Sunteți pe pagina 1din 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Anchorage Design, with Circular Base Plate, Based on ACI 318-14 & AISC 360-10/16

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc ' = 4 ksi, (28 MPa)
SPECIFIED STRENGTH OF ANCHOR futa = 65 ksi, (448 MPa)
BASE PLATE YIELD STRESS fy = 36 ksi, (248 MPa)
CRITICAL BASE PLATE CANTILEVER m= 3.3 in, (84 mm)
BASE PLATE THICKNESS t= 1.75 in, (44 mm)

FACTORED AXIAL LOAD Pu = 3 kips, (13.3 kN)


FACTORED SHEAR LOAD Vu = 6 kips, ( 0 if shear lug used), (26.7 kN)
FACTORED MOMENT Mu = 38 ft-kips, (52 kN-m)
SEISMIC LOAD ? (ASCE 14.2.2.17) == > Yes

EFFECTIVE EMBEDMENT DEPTH hef = 28 in, (711 mm)


ANCHOR DIAMETER d= 0.75 in, (19 mm)
RADIUS ANCHOR LOCATION R= 8 in, (203 mm)
ANCHOR NUMBERS n= 7
THE PLATE & ANCHORS DESIGN IS ADEQUATE.
DEVELOPED VERTICAL REBAR SIZE # 6

ANALYSIS
DETERMINE MAX ANCHOR FORCES WITHOUT CONCTERE COMPRESSION CAPCAITY CONSIDERED
L= 2pR= 50.27 in T = Pu / A - Mu R / I = -35.89 kips / in2

A = n p d /4 =
2
3.09 in2 Nua,2 = -T A / n = 15.86 kips / bolt, Tension
I = 0.5 A R = 98.96
2
in4 Nua,1 = 16.28 kips / bolt, (The tensile strength, ASCE 14.2.2.17)

Nua = Max( Nua,1 , Nua,2 ) = 16.28 kips / bolt


Vua = 1.5 (Vu / n) = 1.29 kips / bolt

CHECK GOVERNING ANCHOR TENSILE STRENGTH (ACI 318 17.4.1.2)

f N sa = f Ase, N ( f uta ) = 16.28 kips = Nua = 16.28 kips [Satisfactory]

where : f = 0.75 x 1 = 0.75 , (ACI 318-14 17.2.3.4.4)


Ase,N = 0.334 in2

CHECK GOVERNING ANCHOR SHEAR STRENGTH (ACI 318 17.5.1.2 & 17.2.3.5.3)

fV sa = f 0.6 Ase, N f ut = 8.47 k > Vua = 1.29 kips [Satisfactory]

where : f = 0.65 x 1 = 0.65


(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 17.5.1.3)

CHECK TENSION AND SHEAR INTERACTION OF GOVERNING ANCHORS : (ACI 318 17.6)
Since Nua,2 < 0.2 f Nn and
Vua,2 < 0.2 f Vn the full tension design strength is permitted.
The interaction equation may be used

N ua ,2 V ua ,2
+ = 1.13 < 1.2 [Satisfactory]
f N n fV n

CHECK BASE PLATE THICKNESS (AISC Guide - 1, Eq. 3.3.14a)


fp = 4.42 ksi, the max possible concrete compression stress.
(ACI 318-14 22.8.3.2 & 21.2.1, or AISC Guide - 1)

f p
t reqD = 1.5m = 1.73 in < t= 1.75 in [Satisfactory]
Fy
(cont'd)
CHECK SPLICE LENGTH OF TENSION ANCHOR WITH REBAR
L s = 1.3 L d = 32 db = 24 in, (ACI 318-14 25.5)
< hef - 2" = 26 in [Satisfactory]
 
 r 0.075y y y d f 
L d = MAX  , 12 in  =
requird t e s b y
25 db = 18 in
 r provided  +K  
 l f 'c  c b tr   (ACI 318-14 25.4.2.3)
  db  

where r required / r provided = 1.000 ( A s,reqd / A s,provd , if not apply input zero, ACI 318-14 25.4.10.1)
db = 0.75 in, anchor governing
fy = 65 ksi
yt = 1.0 (1.3 for horizontal bar over 12" concrete, ACI 318-14 25.4.2.4)
ye = 1.0 (1.2 for epoxy-coated, ACI 318-14 25.4.2.4)
ys = 0.8 (0.8 for # 6 or smaller, 1.0 for other)
l = 1.0 (0.75 for light weight, ACI 318-14 25.4.2.4)
cb = 1.9 , (ACI 318-14 25.4.2)
Ktr = (Atr fyt / 1500 s n) = 0 (ACI 318-14 25.4.2.3)
(cb + Ktr ) / db = 2.5 < 2.5 , (ACI 318-14 25.4.2.3)

S-ar putea să vă placă și