Sunteți pe pagina 1din 2

Technical Specification

CYG3-30-55-AGM CYG3-30-50-LFP

Prime Rating @ 25°C (kVA) 30

AC Output Voltage 50Hz, 230V L-N, fully adjustable.

Output Connections 1 x 125A three phase CEE Form outlet, variable RCD & MCB protected.
POWER

Custom distribution options available upon request.

Input Connections 1 x 125A three phase CEE Form inlet, MCB protected.

Maintenance charge input connection 1 x 16A single phase CEE Form inlet, MCB protected.

Passthrough 100A

Type AGM (Absorbent Glass Mat) LFP (Lithium Iron Phosphate)


STORAGE

Usable Battery Capacity @ 25°C (kWh) 551 50

Charge Time (hours)2 6 3

Working Life Cycle 3, 4 & 6 1000 5000

7” touch screen IP65 display, providing a user-friendly GUI whilst delivering an enhanced
management & control system.
Key features:
• Generator control; load management, optimised quiet hours and scheduled runs.
• Enhanced system management.
• Ability for users to program custom logic sequences.
CONTROL

ControlCentre
• Enhanced battery string/cell level management.
• System commissioning/decommissioning assistants.
• Troubleshooting assistants & diagnostics.
• User friendly graphical performance & event logs.
• Enhanced environmental control.
• Remote communication, monitoring & control.

Transfer Relay Time (ms) < 20


ENVIRONMENTAL

Water/Ingress Protection Rating IP44

Operating Temperature Range (°C) -20 to +45

Dimensions W x D x H (mm) 1180 x 2380 x 1565


MECHANICAL

Weight (kg) 2700 1640

Lift Points Rotatable Lifting Ring, Forklift Pockets, Lift & Drag Skid

1. Capacity is based on the C20 rate and will vary depending on rate of discharge (see Fig. 1 & Fig. 2) Data may change, as well as legislation, and you are strongly advised to ob-
2. Charge time dependent on available power of external source tain copies of the most recently issued regulations, standards and guidelines.
3. See Fig. 3 This document is not intended to form the basis of a contract. Firefly has a
4. Storage capacity may be affected by charging or discharging at less than 0°C (see Fig. 4) policy of continuous product improvement and reserves the right to change
5. Storage total cycle life may be affected by charging or discharging in excess of 25°C (see Fig. 5) specifications without notice. ©2019 Firefly. All rights reserved.

5 Cairn Court | East Kilbride | Glasgow | G74 4NB | UK


T 0800 091 4090 | F 0800 091 4086 | E sales@fireflyhybridpower.com
www.fireflyhybridpower.com
Firefly CYG3 Datasheet v2.3 - Q3- 2019 A CCL Energy Group Company
Technical Specification
Available Storage vs Load (Fig. 1) Runtime vs Load (Fig. 2)
60 35
Available Battery Capacity (kWh)

55 30

Battery Runtime (h)


25
50
20
45
15
40
10
35 5

30 0
3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0
System Power Output (kVA) System Power Output (kVA)
LFP AGM LFP AGM

Storage Capacity vs Cycle Life (Fig. 3) Storage Capacity vs Temperature (Fig. 4)


110% 120

100% 100
Battery Capacity (%)

90% 80
Capacity (%)

80% 60

70% 40

20
60%
0
50%
-20 -10 0 10 20 30 40
0 500 100 1500 2000 2500 3000 3500 4000 4500 5000
Cycles Temperature (oC)

LFP AGM LFP AGM

AGM 55 LFP 50
Cycle vs Temperature (Fig. 5)
100 Power Available Storage Time Available Storage Time
30kVA 39.2 1.2 48.7 1.5
Cycle Life Derating (%)

80 27kVA 40.0 1.4 48.7 1.7


24kVA 40.8 1.6 48.8 1.9
60
21kVA 41.7 1.9 48.9 2.2
18kVA 42.8 2.3 48.9 2.6
40
15kVA 44.2 2.8 49.0 3.1
12kVA 45.9 3.6 49.1 3.9
20
25 30 35 40 45 9kVA 48.2 5.1 49.3 5.2
Temperature (oC)
6kVA 51.6 8.2 49.5 7.9
LFP AGM
3kVA 58.0 18.4 49.8 15.8

5 Cairn Court | East Kilbride | Glasgow | G74 4NB | UK


T 0800 091 4090 | F 0800 091 4086 | E sales@fireflyhybridpower.com
www.fireflyhybridpower.com
Firefly CYG3 Datasheet v2.3 - Q3- 2019 A CCL Energy Group Company