○
FP0R-C1 CPU direct connection loader ○ ○ ○
FP0R-C32 CPU direct connection loader ○ ○ ○
FP0R-T32 CPU direct connection loader ○ ○ ○
FP0R-F32 CPU direct connection loader ○ ○ ○
CPU221 CPU direct connection loader ○ ○ ○
CPU222 CPU direct connection loader ○ ○ ○
SIEMENS CPU224 CPU direct connection loader ○ ○ ○
SIMATIC
S7-200 CPU224XP CPU direct connection loader ○ ○ ○
CPU224XPsi CPU direct connection loader ○ ○ ○
CPU226 CPU direct connection loader ○ ○ ○

R-6
General Features

Connectable device with GP/LP (A)


Photo
electric
sensor
GP/LP- GP/LP-
Series Connectable device Connection type GP-S057
S044 S070 (B)
Fiber
CPU312 CPU direct connection loader ○ ○ ○ optic
sensor
CPU312C CPU direct connection loader ○ ○ ○
CPU313C CPU direct connection loader ○ ○ ○ (C)
Door/Area
SIEMENS CPU313C-2 CPU direct connection loader ○ ○ ○ sensor

SIMATIC CPU314 CPU direct connection loader ○ ○ ○


(D)
S7-300 CPU314C-2 CPU direct connection loader ○ ○ ○ Proximity
sensor
CPU315-2 CPU direct connection loader ○ ○ ○
CPU317-2 CPU direct connection loader ○ ○ ○ (E)
Pressure
CPU319-3 CPU direct connection loader ○ ○ ○ sensor

MicroLogicx 1000 CPU direct connection loader ○ ○ ○


(F)
Allen-Bradley MicroLogicx 1200 CPU direct connection loader ○ ○ ○ Rotary
encoder
MicroLogicx 1500 CPU direct connection loader ○ ○ ○
OMRON SYSMAC C CPM 1A CPU direct connection loader ○ ○ ○
(G)
E5AN Modbus ○ ○ ○ Connector/
Socket
E5AR Modbus ○ ○ ○
OMRON
E5CN Modbus ○ ○ ○ (H)
Temperature controller Temp.
E5EN Modbus ○ ○ ○ controller

E5ER Modbus ○ ○ ○
(I)
Private communication ○ ○ ○ SSR/
Power
MT Series Modbus ○ ○ × controller

Modbus(TYPE A) ○ ○ ○
(J)
MP Series Private communication ○ ○ ○ Counter

Modbus ○ ○ ×
THD Series
Modbus(TYPE A) ○ ○ ○ (K)
Timer
TZ Series Private communication ○ ○ ○
Modbus ○ ○ ×
TK Series (L)
AUTONICS Modbus(TYPE A) ○ ○ ○ Panel
meter
Modbus ○ ○ ×
TM Series
Modbus(TYPE A) ○ ○ ○ (M)
Tacho/
Modbus ○ ○ × Speed/ Pulse
CT Series meter
Modbus(TYPE A) ○ ○ ○
DS/DA Series Modbus(TYPE A) ○ ○ ○ (N)
Display
ARM Series Modbus(TYPE A) ○ ○ ○ unit

LP-S044, ○ ○ ○
CPU (O)
LP-S070 ○ ○ ○ Sensor
controller
Modbus ○ ○ ×
DPU Series
Modbus(TYPE A) ○ ○ ○ (P)
KONICS Switching
Modbus ○ ○ × mode power
KRN50 supply
Modbus(TYPE A) ○ ○ ○
(Q)
Modbus ○ ○ × Stepper
DELTA DTB Series motor&
Modbus(TYPE A) ○ ○ ○ Driver&Controller

Modbus × × × (R)
DANFOSS FC Series Graphic/
Modbus(TYPE A) ○ ○ ○ Logic
panel
UNIVERSAL UNIVERSAL Modbus(Slave) ○ ○ ○
(S)
MODBUS MASTER MODBUS MASTER Modbus(Master) ○ ○ ○ Field
network
※GP/LP connectable device list will keep updated according to the upgrade of GP Editor or additional patch. It is recommended to device

use the latest version of Editor. (T)


Production
※Applicable GP/LP firmware version is determined by GP Editor version. Whole GP system goes down if non-compatible firmware stoppage models
& replacement
version is used.
※Visit our website (www.autonics.com) to check update of latest GP Editor and GP/LP firmware and to get more detailed (U)
Other
instructions.
※Refer to the user manual to select proper communication cable between GP and controllers. (Sold separately)