Sunteți pe pagina 1din 2

WOODLAND GREY PORTICO

CONCEALED GUTTERING 3640


SUPERDEK PROFILE
WITH RAINHEAD
FALL

SHALE GREY ZINCALUME METRIC COLOURBOND BARGE CAPPING DP


PROFILE 100x50mm
2 DEG PITCH 1:30
1800

800

4.6 DEG PITCH 1:12


DIRECTION
OF ROOF LAYING

8919

PREVAILING

B
WINDS

400

HP DP
DP DP
FALL FALL FALL FALL DN150 FALL
DN150 DN150

2000L
RAINWATER
A
TANK
1230 6130 6130 9956 1230

24676
14 GAUGE SCREWS
x 300mm LONG AT Roof Plan
250mm CENTRES, 25mm
EACH SIDE OF THE
1 Scale: 1 : 100
THERMAL CUT (TYPICAL)

SHALE GREY
BARGE CAPPING
872 8948 PANELS SUPPLIED SQUARE.
MIN 1.2mm THICK
OVERHANG ANGLES TO BE CUT ON
SITE WITH AN ELECTRIC
HANDSAW
4.6° 1:12 461
OVERHANG

50 SHALE GREY
200 Z FLASHING MIN 1.2mm
FOAM THICK

SHALE GREY
COLOURBOND
HALF-ROUND
200mm GUTTER
OFF-WHITE 25% 45 35
GLOSS BEVELLED 45 x 120mm
BOTTOM SHEET LVL TOP PLATE 45 45
(H2 TREATED) "THERMAL CUT":
CUT BOTTOM SHEET SHALE GREY
OF EVERY PANEL EXTERNAL
THERMAL CUT WITH A SAW
ASKIN METRIC SANDWICH ROOF GUTTER BRACKETS
PANEL WITH XFLAM FOAM CORE BLADE.
0.6mm ZINCALUME TOP AND DO NOT CUT
BOTTOM SHEET THROUGH SHEET
CONNECTORS.
SEE DETAIL SHALE GREY
C2.12(D) COLOURBOND
ROUND
150mm DOWNPIPE

7296
Section A
UNSUPPORTED
HORZ SPAN A Scale: 1 : 10
24676

SHALE GREY
COLOURBOND 80
END CAP 80
"THERMAL CUT":
NOTES:
DESIGNED FOR OVERFLOW OF GUTTERS ONCE EVERY 100
YEARS IN CANBERRA = 194 mm/hr
"THERMAL STRIIP":
REMOVE 80mm
FROM THE BOTTOM "THERMAL STRIP"
SHEET TO PREVENT
HEAT LEAKAGE TO
THE EXTERIOR
Revision Date Checked Approved
12 1.8.13 HT HT
90 11 12.7.13 HT HT

Project: New Residence h


nort
Client: Harley Truong
90 53
Drawn: Harley Truong
HOUSE GARAGE

O N Address: 10 Anderson St Chifley Canberra

T I
UC
0 5

T R Roof plan - House 1A

N S
CO
Block: 1 Sec: 3

O R Scale @ A3 1:100 Date: 1.8.13

B
Section B
Scale: 1 : 10 F Drawing No A03.1 Revision: 12
WOODLAND GREY PORTICO
3640 CONCEALED GUTTERING
SUPERDEK PROFILE
WITH RAINHEAD
FALL

DP COLOURBOND BARGE CAPPING SHALE GREY ZINCALUME METRIC


100x50mm PROFILE
2 DEG PITCH 1:30
1800

800

DIRECTION
OF ROOF LAYING
4.6 DEG PITCH 1:12

8919

PREVAILING
WINDS

400

HP
DP DP
FALL FALL FALL FALL FALL
DP DN150 DN150
DN150

2000L
RAINWATER
TANK
980 7806 6130 6130 1230

22276

Roof Plan
1 Scale: 1 : 100

NOTES:
DESIGNED FOR OVERFLOW OF GUTTERS
ONCE EVERY 100 YEARS IN CANBERRA =
194 mm/hr

Revision Date Checked Approved


SEE DRAWING A03.1 ROOF PLAN - HOUSE 1A 12 1.8.13 HT HT
FOR TYPICAL DETAILS 11 12.7.13 HT HT

O N Project: New Residence


nort
h

T I Client: Harley Truong

C
Drawn: Harley Truong

R U
T
Address: 10 Anderson St Chifley Canberra

S
ON
0 5

R C Roof plan - House 1B

FO Block: 1 Sec: 3

Scale @ A3 1:100 Date: 1.8.13

Drawing No A03.2 Revision: 12

S-ar putea să vă placă și